Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
17A-013
24 HASTINGS HGTS BP-2020-0041 GIS#: COMMONWEALTH OF MASSACHUSETTS Map.-Block: 17A-013 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING P E RM I T Permit# BP-2020-0041 Proiect# JS-2020-000066 Est.Cost: $21808.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: CES DANBURY SOLAR LLC 048196 Lot Size(sg. ft.): 12501.72 Owner. WALKER JEANETTE&SIMON MARK Zoning_RI(100)/URA(100)/WSP(40)/ Applicant: CES DANBURY SOLAR LLC AT. 24 HASTINGS HGTS Applicant Address: Phone: Insurance: 100 SUMMIT LAKE DRIVE (203) 512-4500 WC ValhallaMA10595 ISSUED ON.7/12/2019 0:00:00 TO PERFORM THE FOLLOWING WORK.-ROOF MOUNT SOLAR 5.94KW AND 18 PANELS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 7/12/2019 0:00:00 $75.00 212 Main Street, Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner SOLM(1-- Department use only City of N nn___ Status of Permit: Building epal ,-tc E I V L Curb ut/Driveway Permit t,. 212 M in S ee Sewe /Septic Availability �I RO 10 Wate /Well Availability '3K P Northampt n, M oalcho 1 p 2019 Two ets of Structural Plans ..• ,- — phone 413-587-12 0 F x 413-587-1272 Plot/ ite Plans r�� Othe Specify rl APPLICATION TO CONSTRUCT,ALTER, REPAIR,' LISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION V / 1.1 Property Address: This section to be completed by office 1, Map Lot D// Unit 24 Hasting Heights, Florence, MA 01062 Zone_ Overlay District Elm St. District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Simon Mark and Jeanette Walker Name(Print) Current Mailing Address: 24 Hasting Heights,Florence, MA 01062 Telephone Signature 2.2 Authorized Agent: Id ---- J om'w' Ja-fw Nam(;'( Current ailing Address: _ 512 (� l�•X21 I Si t Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS --7 Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building $19,808 (a)Building Permit Fee 2. Electrical $2,000 (b)Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=(1 +2+ 3 +4 +5) $21,808.00 1 Check Number � ( This Section For Official Use Only Building Permit Number: Date Issued: 41 Signature: -�-._ l 'j� v c�_ �/l I/j 9 Building Commissioner/Inspector of Buildings Date JattanA @ conedceb.com EMAIL ADDRESS (REQUIRED; EITHER HOMEOWNER OR CONTRACTOR) Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 0.29 Frontage 1240 sgft Setbacks Front 40 Side L:22 R: 28 L: R: Rear 40 Building Height 15.79 Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DON'T KNOW � YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES C) IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW Q YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained 0 , Date Issued: C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing El Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [M Siding [O] Other[p] Brief Description of Proposed Roof mounted solar PV installation-5.94kW DC-5.OkW AC-(18)LG330NIC-A5-(1)SE5000H-US-No structural upgardes Work: Alteration of existing bedroom Yes X No Adding new bedroom Yes X No Attached Narrative Renovating unfinished basement Yes X No Plans Attached Roll -Sheet sa. If New house and or addition to existing housing, complete the following: a. Use of building : One Family X Two Family Other Solar PV b. Number of rooms in each family unit: 6 Number of Bathrooms 2 c. Is there a garage attached? Yes 2 d. Proposed Square footage of new construction. V 5 Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes X No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Simon Mark and Jeanette Walker as Owner of the subject property CES Danbury Solar LLC-Amaris Jattan hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Owner Date I, amaj�l v as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print N e 2�( Owner/Agent Dake SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable IR Name of License Holder- Andrew G. Mayshar License Number 048196 Address Expiration Date 309 Mill Road, North Haven, CT 06473 07/23/2020 Signature Telephone (203) 512-4500 9.Registered Home Improvement Contractor. Not Applicable ❑ CES Danbury Solar LLC Company Name Registration Number 100 Summit Lake Drive,Valhalla, NY 10595 186927 Address Expiration Date Telephone(203)512-4500 02/05/2021 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6 Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit, Signed Affidavit Attached Yes-..... 0 No-- 0 City of Northampton Massachusetts w i, DEPARTMENT OF BUILDING INSPECTIONS �E r 212 Main Street • Municipal Building Northampton, MA 01060 (l0� AFFIDAVIT Home Improvement Contractor Law Supplement to Permit Application The Office of Consumer Affairs and Business Regulation("OCABR")regulates the registration of contractors and subcontractors performing improvements or renovations on detached one to four family homes.Prior to performing work on such homes,a contractor must be registered as a Home Improvement Contractor("HIC"). M.G.L.Chapter 142A requires that the"reconstruction, alteration, renovation, repair,modernization, conversion, improvement, removal, demolition, or construction of an addition to any pre-existing owner-occupied building containing at least one but not more than four dwelling units....or to structures which are adjacent to such residence or building"be done by registered contractors. Note:If the homeowner has contracted with a corporation or LLC,that entity must be registered Type of Work: Solar PV roof mounted installation Est.Cost:$21,808 Address of Work: 24 Hastings Heights, Florence, MA 01062 Date of Permit Application: 07/01/2019 I hereby certify that: Registration is not required for the following reason(s): _Work excluded by law(explain): _Job under$1,000.00 Owner obtaining own permit(explain): Building not owner-occupied Other(specify): OWNERS OBTAINING THEIR OWN PERMIT OR ENTERING INTO CONTRACTS WITH UNREGISTERED CONTRACTORS OR SUBCONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK ARE NOT ELIGIBLE FOR AND DO NOT HAVE ACCESS TO THE ARBITRATION PROGRAM OR GUARANTY FUND UNDER M.G.L.Chapter 142A.SUCH OWNERS ALSO ASSUME THE RESPONSIBILITES FOR ALL WORK PERFORMED UNDER THE BUILDING PERMIT.SEE NEXT PAGE FOR MORE INFORMATION. Signed under the penalties of perjury: I hereby apply for a building permit as the agent of the owner: 07/01/2019 CES Danbury Solar,LLC 186927 Date Contractor Name HIC Registration No. OR: Notwithstanding the above notice,I hereby apply for a building permit as the owner of the above property: Date Owner Name and Signature City of Northampton r Massachusetts �'r1 DEPARTMENT OF BUILDING INSPECTIONS �. 212 Main Street •Municipal Building Northampton, MA 01060 �y ^t� Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 24 Hastings Heights, Florence, MA 01062 (Please print house number and street name) Is to be disposed of at: All American Waste-182 Danbury Road, New Milford, CT 06776 'Please note:ALL debris will be removed from site by construction (Please print name and location of facility) crew and disposed of in our All American Waste dumpster at our field office at;38 Beaver Brook Road, Danbury,CT 06810 Or will be disposed of in a dumpster onsite rented or leased from: (Company Name and Address) DoeuSigned by: 3 7/11/2019 sFcorsrcssF.�a�F- Signature of Permit Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. Massachusetts Department of Public Safety Board of Building Regulations and Standards License: CS-046196 Construction Supervisor ANDREW G MAYSHAR 309 MILL ROAD NORTH HAVEN CT 06473 Covmmis'sioner 07J231020 n The Commonwealth of Massachusetts x Department of IndustrialAccidents I Congress Street, Suite 100 Boston,MA 02114-2017 www mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):CES Danbury Solar LLC Address:100 Summit Lake Drive City/State/Zip:Valhalla, NY 10595 Phone #:(203) 512-4500 Are you an employer?Check the appropriate boa: Type of project(required): 1. ✓❑I am a employer with 40 employees(full and/or part-time).* 7. ❑New construction 2.❑I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] 9. El Demolition 3.F1 I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 4.[:]l am a homeowner and will be hiring contractors to conduct all work on my property. I will 10 [:] Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.rl I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.[:]Roof repairs These sub-contractors have employees and have workers'comp.insurance. 6.EJ We are a corporation and its officers have exercised their right of exemption per MGL c. 14.❑✓ Other Solar PV 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Marsh USA, Inc Policy#or Self-ins.Lic.#:WC5-691-544681-078 Expiration Date:09/01/2019 Job Site Address:24 Hasting Heights City/State/Zip:Florence, MA 01062 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby,ce a pains and penalties of perjury that the information provided above is true and correct. Signature: Date:07/01/2019 Phone — -512-4500 Official use only. Do not write in this area,to be completed by city or town official, City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute,an employee is defined as"...every person in the service of another under any contract of hire, express or implied,oral or written." An employer is defined as"an individual,partnership,association,corporation or other legal entity,or any two or more of the foregoing engaged in a joint enterprise,and including the legal representatives of a deceased employer,or the receiver or trustee of an individual,partnership,association or other legal entity,employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein,or the occupant of the dwelling house of another who employs persons to do maintenance,construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152,§25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally,MGL chapter 152,§25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely,by checking the boxes that apply to your situation and,if necessary,supply sub-contractor(s)name(s),address(es)and phone number(s)along with their certificate(s)of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners,are not required to carry workers'compensation insurance. If an LLC or LLP does have employees,a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested,not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year,need only submit one affidavit indicating current policy information(if necessary)and under"Job Site Address"the applicant should write"all locations in (city or town)."A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year.Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e.a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents 1 Congress Street, Suite 100 Boston,MA 02114-2017 Tel. #617-727-4900 ext. 7406 or 1-877-MASSAFE Fax#617-727-7749 Revised 02-23-15 www.mass.gov/dia Connecticut Office mm.RossSolarGrouh.com ROSS 38 Beaver Brook Road Info ac RossSolarGroup.conl Danbury,CT 06810 Phone:(303)512-4500 SOLARFax:(866)271-3016 GROUP Attn: Building Department Official I, Jeanette Walker authorize Ross Solar Group to install the Rooftop, ground mount or pole mount solar array and to file a building permit,zoning, wetland & health departments on my behalf. I grant Ross Solar Group permission to access a copy . this property's survey, site plans and building plans. Should you have any questions, or r uire adVitiolna' details, please call Ross Solar Group at 203-512-4500. V V C40 ,— ne Owners Signature 35wk 1�a(k r- Print Name Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: LLC CES DANBURY SOLAR, LLC Registration: 186927 Expiration: 02/05/2021 100 SUMMIT LAKE DRIVE SUITE 210 VALHALLA, NY 10595 Update Address and Return Card. SCA 1 20M--05/C117 Office of Consumer Affairs& Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE: LLC before the expiration date. If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 186927 02/05/2021 1000 Washington Street-Suite 710 CES DANBURY SOLAR, LLC Boston, MA 02118 / r; LORENATAVLARIOS 100 SUMMIT LAKE DRIVE SUITE 210 0 VALHALLA, NY 10595 Not valid without signature Undersecretary WESTSHORE WM DESIGN ENGINEERS, P.C. - 100 GREAT OAKS BLVD. I SUITE 117A ALBANY I NEW YORK I 12203 To: Coned Solutions 38 Beaver Brook Rd. Danbury,CT 06810 Date: May 7,2019 Ref.: 19050203 Subject: Walker Residence 24 Hasting Hts. Florence,MA To Whom It May Concern, The following references the Walker residence in Florence, MA: 1. Existing roof framing: Pre-fabricated/engineered wood truss is 2x4 at 24"o.c.This existing structure is capable to support all the loads that are indicated below for this photovoltaic project. 2. Roof Loading: - 4.33psf dead load(modules plus mounting hardware) - 40psf ground snow load - 5.1 psf roof materials(I.I psf 2x4, 1.5psf sheathing,2.5psf asphalt shingles) - Exposure Category B, 125mph wind gust(3 sec.) This installation design will be in general conformance to the manufacturer's specifications,and complies with all applicable laws, codes, and ordinances, specifically the International Building Code/IBC 2015 and International Residential Code/IRC 2015 including all MA regulations and amendments.The spacing and fastening of the mounting brackets is to have a maximum of 48"o.c. span between mounting brackets, staggered, and secured using 5/16" diameter corrosive resistant steel lag bolts. A minimum of 2.5" of penetration per lag bolt is required,which is adequate to resist all 125mph wind live loads including wind shear. Per NDS Section 11.1.4 clearance holes equal to the diameter of the shank need to be bored into primary a primary framing member for the full length to the threaded portion of the screw to avoid splitting of the framing member. Thank you. Westshore Design Engineers �HOF]LIssgcti E3/.6.30-0 G,JF NICOLAS A. NITTI CIVIL P_ NO. 50222 Rf01STQ 9�FFSSI0NALEN��a+ 5/7/2019 John Eibert Nicolas Nitti,PE Project Coordinator President WestShore Design Engineers 1 100 Great Oaks Blvd. I Suite 117A I Albany,NY 12203 1518.313.7153 Ross Solar A ConEdieon Solutwo co"gmv CONED SOLUTIONS 2X4 TOP CHORD @ 24"O.C. 38 B.—B—k Roed DANBURY,Ci 06810 "wlv.mm 5/8"PLY SHEATHING W/ASPHALT PH:203.512.4500 SHINGLE TYPE - — -- - -- - LG33OW MODULE 0 2X4 WEB @ 24"O.C. ❑ \ 89 79„ .2O4 001, _ Q N 2X4 CEILING JOIST @ 24"O.C. � 2X6 DOUBLE PLATE \ iN M Q4 56.00" 125.05" q PLYWOOD L F - 22.00" yy N U Q C`C � I ROOF SECTION ai U '-- U. 0) ' h w �o w mow,E DESIGNED BV: IRONMDOE RAR DRAWN BY: ROOF LFC MEMBRANE w�¢.•; APPROVED BY: IRONIUWE RASHFOOT2 DATE 05/07/2019 8U1�"O' SHEET NUMBER STRUCTURE z MOUNT SYSTEM 3 INSTALLATION DETAIL PV-2 PV-2 Sm1e:NTS PV-2 SCAB r:irr SHEET10F1 Ross Solar A ConEckwn Sokdors cortpazry CONEDSOLUTIONS 78 Bp—B.&Road DANBURY.CT 06810 PH:201.312.0500 O vr G .. .< U O f� O O w � o rrlrrm or Z x O N 3 to Alk A, F l�ti W �' W J W I E MOVE UP THE BREAKERS " AND INSTALL THE NEW f BREAKER `' a o IN THE BOTTOM „ a DESIGNED BY: _.: DRAWN BY: LFC APPROVED BY: MAIN SERVICE PANEL INSIDE CLOSET IN BASEMENT DATE 05/07/2019 METER SHEET NUMBER SP-C SHEET 10F 1 (OLG • Life's Good LG NeON 2 EZ�MMM EMM LG's new module,LG NeCIN119 2,adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires ^ fl) ry-,to enhance power output and reliability.LG NeCNT""2 /VE CE 60 cell demonstrates LG's efforts to increase customer's values -- beyond efficiency.It features enhanced warranty,durability, Intertek performance under real environment,and aesthetic design suitable for roofs. Enhanced Performance Warranty High Power Output LG NeON'"2 has an enhanced performance warranty. Compared with previous models,the LG NeON'"2 The annual degradation has fallen from-0.6%/yr to has been designed to significantly enhance its output -0.55%/yr Even after 25 years,the cell guarantees 1.2%p efficiency,thereby making it efficient even in limited space. more output than the previous LG NeON'"2 modules. Aesthetic Roof ® Outstanding Durability LG NeCIN'"°2 has been designed with aesthetics in mind; With its newly reinforced frame design,LG has extended thinner wires that appear all black at a distance. the warranty of the LG NeCIN'"2 for an additional The product may help increase the value of 2 years.Additionally,LG NeON'"2 can endure a front a property with its modern design. load up to 6000 Pa,and a rear load up to 5400 Pa. -•- Better Performance on a Sunny Day Double-Sided Cell Structure s LG NeCIN'"2 now performs better on sunny days thanks The rear of the cell used in LG NeCIN'""2 will contribute to to its improved temperature coefficiency. generation,just like the front;the light beam reflected from the rear of the module is reabsorbed to generate a great amount of additional power. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985,supported by LG Group's rich experience in semiconductor,LCD,chemistry,and materials industry We successfully released the first Mono X''-'series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,LG NeON'"(previously known as Mono Xm NeON)won"Intersolar Award"which proved LG is the leader of innovation in the industry. LG NeON z Mechanical Properties Electrical Properties(STC*) Cells 6x 10 Module LG335N1C-A5 LG330N1C-A5 LG325N1C-AS _ ............................................... ......... _ ._. ..._. . Cell Vendor LG Maximum Power(Pmax) 335 330 325 --------- - -------- ----- ------ ------ ------ --- -- - Cell Type Monocrystalline/N-type MPP Voltage(Vmpp) 34.1 33.7 33.3 ......... -.... -- - -- ._--_...._...---- ._......._..._......................................-...-...... - - - -- - ---------- - ------------- Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) 9.83 9.8 9.77 ---------...------_...----------------------------------------------- ------------------------- - - ---------- _ - ........................................-.._............. ......._........... a of Busbar 12(Multi Wire Busbar) Open Circuit Voltage(Voc) 41.0 40.9 40.8 - ---.__ -- __..-..- _.._ - .. ._. ..... - ......._----_-- - - .- _ ....--- ---... _....._-- - . - .....-- -- - ..-.. --- ---------- ......._..._ ....._... D _-imensions(L x W x H) 1686 x 1016 x 40 mm Short Circuit Current(Isc) 10.49 10.45 10.41 66.38 x 40 x 1.57 inch Module Efficiency 19.6 19.3 19.0 ----------------....-.--.......__...._...._...._._....__.........................._......................_.......................... Front Load 6000Pa Operating Temperature -40-+90 -.......--.......--..............._............_......_.......----------------------------------------------------------_-..--.._-....._........... - - ------------------------.-...._........._-------------------------------------------------_ Rear Load 540OPa Maximum System Voltage 1,000 - __............. .---------------------___..-_......_.................... ....... --- --- _...__..__.... - ...-.....-...__ - Weight 18 kg Maximum Series Fuse Rating 20 ....._..._......._...._-....---......._.... --.._.._....--..... - - ......-......__...._..... ....._............................-.........-- - -- ---- -- - - Connector Type MC4 Power Tolerance(%) 0-+3 - - ------------------------------------------------......-----------------._--._....__._--....._..__...._._....__.._.._....._..._.... Junction Box IP68 with 3 Bypass Diodes •STC(Standard Test Condition):Irradiance 1,000 W/m',Ambi nt Temperature 25°C,AM 1.5 ....-.......------------------------------...__.............................._-..._.__._....._._...._-_-___._-_-__-._._._..._......._._._.-.......-- Cables 1000 mm x 2 ea •The nameplate power output is measured and determined by G Electronics at its sole and absolute discretion. .-_-_-_-._--------- . -_. ._.--- -.. __------ - __._.____ ___.._. _____ ..__... •The Typical change in module efficiency at 20OW/m'in relation to 1000W/m2 is-2.0%. Glass High Transmission Tempered Glass Frame Anodized Aluminium Electrical Properties(NOCT*) Certifications and Warranty Module LG335N1C-A5 LG330N1C-A5 LG325N1C-A5 Certifications IEC 61215,IEC 61730-1/-2 _ Maximum Power(Pmax) 247 243 240 UL 1703 MPP Voltage(Vmpp) 31.5 31.2 30.8 -._.- - --------- - --------- - .................... ----------------------------------------------------------- IEC 61701(Salt mist corrosion test) MPP Current(Impp) 7.83 7.81 7.78 --- -- - IEC 62716(Ammonia corrosion test) Open Circuit Voltage(Voc) 38.2 38.1 38.0 ISO 9001 Short Circuit Current(Isc) 8.44 8.41 8.38 - ---------------------------------------._................---------------------------------------- ........ ----------------------. Module Fire Performance(USA) Type 1 "NOCT(Nominal Operating Cell Temperature):Irradiance 800 /m',ambient temperature 20°C,wind speed 1 m/s -----------------..-.... .-...................---- - --- -- --------------------------- Fire Rating(CANADA) Class C(ULC/ORD C1703) --- -------------------- Product Warranty 12 years Output Warranty of Pmax Linear warranty** Dimensions(mm/in) "*1)1 st year:98%,2)Aker 2nd year:0.55%annual degradation,3)25 years:84.8% Temperature Characteristics g' j NOCT 45 t 3 Pmpp -0.37%/°C Voc -0.27%/°C °'•"°a ------ -------- -- -- ----- - - Isc _ 0.03%/°Ca TT Characteristic Curves �°- ,.1 l 000w eoow 1:, 600w 6 , I � n 400W 4 . f z -� i 0 5 10 is 20 25 30 35 40 '1 140 E 120�. 100{'.... _ ____........_.. � eoi 3 P_ 603 40 .... -..- -._. -.- -. IF a ----- 201......................_........._....._._._..._...._..............._..._.....__.._._...._._._...._..._..__.................. Temperaurce(°Q 40 25 90 OLNorth /�► America Solar Business Team Product specifications are subject to charge without notice. a'� ••o V LG Electronics U.S.A Inc Life's Good 1000 Sylvan Ave,Englewood Cliffs,N107632 �late Copyright©2017 LG Electronics All rights reserved. Innovation for a Better Life Contact:tg.solar@tge.com 01/01/2017 www.lgsolarusa.com solar - . . • Single Phase Inverter with HD-Wave Technology • for North America SE3000H-US/SE380OH-US/SE5000H-US/ SE6000H-US/SE760OH-US/SE10000H-US/SE1140OH-US ' sokar_TT -,vim E ova rte, W?25 ' iian�Y el1aV • 1 • ♦ u 0 e 9 e ! ! 4 a Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring IIIII111111, Outdoor and indoor installation wave Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us so I a r " • • � Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US / SE10000H-US/ SE1140OH-US SE3000H-US SE380OH•OS 56000H-US SE6000H-US SE760OH-US SE1000OH-US SE11400H-US OUTPUT 3800 @ 240V 6000 60 240V Rated AC Power Output 3000 5000 7600 10000 11400 VA ........ .... ........ ............... ......3300 208V ............... .5000, 208V ................. ..I. ...... 3800 240V 6000 @ 240V 3300 @ 208V ..-.•..-_,_•.., ,500 208V Max.AC Power Output 3000 5000 7600 10000 11400 VA ....................................... �. ...... . AC Output Voltage Min.-N om:Max. Vac ........................... AC Output Voltage Min.-Nom.-Max. ✓...... .......✓....... .......✓....... ................. .......✓.......!........✓....... .......✓....... ... c.... Va ..211 240 264)........................... . AC Frequency(Nominal).................. 59:3.:60.:60,5111.................. Hz.... ........... Maximum Continuous Output Current 16 24 ! A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A °�.?4QY................._................. .......I........ ................ ................ ................. ................!................. ................. ........... GFDI Threshold 1 A ...................................... ......................................................... ............................. Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT MaximumDC Power.@240V. ... 4650 5900 7750 9300 11800 5500 17650 W ...... . ..... Maximum DC Power @208V.._.I.._..... _ 5100 ......... ......7750 ........ ...... ................ ..... ........... . .... .. . .. . . . . Transformer.Iess,Ungrounded Yes Maximum In ut Volta a 480 Vdc Nominal DC Input Volta a 380 400 Vdc Maximum Input Current 208V 9 13.5 Maximum Input Current @240V......... ......$:5......I......10:s......1.....13:5...... ......16:5...... .......ZO.......I..... .27.......�......30:5...... ...Adc.... Max:Input Short Circuit Current 45 Adc Reverse-Polar" Protection Yes ...............– .......................... ................................................ ....................... ........... Ground-Fault Isolation Detection 600ka Sensitivity ................................. ................ ...................... ........... Maximum Inverter Efficiency............. ......99....... ..................................................99:2.................. % CEC Weighted Efficiency 99 ..................................... ..................................................................................... .. ............................. ........... Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) ... ... Revenue Grade Data,.AN51.C12.20 .._ . ...... .......:. ...... ....._.....•_.!. (inaI!Zi-- -. --,- up Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown on AC Grid Disconnect 690.12 _ STANDARD COMPLIANCE —T Safety UL1741,UL1741 SA,UL1699B,CSA C22:2,Canadian AFCI according to LLL,M.07 Grid Connection Standards IEEE1547 Rule 21 Rule 14(HI) .... . .. .... ......... ......... ......... .... ........ .. ...... ....... ........ . ......... ............. ..... .. ...... .... 1 ....... Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/#of Strings/ 3/4"minimum/1 3 strings/ 3/4"minimum/1-2 strings/14-6 AWG AWG Rang?........ 14.6 AWG............ ........... 6x7.3/540x3703 x 14. Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8/450 x 370 x 174 21. x 185 in/mm .............................................. ................................. ................ .............................. .....-A................... ........... Weight with Safety Switch................ .............22/.10.............1..25.1/11:4.. ...........26.2/11.9.... 38:8./17:6............ .Ib/.kg... Noise <25 <50 dBA Coolin Natural Convection Natural convection �..... ......... ................... .......... ...... .... –.. ... ... Operating Temperature Range -13 to+140/-25 to+60(31(-40'F/.40'C option)i' -F/.-C ......................... Protection Rating ..NEMA 3R(Inverter with Safety Switch) 1'1 For other regional settings please contact SolarEdge support Revenue grade inverter P/N:SExxxxH-US000NNC2 13)For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (4)-40 version P/N:SExxxxH-USOOONNU4 RoHS Q ,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of •,ge• •• Date: gies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.