38B-197 206 South St rescheckProject Title: Report date: 06/11/09 Data filename: Page 1 of 3 Generated by REScheck-Web Software Compliance Certificate Energy Code:2006 IECC Location:Hampshire County, Massachusetts Construction Type:Single Family Conditioned Floor Area:720 ft2 Glazing Area Percentage:42% Heating Degree Days:6999 Climate Zone:5 Construction Site:Owner/Agent:Designer/Contractor: 206 South St Northampton, Massachusetts 01060 Alabama Alabama Compliance: Passes on UA Compliance: 13.4% Better Than Code Maximum UA: 382 Your UA: 331 Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value Glazing or Door U-Factor UA Ceiling: Flat or Scissor Truss 384 56.0 0.0 9 Wall: Wood Frame, 16in. o.c.356 39.0 0.0 7 Window: Wood Frame, 2 Pane w/ Low-E 150 0.300 45 SHGC: 0.37 Door: Solid 18 0.300 5 Door: Solid 18 0.090 2 Floor: Heated Slab-On-Grade 384 10.0 263 Insulation depth: 4.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Date Project Title: Report date: 06/11/09 Data filename: Page 2 of 3 Generated by REScheck-Web Software Inspection Checklist Ceilings: q Ceiling: Flat or Scissor Truss, R-56.0 cavity insulation Comments: Above-Grade Walls: q Wall: Wood Frame, 16in. o.c., R-39.0 cavity insulation Comments: Windows: q Window: Wood Frame, 2 Pane w/ Low-E, U-factor: 0.300 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Note: Up to 15 sq.ft. of glazed fenestration per dwelling is exempt from U-factor and SHGC requirements. Doors: q Door: Solid, U-factor: 0.300 Comments: q Door: Solid, U-factor: 0.090 Comments: Floors: q Floor: Heated Slab-On-Grade, 4.0' insulation depth, R-10.0 continuous insulation Comments: Slab insulation extends down from the top of the slab to at least 4.0 ft. OR down to at least the bottom of the slab then horizontally for a total distance of 4.0 ft. Air Leakage: q Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. q Recessed lights are either 1) Type IC rated with enclosures sealed/gasketed against leaks to the ceiling, or 2) Type IC rated and ASTM E283 labeled, or 3) installed inside an air-tight assembly with a 0.5" clearance from combustible materials and a 3" clearance from insulation. Sunrooms: q Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U-factor of 0.50 and the maximum skylight U-factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Vapor Retarder: q Vapor retarder is installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors; or it has been determined that moisture or its freezing will not damage the materials; or other approved means to avoid condensation are provided. Comments: Materials Identification: q Materials and equipment are identified so that compliance can be determined. q Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. q Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. q Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Project Title: Report date: 06/11/09 Data filename: Page 3 of 3 q Ducts in unconditioned spaces or outside the building are insulated to at least R-8. q Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6. Duct Construction: q Air handlers, filter boxes, and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and mechanically fastened. q All joints, seams, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved closure systems. Tapes and mastics are rated UL 181A or UL 181B. q Building framing cavities are not used as supply ducts. q Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. q Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International Mechanical Code. Temperature Controls: q Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Certificate: q A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values; window U-factors; type and efficiency of space-conditioning and water heating equipment. NOTES TO FIELD: (Building Department Use Only) 2006 IECC Energy Efficiency Certificate Insulation Rating R-Value Ceiling / Roof 56.00 Wall 39.00 Floor / Foundation 10.00 Ductwork (unconditioned spaces):_____ Glass & Door Rating U-Factor SHGC Window 0.30 0.37 Door 0.30 NA Heating & Cooling Equipment Efficiency Water Heater:___________________________ Name:Date: Comments: