38B-197 206 South St rescheckProject Title: Report date: 06/11/09
Data filename: Page 1 of 3
Generated by REScheck-Web Software
Compliance Certificate
Energy Code:2006 IECC
Location:Hampshire County, Massachusetts
Construction Type:Single Family
Conditioned Floor Area:720 ft2
Glazing Area Percentage:42%
Heating Degree Days:6999
Climate Zone:5
Construction Site:Owner/Agent:Designer/Contractor:
206 South St
Northampton, Massachusetts 01060
Alabama Alabama
Compliance: Passes on UA
Compliance: 13.4% Better Than Code Maximum UA: 382 Your UA: 331
Assembly
Gross
Area or
Perimeter
Cavity
R-Value
Cont.
R-Value
Glazing
or Door
U-Factor
UA
Ceiling: Flat or Scissor Truss 384 56.0 0.0 9
Wall: Wood Frame, 16in. o.c.356 39.0 0.0 7
Window: Wood Frame, 2 Pane w/ Low-E 150 0.300 45
SHGC: 0.37
Door: Solid 18 0.300 5
Door: Solid 18 0.090 2
Floor: Heated Slab-On-Grade 384 10.0 263
Insulation depth: 4.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2006 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
Project Title: Report date: 06/11/09
Data filename: Page 2 of 3
Generated by REScheck-Web Software
Inspection Checklist
Ceilings:
q Ceiling: Flat or Scissor Truss, R-56.0 cavity insulation
Comments:
Above-Grade Walls:
q Wall: Wood Frame, 16in. o.c., R-39.0 cavity insulation
Comments:
Windows:
q Window: Wood Frame, 2 Pane w/ Low-E, U-factor: 0.300
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Note: Up to 15 sq.ft. of glazed fenestration per dwelling is exempt from U-factor and SHGC requirements.
Doors:
q Door: Solid, U-factor: 0.300
Comments:
q Door: Solid, U-factor: 0.090
Comments:
Floors:
q Floor: Heated Slab-On-Grade, 4.0' insulation depth, R-10.0 continuous insulation
Comments:
Slab insulation extends down from the top of the slab to at least 4.0 ft. OR down to at least the bottom of the slab then horizontally for a
total distance of 4.0 ft.
Air Leakage:
q Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
q Recessed lights are either 1) Type IC rated with enclosures sealed/gasketed against leaks to the ceiling, or 2) Type IC rated and ASTM
E283 labeled, or 3) installed inside an air-tight assembly with a 0.5" clearance from combustible materials and a 3" clearance from
insulation.
Sunrooms:
q Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U-factor of 0.50 and the maximum
skylight U-factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope
requirements.
Vapor Retarder:
q Vapor retarder is installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors; or it has been determined that
moisture or its freezing will not damage the materials; or other approved means to avoid condensation are provided.
Comments:
Materials Identification:
q Materials and equipment are identified so that compliance can be determined.
q Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
q Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
q Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Project Title: Report date: 06/11/09
Data filename: Page 3 of 3
q Ducts in unconditioned spaces or outside the building are insulated to at least R-8.
q Ducts in floor trusses above unconditioned spaces or above the outdoors are insulated to at least R-6.
Duct Construction:
q Air handlers, filter boxes, and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and
mechanically fastened.
q All joints, seams, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved closure
systems. Tapes and mastics are rated UL 181A or UL 181B.
q Building framing cavities are not used as supply ducts.
q Automatic or gravity dampers are installed on all outdoor air intakes and exhausts.
q Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International
Mechanical Code.
Temperature Controls:
q Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Certificate:
q A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values; window
U-factors; type and efficiency of space-conditioning and water heating equipment.
NOTES TO FIELD: (Building Department Use Only)
2006 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Ceiling / Roof 56.00
Wall 39.00
Floor / Foundation 10.00
Ductwork (unconditioned spaces):_____
Glass & Door Rating U-Factor SHGC
Window 0.30 0.37
Door 0.30 NA
Heating & Cooling Equipment Efficiency
Water Heater:___________________________
Name:Date:
Comments: