Ceiling girder CalcCS Structure™ 2.14.50 [Build 4]
kmBeamEngine 4.13.4.1
Materials Database 1530
KeiterScottPoolHouse102315 - L 10-23-15
1:25pm
1 of 2
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG3 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 10.7 PLF
Filename: C:\KMW\JOBS\
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 12' 0.00" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 0.00" 0 13 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 0.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 0.00" 27 7 Live
Point (LBS) Top 0' 2.63" 0 3 Live
Point (LBS) Top 0' 2.63" 0 54 Live
Point (LBS) Top 0' 2.63" 1 94 Live
Point (LBS) Top 0' 2.63" 142 0 Snow
Point (LBS) Top 0' 2.63" 248 0 Snow
Point (LBS) Top 6' 0.00" 2 344 Live
Point (LBS) Top 6' 0.00" 715 0 Snow
Point (LBS) Top 11' 9.38" 0 3 Live
Point (LBS) Top 11' 9.38" 0 54 Live
Point (LBS) Top 11' 9.38" 1 94 Live
Point (LBS) Top 11' 9.38" 142 0 Snow
Point (LBS) Top 11' 9.38" 248 0 Snow
1 2
12 0 0
12 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1332# -171#
2 12' 0.000" Wall SPF Plate (425psi) N/A 1.500" 1332# -171#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 311# 747# 538#
2 311# 747# 538#
Design spans
11' 6.750"
Product: 1-3/4x7-1/4 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 3843.# 15028.# 25% 6' Total Load D+0.75(L+S)
Negative Moment 933.# 13068.# 7% 6' Total Load D+L
Shear 842.# 8317.# 10% 11.2' Total Load D+0.75(L+S)
TL Deflection 0.2406" 0.5781" L/576 6' Total Load D+0.75(L+S)
LL Deflection 0.1380" 0.3854" L/999+ 6' Total Load 0.75(L+S)
CS Structure™ 2.14.50 [Build 4]
kmBeamEngine 4.13.4.1
Materials Database 1530
KeiterScottPoolHouse102315 - L 10-23-15
1:25pm
2 of 2
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table