15-Division 13000 Special ConstructionDate
Page
Rev.
R1
01May '12
Erection Guide
Date
Page
Rev.
R2
01Feb '12
Erection Guide
Date
Page
Rev.
R3
01May '12
Erection Guide
Date
Page
Rev.
R4
00Jan '12
Erection Guide
Primary Frame Detail
Interior Beam Column
PF03002
May '12 01
Corner Column Girt Connection
Partially Open Sidewall and Endwall
EF02008
Apr '11 01
Bearing Frame Endwall
Bypass with Bolted Girt - End Post not at Peak
EF07001
Dec '12 03
Bearing Frame Endwall
Bypass without Girt - End Post not at Peak
EF07004
Dec '12 02
EF07018Bearing Frame Endwall - Bypass without Girt
End Post with Column Extension at Inner Flange not at Peak Dec '12 02
End Post to Bridge Clip Connection
Hot Rolled Bridge Channel
EF09003
Feb '11 01
Type 1 Connection
End Post located in Purlin Foul Zone
EF09009
Feb '11 01
End Frame Detail Rigid End Frame With By-pass Girts
Column Extension On Inner Flange
EF08018
Dec '12 01
Cable Brace
Attachment at Web
PF04111
Nov '11 00
By-Pass Girt to Column
"Optional" Liner Connection - Flange Brace FB4_
CF01202
Mar '11 01
By-Pass Girt to Column
"Optional" Liner Connection - Flange Brace FB6_ or FB7_
CF01205
Mar '11 01
Cee Girt to Column
"Optional" Liner Connection - Flange Brace FB4_
CF01208
Mar '11 01
Purlin to Rafter - Bolted Flange
Standard Connection - Flange Brace FB4_
CF02060
Dec '10 00
Purlin to Rafter - Bolted Flange
Standard Connection - Flange Brace FB6_ or FB7_
CF02063
Dec '10 00
CP04101
Sep '12 01
Flush Transverse Partition - Corner Girt Connections
Aligned and/or Non-Aligned Partition Girt with Bypass Sidewall Girt
PF04120
00May '12
Spandrel Beam
Unbraced Beam to Other Construction
Pre-Assembled Walk Door Anchor Placement AC05110
Dec '11 00
534" Walk Door Installation
w/ Framed Opening
AC05122
Dec '11 00
PBU Wall Panel - Walk Door & Glass-Front Walk Door
Trim Installation with Field Notch Panel at Head Trim
PU09022
Dec '11 00
PBU Wall Panel - Walk Door & Glass- Front Walk Door
Field Notch Panel at Head Trim
PU09023
Dec '11 00
PBU Wall Panel - Walk Door & Glass-Front Walk Door
Trim Installation with Field Notch and Bend Tabs at Head Trim
PU09024
Dec '11 00
PBU Wall Panel - Walk Door & Glass-Front Walk Door
Field Notch and Bend Tabs at Head Trim
PU09025
Dec '11 00
PBU Wall Panel - Walk Door & Glass-Front Walk Door
Jamb Trim Field Cut Details
PU09027
Dec '11 00
PBU Wall Panel - Preassembled Walk Door & Glass-Front Walk Door
Jamb Trim Installation
PU09029
Dec '11 00
PBU Wall Panel - Preassembled Walk Door & Glass-Front Walk Door
Head Trim Installation
PU09030
Dec '11 00
AC05113
Dec '11 00
Walk Door Head Detail
Preassembled Door - PBR Liner Panel
AC05114
Dec '11 00
Walk Door Jamb Detail
Preassembled Door - PBR Liner Panel
PBU Wall Panel - Four Sided Framed Opening
Trim Installation with Field Notch Panel at Head Trim
PU06022
00Jan '12
PBU Wall Panel - Four Sided Framed Opening
Field Notch Panel at Head Trim
PU06023
00Jan '12
PU06024PBU Wall Panel - Four Sided Framed Opening
Trim Installation with Field Notch and Bend Tabs at Head Trim 00Jan '12
PBU Wall Panel - Four Sided Framed Opening
Field Notch and Bend Tabs at Head Trim
PU06025
00Jan '12
PBU Wall Panel - Four Sided Framed Opening
Sill Trim Installation
PU06026
00Jan '12
PBU Wall Panel - Four Sided Framed Opening
"Optional" Channel Closure Trim
PU06028
00Jan '12
PBU Wall Panel - Four Sided Framed Opening
Head and Sill Trim Installation
PU06030
00Jan '12
PBU Wall Panel - Three Sided Framed Opening
Trim Installation with Field Notch Panel at Head Trim
PU07022
00Jan '12
PBU Wall Panel - Three Sided Framed Opening
Field Notch Panel at Head Trim
PU07023
00Jan '12 00
PU07024PBU Wall Panel - Three Sided Framed Opening
Trim Installation with Field Notch and Bend Tabs at Head Trim Jan '12
00
PBU Wall Panel - Three Sided Framed Opening
Field Notch and Bend Tabs at Head Trim
PU07025
Jan '12
PBU Wall Panel - Three Sided Framed Opening
"Optional" Channel Closure Trim
PU07028
00Jan '12
PBU Wall Panel - Three Sided Framed Opening
Head Trim Installation
PU07030
00Jan '12
AVP / PBA Wall Panel Installation
Fastener Spacing
PA05004
Mar '13 03
AVP / PBA Wall Panel
Panel End Lap
PA05011
Mar '13 01
PBU Wall Panel - Four Sided Framed Opening
Jamb Trim Field Cut Details
PU06027
00Jan '12
PBU Wall Panel - Four Sided Framed Opening
Jamb Trim Installation
PU06029
00Jan '12
PBU Wall Panel - Three Sided Framed Opening
Jamb Trim Field Cut Details
PU07027
00Jan '12
PBU Wall Panel - Three Sided Framed Opening
Jamb Trim Installation
PU07029
00Jan '12
TYP. SECTION @ BASE OF PARTITION WALLSTYP. SECTION @ TOP OF PARTITION WALLS
TYP. OUTSIDE CORNER AT PARTITION WALLS TYP. INSIDE CORNER AT PARTITION WALLS
TYP. 'J' TRIM AT PARTITION WALL OPENINGS
TYP. INSIDE CORNER W/ VERTICAL &
HORIZONTAL PANELS
TYP. 'J' TRIM AT PARTITION WALL OPENINGS
TYP. INSIDE CORNER W/ VERTICAL PARTITION
PANELS AT INSULATED LINER PANEL
PBU Liner At Inside Corner UL01002
May '12 02
MA270402
Sep '12 01
Transverse Partition Panel Layout
Roof Slope 1:12 or Less
2-WS-01APPLICATION:
COMMERCIAL & INDUSTRIALC&I WINDOW SILL DETAIL
REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
2H-JT-01APPLICATION:
COMMERCIAL & INDUSTRIALC&I SIDE JOINT DETAIL
REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
2-DJ-01APPLICATION:
COMMERCIAL & INDUSTRIALC&I DOOR JAMB DETAIL
REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
2-DH-01APPLICATION:
COMMERCIAL & INDUSTRIALC&I DOOR HEADER DETAIL
REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE
APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS.
CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS.
CF-42, CF-36 FLUTE/MESA
CF-42, CF-36, CF-30 MESA/MESA
CF-36A, CF-30A ARCHITECTURAL FLAT/MESA
2-JT-01APPLICATION:
COMMERCIAL & INDUSTRIALCF PANEL JOINT DETAILS
thickness of steel. Fasteners will not achieve full pull-out strength if improper
Through Fasteners: Appropriate drill size must be used through different
(exterior profile only), flute plug material must be installed in the flutes. Cut
Flute Plug Material: Wherever sealant tape runs perpendicular to panel flute
1 1/2" strips and set in bed of urethane caulk or use continuous strip of flute plug.
size hole is drilled.
married into the butyl caulk in the panel joints.
through the sealant tape. Sealant tape applied to the ends of panel must be
to form watertight seal. All fasteners penetrating the flashings must be inserted
Butyl Sealant Tape: Must be applied between flashing and panel continually
end conditions. Butyl Caulk must not be used where it will be exposed to weather.
must be married into sealant tape running perpendicular to the joint at panel
Butyl Caulk: To be applied in the female grooves of the panel joint. Butyl caulk
SEALANTS, FASTENERS,
AND CLOSURE MATERIALS
CI-INFOAPPLICATION:
COMMERCIAL & INDUSTRIAL
(HW549)
(HW508)
(7609NGR)