Loading...
15-Division 13000 Special ConstructionDate Page Rev. R1 01May '12 Erection Guide Date Page Rev. R2 01Feb '12 Erection Guide Date Page Rev. R3 01May '12 Erection Guide Date Page Rev. R4 00Jan '12 Erection Guide Primary Frame Detail Interior Beam Column PF03002 May '12 01 Corner Column Girt Connection Partially Open Sidewall and Endwall EF02008 Apr '11 01 Bearing Frame Endwall Bypass with Bolted Girt - End Post not at Peak EF07001 Dec '12 03 Bearing Frame Endwall Bypass without Girt - End Post not at Peak EF07004 Dec '12 02 EF07018Bearing Frame Endwall - Bypass without Girt End Post with Column Extension at Inner Flange not at Peak Dec '12 02 End Post to Bridge Clip Connection Hot Rolled Bridge Channel EF09003 Feb '11 01 Type 1 Connection End Post located in Purlin Foul Zone EF09009 Feb '11 01 End Frame Detail Rigid End Frame With By-pass Girts Column Extension On Inner Flange EF08018 Dec '12 01 Cable Brace Attachment at Web PF04111 Nov '11 00 By-Pass Girt to Column "Optional" Liner Connection - Flange Brace FB4_ CF01202 Mar '11 01 By-Pass Girt to Column "Optional" Liner Connection - Flange Brace FB6_ or FB7_ CF01205 Mar '11 01 Cee Girt to Column "Optional" Liner Connection - Flange Brace FB4_ CF01208 Mar '11 01 Purlin to Rafter - Bolted Flange Standard Connection - Flange Brace FB4_ CF02060 Dec '10 00 Purlin to Rafter - Bolted Flange Standard Connection - Flange Brace FB6_ or FB7_ CF02063 Dec '10 00 CP04101 Sep '12 01 Flush Transverse Partition - Corner Girt Connections Aligned and/or Non-Aligned Partition Girt with Bypass Sidewall Girt PF04120 00May '12 Spandrel Beam Unbraced Beam to Other Construction Pre-Assembled Walk Door Anchor Placement AC05110 Dec '11 00 534" Walk Door Installation w/ Framed Opening AC05122 Dec '11 00 PBU Wall Panel - Walk Door & Glass-Front Walk Door Trim Installation with Field Notch Panel at Head Trim PU09022 Dec '11 00 PBU Wall Panel - Walk Door & Glass- Front Walk Door Field Notch Panel at Head Trim PU09023 Dec '11 00 PBU Wall Panel - Walk Door & Glass-Front Walk Door Trim Installation with Field Notch and Bend Tabs at Head Trim PU09024 Dec '11 00 PBU Wall Panel - Walk Door & Glass-Front Walk Door Field Notch and Bend Tabs at Head Trim PU09025 Dec '11 00 PBU Wall Panel - Walk Door & Glass-Front Walk Door Jamb Trim Field Cut Details PU09027 Dec '11 00 PBU Wall Panel - Preassembled Walk Door & Glass-Front Walk Door Jamb Trim Installation PU09029 Dec '11 00 PBU Wall Panel - Preassembled Walk Door & Glass-Front Walk Door Head Trim Installation PU09030 Dec '11 00 AC05113 Dec '11 00 Walk Door Head Detail Preassembled Door - PBR Liner Panel AC05114 Dec '11 00 Walk Door Jamb Detail Preassembled Door - PBR Liner Panel PBU Wall Panel - Four Sided Framed Opening Trim Installation with Field Notch Panel at Head Trim PU06022 00Jan '12 PBU Wall Panel - Four Sided Framed Opening Field Notch Panel at Head Trim PU06023 00Jan '12 PU06024PBU Wall Panel - Four Sided Framed Opening Trim Installation with Field Notch and Bend Tabs at Head Trim 00Jan '12 PBU Wall Panel - Four Sided Framed Opening Field Notch and Bend Tabs at Head Trim PU06025 00Jan '12 PBU Wall Panel - Four Sided Framed Opening Sill Trim Installation PU06026 00Jan '12 PBU Wall Panel - Four Sided Framed Opening "Optional" Channel Closure Trim PU06028 00Jan '12 PBU Wall Panel - Four Sided Framed Opening Head and Sill Trim Installation PU06030 00Jan '12 PBU Wall Panel - Three Sided Framed Opening Trim Installation with Field Notch Panel at Head Trim PU07022 00Jan '12 PBU Wall Panel - Three Sided Framed Opening Field Notch Panel at Head Trim PU07023 00Jan '12 00 PU07024PBU Wall Panel - Three Sided Framed Opening Trim Installation with Field Notch and Bend Tabs at Head Trim Jan '12 00 PBU Wall Panel - Three Sided Framed Opening Field Notch and Bend Tabs at Head Trim PU07025 Jan '12 PBU Wall Panel - Three Sided Framed Opening "Optional" Channel Closure Trim PU07028 00Jan '12 PBU Wall Panel - Three Sided Framed Opening Head Trim Installation PU07030 00Jan '12 AVP / PBA Wall Panel Installation Fastener Spacing PA05004 Mar '13 03 AVP / PBA Wall Panel Panel End Lap PA05011 Mar '13 01 PBU Wall Panel - Four Sided Framed Opening Jamb Trim Field Cut Details PU06027 00Jan '12 PBU Wall Panel - Four Sided Framed Opening Jamb Trim Installation PU06029 00Jan '12 PBU Wall Panel - Three Sided Framed Opening Jamb Trim Field Cut Details PU07027 00Jan '12 PBU Wall Panel - Three Sided Framed Opening Jamb Trim Installation PU07029 00Jan '12 TYP. SECTION @ BASE OF PARTITION WALLSTYP. SECTION @ TOP OF PARTITION WALLS TYP. OUTSIDE CORNER AT PARTITION WALLS TYP. INSIDE CORNER AT PARTITION WALLS TYP. 'J' TRIM AT PARTITION WALL OPENINGS TYP. INSIDE CORNER W/ VERTICAL & HORIZONTAL PANELS TYP. 'J' TRIM AT PARTITION WALL OPENINGS TYP. INSIDE CORNER W/ VERTICAL PARTITION PANELS AT INSULATED LINER PANEL PBU Liner At Inside Corner UL01002 May '12 02 MA270402 Sep '12 01 Transverse Partition Panel Layout Roof Slope 1:12 or Less 2-WS-01APPLICATION: COMMERCIAL & INDUSTRIALC&I WINDOW SILL DETAIL REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. 2H-JT-01APPLICATION: COMMERCIAL & INDUSTRIALC&I SIDE JOINT DETAIL REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. 2-DJ-01APPLICATION: COMMERCIAL & INDUSTRIALC&I DOOR JAMB DETAIL REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. 2-DH-01APPLICATION: COMMERCIAL & INDUSTRIALC&I DOOR HEADER DETAIL REFER TO SHEET "CI-INFO" FOR ADDITIONAL INFORMATION REGARDING THE APPLICATION OF SEALANTS, FASTENERS, AND CLOSURE MATERIALS. CONSULT METL-SPAN TO DETERMINE ALLOWABLE LOAD AND SPACING OF ATTACHMENT FASTENERS. CF-42, CF-36 FLUTE/MESA CF-42, CF-36, CF-30 MESA/MESA CF-36A, CF-30A ARCHITECTURAL FLAT/MESA 2-JT-01APPLICATION: COMMERCIAL & INDUSTRIALCF PANEL JOINT DETAILS thickness of steel. Fasteners will not achieve full pull-out strength if improper Through Fasteners: Appropriate drill size must be used through different (exterior profile only), flute plug material must be installed in the flutes. Cut Flute Plug Material: Wherever sealant tape runs perpendicular to panel flute 1 1/2" strips and set in bed of urethane caulk or use continuous strip of flute plug. size hole is drilled. married into the butyl caulk in the panel joints. through the sealant tape. Sealant tape applied to the ends of panel must be to form watertight seal. All fasteners penetrating the flashings must be inserted Butyl Sealant Tape: Must be applied between flashing and panel continually end conditions. Butyl Caulk must not be used where it will be exposed to weather. must be married into sealant tape running perpendicular to the joint at panel Butyl Caulk: To be applied in the female grooves of the panel joint. Butyl caulk SEALANTS, FASTENERS, AND CLOSURE MATERIALS CI-INFOAPPLICATION: COMMERCIAL & INDUSTRIAL (HW549) (HW508) (7609NGR)