Loading...
Norrthampton Housing Agency, Hampton Heights, Roofs(1)T BUILDING 4 ALTERNATE 2 B R I D G E R O A D J A C K S O N S T R E E TE N T R Y D R I V E BUILDING 1 BUILDING 2 BUILDING 3 ALTERNATE 1 BUILDING 5 BUILDING 6 (TYPE B) BUILDING 19 BUILDING 13 BUILDING 14 BUILDING 18 BUILDING 15 BUILDING 17 BUILDING 11 BUILDING 12 BUILDING 10 BUILDING 9BUILDING 8 BUILDING 7 EX. LOW-SLOPE ROOF N.I.C. BUILDING 16 REPLACE EX. ROOF N.I.C. SITE PLAN NOT TO SCALE, 1"= APPROX. 3,000'-0"B A B B B B B A ALTERNATE • REPLACE EX. ROOF B B PROJECT SITE, HAMPSHIRE HEIGHTS LOCATION MAPA TITLE, LOCATION MAP,ABBREVIATIONS, LIST OF DRAWINGS LIST OF DRAWINGS T - TITLE, LOCATION MAP, LIST OF ABBREVIATIONS, LIST OF DRAWINGS 1 - ROOF PLANS - BUILDING TYPES, PART. ELEVATION, ROOF DETAILS NORTHAMPTON HOUSING AUTHORITY MA DCHD PROJECT 214099 ROOF REPLACEMENT, 200-1, HAMPSHIRE HEIGHTS FAMILY HOUSING DEVELOPMENT Chair Joseph DeFazio Vice Chair Jeffrey Jones Treasurer Ronald Hebert Governor’s Appointment Toni Hochstadt Member Lynne Wallace NORTHAMPTON HOUSING AUTHORITY BOARD OF COMMISSIONERS EXECUTIVE DIRECTOR CARA CLIFFORD REVISIONSNORTHAMPTON HOUSINGAUTHORITY49 Old South StreetNorthampton MA 01060REPLACE/REPAIR ROOFSHAMPSHIRE HEIGHTS,02/22/2016G R E E N R I V E RA R C H I T E C T U R E11 HICKORY HILL ROAD • EGREMONT • MA 01230 (413) 528-1108 • grarchitecture@me.comDonald Pulfer • AIA CPHC® ROOF PLANS - BUILDING TYPES,PART. ELEVATION, ROOF DETAILS1 ROOF PLAN, BUILDING TYPE A Scale: 1/8" = 1'-0"A ROOF PLAN, BUILDING TYPE B Scale: 1/8" = 1'-0"B4'-0"TYP ATEAVES3'-0" TYP AT RAKES LOW SLOPETPO MEMBRANESHINGLES SHINGLES RIDGE VENT, TYPCHIMNEY, TYP VENT • NEW BOOT (TYP) EX EXH VENT (TYP) LOW SLOPETPO MEMBRANESHINGLES SHINGLES 3'- 0 "TYP ATVALLEYSONE STORY ENTRY ROOF SECOND STORY ROOF 132'-0"21'-8"10'-0"4'-8"15'-0"28'-8"4'-6"25'-0"SLOPE 8:12 (TYP) SLOPE 8:12 (TYP) SLOPE 8:12 (TYP) RIDGE VENT, TYP RIDGE VENT, TYPEED TYP TYP TYP TYP ATEAVESTYP AT RAKES LOW SLOPETPO MEMBRANESHINGLES SHINGLES RIDGE VENT, TYP CHIMNEY, TYP VENT • NEW BOOT (TYP)TYP ATVALLEYS4'-0"3'-0"3'-0"ONE STORY ENTRY ROOF SECOND STORY ROOF EX. EXH VENT (TYP) 89'-6" 15'-0"4'-6"28'-8"25'-0"SLOPE 8:12 (TYP) SLOPE 8:12 (TYP) SLOPE 8:12 (TYP) RIDGE VENT, TYPRIDGE VENT, TYP E E D TYP TYP TYP TYP CL EE PART. ENTRY ELEV. BLDG TYPE A (TYPE B SIM.) Scale: 1/8" = 1'-0"C EXISTING PENETRATION • VENT STACK PRE-MANUF ROOF FLASHING SET IN MASTIC NEW SHINGLES SET FLASHING IN MASTIC PROVIDE MASTIC @ SHINGLE/FLASHING JOINT CHECK FLASHING FOR TIGHT SEAL ROOF PENETRATION DETAIL Scale: 1 1/2" = 1'-0"D HOT AIR WELD TPO MEMBRANE CUT EDGE SEALANT DRIP EDGE EX PORCH STRUCTURE EX WD SHEATHING UNDERLAYMENT, ABOVE TPO MEMBRANE, SHINGLE FASHION SHINGLED ROOF EXTEND TPO MEMBRANE UNDER MIN. (3) SHINGLE COURSES TPO MEMBRANE SEALANT TERMINATION BAR WATER CUT-OFF MASTIC TPO MEMBRANE 4"ENTRY PORCH DETAIL Scale: 1 1/2" = 1'-0"E PART SECTION @ EAVE DETAIL @ SHINGLE / TPO INTERSECTION PART SECTION @ BLDG WALL REVISIONSNORTHAMPTON HOUSINGAUTHORITY49 Old South StreetNorthampton MA 01060REPLACE/REPAIR ROOFSHAMPSHIRE HEIGHTS,02/22/2016G R E E N R I V E RA R C H I T E C T U R E11 HICKORY HILL ROAD • EGREMONT • MA 01230 (413) 528-1108 • grarchitecture@me.comDonald Pulfer • AIA CPHC®