32C-162 Roof Structure 04.02.2018 Field Report: #1 Sent Via: Emily@estesarchitect.com Page 1 of 3 Date: April 2, 2018 Attention: Emily Estes Principal Estes Architecture + Design, LLC Project: Roberto’s Restaurant Renovations Job Number: 17194 General Contractor: Keiter Builders Weather: Clear, Mid-50s Present: Amy Jagaczewski (GNCB), Stefan Barry (Keiter) GNCB visited the site on Thursday, March 29, 2018 from 10:30am to 11:30am to review the progress of construction and verify roof framing details. The following was observed and discussed: 1. GNCB reviewed localized areas of the fire-damaged framing at the south end of the building. The fire-damage does not appear to be deeper than ¼” at any of the framing members reviewed. Keiter has already sistered the damage rafters with 2x6s attached with screws. This is acceptable. 2. The remaining, non-fire-damaged roof rafters require sisters as well to support modern Code-required snow-loads. The remaining rafters should be sistered with 2x6s fastened with the same screws pattern Keiter has installed at the south side of the building. 3. Keiter has installed 2x4 ceiling framing at every other rafter along with 2x4 diagonals up to the roof rafters at approximately 3rd points. At alternating rafters, they have also installed 2x4 collar ties up high near the ridge. This pattern should be repeated for the length of the roof. 4. All sistered rafters should be fastened to the top plate with mechanical anchorage. Simpson A35 clips with a bent leg or Simpson hurricane clips are acceptable. 5. The 3-LVL beam for the enlarged opening is in the process of being installed. Currently, two plies are in place. Studs have been built up at either end per structural requirements. The south jack/king studs are supported at the existing foundation wall. The north jack/king studs land outboard of the existing basement wall. Keiter intends to install a lally column in the basement at this location. This is acceptable. 6. See annotated photographs for additional information. Roberto’s Restaurant Renovations Field Report #1 April 2, 2018 Page 2 of 3 Submitted by: Amy Jagaczewski, P.E. Copies to: Sent via: Alex Lunt (Keiter) alunt@keiterbuilders.com Photo P01: Typical reinforcing at south end of roof. Photo P02: 2 plies of 3-LVL header at enlarged opening are installed. Roberto’s Restaurant Renovations Field Report #1 April 2, 2018 Page 3 of 3 Photo P03: Rafter sisters and diagonals at third-points to be installed at remaining roof framing. Photo P04: Anchor sistered rafters to top plates.