Loading...
Retail Area Calc 4HAMPSHIRE FIRE PROTECTION LLC 507 Southampton Road Westfield, MA 01085 413-642-3287 Job Name : Retail Area Building : Location : 155 Pleasant Street System : Area # 4 Contract : 0292CMA Data File : Retail Area Area 4.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLC Page 1 Retail Area Date HYDRAULIC CALCULATIONS for Project name:Live 155 Location:155 Pleasant Street Drawing no: Date:1-19-17 Design Remote area number:Area # 4 Remote area location:First Floor Retail Area Occupancy classification:Ordinary Hazard Group II Density:.20 - Gpm/SqFt Area of application:1261 - SqFt Coverage per sprinkler:Varies - SqFt Type of sprinklers calculated:Reliable QR Brass Upright No. of sprinklers calculated:13 In-rack demand:N/A - GPM Hose streams:250 - GPM Total water required (including hose streams):564.20 - GPM @ 61.69 - Psi Type of system:Wet System Volume of dry or preaction system:N/A - Gal Water supply information Date:2-4-16 Location:Pleasant Street Source:Northampton city water system Name of contractor:Hampshire Fire Protection Address:507 Southampton Road Westfield, MA. Phone number:(413) 642-3287 Name of designer:SAS Authority having jurisdiction:Northampton Water Department Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLCPage 2 Retail AreaDate 10203040E50R60U70S80S90E100R110P120130140150200 400 600 800 1000 1200 1400 1600 1800FLOW ( N ^ 1.85 )City Water Supply:Demand:C1C2C1 - Static Pressure : 130 C2 - Residual Pressure: 122 C2 - Residual Flow : 1220 D1 - Elevation : 5.630 D2 - System Flow : 314.201 D2 - System Pressure : 61.693 Hose ( Demand ) : 250 D3 - System Demand : 564.201 Safety Margin : 66.386 D1D2D3Water Supply Curve CComputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLCPage 3 Retail AreaDate Fitting Legend Abbrev. Name ½ ¾ 1 1¼ 1½ 2 2½ 3 3½ 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 00000111122345678101113 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zca Colt C200 Horz Butt Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Fittings Used SummaryComputer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLC Page 4 Retail Area Date SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 130.0 122 1220.0 128.079 564.2 61.693 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 401 13.0 5.6 19.3 24.6 R6 12.0 20.88 R7 12.0 22.84 T2 12.0 25.55 T3 9.67 41.14 T6 9.67 41.5 305 9.67 43.44 100.0 ST5 9.667 44.1 RT1 9.667 44.37 RB1 2.0 51.25 RB2 2.0 58.69 RB3 2.0 59.93 TEST 0.0 61.69 150.0 402 13.0 5.6 14.1 21.03 R1 12.0 15.39 R2 12.0 15.72 R3 12.0 16.93 R4 12.0 21.15 T1 12.0 25.0 403 13.0 5.6 14.42 21.26 404 13.0 5.6 15.56 22.09 405 13.0 5.6 17.58 23.48 R5 12.0 19.07 406 13.0 5.6 19.1 24.47 R8 12.0 20.66 R9 12.0 21.23 R10 12.0 23.28 T4 12.0 26.06 T5 12.0 26.47 407 13.0 5.6 19.41 24.67 R11 12.0 21.0 R12 12.0 21.57 R13 12.0 23.65 408 13.0 5.6 19.63 24.81 409 13.0 5.6 19.56 24.77 410 13.0 5.6 19.95 25.01 411 13.0 5.6 21.16 25.76 412 13.0 5.6 21.58 26.01 413 13.0 5.6 21.93 26.23 Flow Summary - NFPA 2007 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLC Page 5 Retail Area Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 401 24.60 1.049 T 5.0 1.000 19.297 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R6 24.6 0.1908 0.0 6.000 1.145 Vel = 9.13 R6 23.48 1.38 0.0 11.330 20.875 to 120.0 0.0 0.0 0.0 R7 48.08 0.1734 0.0 11.330 1.965 Vel = 10.31 R7 25.76 1.38 T 6.0 1.070 22.840 to 120.0 0.0 6.000 0.0 T2 73.84 0.3836 0.0 7.070 2.712 Vel = 15.84 T2 89.15 2.157 3E 18.46 9.760 25.552 to 120.0 T 12.307 51.688 4.009 * * Fixed Loss = 3 T3 162.99 0.1885 B 7.384 61.448 11.583 Vel = 14.31 S 13.537 Fsp 0.0 T3 0.0 4.26 2E 26.334 25.160 41.144 to 120.0 0.0 26.334 0.0 T6 162.99 0.0069 0.0 51.494 0.353 Vel = 3.67 T6 151.21 4.26 2E 26.334 31.440 41.497 to 120.0 T 26.334 52.668 0.0 305 314.2 0.0231 0.0 84.108 1.941 Vel = 7.07 305 100.00 4.26 E 13.167 3.910 43.438 Qa = 100 to 120.0 0.0 13.167 0.001 ST5 414.2 0.0385 0.0 17.077 0.657 Vel = 9.32 ST5 0.0 6.357 T 37.72 11.583 44.096 to 120.0 0.0 37.720 0.0 RT1 414.2 0.0055 0.0 49.303 0.271 Vel = 4.19 RT1 0.0 4.26 E 13.167 1.375 44.367 to 120.0 Fsp 0.0 13.167 6.321 * * Fixed Loss = 3 RB1 414.2 0.0384 0.0 14.542 0.559 Vel = 9.32 RB1 0.0 4.26 Zca 0.0 0.916 51.247 to 120.0 0.0 0.0 7.410 * * Fixed Loss = 7.41 RB2 414.2 0.0382 0.0 0.916 0.035 Vel = 9.32 RB2 0.0 4.26 B 15.8 3.083 58.692 to 120.0 E 13.167 28.967 0.0 RB3 414.2 0.0385 0.0 32.050 1.234 Vel = 9.32 RB3 0.0 6.357 E 23.412 90.000 59.926 to 140.0 2T 100.336 128.765 0.866 TEST 414.2 0.0041 G 5.017 218.765 0.901 Vel = 4.19 150.00 Qa = 150.00 564.20 61.693 K Factor = 71.83 402 21.03 1.049 T 5.0 1.000 14.102 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R1 21.03 0.1428 0.0 6.000 0.857 Vel = 7.81 R1 0.0 1.38 0.0 8.830 15.392 to 120.0 0.0 0.0 0.0 R2 21.03 0.0375 0.0 8.830 0.331 Vel = 4.51 R2 21.26 1.38 0.0 8.830 15.723 to 120.0 0.0 0.0 0.0 R3 42.29 0.1368 0.0 8.830 1.208 Vel = 9.07 Final Calculations - Hazen-Williams - 2007 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLC Page 6 Retail Area Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn R3 22.09 1.38 2E 6.0 8.190 16.931 to 120.0 0.0 6.000 0.0 R4 64.38 0.2976 0.0 14.190 4.223 Vel = 13.81 R4 24.77 1.38 T 6.0 1.070 21.154 to 120.0 0.0 6.000 0.0 T1 89.15 0.5434 0.0 7.070 3.842 Vel = 19.12 T1 0.0 2.157 0.0 9.000 24.996 to 120.0 0.0 0.0 0.0 T2 89.15 0.0618 0.0 9.000 0.556 Vel = 7.83 0.0 89.15 25.552 K Factor = 17.64 403 21.26 1.049 T 5.0 1.000 14.416 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R2 21.26 0.1457 0.0 6.000 0.874 Vel = 7.89 0.0 21.26 15.723 K Factor = 5.36 404 22.09 1.049 T 5.0 1.000 15.560 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R3 22.09 0.1563 0.0 6.000 0.938 Vel = 8.20 0.0 22.09 16.931 K Factor = 5.37 405 23.48 1.049 T 5.0 1.000 17.583 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R5 23.48 0.1750 0.0 6.000 1.050 Vel = 8.72 R5 0.0 1.049 0.0 10.330 19.066 to 120.0 0.0 0.0 0.0 R6 23.48 0.1751 0.0 10.330 1.809 Vel = 8.72 0.0 23.48 20.875 K Factor = 5.14 406 24.47 1.049 T 5.0 1.000 19.096 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R8 24.47 0.1892 0.0 6.000 1.135 Vel = 9.08 R8 0.0 1.38 0.0 11.330 20.664 to 120.0 0.0 0.0 0.0 R9 24.47 0.0497 0.0 11.330 0.563 Vel = 5.25 R9 24.81 1.38 0.0 11.330 21.227 to 120.0 0.0 0.0 0.0 R10 49.28 0.1816 0.0 11.330 2.057 Vel = 10.57 R10 26.02 1.38 T 6.0 0.970 23.284 to 120.0 0.0 6.000 0.0 T4 75.3 0.3976 0.0 6.970 2.771 Vel = 16.15 T4 0.0 2.157 0.0 9.150 26.055 to 120.0 0.0 0.0 0.0 T5 75.3 0.0451 0.0 9.150 0.413 Vel = 6.61 T5 75.91 2.157 4E 24.613 9.320 26.468 to 120.0 T 12.307 57.841 4.009 * * Fixed Loss = 3 T6 151.21 0.1641 B 7.384 67.161 11.020 Vel = 13.28 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLC Page 7 Retail Area Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn S 13.537 Fsp 0.0 0.0 151.21 41.497 K Factor = 23.47 407 24.67 1.049 T 5.0 1.000 19.411 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R11 24.67 0.1918 0.0 6.000 1.151 Vel = 9.16 R11 0.0 1.38 0.0 11.330 20.995 to 120.0 0.0 0.0 0.0 R12 24.67 0.0505 0.0 11.330 0.572 Vel = 5.29 R12 25.02 1.38 0.0 11.330 21.567 to 120.0 0.0 0.0 0.0 R13 49.69 0.1843 0.0 11.330 2.088 Vel = 10.66 R13 26.22 1.38 T 6.0 0.970 23.655 to 120.0 0.0 6.000 0.0 T5 75.91 0.4036 0.0 6.970 2.813 Vel = 16.28 0.0 75.91 26.468 K Factor = 14.75 408 24.81 1.049 T 5.0 1.000 19.630 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R9 24.81 0.1940 0.0 6.000 1.164 Vel = 9.21 0.0 24.81 21.227 K Factor = 5.38 409 24.77 1.049 T 5.0 1.000 19.561 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R4 24.77 0.1933 0.0 6.000 1.160 Vel = 9.20 0.0 24.77 21.154 K Factor = 5.39 410 25.01 1.049 T 5.0 1.000 19.953 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R12 25.01 0.1968 0.0 6.000 1.181 Vel = 9.28 0.0 25.01 21.567 K Factor = 5.39 411 25.76 1.049 T 5.0 1.000 21.160 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R7 25.76 0.2078 0.0 6.000 1.247 Vel = 9.56 0.0 25.76 22.840 K Factor = 5.39 412 26.01 1.049 T 5.0 1.000 21.580 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R10 26.01 0.2118 0.0 6.000 1.271 Vel = 9.66 0.0 26.01 23.284 K Factor = 5.39 413 26.23 1.049 T 5.0 1.000 21.933 K Factor = 5.60 to 120.0 0.0 5.000 0.433 R13 26.23 0.2148 0.0 6.000 1.289 Vel = 9.74 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 HAMPSHIRE FIRE PROTECTION LLC Page 8 Retail Area Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 26.23 23.655 K Factor = 5.39 Final Calculations - Hazen-Williams Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087