Loading...
LIVE 155 FP2 1-25-17SDSDF FFLEXTELE/DATA116NORTH ENTRY118120ALL GENDERTOILETRETAIL121119MEN'STOILETWOMEN'STOILET117122MAINTENANCEELECTRICAL123124001LOADINGRETAIL002RETAILRETAIL003004115MECHANICAL113SOUTH ENTRYOPEN OFFICEOFFICE111BHAPRECEPTION111A2-1111STAIR 2UNASSIGNED3-1STAIR 3125CONFERENCE111CBEDROOM109BLIVING109AENTRY109BATHROOM109DKITCHEN109CENTRY110BATHROOM110DLIVING110AKITCHEN110CƒHOODQGƒHOOBACK TO BACK212" HOSE VALVE212" HOSE VALVE564.20 GPM at 61.69PSIDemand at Base of Riser414.2 GPM at 59.92 PSIHYDRUALIC REMOTE AREA # 413 Sprinklers OperatingDensity .20 GPM Over 1261 Sq. FT.250 GPM for hose streamTotal Demand at City Main701.20 GPM at 118.60 PSIDemand at Base of Riser551.2 GPM at 116.11 PSIHYDRUALIC REMOTE AREA # 514 Sprinklers OperatingDensity .20 GPM Over 983 Sq. FT.250 GPM for hose streamTotal Demand at City Main393.05 GPM at 96.68 PSIDemand at Base of Riser393.05 GPM at 93.881 PSIHYDRUALIC REMOTE AREA # 311 Sprinklers OperatingDensity .10 GPM Over 902 Sq. FT.100 GPM for hose streamTotal Demand at City MainLOBBY100LAUNDRY114LIFE SAFETY116AJAN112ENTRY107ENTRY105ENTRY103ENTRY101BATHROOM107DBATHROOM105DBATHROOM103DBATHROOM101DBATHROOM102DBATHROOM106DBATHROOM104DBATHROOM108DKITCHEN108CKITCHEN106CKITCHEN104CKITCHEN102CLIVING107ALIVING105ALIVING103ALIVING101AKITCHEN107CKITCHEN105CKITCHEN101CKITCHEN103CBEDROOM110BBEDROOM108BLIVING108AENTRY108ENTRY106ENTRY104ENTRY102LIVING106ALIVING104ALIVING102ABEDROOM106BBEDROOM104BBEDROOM102BBEDROOM107BBEDROOM105BBEDROOM105BBEDROOM103BBEDROOM101BKITCHEN111DSERVICEHALL0051235781'-9"19'-012"6'-9"44'-11"68'-812"12'-10"6'-0"4'-312"22'-4"18'-3"18'-312"22'-4"ABDEFG18'-012"22'-012"22'-0"22'-4"22'-3"211918171615AC141312119101918171620226'-4"21'-212"4'-11"19'-612"8'-0"NOPQRS7'-11" 5'-0" 4'-3" 9'-412" 1'-0" 4'-11"HIJJ.1KLM1-1STAIR 1PIPE SLOPING UP TOLANDINGPIPE SLOPING DOWNUNDER STAIRSFIRST FLOOR FIRE PROTECTION PLAN18" = 1'-0"CPVC EXPANSIONLOOP6" x 4" STORZ FIRE DEPT CONNECTION2" FLOOR CONTROL ASSEMBLY (SEE FP-1 FOR DETAIL)2" BUTTERFLY VALVE2" CHECK VALVE2" FLOW SWITCH1" TEST & DRAIN(4 TYPICAL FOR RETAIL AREAS)2 1/2" FLOOR CONTROL ASSEMBLY2 1/2" BUTTERFLY VALVE2 1/2" CHECK VALVE2 1/2" FLOW SWITCH1 1/4" TEST & DRAIN(SEE FP-1 FOR DETAIL)1 1/2" FLOOR CONTROL ASSEMBLY1 1/2" BUTTERFLY VALVE1 1/2" CHECK VALVE1 1/2" FLOW SWITCH1" TEST & DRAIN(SEE FP-1 FOR DETAIL)PER B.E.R. ENGINEERINGSPRINKLERS ARE NOTREQUIRED UNDER EXTERIORPROJECTIONSPER B.E.R. ENGINEERINGSPRINKLERS ARE NOTREQUIRED UNDER EXTERIORPROJECTIONS4" BUTTERFLY VALVE w/ BUILT-IN TAMPER SWITCH4" BUTTERFLY VALVE w/ BUILT-IN TAMPER SWITCH4" STANDPIPE FEED UP TO 2ND FLOOR4" BUTTERFLY VALVE w/BUILT-IN TAMPER SWITCH4" STANDPIPE w/2 12" HOSE VALVENO A.S.PER MANUFACTURER'S REQUIREMENTSSPRINKLER HEADS IN RESIDENTIAL UNITSCAN BE MAXIMUM 9'-0" OFF WALLS AND 18'-0"BETWEEN SPRINKLER HEADS9'-0"8'-012"9'-0"4" STANDPIPE w/2 12" HOSE VALVESEE NOTE # 14