24D-183 16051536BEWPCalcs6-6-16SealsThis truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
diff
1
4 3/8"
2
21' 6 1/2"4 3/8"
22' 3 1/4"
Graphical Illustration - Not To Scale
Loading (psf):Quick Design Summary:Quick Deflection Summary:
Live Load Deflection 0-08 @ 11-01-10 L/480Roof Live Load - 20 Building Code - IBC 2009
Total Load Deflection 0-12 @ 11-01-10 L/240Design Methodology - ASDRoof Dead Load - 10
Critical Moment (Pos)Passed - 68%Floor Live Load - 40
Critical Shear Passed - 53%Floor Dead Load - 20
Unbraced Length (Top/Bottom) - 0-00/21-06-08
Reactions:
Maximum Analysis Reactions
Support Start End Dead Floor Live Roof Live Snow
1 0-00 4-06 299.00 lb 599.00 lb --
2 21-10-14 22-03-04 299.00 lb 599.00 lb --
Forces:
Maximum Load Magnitudes
Type Start End Dead Floor Live Roof Live Snow
Uniform 0-00 22-03-04 27.00 lb/ft 53.00 lb/ft --
Expanded Design Results:
Design Control Result LDF Load Combination
Critical Moment (Pos)4707.27 lb ft @ 11-01-10 6965.04 lb ft Passed - 68%1.00 D + L
Critical Shear 861.25 lb @ 4-07 1625.00 lb Passed - 53%1.00 D + L
Live Load Deflection 0-08 @ 11-01-10 L/480 Passed - L/507 -L
Total Load Deflection 0-12 @ 11-01-10 L/240 Passed - L/338 -D + L
Errors, Warnings & Notes:
*The dead loads used in the design of this member were applied to the structure as sloped dead loads.
*The member graphic, dimensions, and locations shown on this report are based on the centerline of the member.
*Analysis and Design has been performed using precision loading from actual modeled conditions. Some loads may have been modified to simplify reporting.
Job ID: 16051536B Status: Design Passed
Job Name:Project Name
Label: J1-16" O.C.
Member Type: FloorJoist | Level: 1st Floor Page: 1 of 4
Member: 1 - 11-7/8" LPI 42Plus @ 16"Date: 06/06/2016 08:30:03
-Transfer reactions may differ from design results as allowed per building codes and standard load distribution practices.
-This report is based on modeled conditions input by the user. Actual field conditions may differ from those shown. These results should be reviewed by a qualified design professional.
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
diff am LV
1
2
3' 6"4 3/8"
3' 10 3/8"
Graphical Illustration - Not To Scale
Loading (psf):Quick Design Summary:Quick Deflection Summary:
Live Load Deflection 0-00 @ 1-09-09 L/360Roof Live Load - 20 Building Code - IBC 2009
Total Load Deflection 0-00 @ 1-09-09 L/240Design Methodology - ASDRoof Dead Load - 10
Critical Moment (Pos)Passed - 5%Floor Live Load - 40
Critical Shear Passed - 12%Floor Dead Load - 15
Unbraced Length (Top/Bottom) - 0-00/1-01-08
Reactions:
Maximum Analysis Reactions
Support Start End Dead Floor Live Roof Live Snow
1 0-00 0-00 159.00 lb 297.00 lb --
2 3-06-00 3-10-06 168.00 lb 313.00 lb --
Forces:
Maximum Load Magnitudes
Type Start End Dead Floor Live Roof Live Snow
Self Weight 0-00 3-10-06 6.00 lb/ft ---
Uniform 2-05-15 3-06-00 1.00 lb/ft 3.00 lb/ft --
Uniform 3-06-00 3-10-06 -3.00 lb/ft --
Point 1-01-15 1-01-15 151.00 lb 302.00 lb --
Point 2-05-15 2-05-15 152.00 lb 304.00 lb --
Connector Information:
Nailing Requirements
Support Manufacturer Model Top Face Member Min Seat Length Other Information
1 USP THF17925 -8- 10d Common 2- 10d x 1 1/2 N/A -
Expanded Design Results:
Design Control Result LDF Load Combination
Critical Moment (Pos)525.57 lb ft @ 1-01-15 9951.26 lb ft Passed - 5%1.00 D + L
Critical Shear 468.05 lb @ 2-06-02 3948.44 lb Passed - 12%1.00 D + L
Live Load Deflection 0-00 @ 1-09-09 L/360 Passed - L/999 -L
Total Load Deflection 0-00 @ 1-09-09 L/240 Passed - L/999 -D + L
Errors, Warnings & Notes:
*The dead loads used in the design of this member were applied to the structure as sloped dead loads.
*The member graphic, dimensions, and locations shown on this report are based on the centerline of the member.
*Analysis and Design has been performed using precision loading from actual modeled conditions. Some loads may have been modified to simplify reporting.
Job ID: 16051536B Status: Design Passed
Job Name:Project Name
Label: B2
Member Type: Beam | Level: 1st Floor Page: 2 of 4
Member: 1 - 1-3/4x11-7/8 LP-LVL 2900Fb-2.0E Date: 06/06/2016 08:30:03
-Transfer reactions may differ from design results as allowed per building codes and standard load distribution practices.
-This report is based on modeled conditions input by the user. Actual field conditions may differ from those shown. These results should be reviewed by a qualified design professional.
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
diff am LV
1
4 3/8"
2
21' 6 1/2"4 3/8"
22' 3 1/4"
Graphical Illustration - Not To Scale
Loading (psf):Quick Design Summary:Quick Deflection Summary:
Live Load Deflection 0-10 @ 11-00-12 L/360Roof Live Load - 20 Building Code - IBC 2009
Total Load Deflection 1-00 @ 11-00-14 L/240Design Methodology - ASDRoof Dead Load - 10
Critical Moment (Pos)Passed - 61%Floor Live Load - 40
Critical Shear Passed - 23%Floor Dead Load - 15
Unbraced Length (Top/Bottom) - 0-00/11-04-12
Reactions:
Maximum Analysis Reactions
Support Start End Dead Floor Live Roof Live Snow
1 0-00 4-06 382.00 lb 621.00 lb --
2 21-10-14 22-03-04 329.00 lb 513.00 lb --
Forces:
Maximum Load Magnitudes
Type Start End Dead Floor Live Roof Live Snow
Self Weight 0-00 22-03-04 6.00 lb/ft ---
Uniform 0-00 11-10-14 24.00 lb/ft 48.00 lb/ft --
Uniform 11-10-14 21-10-14 12.00 lb/ft 25.00 lb/ft --
Point 11-10-00 11-10-00 159.00 lb 297.00 lb --
Point 21-10-14 21-10-14 8.00 lb 16.00 lb --
Expanded Design Results:
Design Control Result LDF Load Combination
Critical Moment (Pos)6085.86 lb ft @ 11-10-00 9951.26 lb ft Passed - 61%1.00 D + L
Critical Shear 893.27 lb @ 1-04-04 3948.44 lb Passed - 23%1.00 D + L
Live Load Deflection 0-10 @ 11-00-12 L/360 Passed - L/413 -L
Total Load Deflection 1-00 @ 11-00-14 L/240 Passed - L/256 -D + L
Errors, Warnings & Notes:
*The dead loads used in the design of this member were applied to the structure as sloped dead loads.
*The member graphic, dimensions, and locations shown on this report are based on the centerline of the member.
*Analysis and Design has been performed using precision loading from actual modeled conditions. Some loads may have been modified to simplify reporting.
Job ID: 16051536B Status: Design Passed
Job Name:Project Name
Label: B1
Member Type: Beam | Level: 1st Floor Page: 3 of 4
Member: 1 - 1-3/4x11-7/8 LP-LVL 2900Fb-2.0E Date: 06/06/2016 08:30:03
-Transfer reactions may differ from design results as allowed per building codes and standard load distribution practices.
-This report is based on modeled conditions input by the user. Actual field conditions may differ from those shown. These results should be reviewed by a qualified design professional.
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
diff
1
4 3/8"
2
11' 4 3/4"
11' 9 1/8"
Graphical Illustration - Not To Scale
Loading (psf):Quick Design Summary:Quick Deflection Summary:
Live Load Deflection 0-01 @ 6-00-04 L/480Roof Live Load - 20 Building Code - IBC 2009
Total Load Deflection 0-02 @ 6-00-04 L/240Design Methodology - ASDRoof Dead Load - 10
Critical Moment (Pos)Passed - 34%Floor Live Load - 40
Critical Shear Passed - 30%Floor Dead Load - 20
Unbraced Length (Top/Bottom) - 0-00/11-04-12
Reactions:
Maximum Analysis Reactions
Support Start End Dead Floor Live Roof Live Snow
1 0-00 4-06 159.00 lb 318.00 lb --
2 11-09-02 11-09-02 152.00 lb 304.00 lb --
Forces:
Maximum Load Magnitudes
Type Start End Dead Floor Live Roof Live Snow
Uniform 0-00 11-09-02 26.00 lb/ft 52.00 lb/ft --
Connector Information:
Nailing Requirements
Support Manufacturer Model Top Face Member Min Seat Length Other Information
2 USP TFL25118 6- 10d Common -2- 10d x 1 1/2 N/A -
Expanded Design Results:
Design Control Result LDF Load Combination
Critical Moment (Pos)1281.69 lb ft @ 6-00-05 3755.02 lb ft Passed - 34%1.00 D + L
Critical Shear 446.65 lb @ 11-09-01 1485.00 lb Passed - 30%1.00 D + L
Live Load Deflection 0-01 @ 6-00-04 L/480 Passed - L/999 -L
Total Load Deflection 0-02 @ 6-00-04 L/240 Passed - L/999 -D + L
Design Notes:
*The required bearing length for this member is the same for both with and without web stiffeners (108)
Errors, Warnings & Notes:
*The dead loads used in the design of this member were applied to the structure as sloped dead loads.
*The member graphic, dimensions, and locations shown on this report are based on the centerline of the member.
*Analysis and Design has been performed using precision loading from actual modeled conditions. Some loads may have been modified to simplify reporting.
Job ID: 16051536B Status: Design Passed
Job Name:Project Name
Label: J2-16" O.C.
Member Type: FloorJoist | Level: 1st Floor Page: 4 of 4
Member: 1 - 11-7/8" LPI 20Plus @ 16"Date: 06/06/2016 08:30:03
-Transfer reactions may differ from design results as allowed per building codes and standard load distribution practices.
-This report is based on modeled conditions input by the user. Actual field conditions may differ from those shown. These results should be reviewed by a qualified design professional.