74 Bridge St closeout
The Commonwealth of Massachusetts
City of Northampton
Certificate of Occupancy
In accordance with 780 CMR (The 8th Edition of the Massachusetts State Building Code),
this Certificate of Occupancy is issued to the premise or structure or part thereof as herein identified.
Issued to
Identify Name of Building of Space Within Certificate No.
Unique Lodging, LLC
BP-2018-0010
Located at
Identify property address including street number, name, city or town and county
74 Bridge St
Northampton, Hampshire, Massachusetts
Use Group
Classification(s)
4 Units Townhouse Multi-family Residential
This Certificate of Occupancy is hereby issued by the undersigned to certify that the premise, structure or portion thereof as herein specified has been inspected for general fire and life safety features. This certificate shall allow for the use as herein described and in conformance with any and all conditions as identified below. It
shall be posted in a conspicuous place within the space as directed by the undersigned. Failure to post the certificate, failure to comply with conditions or,
tampering with the contents of the certificate is strictly prohibited.
Conditions of Use
This certificate allows occupancy of all residential units
All means of egress must be kept clear and accessible. All fire protection and life safety systems must be maintained and
functional at all times.
Name of Municipal Building Official Louis Hasbrouck Date of Final Inspection 07/31/2018 Map/Plot:
Signature of Municipal Building Official
Date of Issuance 07/31/2018 32A-177
74 BRIDGE ST
GIS #:
Map:Block: 32A -177
BP-2018-0010
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
=....;:Pe=rm=it"-: --=B=ui=ld=in::.w.g DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category: renovation BUILDING PERMIT
Permit # BP-2018-0010
Project # JS-2017-001098
Est. Cost: $117500.00
Fee: $826.00 PERMISSION IS HEREBY GRANTED TO:
Const. Class:
Use Group:
Lot Size(sq. ft.): 22999.68
Zoning: URC(l00)/
Contractor: License:
PIONEER CONTRACTORS 017890
Owner: UNIQUE LODGING LLC
Applicant: PIONEER CONTRACTORS
AT: 74 BRIDGE ST
Applicant Address: Phone: Insurance:
PO Box 1145 (413) 586-5491 Workers Compensation
NORTHAMPTONMA01061 ISSUED ON:10/26/2017 0:00:00
to PERFORM THE FOLLOWING WORK:CONVERT SPACE INTO 2 RESIDENTIAL UNITS
PER PLANS -INTERIOR RENOVATION: HERS 55 rating required for final inspection
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
f;f'·
Underground: Service: Meter:
Rough:.J/~.J J ~ough: J ., }, ?--· 1 s-1
V/l/t't 3 ~ 7'-Q P,_,.
~, ~al:/ Final: 7-/f.-/i
ft::{~9//T ~ f?_p--.__
'5~1-f
House#
Footings:
Foundation:
Driveway Final:
Rough Frame: CJ k Q 5/ Z ,j If'
Gas: Fire Deoartment Fireplace/Chimney:
~ ,~ })~+ Insulation:
IJl<ff/Pe-cpv;/J,t:;fJ ,J I,~ oJCfttJD~ µcQS FD
Final: ~ Smoke: °7{ if{ I~ Final: 7{,ra / t £1 b Ct-1
FttvA-(.;/G<J 7{?ri (1B L..+\
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANYOFITSRULESAND GU~AT!O~. ~ /f=v.,~~
Certificate of Occu ~ Si nature: C7<J...
FeeType:
Builc:ling
Date Paid: Amount:
10/26/2017 0:00:00 $826.00
21 2 Main Street, Phone (413) 587-1 240, Fax: (4 13) 587-1272
Louis Hasbrouck -Building Commissioner
Home Energy Rating Certificate Final Report Rating Date: 2018-07-28 Registry ID: 347995010 Ekotrope ID: VVngRVD2 HERS® Index Score: Annual Savings 4 8 Your home's HERS score Is a relative performance score. The lower the number, the more energy efficient the home. To learn more, visit www.herslndex.com $1,148 *Relative to an average U.S. home Your Home's Estimated Energy Use: Heating Cooling Hot Water Lights/ Appliances Service Charges Generation (e.g. Solar) Total: lSO Ellisting a 140 Homes 130 uo 110 Reference H Home 1.00 90 80 70 :_. •o This lfam, JO lO Zero Enl!rgy • lO Home o 4»01Jtt'.s.f .... LenEfWf'IY Use [MBtu] 14.8 0.5 4.9 9.3 0.0 29.5 Annual Cost $192 $28 $64 $491 $204 -$0 $979 Home Feature Summary: Home Type: Townhouse, inside unit Conditioned Floor Area: 769 sq. ft. Number of Bedrooms: Primary Heating System: Primary Cooling System: Primary Water Heating: House Tightness: Ventilation: Radiant Floor Hydronic • Natural Gas, 95 AFUE Air Source Heat Pump, Electric• 7.4 EER Water Heater• Natural Gas• 0.96 Energy Factor 451 CFM50 (256 ACH50) 22.7 CFM •9.0Watts Duct Leakage to Outside: 0 CFM25 Above Grade Walls: R-20 Ceiling: Vaulted Roof, R-49 Window Type: Foundation Walls: U-Value: 0.290, SHGC: 0.320 NIA Home: 74 Bridge St. #3, Northampton, MA 01060 Builder: David Claxton This home meets or exceeds the criteria of the following: 2015 International Energy Conservation Code Rating Completed by: Energy Rater.Adin Maynard RESNET ID:9463452 Rating Company:HIS & HERS Energy Efficiency Mailing: 12 Perkins Ave. Northampton MA 01060 4136588784 Rating Provider.Energy Raters of Massachusetts ~~ Adin Maynard, Certified Energy Rater Digitally signed: 7/31/18 at 8:58 AM
IECC 2015 Label
74 Bridge St #3
HERS® Index Score: 48
Ceiling: R-49
Above Grade Walls: R-20
Foundation Walls: NIA
Exposed Floor: R-38
Slab: R-10
Infiltration: 451 CFMSO (2.56 ACHSO)
Duct Insulation: R-6
Duct Leaka e: 0 CFM25
Window: U = 0.290, SHGC = 0.320
Door: R-5
Heating: Radiant Floor Hydronic • Natural Gas•
95 AFUE
Cooling: Air Source Heat Pump • Electric • 7 .4
EER
Hot Water: Water Heater • Natural Gas • 0.96
Ener Factor
Air Leakage Report
Property Organization
74 Bridge St #3
Northampton, MA 01060
HIS & HERS Energy Effici1
4136588784 Inspection Status
2018-07-28
74Bridge_#3 center unit
74Bridge St-Unit3 Center
Adin Maynard
Builder
David Claxton
Rater ID (RTIN): 9463452
RESNET Registered (Confirmed)
General Information
Conditioned Floor Area [sq. ft] 769
Infiltration Volume [cu. ft] 10,565
Number of Bedrooms 1
Air Leakage
Measured Infiltration 451 CFM50 (2.56 ACH50)
ACH50 (Calculated) 2.56
ELA [sq. in.] (Calculated) 24.8
ELA per 100 s.f. Shell Area (Calculated) 0.789
CFM50 (Calculated) 451
Duct Leakage
System 1
Leakage to Outdoors [CFM @ 25 Pa] 0.0
Leakage to Outdoors [CFM25 / 100 s.f.] 0.0
Leakage to Outdoors [CFM25 / CFA] 0.000
Total Leakage Test Type Post-Construction
Total Leakage [CFM @ 25 Pa] 0.0
Total Leakage [CFM25 / 100 s.f.] 0.0
Total Leakage [CFM25 / CFA] 0.000
Mechanical Ventilation
Rate [CFM] 22.7
Hours per day 24.0
Fan Watts 9.0
Recovery Efficiency % 0.0
Runs at least once every 3 hrs? true
Average Rate [CFM] 22.7
2010 ASHRAE 62.2 Req. Cont Ventilation 22.7
2013 ASHRAE 62.2 Req. Cont Ventilation 38.1
Ekotrope RATER -Version 3.1.0.1976
RESNET HOME ENERGY
RATING Standard Disclo ure
For home(s) located at: 74 Bridge St. #3, Northampton, MA
Check the applicable disclosure(s) in accordance with he instructions on the reverse of this page:
§a 1. The Rater or the Rater's employer is receiving a fee f r providing the rating on this home.
0 2. In addition to the rating, the Rater of Rater's employer han also provided the following consulting services for
this home:
0 A. Mechanical system design
D B. Moisture control or indoor air quality consultin,
0 C. Performance testing and/or commissioning o er :han required for the rating itself
D D. Training for sales or construction personnel
0 E. Other(specify)
0 3. The Rater of the Rater's employee is:
0 A. The seller of this home or their agent
0 B. The mortgagor for some portion of the financed payments on this home
0 C. An employee, contractor, or consultant of the t.lectric and/or natural gas utility serving this home
0 4. The Rater or Rater's employer is a supplier or installe~ of products, which may include:
Products Installed in this home by OR is in the business of
HVAC systems []Rater Q Employer Q Rater Q Employer
Thermal insulation systems []Rater 0 Employer 0 Rater Q Employer
Air sealing of envelope or duct systems []Rater Q Employer O Rater Q Employer
Energy efficient appliances (]Rater Q Employer Q Rater Q Employer
Construction (builder, developer, construction contractor, eti :) []Rater 0 Employer O Rater 0 Employer
Other (specify): []Rater O Employer O Rater Q Employer
Os. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Ra ing Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification#: 9463452
Name: Adin Maynard Signature: __ ___....~"'-"'-.......... -~--~-, ____ _
Organization: HIS & HERS Energy Efficiency Digitally signed: 7/31 /18 at 8:58 AM -------------
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Serv ices Network(RESNET). The national rating quality
control provisions of the rating standard are contained i Chapter One 4.C.8. of the standard and are posted at
http://resnet.us/standards/RESNET _Mortgage_lndustry_National_HERS_Standards.pdf
The Home Energy Rating Standard Disclosure for thi!, home is available from the rating provider.
RESNET Form 03001-2 -Amended April 24, 2007
Home Energy Rating Certificate Final Report Rating Date: 2018-07-28 Registry ID: 522112727 Ekotrope ID: pdWPZJOv HERS® Index Score: Annual Savings 51 Your home's HERS score Is a relative performance score. The lower the number, the more energy efficient the home. To learn more, visit www.herslndex.com $1,235 *Relative to an average U.S. home Your Home's Estimated Energy Use: Heating Cooling Hot Water Lights/ Appliances Service Charges Generation (e.g. Solar} Total: Exi!ting Homes Reference Hom!! Zero Energy Homl! eiontuNO ..... """'""''II' 150 W> 130 uo 110 100 90 80 : ..... so--.:l,1-,o JI} 20 to 0 This Home lff,[_.., Use [MBtu] 23.1 0.6 4.9 9.3 0.0 37.9 Annual Cost $302 $31 $64 $491 $204 -$0 $1,091 Home Feature Summary: Home Type: Townhouse, end unit Conditioned Floor Area: 769 sq. ft Number of Bedrooms: Primary Heating System: Primary Cooling System: Primary Water Heating: House Tightness: Radiant Floor Hydronic, Natural Gas, 95 AFUE Air Source Heat Pump• Electric· 7 A EER Water Heater• Natural Gas• 0.96 Energy Factor 350 CFMSO (1.99 ACHSO) Ventilation: 22.7 CFM • 9.0 Watts Duct Leakage to Outside: 0 CFM25 Above Grade Walls: R-20 Ceiling: Vaulted Roof, R-49 Window Type: U-Va lue: 0.290, SHGC: 0.320 Foundation Walls: NIA Home: 74 Bridge St. #4, Northampton, MA 01060 Bullder: David Claxton This home meets or exceeds the criteria of the following: 2015 International Energy Conservation Code Rating Completed by: Energy Rater:Adln Maynard RESNET ID:9463452 Rating Company:HIS & HERS Energy Efficiency Mailing: 12 Perkins Ave. Northampton MA 01060 413658B7B4 Rating Provider.Energy Raters of Massachusetts ~~ Adin Maynard, Certified Energy Rater Digitally signed: 7/31/1 Bat 9:00 AM
IECC 2015 Label
74 Bridge St. #4
HERS® Index Score: 51
Ceiling: R-49
Above Grade Walls: R-20
Foundation Walls: NIA
Exposed Floor: R-38
Slab: R-10
Infiltration: 350 CFM50 (1.99 ACH50)
Duct Insulation: R-6
Duct Leakage: 0 CFM25
Window: U = 0.290, SHGC = 0.320
Door: R-5
Heating: Radiant Floor Hydronic • Natural Gas •
95 AFUE
Cooling: Air Source Heat Pump• Electric• 7.4
EER
Hot Water: Water Heater • Natural Gas • 0.96
Ener Factor
or
Si nature:
Air Leakage Report
Property Organization
7 4 Bridge St #4
Northampton, MA 01060
HIS & HERS Energy Effici1
4136588784 Inspection Status
2018-07-28
74Bridge_#4 end unit
74Bridge St-Unit4 End
Adin Maynard
Builder
David Claxton
Rater ID (RTIN): 9463452
RESNET Registered (Confirmed)
General Information
Conditioned Floor Area [sq. ft.] 769
Infiltration Volume [cu. ft] 10,565
Number of Bedrooms 1
Air Leakage
Measured Infiltration 350 CFM50 (1.99 ACH50)
ACH50 (Calculated) 1.99
ELA [sq. in.] (Calculated) 19.3
ELA per 100 s.f. Shell Area (Calculated) 0.612
CFM50 (Calculated) 350
Duct Leakage
System 1
Leakage to Outdoors [CFM @ 25 Pa] 0.0
Leakage to Outdoors [CFM25 / 100 s.f.] 0.0
Leakage to Outdoors [CFM25 / CFA] 0.000
Total Leakage Test Type Post-Construction
Total Leakage [CFM @ 25 Pa] 0.0
Total Leakage [CFM25 / 100 s.f.] 0.0
Total Leakage [CFM25 / CFAJ 0.000
Mechanical Ventilation
Rate [CFMJ 22...7
Hours per day 24.0
Fan Watts 9.0
Recovery Efficiency % 0.0
Runs at least once every 3 hrs? true
Average Rate [CFMJ 22.7
2010 ASHRAE 62.2 Req. Cont Ventilation 22...7
2013 ASHRAE 62.2 Req. Cont Ventilation 38.1
Ekotrope RATER -Version 3.1.0.1976
RESNET HOME ENERGY
RATING Standard Disclo ure
For home(s) located at: 74 Bridge St. #41. Northamp ton, MA
Check the applicable disclosure(s) in accordance with the instructions on the reverse of this page:
~1. The Rater or the Rater's employer is receiving a fee for p -oviding the rating on this home.
0 2. In addition to the rating, the Rater of Rater's employe1 ha:; also provided the following consulting services for
this home:
D A. Mechanical system design
D B. Moisture control or indoor air quality consultin{
D C. Performance testing and/or commissioning other than required for the rating itself
D D. Training for sales or construction personnel
D E. Other(specify)
Os. The Rater of the Raters employee is:
D A. The seller of this home or their agent
D B. The mortgagor for some portion of the financed p:1.yments on th is home
D C. An employee, contractor, or consultant of the le<:tric and/or natural gas utility serving this home
0 4. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products Installed in this home by OR is in the business of
HVAC systems f]Rater Q Employer O Rater Q Employer
Thermal insulation systems f ]Rater 0 Employer Q Rater Q Employer
Air sealing of envelope or duct systems f ]Rater Q Employer Q Rater 0 Employer
Energy efficient appliances !]Rater Q Employer Q Rater O Employer
Construction (builder, developer, construction contractor, et ) !]Rater Q Employer Q Rater Q Employer
Other (specify): !]Rater Q Employer Q Rater O Employer
Q s. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification#: 94634S2
Name: Adin Maynard Signature: __ ___..~~"""'--~-~------
Organization: HIS & HERS Energy Efficiency C,igitally signed: 7/31/18 at 9:00 AM -------------
I attest that the above information is true and correc to tie best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions f ttie Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy ServiceH Network(RESNET). The national rating quality
control provisions of the rating standard are contained inChapter One 4.C.8. of the standard and are posted at
http://resnet.us/standards/RESNET _Mortgage_l ndustry_National_H ERS_Standards.pdf
The Home Energy Rating Standard Disclosure for thi,> home is available from the rating provider.
RESNET Form 03001-2 -Amended April 24, 2007