Loading...
32A-177 (4)City of Northampton Mail - RE: 74 Bridge Street RE: 74 Bridge Street 1 message Duane Nichols <dnichols@northamptonma.gov> To: Charles Miller <cmiller@northamptonma.gov> https://mail.google.com/mail/?W=2&ik--3921 lafc3d&view=pt&search... Chuck, Yes, I am CK with issuing the permit and plans approved before rough. Thanks Duane From: Charles Miller [mailto:cmiller@northamptonma.gov] Sent: Thursday, September 12, 2013 1:56 PM To: Duane Nichols Subject: 74 Bridge Street Hi Duane, Charles Miller <cmiller@northamptonma.gov> Thu, Sep 12, 2013 at 2:40 PM The builder is getting ready to start the work on this building. We have the code review, sprinklers and alarms are required and expected. The issue we are running into is the sprinklers systems are becoming more often design build scenarios so the design isn't available at the initial start up. Would you be OK with us issuing the building permit contingent on the sprinkler plans being approved before our rough inspection. The builder is dependable and competent. Thanks, Chuck Miller Assistant Building Commissioner City of Northampton Town of Williamsburg (City of Northampton E-mail is a public record except when it falls under one of the specific statutory exemptions.) (City of Northampton E-mail is a public record except when it falls under one of the specific statutory exemptions.) 1 of 1 9/12/2013 3:11 PM If you find this proposal acceptable, please sign and date below and return to our office. We thank you for the opportunity to quote and hope we may be of further service to you on this project. If you have any questions regarding this quotation, please contact me at our office: 413- 536-9222 Sincerely, Tiw1 L2wreK6e James Lawrence Warehouse Mechanical Contractors, Inc. AGREED: CUSTOMER: Todd Marchefka SELLER: Warehouse Mechanical Contractors, Inc Printed Name: Printed Name: 342 Britton Street - Chicopee, MA. 01020 Tel. (413) 536-9222 FAX (413) 535-2486 MA. Lic. 2254 & R1. 329 aur DEPT_OF E UILDINC pc r' WAREHOUSE MECHANICAL ANICAL t.EO ` 1 ■\4-IACTORS. INC. A certified Service Disabled Veteran Owned Small Business Sprinkler Contractors and Designers Established 1980 December 6, 2012 Todd Marchefka Re: College Inn of Northampton -Northampton, MA. Gentlemen: We are pleased to offer our quotation in the amount of to furnish and install an automatic fire sprinkler system at the above reverenced project based on starting at a flushed and tested 4" flanged outlet left by others inside the building. Our price is based on plans as prepared by Thomas Douglas Architects dated 3-28-11. Our price includes sprinkler.drawings & preparation of fire protection sprinkler documents in accordance with 901.2.1 Eighth Edition of the Massachusetts State Building Code, Massachusetts State sales tax, concealed pipe with white or chrome recessed pendent or sidewall sprinklers in areas with suspended ceilings or in soffits, exposed pipe with brass upright sprinklers in all other areas, backflow preventer, control valves, now switch, inspector's test connection, wet sprinkler system, design for NFPA 13 and all necessary pipe, valves and fittings. Adequate heat must be provided in all areas of the building. We have excluded exterior piping, painting of pipe, soffits, wiring, alarm systems, fire extinguishers, the premium portion of overtime labor and special protection other than wet pipe sprinkler protection. Warranty and Disclaimer Seller warrants that any products supplied in connection with its services shall be free from defects in workmanship or material for a period of three (3) years from the date of delivery (the "Warranty Period"). During the Warranty Period, provided Seller is promptly notified upon the discovery of any defect in workmanship or material, Seller agrees to, at Seller's option, either repair or replace defective products. Payment Terms 20% down payment 35% upon delivery of materials 25% upon completion of sprinkler piping rough in 20% upon final completion and acceptance Code Review Thomas Douglas Architects Inc 74 Bridge Street, Northampton, MA 196 Pleasant St. Northampton, MA 413-585-0641 3.3.2 If the work performed, including the exempted work, amounts to 30% or more of the full and fair cash value of the building, the entire building is required to comply with 521 CMR. This project's construction costs will not exceed 30% of the assessed value of the entire building. The construction cost will not exceed $1oo,000. The existing first floor will not be altered to provide an accessible front door. None of the common spaces will need to be altered. • End of Document MM Code Review Thomas Douglas Architects Inc 74 Bridge Street, Northampton, MA 196 Pleasant St. Northampton, MA 413-585-0641 • 903.2.8 Group R: An NFPA 13R automatic sprinkler system shall be provided throughout all buildings with a Group R fire area. The fire alarm vendor will supply a fire alarm narrative. 711 Energy Conservation Required values according to the MA stretch code for this Existing building: MA: climate zone 5A Existing windows will not be retained in the attic space. The new work area in the attic will be fully air sealed. All existing ceilings, walls or floor cavities of the building envelope exposed or accessible during construction will be filled with insulation that meets or exceeds an R -value of R-3.5 per inch. The roof will be insulated and air sealed. Any new replacement windows will have a maximum U value of 0.4 Any new entrance doors will have a maximum U value of o.8 Level 3 alterations are permitted without requiring the entire building to comply with the International Energy Conservation Code. Alterations (new construction) shall comply with the International Energy Conservation Code. A building that undergoes Level 3 alterations is required to meet a certain level of energy compliance. Any new element within the work area is required to meet the International Energy Conservation Code. Elements within the building that are not being affected do not heed to be evaluated and do not nee to comply with the energy provisions. Essentially the entire building is not required to meet the energy provisions; only a degree of possible improvement in the energy performance of the building is intended to be achieved by making the new elements meet the IECC. In certain cases where the reconfiguration of the space might have resulted in the creation of new spaces the newly created space should be evaluated as a whole for compliance with the energy provisions even though some of the element within the space might actually not have been altered. Likewise, in a case where an existing mechanical system is being extended to other areas or new ductwork is being installed to reconfigure and reroute the ducts to various spaces, it is only required to have the new elements meet the energy provisions and not the entire system. 8o6 Accessibility CMR 521 3.3.1 b. If the work costs $ioo,000 or more, then the work being performed is required to comply with 521 CMR. In addition, an accessible public entrance and an accessible toilet room shall be provided. 7 of 8 Code Review Thomas Douglas Architects Inc 74 Bridge Street, Northampton, MA 196 Pleasant St. Northampton, MA 413-585-0641 1022 Exit Enclosures Interior exit stairways and interior exit ramps shall be enclosed with Fire Barriers constructed in accordance with 707. Exit enclosures shall have a fire resistance rating of not less than 1 hour where connecting less than 4 stories. This building has an existing interior and exterior exit stair less than 4 stories and we estimate that the interior walls have a fire resistance of 1 hour. The rating of the existing doors is unknown. Exception: Stairs in apartments: Stairways serving and contained within a single residential dwelling unit or sleeping unit in Group R1, R2, or R3 are not required to be enclosed. The new egress stair for this attic project will connect the owners unit on the first floor and it will not be enclosed. It will be separated from the other units and exits in the building. 1208.2 Minimum Ceiling Height requirements Minimum required ceiling height: 7'-6" If any room in a building has a sloped ceiling, the prescribed ceiling height for the room is required in 1/i of the area. Any portion of the room measuring less than 5 feet from the finished floor to the ceiling shall not be included in any computation of the minimum area thereof. 1029 Emergency Escape and Rescue Exception 1 in section 1029 allows sprinkler systems (NFPA 13 and 13R systems) to be used in lieu of emergency escape and rescue openings. 805.2 Means of Egress Lighting Means of egress lighting will be installed throughout the entire building 805.3 Exit signs Means of egress throughout the entire building will have exit signs installed. 705.4.2 Door swing. All means of egress doors will swing in the direction of travel. 1008.1-10,705-4.4 Panic hardware: Not required since this is not an A or E or H use. Chapter 9 Fire Protection Systems: 6 of 8 Code Review Thomas Douglas Architects Inc 74 Bridge Street, Northampton, MA 196 Pleasant St. Northampton, MA 413-585-0641 have required impact insulation class (IIC) rating of not less than 50. See the construction drawings for code compliant assemblies. • See drawings for STC wall details and ratings. Means of E>;ress Section ioog.i prescribes that the width of an interior stairway cannot be less than 44 inches ioog.i Exception i allows a reduction in width to 36 inches if serving an occupant load of less than 50. This new egress stair will serve an occupant load of less than 50. The new stair will be 3'-0" wide from attic to 2nd floor. The continuation of this stair from 2nd to ls` floor exists. 1118.2 Corridor Width The required corridor width for this project (with an occupancy of less than 50) is 36". Widths of corridors in this project vary, but the most narrow corridor in this project is 3'-8". 1018.4 Dead ends With an NFPA 13R automatic sprinkler system, dead end corridors are limited to 20 feet. This project does not have dead end corridors exceeding 20 feet. 1015 Exit and Exit Access Doorways, 1021 Number of exits and continuity In group R2 and R3 occupancies, one means of egress is permitted within and from individual dwelling units with a maximum occupant load of 20 where the dwelling unit is equipped throughtout with an automatic sprinker system of NFPA 13 and 13R systems. The attic space of this project is within an existing dwelling unit and does not require 2 means of egress. 1o16a Travel Distance • Exit access travel distance (1016.1) 250 feet, but modified by 1021.2 below. This distance is the same for NFPA 13 and 13R systems. Travel With NO With sprinkler Proposed max travel Distance sprinkler System distance (1o16a) System Attic space 250' 74 feet from attic corner to 2nd floor exit stair 5 of 8 Code Review Thomas Douglas Architects Inc 74 Bridge Street, Northampton, MA 196 Pleasant St. Northampton, MA 413-585-0641 Furnace room: Where any piece of equipment is over 400,00o BTU per hour input, a 1 hour fire separation or sprinklers are required. Laundry rooms over loo square feet: a i -hour fire separation or sprinklers are required. Table 508.4 Required Separation of Occupancies • With a NFPA 13R sprinkler system and type 5B construction: • 420.2 Separation Walls: Walls separating dwelling units in the same building shall be constructed as fire partitions. • 709.1 Fire partitions, 709.3, ioiga, Fire Resistance rating, • i. Corridors: Corridor walls shall have a 1 -hour rating because of the NFPA 13R system. The exception allowed by table ioi8.1 is not in effect. • Dwelling unit and sleeping unit separations in buildings of type 213, 3B and 5B construction shall have fire resistance ratings of not less than i hour in buildings equipped with an NFPA 13R automatic sprinkler system. • 712.3 Horizontal Assemblies, Fire resistance rating: • Dwelling unit and sleeping unit separations in buildings of type 213, 3B and 5B construction shall have fire resistance ratings of not less than i hour in buildings equipped with an automatic sprinkler system. Fire separations required between R use and R use: None Required Interior Stairway enclosures. see Exit enclosures, 1022 below. 707.8 Penetrations: permitted by section 1022.4 1022.4 Penetrations into and openings through an exit enclosure are prohibited except for required exit doors, equipment and duct work necessary for independent ventilation or pressurization, sprinkler piping, standpipes, and electrical raceways serving the exit enclosure. 1207 Sound Transmission • 1207.2 Air -borne sound: Walls, partitions, and floor/ceiling assemblies separating dwelling units from each other or from public or service areas will be constructed to have required STC value of 50. See the construction drawings for code compliant assemblies. • 1207.3 Structure -borne sound: Floor/ceiling assemblies separating dwelling units from each other or from public or service areas will be constructed to 4 of 8 Code Review 74 Bridge Street, Northampton, MA Northampton, MA Thomas Douglas Architects Inc 196 Pleasant St. 413-585-0641 Fire Resistive Required Types of Building Element above grade. (502.1) Area Increase per floor from 5o6 (new allowed) Sprinklers & frontage o Primary Structural o Proposed Areas by Floor, gross Basement: 1991 First Floor 2014 Second Floor 2057 Third Floor 1626 TOTAL 7,688 Nonbearing walls and o Proposed Height R2 s ace partitions, interior 3 story, 45'-4" tall Floor construction and o Fire Resistive Required Types of Building Element Type 5B Construction, Table 6oi & 602 Primary Structural o Frame Bearing walls, Exterior o Bearing walls, Interior o Nonbearing walls and o partitions, exterior Nonbearing walls and o partitions, interior Floor construction and o secondary members Roof construction and o secondary members 508.4 707.3.8 Separated Occupancies There is only one proposed type of occupancy in this building. There are no separated occupancies. 508.4.2:Allowable building area: 5o6a Building area modifications: Building areas from Table 503 shall NOT be permitted to be increased due to frontage and sprinklers. FIRE SEPARATIONS: Table 508.2.5 Incidental Accessory Occupancies 3 of 8 Code Review 74 Bridge Street, Northampton, MA Northampton, MA Fire and Smoke Alarm & Detection Thomas Douglas Architects Inc 196 Pleasant St. 413-585-0641 A manual fire alarm system and an automatic smoke detection system will be installed throughout the building. An independent Fire Alarm Vendor will supply the final alarm plans and device specifications. Seismic Zone • See structural code review According to the IEBC this renovation is being reviewed as: Prescriptive Compliance Method, Chapter 3 303 Alterations: Alterations to any building or structure shall comply with the requirements of the IBC code for new construction. 303.3 Existing Structural elements: see attached structural review. Maximum Allowable Height/Area (section 503-506) Section 504.2, Automatic sprinkler increase, states that for Group R buildings equipped throughout with an approved sprinkler system in accordance with Section 903.3.1.2 (an NFPA 13R system) the maximum building height is increased by 20 feet and maximum number of stories is increased by 1 story but shall not exceed 4 stories and 6o ft. Section 506.3 does not allow an area increase for 13R systems. Type SB construction allows a building up to 7,000 square feet per floor. The largest floor of this building is 2,057 square feet and complies with maximum areas. The total allowable building area is calculated using the formula in section 506.4.1. For buildings 3 stories or more above grade, multiply the allowable building area per story from 506.1 by 3. The calculation is:7,000 sq ft per story x 3 = 21,000 square feet maximum building area. We propose a maximum building size of 7,688 square feet and complies with maximum areas. Maximum Allowable Height/Area Type 513 With NFPA 13R (section 503-5o6) Use: R2 sprinklers Maximum Height Allowed 2 story, 40 feet Maximum Area Allowed PER 7,000 FLOOR Height Increase per 5o6 (new Sprinklers & frontage 3 stories, 6o feet allowed) Note: the basement does not count as a story 2of8 Code Review 74 Bridge Street, Northampton, MA Northampton, MA CODE REVIEW Thomas Douglas Architects Inc 196 Pleasant St. May 16,2013 74 Bridge Street, Northampton, MA The Historic College Inn of Northampton Applicable Building Code: MA 78o CMR Eighth Addition IBC, IEBC International EXISTING Building Code, 2009 ZONING DISTRICT: 413-585-0641 PROPOSED_ RENOVATIONS: PROJECT DESCRIPTION: • Renovate the existing attic space of this multi -family residential building. Extend the existing owners unit into the existing 3'd floor attic space. Create a new egress stair for the unit. • Renovations of the building will include 1. Attic Floors: a. Repair existing floor framing b. Insulate all walls and the roof c. Install new paint, finish flooring, millwork d. Install new kitchenette and bath. e. Install new electrical, plumbing, and HVAC system. f. Install new fire alarm systems g. Install new NFPA 13R sprinkler system 2. Roof a. Install a new dormers and repair existing framing. b. Insulate to MA Stretch code Use Groups, Section 310 • R2. Non Transient Boarding House -No Changes proposed Construction Type • 5B Sprinkler System , , • The entire building will be fully sprinkled with a NFPA"UR,system. • An independent Sprinkler Vendor will supply the final plan and system specifications. 1 of 8 �ft+�t PT d �2i+tsaacffnsctla ' - DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ' Municipal Building ' Northampton, Mass. 01060 WORICER'S COMPENSA'nON INSURANCE AFFMAVTT I, Pioneer Contractors (licensttlpermitiec) `with a principal place of business/resideuce at-. P.O. ox 11 45 Northampton- MA n� 0AI —(Phone; B ) 52-6-54-91— do 06 5 91do hereby certify, under the pains and penalties of perjury, (�J dh-lt: I am an employer er Providin the folloWin worker's compensation sation covera e for in), employees worming on this job: Wcc 500595701 20GIZ AsAnniatpd Em—plovers Tnstlrarir`e On ---_ – (Insurancz. Company) (Policy Number) (Ex-piration Date) () I aln a sole proprietor, general contractor orhomeowuer (circle one) and have hired the contractors listed below who have the following worker's compensation policies'. (Name of Contractor) (Lasurance Company/PoUcy Numbcr) (FxTimtion Date) (Name of Contractor) (lastuance Company/PoUcy Number) (Expiradoa Date) (Name of Contrac(or) (Inaxaace Compawy/Policy Numb, -f) (Expimbon Date) (Name of Contractor) (lusumace Company/Policy Number) (E,)Tiration Date) (attach additional Shea ifucca=sy to inc}ude infocrosQon p.Uiniag to .0 oo.ftnewn) () I am a sole proprietor and have no one w,orldng for me. () I am a home owner performing all the work myself. NOTE: please be aw2rc that wble homeownctz who employ persons w do m int— noc coastrvaioc or repair work on a dw lting of not [note tben throe units is w Wch the boamwaer mida oc oa tb4 grounrh appuiiensr:d tbadD are not &cowdly coandaed to be employen under the wack ocmpcnsatioa Act (GLI 52,= 1(5)), applicabon by a homeowner for a liazlx or permit may evidcnoe the legal ctatua of an amployee under tfia Wocicaea Compeoaatioa AA;( - 1 und=it n that a. oopy of thin euI—as may be forwvxded to the Deparmaaoi of Iodar�rial Axidme! Offioo of Iuauznce for tha coves-ge vcrific ilioa and thst failure to eoatre eoveragv tinder souioa 25A of MGL 152 can lead to the k posid- oftaimiatl pca+ltics ooasivrag of a fine of up to S 1,5oo. oo aadror imprisoemxrd of up to one year and a vt7 pcaa.tUc3 is the form of a Stop W ark Ord and a fine o(5100.00 a day aptircA me r Foc dcp� trio only Permit Number Map# Lot #1 r f Si be of Liansce/Pcrmi e A Y: , ,- Versionl.7 Commercial Building Permit May 15, 2000 SECTION 10- STRUCTURAL PEER REVIEW (780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No SECTION 11 - OWNER AUTHORIZATION - TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Unique Lodgine LLC as Owner of the subject property hereby authorize Pioneer Contractors to act on my b n all matters relative to work authorized by this building permit application. 06/04/2013 Signature of Date David Claxton/Pioneer Contractors as6mmW/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate, to the best of my knowledge and belief. Signed under the pains and penalties of perjury., Print Name /e/ �/1 �C 06/04/2013 Signature of Owner/Agent l e9:eT1nN 19 - CnNRTRI ICTIM SERVICES Date 10.1 Licensed Construction Supervisor: Name of License Holder: David Claxton Not Applicable ❑ CS 017890 License Number P.O. Box 1145 01/19/2014 Address Expiration Date (413) 586-5491 Signature Telephone SECTION 13 -WORKERS' COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. ned Affidavit Attached Yes k!) No Versionl.7 Commercial Building Permit May 15, 2000 SECTION 9- PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES - FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 780 CMR 116 (CONTAINING MORE THAN 36,000 C.F. OF ENCLOSED SPACE) 9.1 Registered Architect: Thomas Douglas Architects Not Applicable ❑ Name (Registrant): Thomas Douglas Architects Registration Number Address Signature Telephone Expiration Date 9.2 Registered Professional Engineer(s): ;Jacob Smith Engineering & Design Structure Name So. Deerfield, MA Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Signature Telephone Registration Number Expiration Date Name Area of Responsibility Address Signature Telephone Registration Number Expiration Date Name Area of Responsibility Address Signature Telephone Registration Number Expiration Date 9.3 General Contractor Pioneer Contractors Not Applicable ❑ Company Name: ;David Claxton Responsible In Charge of Construction P.O. Box 1145 Northampton, MA. 01061 Address (413) 586-5491 Signature Telephone Versionl .7 Commercial Building Permit May 15, 2000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side Rear L: R: L: R:, Building Height Bldg. Square Footage % Open Space Footage (Lot area minus bldg & paved parking) # of Parking Spaces Fill: volume & Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW YES Q IF YES: enter Book Page and/or Document # B. Does the site contain a brook, body of water or wetlands? NO DON'T KNOW 0 YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained , Date Issued: C. Do any signs exist on the property? YES NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property ? YES NO Qi IF YES, describe size, type and location: E. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. Versionl.7 Commercial Building Permit May 15, 2000 SECTION 4- CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations ❑ Existing Wall Signs ❑ Demolition ❑ Repairs ❑ Additions ❑ Accessory Building ❑ Exterior Alteration ❑ Existing Ground Sign ❑ New Signs ❑ Roofing ❑ Change of Use ❑ Other ❑✓ Brief Description Enter a brief description here. Interior renovation per plans attached. Of Proposed Work: RFMInN s - use GROl1P AND CONSTRUCTION TYPE I SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor (sf) 1 St 1St e, 2nd 2nd 3d 3rd 4th 4th Total Area (so Total Proposed New Construction (sf) Total Height (ft) Total Height ft F ater Supply (M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: ic ❑i Private ❑ Zone Outside Flood Zone ❑✓ Municipal [Z] On site disposal system E] USE GROUP (Check as applicable) CONSTRUCTION TYPE A AssemblyE]A-1 A-4 El ❑ A-2 A-5 El ❑ A-3 E] 1A 1B ❑ B Business ❑ 2A 2B 2C ❑ I ❑ ❑ E Educational ❑ F Factory ❑ F-1 ❑ F-2 ❑ H Hi h Hazard ❑ 3A 3B ❑ ❑ Institutional ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ M Mercantile ❑ 4 ❑ R Residential ❑ R-1 ❑ R-2 ❑✓ R-3 ❑ 5A 5B ❑ ❑✓ S Storage ❑ S-1 ❑ S-2 ❑ U Utility ❑ Specify: Specify: M Mixed Use ❑ S Special Use ❑ Specify: COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS, ADDITIONS AND/OR CHANGE IN USE Existing Use Group: R-2 Existing Hazard Index 780 CMR 34):. Proposed Use Group: R-2 Proposed Hazard Index 780 CMR 34): I SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor (sf) 1 St 1St e, 2nd 2nd 3d 3rd 4th 4th Total Area (so Total Proposed New Construction (sf) Total Height (ft) Total Height ft F ater Supply (M.G.L. c. 40, § 54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: ic ❑i Private ❑ Zone Outside Flood Zone ❑✓ Municipal [Z] On site disposal system E] SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: 74 Bridge St. Map Lot Unit Zone Overlay District -- Elm St. DistrictCB District SECTION 2 - PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Unique Lodging LLC 74 Bridge St., Northampton, MA. 01060 Name (Print) Current Mailing Address: (413) 237-5555 Signature Telephone 2.2 Authorize e Pioneer tractors P.O. Box 1145 NOrthampton, MA 01061 Name (Print) Current Mailing Address: (413)586-5491 Signature Telephone SECTION 3 - ESTIMATED CONSTRUCTION COSTS Item Estimated Cost (Dollars) to be Official Use Only completed by permit applicant 1. Building $56,150.00 (a) Building Permit Fee 2. Electrical$8,400.00 (b) Estimated Total Cost of Construction from 6 3. Plumbing $6,300.00 Building Permit Fee - 4. Mechanical (HVAC) $23,000.00; 5. Fire Protection 6. Total = 0 +2+3+4+5) Check Number This Section For Official Use Only Building Permit Number Date Issued Signature: Date Building Commissioner/Inspector of Buildings File # BP -2013-1190 APPLICANT/CONTACT PERSON PIONEER CONTRACTORS ADDRESS/PHONE PO Box 1145 NORTHAMPTON (413) 586-5491 PROPERTY LOCATION 74 BRIDGE ST MAP 32A PARCEL 177 001 ZONE URC(100) THIS SECTION FOR OFFICIAL USE ONLY: Owner/ Statement or License 017890 3 sets of Plans / Plot Plan THE FOLLOWING ACTION HAS BEEN TXKEN ON THIS APPLICATION BASED ON IN ORMATION PRESENTED: Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Major Project: Site Plan AND/OR ZONING BOARD PERMIT REQUIRED UNDER: Finding Special Permit Special Permit With Site Plan Special Permit With Site Plan Variance* Received & Recorded at Registry of Deeds Proof Enclosed _Other Permits Required: Curb Cut from DPW Septic Approval Board of Health Water Availability Sewer Availability Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition elay Signature of Building Officirail Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning & Development for more information. 74 BRIDGE ST BP -2013-1190 GIs #: COMMONWEALTH OF MASSACHUSETTS Map:Block: 32A -177 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: INTERIOR DEMOLITION BUILDING PERMIT Permit # BP -2013-1190 Project # JS -2013-001834 Est. Cost: $93850.00 Fee: $1128.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Groin: PIONEER CONTRACTORS 017890 Lot Size(sg. ft.): 22999.68 Owner: UNIQUE LODGING LLC Zoning: URC(100) / Applicant: PIONEER CONTRACTORS AT. 74 BRIDGE ST AAglicant Address: Phone: Insurance: PO Box 1145 (413) 586-5491 Workers Compensation NORTHAMPTONMA01061 ISSUED ON. 9/16/2013 0:00:00 TO PERFORM THE FOLLOWING WORK. -INTERIOR RENOVATION - approved sprinkler plans before rgh insp POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Underground: Service: Rough: Rough: Final: Final: Gas: Fire Department Rough: Oil: Final: Smoke: Meter: House # Driveway Final: Building Inspector Footings: Foundation: Rough Frame: Fireplace/Chimney: Insulation: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType• Date Paid: Amount: Building 9/16/2013 0:00:00 $1128.00 212 Main Street, Phone (413) 587-1240, Fax: (413) 587-1272 Louis Hasbrouck — Building Commissioner