Loading...
17A-242 72 Lake Street Langlais 2018-10-12RampRampRamp New Addition New Breezeway DeckExistingExistingExistingExisting SHEET DESCRIPTION Cover Page DRAWN BY C. Bouwer DATE June 1, 2018 PROJECT NO. 259.00 PROJECT Langlais Addition CLIENT Langlais VIEW Southeast Corner CB Consulting & Design 359 Beech Hill Road Granville, MA 01034 Tel: 413.455.4028 A South Elevation North Elevation 1/4" = 1'-0'0'4'2'8'A 01DESIGNERCB Consulting & Design359 Beech Hill RoadGranville, MA 01034Tel: 413.455.4028CLIENTLanglais72 Lake StreetNorthampton, MA 01062REVISEDSeptember 8, 2018DATEJune 1, 2018PROJECTLanglais AdditionPROJECT NO.259.00DRAWN BYC. BouwerSHEET DESCRIPTIONSouth & North Elevations SCALECOPYRIGHT 2018 Chris Bouwer, Owner, CB Consulting and Design East Elevation West Elevation 1/4" = 1'-0'0'4'2'8'A 02DESIGNERCB Consulting & Design359 Beech Hill RoadGranville, MA 01034Tel: 413.455.4028CLIENTLanglais72 Lake StreetNorthampton, MA 01062REVISEDSeptember 8, 2018DATEJune 1, 2018PROJECTLanglais AdditionPROJECT NO.259.00DRAWN BYC. BouwerSHEET DESCRIPTIONEast & West ElevationsSCALECOPYRIGHT 2018 Chris Bouwer, Owner, CB Consulting and Design T. O. W. 100'-0" FOUNDATION NOTES1.ALL FOOTINGS SHALL BE PLACED ON UNDISTURBED SOIL HAVING A MINIMUM BEARING CAPACITY OF 3000 LBS PER SQUARE FOOT 2.NO FOOTING SHALL BE PLACED IN WATER OR ON FROZEN GROUND 3.ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 4'-0" BELOW FINISH GRADE 4.A MINIMUM OF 6" COMPACTED GRAVEL OR STONE SHALL BE PLACED UNDER ALL POURED CONCRETE SLABS 5.ALL POURED CONCRETE SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 LBS PER SQUARE INCH 6.ALL POURED CONCRETE FOUNDATIONS SHALL BE IN ACCORDANCE WITH INTERNATIONAL RESIDENTIAL CODE R401-R408 7.DO NOT BACKFILL AGAINT WALL UNTIL CONCRETE HAS REACHED ITS DESIGN STRENGTH AND WALLS ARE ADEQUATELY BRACED 8.DAMPPROOFING IS TO BE PLACED IN STRICT ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS 9.FOOTINGS PLACED ON FILL TO BE ENGINEERED BY OTHERS EXISTING CONDITIONS EXISTING CONDITIONS T. O. W. 100'-0" T. O. W. 100'-0" T. O. W. 100'-0" T. O. W. 100'-0" T. O. W. 99'-1 1/2" T. O. W. 99'-1 1/2" T. O. W. 98'-0" T. O. W. 99'-6" T. O. W. 100'-0" MAX 12"MIDPOINTMIDPOINT#4 REBAR #4 REBAR MINIMUM HORIZONTAL STEEL REINFORCEMENT FOR FOUNDATION WALL PER TABLE R404.1.2 EXISTING 8" THICK POURED CONCRETE FOUNDATION WALL 1'-4" x 0'-8" POURED CONCRETE FOUNDATION FOOTING 1/2" ANCHOR BOLT WITH NUT AND WASHER 4'-0" O. C. MINIMUM MAX 12"MIDPOINTMIDPOINT#4 REBAR #4 REBAR MINIMUM HORIZONTAL STEEL REINFORCEMENT FOR FOUNDATION WALL PER TABLE R404.1.2 CMU BLOCKS FILLED 4'-0" O. C. WITH VERTICAL #4 REBAR 8" THICK POURED CONRETE FOUNDATION WALL #4 REBAR PLACED 4'-0" MINIMUM 4" DEPTH EACH SIDE 2 MINIMUM HORIZONTAL #4 REBAR PLACED 4'-0" O. C. MINIMUM 4" DEPTH EACH SIDE 1/2" ANCHOR BOLT WITH NUT AND WASHER 4'-0" O. C. MINIMUM MAX 12"MIDPOINTMIDPOINT#4 REBAR #4 REBAR 1'-4" x 0'-8" POURED CONCRETE FOUNDATION FOOTING 8" THICK POURED CONRETE FOUNDATION WALL DAMPPROOFING APPLIED BELOW GRADE 4" FIBER REINFORCED POURED CONCRETE FLOOR SLAB UNDISTURBED SOIL UNDISTURBED SOIL UNDISTURBED SOIL 2" (R-15) RIGID iNSULATION OVER 6 MIL VAPOR BARRIER T. O. W. 98'-0" #4 REBAR PLACED 4" DEPTH EACH SIDE VOID FILLED WITH POURED CONCRETE CMU BLOCKS REMOVED BELOW FLOOR LEVEL #4 REBAR PLACED 4'-0" MINIMUM 4" DEPTH EACH SIDE 4" FIBER REINFORCED POURED CONCRETE FLOOR SLAB ELEVATION: 100'-0" T. O. W. 99'-6" T. O. W. 100'-6" T. O. W. 100'-6" 2" (R-15) RIGID INSULATION OVER 6 MIL VAPOR BARRIER 2" (R-15) RIGID INSULATION MITERED ALONG TOP EDGE PERIMETER 6" MINIMUM COMPACTED GRAVEL 4" FIBER REINFORCED POURED CONCRETE FLOOR SLAB 6" MINIMUM COMPACTED GRAVEL 2" (R-15) RIGID INSULATION MITERED ALONG TOP EDGE PERIMETER PT 2X6 OVER 1/4" SILL SEAL PT 2X6 OVER 1/4" SILL SEAL MINIMUM HORIZONTAL STEEL REINFORCEMENT FOR FOUNDATION WALL PER TABLE R404.1.2 S1A03Foundation Section S3 A03Scale: 1"=1'-0" Foundation Section S2 A03Scale: 1"=1'-0" Foundation Section S1 A03Scale: 1"=1'-0" S2A03S3 A03 CMU WALLS TO BE BROUGHT DOWN TO BELOW SLAB LEVEL AND VOID TO BE FILLED WITH POURED CONCRETE 31'-6"35'-0"11'-6"19'-6"11'-6" 43'-0" 11'-6"1/4" = 1'-0'N 0'4'2'8'NOTE: BUILDER TO VERIFY ALL DIMENSIONS & MEASUREMENTS BEFORE STARTING CONSTRUCTION A 03DESIGNERCB Consulting & Design359 Beech Hill RoadGranville, MA 01034Tel: 413.455.4028CLIENTLanglais72 Lake StreetNorthampton, MA 01062REVISEDSeptember 8, 2018DATEJune 1, 2018PROJECTLanglais AdditionPROJECT NO.259.00DRAWN BYC. BouwerSHEET DESCRIPTIONFoundation PlanSCALECOPYRIGHT 2018 Chris Bouwer, Owner, CB Consulting and Design DECK BEDROOM BATHROOM & LAUNDRY LIVING ROOM KITCHENRAMP UPSUPPLY CLOSET BATHROOM/ SHOWER DECK BREEZEWAY RAMP UPRAMP UP PT ROOM RAMP UPS4 A06 S5 A06 S6A06S7A0631'-6"11'-6"19'-6"11'-6"9'-6"10'-6"8'-0"12'-0"23'-0"25'-6"16'-6"24'-0" 40'-6"3'-0"7'-6"35'-0"3'-3"5'-3"13'-0"10'-2"3'-4"10'-0"8'-6"13'-2"3'-4"2'-4"3'-4"3'-10"2'-0"7'-6"10'-9"4'-1"3'-2"4'-9"12'-9"8'-0"25'-6"5'x5' LANDING5'x7' LANDING 13'-9"11'-0"6'-0" x 6'-8"3'-0" x 6'-8"3'-6" x 6'-8"2'-4"3'-4"3'-10"2'-0" 3'-4" 2'-1/2" 10'-2 1/2"9'-4"6'-7"10'-1"5'-4 1/2"3'-6" x 6'-8"4'-0" x 6'-8"6'-0" x 6'-8"4'-0" x 6'-8"3'-0" x 6'-8"3'-6" x 6'-8" 3'-6" x 6'-8"3'-0" x 6'-8"3'-6" x 6'-8"3'-0" x 6'-8"3'-0" x 6'-8" 3'-0" x 6'-8"3'-0" x 4'-2"3'-0" x 4'-2"3'-0" x 4'-2"3'-0" x 4'-2" 3'-0" x 4'-2"3'-0" x 4'-2"2'-6" x 3'-2"2'-6" x 3'-2"2'-6" x 3'-2"2'-6" x 3'-2"7'-6"10'-11"8'-6" 19'-0"1/4" = 1'-0'N 0'4'2'8'NOTE: BUILDER TO VERIFY ALL DIMENSIONS & MEASUREMENTS BEFORE STARTING CONSTRUCTION A 04DESIGNERCB Consulting & Design359 Beech Hill RoadGranville, MA 01034Tel: 413.455.4028CLIENTLanglais72 Lake StreetNorthampton, MA 01062REVISEDSeptember 8, 2018DATEJune 1, 2018PROJECTLanglais AdditionPROJECT NO.259.00DRAWN BYC. BouwerSHEET DESCRIPTIONFloor PlanSCALECOPYRIGHT 2018 Chris Bouwer, Owner, CB Consulting and Design DECK8'-0" x 12'-0"BEDROOM11'-6" x 18'-6" BTHRM LNDRY8'-6" x 10'-6" LIVING ROOM16'-6" x 23'-6" KITCHENRAMP UPSUPPLY CLOSET 10'-0" x 10'-6" BATHROOM/ SHOWER 9'-6" x 18'-6" EXISTING DECK BREEZEWAY 11'-6" x 15'-6"RAMP UPRAMP UP PT ROOM 18'-6" x 20'-2"RAMP UPEXISTING CONDITIONS GFCI GFCI GFCI WP GFCI WP WP WP WP LEGEND CEILING FAN W/ LIGHT CEILING FAN 12"X48" FLOURESCENT CEILING OUTLET RECESSED LIGHT PULL SWITCH LIGHT WALL LIGHT FLOOD LIGHT VANITY LIGHT TOGGLE SWITCH DIMMER SWITCH 3 WAY SWITCH 4 WAY SWITCH DUPLEX OUTLET @ 18" QUADRUPLEX OUTLET SMOKE DETECTOR EXHAUST FAN DOOR BELL DOOR BELL CHIME THERMOSTAT CABLE HOOKUP BREAKER BOX GFCI DUPLEX OUTLET WEATHER PROOF DUPLEX OUTLET GFCI WP MINI SPLIT HEAT PUMP 8' Electric Baseboard Heater MINI SPLIT WALL CASSETTE LIGHT/FAN/HEAT LAMP COMBO CEILING OUTLET FOR OVERHEAD HOIST 5'x5' LANDING 5'x7' LANDING 1/4" = 1'-0"N 0'8'4'16'NOTE: BUILDER TO VERIFY ALL DIMENSIONS & MEASUREMENTS BEFORE STARTING CONSTRUCTION E 01DESIGNERCB Consulting & Design359 Beech Hill RoadGranville, MA 01034Tel: 413.455.4028CLIENTLanglais72 Lake StreetNorthampton, MA 01062REVISEDJuly 16, 2018DATEJune 1, 2018PROJECTProject NamePROJECT NO.259.00DRAWN BYC. BouwerSHEET DESCRIPTIONElectrical PlanSCALECOPYRIGHT 2018 Chris Bouwer, Owner, CB Consulting and Design 24'-0"26'-0"1-3/4 6 2 6 2 2 64 2 4 2 4 2 2 6 4 2 4 2 4 2 2'-0" 1/2" VINYL SOFFIT BENT ALUMINUM FLASHING TO COVER FACIA 8 2 NAILING SCHEDULE LOCATION NOTES APA RATED ICBO APPROVED SHEATHING MINIMUM NOMINAL PLYWOOD THICKNESS (INCHES) MINIMUM WIDTH OF FRAMING MEMBERS (INCHES) BLOCKED PANEL EDGES REQUIRED COMMON NAIL SIZE NAIL SPACING AT PERIMETER PANEL EDGES AND DIAPHRAGM BOUNDARIES (IN O. C.) NAIL SPACING AT OTHER PANEL EDGES (IN O. C.) NAIL SPACING AT INTERMEDIATE FRAMING MEMBERS (IN O. C.) FLOOR 1 CDX OR OSB 3/4 1.5 NO 10d 6 6 12 STUD WALL 1 & 3 CDX OR OSB 7/16 1.5 YES 8d 6 6 12 ROOF 1 & 2 CDX OR OSB 5/8 1.5 NO 10d 6 6 12 NOTES: 1. NAILS SHALL NOT BREAK TH SURFACE OF THE SHEATHING 2. 7/16" THICK SHEALTHING IS AN ACCEPTABLE SUBSTITUTION, BUT MAY DEVELOP VISIBLE SAG OVER TIME. 8d NAILS MAY BE USED WITH 7/16" SHEATHING 3. STUDS @ 16" O. C. MAX EXISTING CONDITIONSFRAMING NOTESFLOOR FRAMING: 1.ALL FLOOR FRAMING SHALL BE IN ACCORDANCE WITH INTERNATIONAL RESIDENTIAL CODE R501-R507 2.ALL CONCRETE WALLS SHALL BE TOPPED WITH 1/4" x 5-1/2" FOAM SILL PLATE GASKET AND PRESSURE TREATED 2X6 SOLE PLATE BEFORE ANY FRAMING IS TO BE PLACED 3.MAIN FLOOR BEAM TO BE BUILT-IN-PLACE USING 4 PLY OF 2x8 FRAMING MEMBERS 4.9-1/2" NORDIC NI-40X CLEAR SPAN TJI SYSTEM (OR EQUIVALENT) TO BE USED FOR FLOOR FRAMING WITH 1-1/8" OSB RIMBOARD 5.3/4" T&G SHEATHING TO BE GLUED AND SCREWED IN PLACE WALL FRAMING: 1.ALL WALL FRAMING SHALL BE IN ACCORDANCE WITH INTERNATIONAL RESIDENTIAL CODE R601-R610 2.TYPICAL 2x6 WALL CONSTURUCTION WITH DOUBLE TOP PLATE AND 8'-0" WALL HEIGHT 3.HEADER SPANS PER TABLES R602.7 (1), R602.7 (2), AND R602.7 (3) ROOF FRAMING: 1.ALL ROOF FRAMING TO BE IN ACCORDANCE WITH INTERNATIONAL RESIDENTIAL CODE R801-R807 2.ENGINEERED TRUSS SYSTEM (PROVIDED BY OTHERS) TO BE USED FOR ROOF FRAMING OVER ADDITION AND GARAGE WITH A ROOF PITCH OF 4. SECURED WITH HURRICANE BRACKETS AND SHEATHING CLIPS USED BETWEEN TRUSSES 3.TYPICAL 2x8 ROOF CONSTRUCTION WITH 2x6 CEILING JOISTS OVER BREEZEWAY WITH A ROOF PITCH OF 2 4.TYPICAL 2x6 ROOF CONTRUCTION WITH 2x4 CEILING JOISTS OVER ENTRYWAY WITH A ROOF PITCH OF 2 5.TYPICAL 2X6 ROOF CONSTRUCTION OVER STORAGE AREA WITH A ROOF PITCH OF 4 6.6" OVERHANG ON ENTIRETY OF NEW ROOF SYSTEM BUILT-UP 2x4 HEADER FULL LENGTH OF WALLNAILING STRIP CEILING HEIGHT OF 7'-2" RAFTER LENGTH ROOF LENGTH STEEL ROOF RECOMMENDEDR-30 CRAFT FACED BATT INSULATION 14"x4`-0" RAFTER VENT EVERY OTHER BAY EXISTING CONDITIONS4" FIBER REINFORCED POURED CONCRETE FLOOR SLAB Breezeway Roof Section S7 A05Scale: 3/4"=1'-0" S4 A06 S5 A06 S7A05S6A06S6A06S7A06S4 A06 Roof Framing Plan Floor Framing Plan 28'-2 1/2" 15'-3 3/16" RAKE LENGTH 1'-11 1/4"1 1/2" 9'-4 1/16"36'-7/8"35'-8 3/8" 1'-11 1/4" 1 1/2" 19'-4"18'-0"2'-0"2'-3/4"6"6"2'-0"19'-6 7/8"31'-6"35'-0"43'-0" 11'-6"19'-6"15'-6"11'-6" 9'-8 5/16"9'-11 1/8"1'-8 1/16" RAKE LENGTH 24'-0"7'-6"1/4" = 1'-0'N NOTE: BUILDER TO VERIFY ALL DIMENSIONS & MEASUREMENTS BEFORE STARTING CONSTRUCTION 0'4'2'8'A 05DESIGNERCB Consulting & Design359 Beech Hill RoadGranville, MA 01034Tel: 413.455.4028CLIENTLanglais72 Lake StreetNorthampton, MA 01062REVISEDSeptember 8, 2018DATEJune 1, 2018PROJECTLanglais AdditionPROJECT NO.259.00DRAWN BYC. BouwerSHEET DESCRIPTIONFraming PlansSCALECOPYRIGHT 2018 Chris Bouwer, Owner, CB Consulting and Design HEADER JAMB SILL 62 62 2 6 2 6 2 4 8" CONCRETE FOUNDATION-REINFORCED WITH #4 REBAR HORIZONTALLY AT TOP AND MIDDLE OF WALL PT 2x6 SOLE PLATE 1/2" DIA. X 10" ANCHOR BOLTS @ 4`-0" O.C. 6 MIL. VAPOR BARRIER OVER 6" MINIMUM CRUSHED GRAVEL 2" (R-15) RIGID INSULATION 4" FIBER REINFORCED POURED CONCRETE FLOOR SLAB FINISH FLOOR UNDERLAYMENT T&G HARDWOOD OR LAMINATE FLOORING RECOMMENDED 2x4 NAILNG BLOCK FOR SOFFIT 1/2" PERFORATED VINYL SOFFIT VENT ENGINEERED ROOF TRUSSES AT 24" O.C. 5/8" OSB SHEATHING WITH PLYWOOD CLIPS 15# FELT PAPER FASTENED WITH DISCS & STAPLES 30 YEAR ARCHITECTURAL SHINGLES ROLLED RIDGE VENT WITH ASPHALT RIDGE CAP 3" PAINTED ALUMINUM DRIP EDGE 14" CELLULOSE INSULATION INSULATED HEADER WITH 1 1/2" RIGID INSUL. SAND- WICHED WITH 1/2" PLY. 1/2" GYPSUM WALL BOARD OVER 6 MIL. VAPOR BARRIER FASCIA AND RAKE WRAPPED IN ALUMINUM TYPICAL WALL CONSTRUCTION:2x6 STUDS AT 16" O.C. 7/16" OSB SHEATHING AIR BARRIER HOUSE WRAPVINYL SIDING WITH 4 INCH EXPOSURE R-21 CRAFT FACED BATT INSULATION DAMPROOFING APPLIED BELOW GRADE 3/4" CRUSHED STONE: PROTECTED WITH FILTER FABRIC 4" DIA. PERFORATED PVC/RIGID FOUNDATION DRAIN PIPE. SLOPETO DRAIN, HOLES DOWN. VERTICAL CLEAN-OUTS TO GRADE & CAPPED AT CORNERS. 1/2" PLYWOOD WITH 2x4 BLOCKING TO TO HIDE SOFFIT EDGE CONTAIN CELLULOSE 5 22"x4`-0" RAFTER VENTS EVERY OTHER BAY VINYL DOUBLE HUNG WITH WINDOWS TO BE NEW CONSTRUCTION J-CHANNEL FLANGE 1/2" GYPSUM WALL BOARD TYPICAL ROOF CONSTRUCTION: ALL WINDOW AND DOOR NAILING FLANGES TO BE COVERED WITH 6" SEALING TAPE WITH HURRICAN CLIPS AT WALL TYPICAL FLOOR CONSTRUCTION OVER 1/4" SILL SEAL 8"x16" CONCRETE FOOTING 6226 2 662 6 6 2 2 62 2 6 2 6 2 6 2 4 62 2" (R-15) RIGID INSULATION APPLIED TO INTERIOR OF WALL MITERED AT TOP EDGE OF PERIMETER Building Section S4 A06 D01 A06 Building Section S6 A06 Typical Wall SectionScale: 1 1/2"=1'-0" Building Section S5 A06 6'-8 3/4"RIDGE BOARD NOTCHED TO RECIEVE TRUSS AND SHEATHING TRIMMED FLUSH TRUSSES IN WAY OF BREEZEWAY TO BE TRIMMED BACK 7/16" TO ACCOMODATE PLYWOOD FOR CORNER RETURNS (SEE REFERENCE PICTURE 1) 2x4 BLOCKING TO SUPPORT 2x6 CEILING JOIST :: Roof Connection DetailScale: 1 1/2"=1'-0" D01 A06Reference Picture 1Northeastern Perspective 8'-0"5 6'-10 1/2"9'-0"6'-11 1/4"8'-0"6'-8"6'-8"6'-10 1/2"1/4" = 1'-0'0'4'2'8'NOTE: BUILDER TO VERIFY ALL DIMENSIONS & MEASUREMENTS BEFORE STARTING CONSTRUCTION A 06DESIGNERCB Consulting & Design359 Beech Hill RoadGranville, MA 01034Tel: 413.455.4028CLIENTLanglais72 Lake StreetNorthampton, MA 01062REVISEDSeptember 8, 2018DATEJune 1, 2018PROJECTLanglais AdditionPROJECT NO.259.00DRAWN BYC. BouwerSHEET DESCRIPTIONBuilding SectionsSCALECOPYRIGHT 2018 Chris Bouwer, Owner, CB Consulting and Design