Loading...
17105-Field Report 03 (Dunkin) AHARONIAN & ASSOCIATES INC. - ARCHITECTS 310 George Washington Highway - Suite 100 - Smithfield, Rhode Island 02917 T 401-232-5010 F 401-232-5080 Page 1 of 2 FIELD REPORT #3 REPORT DATE: 12/19/18 DUNKIN' DONUTS BUILDING Northampton, MA Aharonian Job No. 17105.01 DATE TIME WEATHER TEMPERATURE 12/14/18 10:00 AM Cloudy +/- 40 degrees F PRESENT AT SITE: Jackie Brousseau & Joshua Nolle Aharonian Associates, Inc Various Subcontractors & Employees of Homeland Builders, Inc To the best of our knowledge, the Work being performed is in accordance with the Contract Documents, unless noted otherwise, and is progressing as described below. WORK IN PROGRESS: 1) Rough framing 100% complete. 2) Interior substrate installation100% complete. 3) Rough plumbing 100% complete. 4) Ductwork installation 95% complete. Exhaust fan ductwork & hoods not yet installed. 5) Exterior finish work 95% complete. 6) Site work 80% complete – sign installation in progress. Pavement topcoat to be completed in the Spring. 7) Final equipment connections to electrical/plumbing in progress. OBSERVATIONS / ACTION REQUIRED: 8) The Drive-Thru canopy posts & caps were corrected since the previous visit and is in compliance with the Construction Documents. 9) The shear walls were corrected at the Vestibule since the previous visit and is in compliance with the Construction Documents. Per SKA-3, 1/2” plywood was added and is in compliance with the Construction Documents. 10) Directional sign placement locations deviate from sheet A0.2 - this modification is acceptable. 11) Fire extinguishers were not yet installed - GC to install per Construction Documents & Fire Marshal direction. 12) Glazing at the vestibule storefront system adjacent to door #100 & door #101 are not yet installed - GC to install per Drawings SKA-3. 13) Emergency Light remote heads at all exterior doors have not yet been installed - GC to install per Construction Documents. 14) Exhaust hoods have not yet been installed - GC to install per Construction Documents. 15) (1) Wall sconce light fixture missing from Drive-Thru side of building – GC to install wall sconce light fixture & connect to elect circuit as required. Aharonian & Associates Inc. 310 George Washington Highway, Suite 100, Smithfield, RI 02917 Dunkin' Donuts, Northampton MA Field Report #3 Page 2 of 2 16) EF-2 remained in its existing location within 10'-0” of the roof edge – As discussed, GC shall install guardrail on top of the parapet at 42” minimum from roof to top of guard rail. This is an acceptable deviation from the plans. 17) 90% of all metal coping missing – GC to install remainder of coping per Construction Documents. 18) Downspouts missing from both pre-fab canopies at the Vestibule. The underground drainage was installed per previous field report. GC to install downspouts & connect to underground drainage. 19) Scupper boxes and downspouts not painted correctly – GC to paint scupper boxes and downspouts per Construction Documents. REPORT BY: Jackie Brousseau Project Manager CC: Emanuel Sardinha – Owner Cliff Medeiros – Construction Manager