ComCheck-17105 signedCOMcheck Software Version 4.1.0.0 Envelope Compliance Certificate Project Title: 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency Project Type:New Construction Vertical Glazing / Wall Area:15% Location:Northampton, Massachusetts Climate Zone:5a Construction Site: 55 Damon Rd Northampton, MA 01060 Owner/Agent: Emanuel Sardinha 625 East Main Street Westfield, MA 01085 (413) 246-9676 vfcdonuts@aol.com Designer/Contractor: Jackie Brousseau Aharonian & Associates, Inc. - Architects 310 George Washington Hwy Suite 100 Smithfield, RI 02917 401-232-5010 jbrousseau@arch-eng.com Project Information Energy Code: Dunkin' Donuts Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Building Area Floor Area 1-Dining: Cafeteria/Fast Food : Nonresidential 2550 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1: Insulation Entirely Above Deck, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] 2550 ---30.0 0.032 0.032 Floor 1: Slab-On-Grade:Unheated, Vertical 3 ft., [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (c) 218 ---10.0 0.510 0.540 NORTH Exterior Wall 2: Wood-Framed, 16" o.c., [Bldg. Use 1 - Dining: Cafeteria/Fast Food] 553 21.0 0.0 0.062 0.064 F2: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PPG Glass, SHGC 0.32, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 9 ------0.370 0.380 F5: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PPG Glass, SHGC 0.32, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 112 ------0.370 0.380 F3: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PPG Glass, SHGC 0.32, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 40 ------0.370 0.380 Door 5: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID na, SHGC 0.25, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 42 ------0.690 0.770 EAST Exterior Wall 3: Wood-Framed, 16" o.c., [Bldg. Use 1 - Dining: Cafeteria/Fast Food] 1111 21.0 0.0 0.062 0.064 F6: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PPG Glass, SHGC 0.32, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 7 ------0.370 0.380 Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 241 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter F7 (x2): Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PPG Glass, SHGC 0.32, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 32 ------0.370 0.380 SOUTH Exterior Wall 4: Wood-Framed, 16" o.c., [Bldg. Use 1 - Dining: Cafeteria/Fast Food] 553 21.0 0.0 0.062 0.064 Door 4: Insulated Metal, Swinging, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] 27 ------0.500 0.370 WEST Exterior Wall 1: Wood-Framed, 16" o.c., [Bldg. Use 1 - Dining: Cafeteria/Fast Food] 1111 21.0 0.0 0.062 0.064 F4 (x2): Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PPG Glass, SHGC 0.32, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 150 ------0.370 0.380 F2: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PPG Glass, SHGC 0.32, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 9 ------0.370 0.380 Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID na, SHGC 0.25, [Bldg. Use 1 - Dining: Cafeteria/Fast Food] (b) 91 ------0.690 0.770 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c) Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 2% better than code Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 242 ofPage Jackie Brousseau - Project Manager 7/19/18 COMcheck Software Version 4.1.0.0 Interior Lighting Compliance Certificate Project Title: 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency Project Type:New Construction Construction Site: 55 Damon Rd Northampton, MA 01060 Owner/Agent: Emanuel Sardinha 625 East Main Street Westfield, MA 01085 (413) 246-9676 vfcdonuts@aol.com Designer/Contractor: Jackie Brousseau Aharonian & Associates, Inc. - Architects 310 George Washington Hwy Suite 100 Smithfield, RI 02917 401-232-5010 jbrousseau@arch-eng.com Project Information Energy Code: Dunkin' Donuts Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Common Space Types:Dining Area - Cafeteria/Fast Food 886 0.59 523 2-Common Space Types:Food Preparation 733 1.09 799 3-Common Space Types:Restrooms 121 0.88 106 4-Common Space Types:Office - Enclosed 35 1.00 35 5-Common Space Types:Storage >=50 - <=1000 sq.ft.600 0.57 342 1805Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Common Space Types:Dining Area - Cafeteria/Fast Food LED 1: LED-4: 2x2 FOH: LED Panel 33W:1 16 32 512 Track lighting 1: C: Wattage based on 6 feet of track 0 0 180 180 Incandescent 1: P4: Pendant: Incandescent 60W:1 3 60 180 2-Common Space Types:Food Preparation LED 3: LED-7: 2x2 BOH: LED Panel 36W:1 5 32 160 LED 6: LED-1: Downlight: LED PAR 11W:1 7 11 77 LED 7: LED-6: 2x4 BOH: LED Other Fixture Unit 50W:1 4 49 196 3-Common Space Types:Restrooms LED 1: LED-4: 2x2 FOH: LED Panel 33W:1 2 32 64 4-Common Space Types:Office - Enclosed LED 3: LED-7: 2x2 BOH: LED Panel 36W:1 1 32 32 5-Common Space Types:Storage >=50 - <=1000 sq.ft. LED 3: LED-7: 2x2 BOH: LED Panel 36W:1 2 32 64 Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 243 ofPage E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures LED 7: LED-6: 2x4 BOH: LED Other Fixture Unit 50W:1 5 49 245 LED 9: Walk-in: Other:1 3 30 90 1800Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 0.3% better than code Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 244 ofPage Jackie Brousseau - Project Manager 7/19/18 COMcheck Software Version 4.1.0.0 Exterior Lighting Compliance Certificate Project Title: 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency Project Type:New Construction Construction Site: 55 Damon Rd Northampton, MA 01060 Owner/Agent: Emanuel Sardinha 625 East Main Street Westfield, MA 01085 (413) 246-9676 vfcdonuts@aol.com Designer/Contractor: Jackie Brousseau Aharonian & Associates, Inc. - Architects 310 George Washington Hwy Suite 100 Smithfield, RI 02917 401-232-5010 jbrousseau@arch-eng.com Project Information Energy Code: Dunkin' Donuts 4 (High activity metropolitan commercial district)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Other door (not main entry)4 ft of door 20 Yes 80 Drive-up windows/doors 1 windows 400 No 400 Main entry 3 ft of door 30 Yes 90 Main entry 3 ft of door 30 Yes 90 Illuminated area of facade wall or surface 3649 ft2 0.2 No 730 Parking area 80459 ft2 0.13 Yes 10460 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 10720 11850 1300 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Other door (not main entry) (4 ft of door width): Tradable Wattage LED 4: G: Wall Pack: LED Linear 10W:1 1 10 10 Drive-up windows/doors (1 windows or doors): Non-tradable Wattage LED 2: LED-2: Canopy Lights: LED PAR 20W:1 3 20 60 Main entry (3 ft of door width): Tradable Wattage LED 2: LED-2: Canopy Lights: LED PAR 20W:1 2 20 40 LED 2: LED-2: Canopy Lights: LED PAR 20W:1 2 20 40 Illuminated area of facade wall or surface (3649 ft2): Non-tradable Wattage LED 5: WSCX-2: Signlite: LED Other Fixture Unit 50W:1 11 50 550 LED 6: WSC-2: Wall Sconce: LED Other Fixture Unit 25W:1 15 25 375 Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 245 ofPage E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Parking area (80459 ft2): Tradable Wattage LED 7: VIF: See Site Plan: LED Roadway-Parking Unit 54W:1 11 55 605 LED 8: VIF: See Site Plan: LED Roadway-Parking Unit 54W:1 5 55 275 970Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 92% better than code Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 246 ofPage Jackie Brousseau - Project Manager 7/19/18 COMcheck Software Version 4.1.0.0 Mechanical Compliance Certificate Project Title: 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency Project Type:New Construction Location:Northampton, Massachusetts Climate Zone:5a Construction Site: 55 Damon Rd Northampton, MA 01060 Owner/Agent: Emanuel Sardinha 625 East Main Street Westfield, MA 01085 (413) 246-9676 vfcdonuts@aol.com Designer/Contractor: Jackie Brousseau Aharonian & Associates, Inc. - Architects 310 George Washington Hwy Suite 100 Smithfield, RI 02917 401-232-5010 jbrousseau@arch-eng.com Project Information Energy Code: Dunkin' Donuts Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Heating: 1 each - Central Furnace, Gas, Capacity = 73 kBtu/h Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 73 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 12.00 EER, Required Efficiency: 11.00 EER + 12.6 IEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 2400 CFM, 1.7 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System 1 (6) (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 73 kBtu/h Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 73 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 12.00 EER, Required Efficiency: 11.00 EER + 12.6 IEER Fan System: FAN SYSTEM 1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 2400 CFM, 1.7 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System 2 (6) (Single Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 98 kBtu/h Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 89 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 12.00 EER, Required Efficiency: 11.00 EER + 12.6 IEER Fan System: FAN SYSTEM 2 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Constant Volume, 3000 CFM, 2.4 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System 3 (7.5) (Single Zone): Gas Instantaneous Water Heater, Capacity: 9 gallons, Input Rating: 75 kBtu/h Proposed Efficiency: 0.67 EF, Required Efficiency: 0.60 EF 1 Water Heater 1: Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 247 ofPage Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 248 ofPage Jackie Brousseau - Project Manager 7/19/18 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.0.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 780 CMR Massachusetts State Building Code, 9th Edition, Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Completed COMcheck Envelope certificate and Plan Review Checklist will be submitted with application. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Completed COMcheck Mechanical certificate and Plan Review Checklist will be submitted with application. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR3]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Completed COMcheck Mechanical certificate and Plan Review Checklist will be submitted with application. Complies Does Not Not Observable Not Applicable Requirement will be met. C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Completed COMcheck Inteiror Lighting certificate and Plan Review Checklist will be submitted with application. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 249 ofPage Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Completed COMcheck Exteiror Lighting certificate and Plan Review Checklist will be submitted with application. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: N/A C402.4.2 [PR14]1 In enclosed spaces > 2,500 ft2 directly under a roof with ceiling heights >15 ft. and used as an office, lobby, atrium, concourse, corridor, storage, gymnasium/exercise center, convention center, automotive service, manufacturing, non- refrigerated warehouse, retail store, distribution/sorting area, transportation, or workshop, the following requirements apply: (a) the daylight zone under skylights is >= half the floor area; (b) the skylight area to daylight zone is >= 3 percent with a skylight VT >= 0.40; or a minimum skylight effective aperture >= 1 percent. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: M1.1 for requirements / Design- Build 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2410 ofPage Section # & Req.ID Plan Review Complies?Comments/Assumptions C402.3 [PR17]3 Rooftop Solar Readiness: 1) Construction documents indicate the solar ready zone where applicable, 2) the total solar-ready zone area consists of an area >= 1,600 square feet, or 50% of the roof area that is either flat or oriented between 110 degrees and 270 degrees of true north, exclusive of mandatory access or set back areas as required by 527 CMR: Board of Fire Prevention Regulations, 3) Solar-ready zones consist of an area free from obstructions, 4) the structural design loads for roof dead load and roof live load are indicated on the construction documents, 5) documents indicate pathways for routing of conduit or plumbing from the solar-ready zone to the electrical service panel or service hot water system, 6) main electrical service panel has a reserved space to allow installation of a dual pole circuit breaker for future solar electric installation and is labelled “For Future Solar Electric.” Complies Does Not Not Observable Not Applicable Exception: Assembly Group A-2 and A-3, and High Hazard Group H buildings. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2411 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.2.5 [FO3]2 Slab edge insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Envelope Assemblies table for values. C403.2.4. 5, C403.2.4. 6 [FO9]3 Snow/ice melting system sensors for future connection to controls. Freeze protection systems have automatic controls installed. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2412 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable Exception: Default values are used. C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 2.1 [FR19]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.2, C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2413 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2414 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2415 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.2.6 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.5, C403.2.4. 3 [ME58]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Exception: Gravity dampers acceptable in buildings 3 stories. C403.2.13 [ME71]2 Unenclosed spaces that are heated use only radiant heat. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.3 [ME55]2 HVAC equipment efficiency verified.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.2.4. 7 [ME113]2 Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 7 [ME113]2 Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 7 [ME113]2 Fault detection and diagnostics installed with air-cooled unitary DX units having economizers. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.6. 1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.6. 2 [ME115]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.7 [ME57]1 Exhaust air energy recovery on systems meeting Table C403.2.7(1) and C403.2.7(2). Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.8 [ME116]3 Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2416 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.2.9 [ME60]2 HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.9 [ME10]2 Ducts and plenums sealed based on static pressure and location. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.9. 1.3 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.9. 1.3 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.9. 1.3 [ME11]3 Ductwork operating >3 in. water column requires air leakage testing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.3 [ME62]1 Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high-limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.3 [ME62]1 Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high-limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.3 [ME62]1 Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high-limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.4.4. 6 [ME110]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Mechanical Systems list for values. C403.4.4. 6 [ME110]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Mechanical Systems list for values. C403.4.4. 6 [ME110]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. See the Mechanical Systems list for values. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2417 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C408.2.2. 1 [ME53]3 Air outlets and zone terminal devices have means for air balancing. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2418 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1, C405.2.2. 3 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.5 [EL25]null Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time-of-day, or reduce connected lighting > 30%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2419 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.2.1 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.2.3 [IN6]1 Above-grade wall insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.5 [IN8]2 Floor insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.2.2 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2420 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. C303.3, C408.2.5. 3 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C402.5.3 [FI51]3 Where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms are sealed and insulated. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo doors. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C402.5.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C403.2.2 [FI27]3 HVAC systems and equipment capacity does not exceed calculated loads. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1.2 [FI38]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 1.3 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2421 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C403.2.4. 2 [FI39]3 Each zone equipped with setback controls using automatic time clock or programmable control system. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.1, C403.2.4. 2.2 [FI40]3 Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2- hour occupant override, 10-hour backup Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.3 [FI11]3 Heat traps installed on supply and discharge piping of non-circulating systems. Complies Does Not Not Observable Not Applicable Requirement will be met. C404.4 [FI25]2 All piping insulated in accordance with section details and Table C403.2.10. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C405.5.1 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. C408.2.1 [FI28]1 Commissioning plan developed by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.3. 1 [FI31]1 HVAC equipment has been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.3. 2 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2422 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C408.2.3. 3 [FI32]1 Economizers have been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.4 [FI29]1 Preliminary commissioning report completed and certified by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 3 [FI43]1 An air and/or hydronic system balancing report is provided for HVAC systems. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.2.5. 4 [FI30]1 Final commissioning report due to building owner within 90 days of receipt of certificate of occupancy. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2423 ofPage Project Title: Data filename: Dunkin' Donuts S:\Arch Drawings\DUNKIN' DONUTS\17105 DD Northampton MA\01 Code Research\ComCheck\ComCheck-17105 LIGHTING.cck 07/19/18Report date: 2424 ofPage