36-014 47 Forest Glen Smoke-COSD Smoke Detector SD Smoke Detector SD Smoke Detector CO/SD CO/Smoke Detector HD Heat Detector HD Heat Detector 1097 SQ FT LIVING AREA GARAGE OFFICE KITCHEN LIVING BEDROOM BEDROOMBEDROOM TOP OF STAIRS TO BASEMENT 47 FOREST GLEN DR. FLOOR PLAN FOR CO & SMOKES Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com1 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERRevision #:0PROJECT PLANPROJECT NOTES:PROJECT NOTES:    THIS PLAN SET, COMBINED WITH THE BUILDING CONTRACT, PROVIDES BUILDING DETAILS FOR THE RENOVATION PROJECT.  THE LEAD CARPENTER SHALL VERIFY THAT SITE CONDITIONS, AND DIMENSIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING AND LOCAL CODES.   WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE SALE PERSON/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CARPENTER OR SUB-CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). ALL TRADES SHALL MAINTAIN A CLEAN WORK SITE AT THE END OF EACH WORK DAY.   PLEASE SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. OWNER: PROJECT ADDRESS: , BLDG PERMIT: DESIGNER:_________________ PRESENTATIONINDEX OF DRAWINGS TITLE SHEET PROJECT SUMMARY 1 EXISTING CONDTIONS 2 MAIN FLOOR PLAN 3 KITCHEN PLAN & ELEVATIONS 4 ELECTRICAL PLAN 5 FRONT/REAR ELEVATIONS 6 INTERIOR ELEVATIONS 7 DOOR & WINDOW SCHEDULE 8 FOR ILLUSTRATION ONLY. NO SCALEThis plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI. Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com2 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERRevision #:0FLOOR PLAN 1/4"=1' OVERVIEW RENDERING FOR ILLUSTRATION ONLY NO SCALEThis plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI.EXISTINGCONDTIONSFLOOR PLAN NOTES: FLOOR PLAN NOTES: 1. ALL EXTERIOR DIMENSIONS ARE TO THE MAIN EXTERIOR LAYER.  DIMENSIONS TO OPENINGS ARE TO THE FRAMING, ROUGH OPENING.  INTERIOR DIMENSIONS ARE TO THE FINISHED WALL. 2.CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS).   GENERAL NOTES:GENERAL NOTES: Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com3 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERRevision #:0This plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI.FLOOR PLAN 1/4"=1' FINISH SCHEDULES HERE MAIN FLOOR PLANFLOOR PLAN NOTES: FLOOR PLAN NOTES: 1. ALL EXTERIOR DIMENSIONS ARE TO THE MAIN EXTERIOR LAYER.  DIMENSIONS TO OPENINGS ARE TO THE FRAMING, ROUGH OPENING.  INTERIOR DIMENSIONS ARE TO THE FINISHED WALL. 2.LEAD CARPENTER SHALL VERIFY ALL DIMENSIONS AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS).   GENERAL NOTES:GENERAL NOTES: THE LEAD CARPENTER SHALL FULLY COMPLY WITH THE 2009 IRC AND ALL ADDITIONAL STATE AND LOCAL CODE REQUIREMENTS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE GENERAL CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS) AND CONDITIONS ON THE JOB AND MUST NOTIFY THIS OFFICE OF ANY VARIATIONS FROM THESE DRAWINGS. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND PROPER FUNCTION OF PLUMBING, HVAC AND ELECTRICAL SYSTEMS. THE LEAD CARPENTER OR SUBCONTRACTOR SHALL NOTIFY THE OFFICE WITH ANY PLAN CHANGES REQUIRED FOR DESIGN AND FUNCTION OF PLUMBING, HVAC AND ELECTRICAL SYSTEMS. DESIGN CRITERIA: 2009 IRC AND IBC ALONG WITH STATE AND LOCAL AMENDMENTS ROOF: SNOW LOAD DETERMINED BY AMENDED I.R.C. FLOOR: 40 PSF LL. SOIL: *2,000 PSF ALLOWABLE (ASSUMED). FROST DEPTH: 4'-0" THIS STRUCTURE SHALL BE ADEQUATELY BRACED FOR WIND LOADS UNTIL THE ROOF, FLOOR AND WALLS HAVE BEEN PERMANENTLY FRAMED TOGETHER AND SHEATHED. INTERIOR FINISH NOTES: RENDERINGS ARE NOT TO SCALE; ALL RENDERINGS ARE FOR ARTISTIC DEPICTION ONLY. PLAN UPDATES MAY NOT BE REFLECTED IN RENDERINGS. RENDERINGS SHALL NOT BE USED FOR CONSTRUCTION. - SEE FINISH PLANS & SCHEDULE FOR SPEC'S EXTERIOR FINISH NOTES: RENDERINGS ARE NOT TO SCALE; ALL RENDERINGS ARE FOR ARTISTIC DEPICTION ONLY. PLAN UPDATES MAY NOT BE REFLECTED IN RENDERINGS. RENDERINGS SHALL NOT BE USED FOR CONSTRUCTION. - SEE FINISH AND PLANS & SCHEDULE FOR SPEC'S . Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com4 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERWALL CABINET ELEVATIONS HERE WALL CABINET ELEVATIONS HERE Revision #:0WALL CABINET ELEVATIONS HERECABINET SCHEDULES HERE This plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI.WALL CABINET ELEVATIONS HERE CABINET/VANITY NOTES:CABINET/VANITY NOTES: 1.ALL CABINETS __WOOD SPECIES HERE_____WOOD SPECIES HERE___; CONFIRM LACQUER, NAT , GLAZE FINISH WITH HOME OWNER PRIOR TO ORDERING. 2.SOLID WOOD ____DOOR STYLE HERE_______DOOR STYLE HERE___ DOORS. SPECIAL BEADING OR TRIM TO BE BEAD SPECIFICATIONBEAD SPECIFICATION IF APPIF APP CONFIRM DOOR & DRAWER STYLES WITH HOME OWNER PRIOR TO ORDERING. 3.SPECIAL HARDWARE SUCH AS REV-A-SHELF OR OTHER MANUFACTURED HARDWARE WILL BE PROVIDED BY OWNER OR VHI?OWNER OR VHI? .. 4.CABINET MOLDING TO BE INSTALLED ON SITE; MATCH ISLAND CABINET COLOR IF APPLIES; CABINET MOLDING SPEC IS__MOLDING PROFILE HERE____MOLDING PROFILE HERE__ CONFIRM PROFILE AND DIMENSION WITH HOME OWNER. 5. SEE APPLIANCE SPECIFICATIONS FOR DIMENSIONS, POWER, AND GAS DEMANDS. 6.INSTALL HOOD AND ALL APPLIANCES PER MANUFACTURER SPECIFICATIONS. 7.REFER TO APPLIANCE SPECIFICATIONS FOR AMP/ VOLTAGE REQUIREMENTS 8.REFER TO HOOD SPECS FOR DUCT SIZE UNLESS OTHERWISE SPEC. 9.CONFIRM FINAL MATERIALS FOR BACKSPLASH AND COUNTERTOP WITH HOME OWNER PRIOR TO ORDERING. 10.CABINET GLASS: ____GLASS SPEC HERE IF APPLIES_________ 11.ALL DOORS AND DRAWERS TO BE SOFT CLOSE, UNLESS SPEC'D 12.LED LIGHTS TO BE LOCATED - __LOCATION FOR LED LIGHTING__ 13.COUNTER FABRICATION: CONFIRM ALL FIXTURE MEASUREMENTS AND CENTERLINES, SEE COUNTERTOP PLAN FOR DETAILS KITCHEN DETAILS & ELEVATIONS Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com5 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERRevision #:0This plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI.ELECTRICAL, DATA, &ELECTRICAL, DATA, & AUDIO NOTES:AUDIO NOTES: HOME OWNER SHALL DO A WALK-THRU WITH RELEVANT INSTALLERS TO VERIFY THE EXACT LOCATION FOR OUTLETS, LIGHTS, SWITCHES, CABLE, DATA, PHONE, AUDIO, VACUUM, ETC. ELECTRICAL NOTES:ELECTRICAL NOTES: 1.ALL APPLIANCES & UTILITIES TO HAVE DEDICATED CIRCUITS PER CURRENT ELECTRIC CODE STANDARDS AT TIME OF INSTALLATION. SEE MFG'S SPECS FOR OTHER REQUIREMENTS 2.ELECTRICAL RECEPTACLES IN BATHROOMS, KITCHENS AND GARAGES SHALL BE G.F.C.I. PER NATIONAL ELECTRICAL CODE REQUIREMENTS. 3.SMOKE AND CO DETECTORS WILL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA REGULATIONS 4.CIRCUITS SHALL BE VERIFIED WITH HOME OWNER PRIOR TO WIRE INSTALLATION. 5.FINAL SWITCHES FOR TIMERS AND DIMMERS SHALL BE VERIFIED WITH HOME OWNER. 6.ALL SURFACE MOUNTED FIXTURES TO BE SELECTED AND PURCHASED BY HOME OWNERHOME OWNER.. 7.ALL DECORATIVE FIXTURES TO BE SELECTED AND PURCHASED BY HOME OWNERHOME OWNER.. 8.BATH VENTILATION TO BE BATH VENT SPEC HEREBATH VENT SPEC HERE, AND IS PURCHASED BY VHI OR HOME OWNERVHI OR HOME OWNER 9.UNO - ALL SWITCHES TO BE 48" O/C ASF. OUTLETS TO BE 15" O/C ASF. OUTLETS OVER COUNTERTOPS TO BE 3" ABOVE COUNTER FROM BOTTOM. (ASF = ABOVE SUBFLOOR) DATA / CABLE: DATA / CABLE: 1. LOCATION OF PHONE/CABLE/ETHERNET CABLES TO BE CONFIRMED WITH HOWE OWNER PRIOR TO INSTALLATION IF APPLICABLE.ELECTRICAL, DATA,& AUDIO PLANELECTRICAL PLAN - MAIN FLOOR 1/4"=1' 1 0 1 2 3 Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com6 ,DRAWN BY: S.G.GENERAL SITE NOTES: MAP/BLOCK/LOT: ACREAGE: FRONTAGE: SOIL CONDITIONS:DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERRevision #:0This plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI.SITE PLAN 1"=10'SITE PLAN Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com7 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERRevision #:0EXTERIORELEVATIONSThis plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI. Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com8 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERRevision #:0This plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI. FIREPLACE WALL ELEVATION 1/2"=1' CLOSET 1 ELEVATION 1/2"=1' OFFICE WALL ELEVATION 1/2"=1' CLOSET 2 ELEVATION 1/2"=1' CLOSET 3 ELEVATION 1/2"=1' OFFICE PERSPECTIVE FOR ILLUSTRATION ONLY NO SCALE MASTER BEDROOM PERSPECTIVE FOR ILLUSTRATION ONLY NO SCALE FIREPLACE PERSPECTIVE FOR ILLUSTRATION ONLY NO SCALE MASTER CLOSET PERSPECTIVE FOR ILLUSTRATION ONLY NO SCALE GG II FF INTERIORELEVATIONSHH CC Valley Home Improvement, Inc.340 Riverside Drive, PO Box 60627, Northampton, MA 01062Office Phone 413.584.7522 Fax 413.585.0820Find us on the web at : www.ValleyHomeImprovement.com9 ,DRAWN BY: S.G.DATE:8/28/2018SCALE: SEE VIEWSHEET NUMBERDOOR SCHEDULE Revision #:0DOOR & WINDOW SCHEDULESThis plan is the proprietary work product of Valley Home Improvement, Inc.(VHI). It is delivered for the limited and exclusive purpose of supporting the contract bid of VHI, and customer agrees that the elements of this plan shall not be republished or presented in anyform for the purpose of enabling or supporting the work of competing project contractors without the permission of, and compensation paid to, VHI.DOOR & WINDOW NOTES:    1. NEW WINDOWS EXT. FINISH:_____________________ ____ 2.NEW WINDOW INT. FINISH:______________________________ 3.NEW WINDOW HARDWARE TYP &FIN:____________________ 4.NEW WINDOW INTERIOR TRIM:__________________________ DOOR / WINDOW SCHEDULE - MAIN FLOOR 3/16"=1' DOOR / WINDOW SCHEDULE - BASEMENT 3/16"=1' WINDOW ENERGY RATINGS WINDOW SCHEDULE