32A-083 46-50 Graves Ave scope 2017-06-30 (2)To: Northamton Building Department Attn. Louis Hasbrouk 48-50 Graves Ave Northampton, MA Scope of work Roof: * strip existing low pitch roofing • Replace affected 2x8 ceiling joists with 2x12 !6” OC • Replace roof deck with 5/8” or ¾” ply and re roof entire roof with high grade rubber roofing and substrate. • Rebuild the center supporting wall to accommodate 2x12 joists. • Remove and replace framing on 3rd floor front wall, from top of window to top plate, adding 2x10 headers and new king studs. • Remove and replace sheathing on front wall damaged by fire. • Remove and replace damaged portions of 3rd floor porch. • Any Code upgrades required. * wiring (to be determined after demolition) * Plumbing (to be determined after demolition) * Smoke and CO detectors Hardwired (electrician will supply marked floorplan) *Fire stops and draft stops as necessary. My insulation contractor will use “RokSul” for draftstop. My Framer will solid block necessary fire blocking. *Framing ; add headers with 6” bearing on Jack studs * Insulation: R-15 UHP in all 2x4 exterior walls R-49 KFT in 3 rd floor ceiling. R-19 and 1” foam in Rim joist bays Please let me know if I have missed anything. Thank You Sir Doug Dowd Baystate RG 413 378 2526