32A-083 46-50 Graves Ave scope 2017-06-30To:
Northamton Building Department
Attn. Louis Hasbrouk
48-50 Graves Ave Northampton, MA
Scope of work
Roof: * strip existing low pitch roofing
Replace affected 2x8 ceiling joists with 2x12 !6” OC
Replace roof deck with 5/8” or ¾” ply and re roof entire roof with high grade rubber roofing and substrate.
Rebuild the center supporting wall to accommodate 2x12 joists.
Remove and replace framing on 3rd floor front wall, from top of window to top plate, adding 2x10 headers and new king studs.
Remove and replace sheathing on front wall damaged by fire.
Remove and replace damaged portions of 3rd floor porch.
Any Code upgrades required.
* wiring (to be determined after demolition)
* Plumbing (to be determined after demolition)
* Smoke and CO detectors Hardwired (electrician will supply
marked floorplan)
*Fire stops and draft stops as necessary. My insulation
contractor will use “RokSul” for draftstop. My Framer will solid
block necessary fire blocking.
*Framing ; add headers with 6” bearing on Jack studs
* Insulation: R-15 UHP in all 2x4 exterior walls
R-49 KFT in 3 rd floor ceiling.
R-19 and 1” foam in Rim joist bays
Please let me know if I have missed anything.
Thank You Sir
Doug Dowd Baystate RG 413 378 2526