12C-130 rev truss QB1212002-STIEBEL-RKH-042913-DWGSSPECIAL INSTRUCTIONS:
*BASED ON PLANS DATED 10/05/2012; AND 4/29/13 CHANGES.
*GABLES DROPPED FOR 2X6 OUTLOOKERS.
*REVIEW OVERHANG LEVEL DETAIL.
*GAS FIREPLACE.
QUOTE # QB1212002
PAGE 1
DATE QUOTED:04/29/13
VALID UNTIL: 05/27/13
PRINTED ON: 04/29/13
24 West St.
West Hatfield, MA 01088
r.k. Miles, Inc.
(413) 247-8300
Attn:RICH BLAISE
MANUFACTURERS OF ROOF & FLOOR TRUSSES
181 GOODWIN ST
PO BOX 51027
INDIAN ORCHARD, MA 01151
Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187
Quote To:
Phone:
Job:STIEBEL RESIDENCE
CLOVERDALE EXTENSION
NORTHAMPTON, MA
Brian TetreaultQuoted By:
Requested By:RICH BLAISE
CONTRACTOR QUOTE
QTY TYPE
SPAN LUMBER
TOP BOT
OVRHG / CANT
LEFT RIGHT
PITCH
TOP BOT TRUSS IDPROFILE
ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL
50.0,10.0,0.0,10.0
STRESS INCR.
1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)
PLY
O/ABASE
SPAN
UNIT
WEIGHT
SHIPPING HEIGHT
LAYOUTBRT 04/29/13
01 8.00 0.00 02-10-15
02-00-00
2 X 4 2 X 4
JACK-CLOSED
4 02-10-15 1403-07-08
02 8.00 0.00 05-00-00
02-00-00
2 X 4 2 X 4
JACK-CLOSED
5 05-00-00 2105-00-03
CJ1 5.66 0.00 06-11-06
02-09-15
2 X 4 2 X 4
DIAGONAL HIP
2 06-11-06 4405-01-06
G1
1
8.00 0.00 16-09-00 2 X 4 2 X 6
HIP TRUSS
2 Ply 16-09-00 8804-07-00
G2
1
8.00 0.00 16-09-00 2 X 4 2 X 6
HIP TRUSS
2 Ply 16-09-00 10805-11-00
M1 4.00 0.00 08-06-00
02-00-00
2 X 4 2 X 4
MONOPITCH
3 08-06-00 3303-10-00
M1A 4.00 0.00 07-00-00
02-00-00
2 X 4 2 X 4
MONOPITCH
11 07-00-00 2803-04-00
M1B 4.00 0.00 07-00-00
02-00-00
2 X 4 2 X 4
MONOPITCH 5 07-00-00 2903-10-00
M1DGE 4.00 0.00 08-06-00 2 X 4 2 X 4
Monopitch
1 08-06-00 3103-04-03
M2 4.00 0.00 06-00-00
02-00-00
2 X 4 2 X 4
MONOPITCH
8 06-00-00 2003-00-00
M2DGE 4.00 0.00 06-00-00
02-00-00
2 X 4 2 X 4
GABLE
2 06-00-00 2102-11-11
T1 4.00 0.00 07-10-00
02-00-00 02-00-00
2 X 4 2 X 4
SPECIAL
11 07-10-00 3002-09-11
T2 6.00 0.00 34-00-00
02-00-00 02-00-00
2 X 4 2 X 4
COMMON
8 34-00-00 14809-09-15
T2A 6.00 0.00 34-00-00
02-00-00
2 X 4 2 X 4
COMMON
6 34-00-00 14509-09-15
T2DGE 6.00 0.00 34-00-00
02-00-00 02-00-00
2 X 6 2 X 4
COMMON
2 34-00-00 17409-09-15
T3 8.00 0.00 30-00-00
02-00-00 02-00-00
2 X 4 2 X 4
COMMON
17 30-00-00 15811-08-03
T3A 8.00 0.00 29-09-00
02-00-00
2 X 4 2 X 4
COMMON 9 30-00-00 15411-08-03
T3DGE 8.00 0.00 30-00-00
02-00-00 02-00-00
2 X 6 2 X 4
COMMON
2 30-00-00 17011-08-03
V1 8.00 0.00 13-09-00 2 X 4 2 X 4
GABLE
1 13-09-00 3804-07-00
SPECIAL INSTRUCTIONS:
*BASED ON PLANS DATED 10/05/2012; AND 4/29/13 CHANGES.
*GABLES DROPPED FOR 2X6 OUTLOOKERS.
*REVIEW OVERHANG LEVEL DETAIL.
*GAS FIREPLACE.
QUOTE # QB1212002
PAGE 2
DATE QUOTED:04/29/13
VALID UNTIL: 05/27/13
PRINTED ON: 04/29/13
24 West St.
West Hatfield, MA 01088
r.k. Miles, Inc.
(413) 247-8300
Attn:RICH BLAISE
MANUFACTURERS OF ROOF & FLOOR TRUSSES
181 GOODWIN ST
PO BOX 51027
INDIAN ORCHARD, MA 01151
Phone (413) 543-1298 Fax (413) 543-1847 Toll Free (800) 456-0187
Quote To:
Phone:
Job:STIEBEL RESIDENCE
CLOVERDALE EXTENSION
NORTHAMPTON, MA
Brian TetreaultQuoted By:
Requested By:RICH BLAISE
CONTRACTOR QUOTE
QTY TYPE
SPAN LUMBER
TOP BOT
OVRHG / CANT
LEFT RIGHT
PITCH
TOP BOT TRUSS IDPROFILE
ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL
50.0,10.0,0.0,10.0
STRESS INCR.
1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)
PLY
O/ABASE
SPAN
UNIT
WEIGHT
SHIPPING HEIGHT
LAYOUTBRT 04/29/13
V2 8.00 0.00 09-09-00 2 X 4 2 X 4
Valley Truss
1 09-09-00 2603-03-00
V3 8.00 0.00 05-09-00 2 X 4 2 X 4
Valley Truss
1 05-09-00 1301-11-00
FT-IN-16
QTY LENGTH NOTES
ITEMS
CATEGORYITEM
9 HUS26 Hanger
33 LUS26 Hanger
2 THJA26 Hanger
*** THESE DRAWINGS HAVE BEEN REVIEWED AND ARE APPROVED AS AN ORDER ***
Approved By: Approval Date:
SUB-TOTAL
GRAND TOTAL
PO #:
Truss Engineering Corporation (TEC) strictly adheres to the 'Standard Responsibilities in the Design of Metal Plate
Connected Wood Trusses' as defined by TPI Chapter 2 (available upon request) regardless of any job specific
specifications unless clearly defined otherwise in writing by TEC.
This product list is Truss Engineering Corporation's INTERPRETATION of plans and drawings as supplied to us. No
responsibility is taken or implied by TEC for the structural integrity of the structure below the trusses or the affects of
TEC's product on the structure as a whole. The building owner/owner's agent is solely responsible for verifying all
dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall
be responsible for notifying TEC immediately of any discrepancies. Truss Engineering Corporation is NOT responsible for
field verification of dimensions or special conditions.
The building owner/owner's agent is responsible for coordinating all construction details between trades. The truss
installer shall follow all BCSI recommendations, construction document specifications as well as any site specific
requirements to ensure safe and proper installation. No loading shall be applied to trusses until properly and fully
installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and
permanent bracing (as required by the construction documents). Installation contractor shall refer to the individual truss
shop drawings for all structural requirements of trusses, including but not limited to bearing locations and requirements,
ply to ply nailing, lateral web bracing, and truss spacing.
No trusses supplied by Truss Engineering Corporation may be cut, drilled, or altered in any way without first contacting
TEC and receiving engineering documents allowing such.
Requested Delivery Date:
WIDE LOAD /
ESCORT FEE
M1DGEM2DGEM2DGET2DGET2DGET.O.W. 8'1-1/4"T.O.W. 7'7-1/4"TRUSSES HUNG FROM2ND FLR. RIM AND/ORBEAMT2(8)T2A(6)M1(3)M1A(11)M1B(5)T1(11)M2(8)34-00-008-00-0022-00-007-00-0091-00-0034-00-0014-00-006-00-0030-00-007-00-0030-00-0018-00-0018-00-0020-00-007-00-001-06-0016-09-0035-09-0081-00-0020-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-007-10-00Job Number:This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken orimplied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow allBCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be appliedto trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanentbracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses,including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres tothe ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specificspecifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsiblefor verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TECimmediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss EngineeringCorporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, oraltered in any way without first contacting TEC and receiving engineering documents allowing such.Quote Number: QB1212002Drawn By: Brian TetreaultJob Name:Jobsite: STIEBEL RESIDENCECLOVERDALE EXTENSION NORTHAMPTON MAValley Lines: 47.2 (ft) / Horizontal Overhang Lines: 292.04 (ft) / Raked Overhang Lines: 203.56 (ft)The following information is approximate and NOT guaranteed:Roof Sheathing Area: 4790.28 (ft²) / Ridge Lines: 122.4 (ft) / Hip Lines: 32.44 (ft)
Job
QB1212002
Truss
M1DGE
Truss Type
Monopitch Truss
Qty
1
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:56:52 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-k4AWiN5YuqnqUl?oOB9?grevMoJHeIhTLpdO5XzLuV9
Scale = 1:18.6
T1 W2
B1
W1
ST2
ST11
2
3
4
8
9
10
11
3x4
1.5x4
3x4
1.5x4
1.5x4
1.5x4
1.5x4
1.5x4
8-6-0
8-6-0
4-2-12
4-2-12
8-6-0
4-3-4
0-6-33-4-34.00 12
LUS26 FROM 2ND FLR.OR BEAMLOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL
38.5
10.00.0 *10.0
SPACING
Plates Increase
Lumber IncreaseRep Stress IncrCode
2-0-0
1.15
1.15YESIRC2009/TPI2007
CSI
TC
BCWB(Matrix)
0.32
0.480.34
DEFL
Vert(LL)
Vert(TL)Horz(TL)
in
-0.20
-0.510.01
(loc)
1-4
1-44
l/defl
>480
>192n/a
L/d
240
180n/a
PLATES
MT20
Weight: 31 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 2100F 1.8EWEBS2 X 4 SPF StudOTHERS2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1 =475/0-5-8 (min. 0-1-8)4 =475/MechanicalMax Horz1 =180(LC 7)Max Uplift1 =-134(LC 6)
4 =-163(LC 6)
Max Grav
1 =500(LC 2)
4 =544(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD1-8=-803/362, 8-9=-706/365, 2-9=-692/370
TOP CHORD1-8=-803/362, 8-9=-706/365, 2-9=-692/370BOT CHORD
1-4=-333/711
WEBS
2-4=-754/439
NOTES (13)1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-2-12 to 3-2-12,Interior(1) 3-2-12 to 5-4-4, Exterior(2) 5-4-4 to 8-4-4 zone; end vertical left and rightexposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);
Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) Gable studs spaced at 2-0-0 oc.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.
8) All bearings are assumed to be SPF No.2 .
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 1=134, 4=163.11) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) All Plates 20 Gauge Unless Noted
LOAD CASE(S)
Standard
Job
QB1212002
Truss
M1
Truss Type
MONOPITCH TRUSS
Qty
3
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:56:33 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-nQWKjtteM?OWiq28mhJYPqMVj8qeikzgzMWuw8zLuVS
Scale = 1:22.1
T1 W3
B1
W2W1
1
2
3
4
6
5
7
8 9
10
11
3x4
3x6
4x4
1.5x4
4x6
8-6-0
8-6-0
-2-0-0
2-0-0
4-3-0
4-3-0
8-6-0
4-3-0
1-0-03-10-04.00 12
LUS26 FROM 2ND FLR.OR BEAMLOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL
38.5
10.00.0 *10.0
SPACING
Plates Increase
Lumber IncreaseRep Stress IncrCode
2-0-0
1.15
1.15YESIRC2009/TPI2007
CSI
TC
BCWB(Matrix)
0.92
0.490.21
DEFL
Vert(LL)
Vert(TL)Horz(TL)
in
-0.15
-0.350.01
(loc)
5-6
5-65
l/defl
>663
>278n/a
L/d
240
180n/a
PLATES
MT20
Weight: 33 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5 =432/Mechanical6 =779/0-5-8 (min. 0-1-8)Max Horz6 =229(LC 7)Max Uplift5 =-152(LC 9)
6 =-344(LC 6)
Max Grav
5 =529(LC 2)
6 =826(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-7=-562/154, 7-8=-552/155, 8-9=-492/160, 3-9=-460/164,
TOP CHORD2-7=-562/154, 7-8=-552/155, 8-9=-492/160, 3-9=-460/164, 4-5=-272/139, 2-6=-728/435
BOT CHORD
5-6=-188/436
WEBS
3-5=-447/223
NOTES (12)1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-5-9 to 0-6-7,Interior(1) 0-6-7 to 5-4-4, Exterior(2) 5-4-4 to 8-4-4 zone; end vertical left and rightexposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times
flat roof load of 38.5 psf on overhangs non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 .
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) except (jt=lb) 5=152, 6=344.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
M1A
Truss Type
MONOPITCH TRUSS
Qty
11
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:56:45 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-RkFtEz09Xhvp8gzSTCXMuMsa2zzBWCjRkEQWLRzLuVG
Scale = 1:19.3
T1 W3
B1
W2
W1
1
2
3
4
6
5
7 8
9
10
11 3x4
4x4
4x4
1.5x4
4x4
7-0-0
7-0-0
-2-0-0
2-0-0
3-6-0
3-6-0
7-0-0
3-6-0
1-0-03-4-04.00 12
LUS26 FROM 2ND FLR.OR BEAMLOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL
38.5
10.00.0 *10.0
SPACING
Plates Increase
Lumber IncreaseRep Stress IncrCode
2-0-0
1.15
1.15YESIRC2009/TPI2007
CSI
TC
BCWB(Matrix)
0.77
0.320.10
DEFL
Vert(LL)
Vert(TL)Horz(TL)
in
-0.07
-0.150.00
(loc)
5-6
5-65
l/defl
>999
>517n/a
L/d
240
180n/a
PLATES
MT20
Weight: 28 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)5 =335/Mechanical6 =702/0-3-8 (min. 0-1-8)Max Horz6 =199(LC 7)Max Uplift5 =-126(LC 9)
6 =-325(LC 6)
Max Grav
5 =408(LC 2)
6 =742(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-7=-385/119, 7-8=-375/119, 8-9=-361/120, 3-9=-326/126,
TOP CHORD2-7=-385/119, 7-8=-375/119, 8-9=-361/120, 3-9=-326/126, 2-6=-659/422
BOT CHORD
5-6=-144/273
WEBS
3-5=-278/174
NOTES (12)1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-5-9 to 0-6-7,Interior(1) 0-6-7 to 3-10-4, Exterior(2) 3-10-4 to 6-10-4 zone; end vertical left and rightexposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times
flat roof load of 38.5 psf on overhangs non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 .
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) except (jt=lb) 5=126, 6=325.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
M1B
Truss Type
MONOPITCH TRUSS
Qty
5
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:56:49 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-JVUO4L3gbvPFdHHDi2cI3C0FzbL9R?x1esOkUCzLuVC
Scale = 1:22.1
T1
W3
B1
W2
W11
2
3
4
6
5
7 8
9
10
11 3x4
4x4
4x4
1.5x4
4x4
7-0-0
7-0-0
-2-0-0
2-0-0
3-6-0
3-6-0
7-0-0
3-6-0
1-6-03-10-04.00 12
LUS26 FROM 2ND FLR.OR BEAMLOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL
38.5
10.00.0 *10.0
SPACING
Plates Increase
Lumber IncreaseRep Stress IncrCode
2-0-0
1.15
1.15YESIRC2009/TPI2007
CSI
TC
BCWB(Matrix)
0.84
0.310.08
DEFL
Vert(LL)
Vert(TL)Horz(TL)
in
-0.07
-0.160.00
(loc)
5-6
5-65
l/defl
>999
>510n/a
L/d
240
180n/a
PLATES
MT20
Weight: 30 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except* W1: 2 X 6 SPF 1650F 1.5EBRACING
TOP CHORD
Structural wood sheathing directly applied or 5-7-10 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)5 =335/Mechanical6 =702/0-5-8 (min. 0-1-8)Max Horz6 =224(LC 7)Max Uplift5 =-132(LC 9)
6 =-319(LC 6)
Max Grav
5 =408(LC 2)
6 =742(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-7=-314/101, 7-8=-304/102, 8-9=-290/103, 2-6=-658/416
TOP CHORD2-7=-314/101, 7-8=-304/102, 8-9=-290/103, 2-6=-658/416
NOTES (12)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-5-9 to 0-6-7,
Interior(1) 0-6-7 to 3-10-4, Exterior(2) 3-10-4 to 6-10-4 zone; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members.
7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 5=132, 6=319.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the
analysis and design of this truss.
12) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
T1
Truss Type
SPECIAL TRUSS
Qty
11
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:04 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-NOu2ETF43WI7wbw65iNpAM8steS_SoOE5hX1VrzLuUz
Scale = 1:19.5
T1 T1
B1
W2
W1 W11
2
3
4
5
8
7
6
9 10
11 12
13 14
4x6
4x4
4x4
1.5x4
4x4 4x4
3-11-0
3-11-0
7-10-0
3-11-0
-2-0-0
2-0-0
3-11-0
3-11-0
7-10-0
3-11-0
9-10-0
2-0-0
1-6-02-9-111-6-04.00 12
Plate Offsets (X,Y): [2:0-2-0,0-1-12], [4:0-2-0,0-1-12], [6:Edge,0-3-8]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.670.290.04
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.07-0.120.00
(loc)
776
l/defl
>999>747n/a
L/d
240180n/a
PLATES
MT20
Weight: 30 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2 *Except*
W2: 2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)8 =694/0-5-8 (min. 0-1-8)6 =694/0-5-8 (min. 0-1-8)Max Horz8 =50(LC 8)Max Uplift
8 =-328(LC 8)
6 =-328(LC 9)
Max Grav
8 =708(LC 2)6 =708(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-8=-615/440, 4-6=-615/441
TOP CHORD2-8=-615/440, 4-6=-615/441
NOTES (11)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-5-9 to 0-6-7,
Interior(1) 0-6-7 to 0-11-0, Exterior(2) 0-11-0 to 3-11-0, Interior(1) 6-11-0 to 7-3-9 zone;end vertical left and right exposed;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with
any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 8=328, 6=328.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the
analysis and design of this truss. 11) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
M2
Truss Type
MONOPITCH TRUSS
Qty
8
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:56:58 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-YEXnzQAJTgYzCgTykRGPw6uqODQQ25UMjl4iJBzLuV3
Scale = 1:17.4
T1 W2
B1
W1
1
2
3
5 4
6
7
8
3x6
2x4 3x4
4x4
6-0-0
6-0-0
-2-0-0
2-0-0
6-0-0
6-0-0
1-0-03-0-04.00 12
LUS26 FROM 2ND FLR.OR BEAMPlate Offsets (X,Y): [2:0-2-0,0-1-12]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.670.240.00
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.04-0.100.00
(loc)
4-54-54
l/defl
>999>715n/a
L/d
240180n/a
PLATES
MT20
Weight: 21 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF No.2 *Except*
W2: 2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)4 =276/Mechanical5 =645/0-3-8 (min. 0-1-8)Max Horz5 =178(LC 7)Max Uplift
4 =-108(LC 9)
5 =-307(LC 6)
Max Grav
4 =335(LC 2)5 =680(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD3-4=-272/146, 2-5=-628/419
TOP CHORD3-4=-272/146, 2-5=-628/419
NOTES (12)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-5-9 to 0-6-7,
Interior(1) 0-6-7 to 2-10-4, Exterior(2) 2-10-4 to 5-10-4 zone; end vertical left and rightexposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with
any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 4=108, 5=307.
10) This truss is designed in accordance with the 2009 International Residential Code
sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
M2DGE
Truss Type
GABLE
Qty
2
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:01 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-zpDwbSCCmbwY37BXPZp6YkWJMQUCFR4oPjINvWzLuV0
Scale = 1:15.0
T1
W1
B1
ST1
1
2
3
4
6 5
7
8
9
1.5x4
1.5x4 3x4 1.5x4
1.5x4
6-0-0
6-0-0
-2-0-0
2-0-0
6-0-0
6-0-0
0-6-32-6-32-11-114.00 12
TOP CHORD DROPPEDFOR 2X6 OUTLOOKERS
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL
38.5
10.00.0 *10.0
SPACING
Plates Increase
Lumber IncreaseRep Stress IncrCode
2-0-0
1.15
1.15YESIRC2009/TPI2007
CSI
TC
BCWB(Matrix)
0.81
0.110.07
DEFL
Vert(LL)
Vert(TL)Horz(TL)
in
-0.24
-0.300.00
(loc)
1
15
l/defl
n/r
n/rn/a
L/d
120
90n/a
PLATES
MT20
Weight: 21 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudOTHERS2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)5 =68/6-0-0 (min. 0-1-10)2 =528/6-0-0 (min. 0-1-10)6 =328/6-0-0 (min. 0-1-10)Max Horz2 =148(LC 7)Max Uplift
5 =-34(LC 8)
2 =-282(LC 6)
6 =-144(LC 9)
Max Grav5 =76(LC 2)2 =538(LC 2)6 =404(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS3-6=-322/197
NOTES (14)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -2-5-9 to 0-6-7,
Exterior(2) 0-6-7 to 2-10-4, Corner(3) 2-10-4 to 5-10-4 zone; end vertical left and rightexposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times
flat roof load of 38.5 psf on overhangs non-concurrent with other live loads.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.
10) All bearings are assumed to be SPF No.2 .
11) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) 5 except (jt=lb) 2=282, 6=144.12) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 14) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
T2
Truss Type
COMMON TRUSS
Qty
8
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:16 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-1idblaOcECpQMRrPoDbefuerxTPJG6u?sYRfw8zLuUn
Scale = 1:57.0
T2
T1
B1
W4 W3
W2
W1
W3
W2
W1HW1
HW1
B1
T1
T2
1
2
3
4
5
6
7
8
9
10
11
12
13
16 15 14
17
18
19
20 21
22
23
24
25 26 27 28
4x12
5x6
4x12
6x9
3x6
3x6
6x9
3x4
3x4
1.5x4
3x4
3x4
1.5x4
6x9
3x6
3x6
8-7-12
8-7-12
17-0-0
8-4-4
25-4-4
8-4-4
34-0-0
8-7-12
-2-0-0
2-0-0
5-10-5
5-10-5
11-5-3
5-6-13
17-0-0
5-6-13
22-6-13
5-6-13
28-1-11
5-6-13
34-0-0
5-10-5
36-0-0
2-0-0
0-8-89-2-89-9-150-8-86.00 12
Plate Offsets (X,Y): [2:0-4-9,Edge], [5:0-6-0,Edge], [9:0-6-0,Edge], [12:0-4-9,Edge], [15:0-4-8,0-3-4]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
17.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.920.840.52
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.34-0.640.20
(loc)
14-1514-1512
l/defl
>999>637n/a
L/d
240180n/a
PLATES
MT20
Weight: 148 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except*
W4: 2 X 4 SPF No.2
SLIDER
Left 2 X 4 SPF No.2 3-2-14,
Right 2 X 4 SPF No.2 3-2-14
BRACING
TOP CHORDStructural wood sheathing directly applied or 2-1-8 oc purlins.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.WEBS1 Row at midpt 8-15, 6-15
REACTIONS (lb/size)
12 =2601/0-5-8 (min. 0-4-1)
2 =2601/0-5-8 (min. 0-4-1)
Max Horz
2 =144(LC 7)Max Uplift12 =-598(LC 9)2 =-598(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD
2-17=-4054/775, 3-17=-3887/777, 3-4=-3885/793,
4-18=-3630/760, 5-18=-3542/764, 5-19=-3541/765,
6-19=-3405/777, 6-20=-2721/687, 7-20=-2565/706,
7-21=-2565/706, 8-21=-2721/687, 8-22=-3405/777,
9-22=-3541/765, 9-23=-3542/764, 10-23=-3630/760, 10-11=-3885/793, 11-24=-3887/777, 12-24=-4054/775BOT CHORD2-16=-505/3373, 16-25=-401/2962, 25-26=-401/2962, 15-26=-401/2962, 15-27=-401/2962, 27-28=-401/2962, 14-28=-401/2962, 12-14=-502/3373WEBS7-15=-369/1756, 8-15=-1187/301, 8-14=-80/497, 10-14=-311/218,6-15=-1187/301, 6-16=-80/497, 4-16=-311/217
NOTES (11)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-3-15 to 1-0-14,Interior(1) 1-0-14 to 13-7-3, Exterior(2) 13-7-3 to 17-0-0, Interior(1) 20-4-13 to 32-11-2zone; end vertical left and right exposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) except (jt=lb) 12=598, 2=598.
9) This truss is designed in accordance with the 2009 International Residential Code
sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
T2A
Truss Type
COMMON TRUSS
Qty
6
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:24 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-oE6cQJUdLgpHKfSyFvkWzazDoh8C8jTBioN4CgzLuUf
Scale = 1:55.7
T2
T3
B1
W4 W3
W2
W1
W3
W2
W1HW1
HW1
B1
T1
1
2
3
4
5
6
7
8
9
10
11
14 13 12
15
16
17
18 19
20
21
22
23 24 25 26
4x12
5x6
6x9
3x6
3x6
6x9
3x4
3x4
1.5x4
3x4
3x4
1.5x4
6x9
3x6
3x6
8-7-12
8-7-12
17-0-0
8-4-4
25-4-4
8-4-4
34-0-0
8-7-12
-2-0-0
2-0-0
5-10-5
5-10-5
11-5-3
5-6-13
17-0-0
5-6-13
22-6-13
5-6-13
28-1-11
5-6-13
34-0-0
5-10-5
0-8-89-2-89-9-150-8-86.00 12
Plate Offsets (X,Y): [2:0-4-9,Edge], [5:0-6-0,Edge], [11:0-4-9,Edge], [13:0-4-8,0-3-4]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
17.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.920.830.54
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.34-0.640.20
(loc)
13-1413-1411
l/defl
>999>634n/a
L/d
240180n/a
PLATES
MT20
Weight: 145 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except*
W4: 2 X 4 SPF No.2
SLIDER
Left 2 X 4 SPF No.2 3-2-14,
Right 2 X 4 SPF No.2 3-2-14
BRACING
TOP CHORDStructural wood sheathing directly applied or 2-0-11 oc purlins.BOT CHORDRigid ceiling directly applied or 8-9-3 oc bracing.WEBS1 Row at midpt 8-13, 6-13
REACTIONS (lb/size)
11 =2334/0-5-8 (min. 0-3-11)
2 =2610/0-5-8 (min. 0-4-2)
Max Horz
2 =174(LC 7)Max Uplift11 =-433(LC 9)2 =-600(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD
2-15=-4072/798, 3-15=-3904/800, 3-4=-3902/816,
4-16=-3648/783, 5-16=-3560/788, 5-17=-3559/799,
6-17=-3395/801, 6-18=-2740/711, 7-18=-2584/730,
7-19=-2584/729, 8-19=-2739/716, 8-20=-3469/860,
20-21=-3602/848, 9-21=-3722/841, 9-22=-3931/892, 10-22=-3961/883, 10-11=-4112/875BOT CHORD2-14=-571/3389, 14-23=-472/2979, 23-24=-472/2979, 13-24=-472/2979, 13-25=-492/2994, 25-26=-492/2994, 12-26=-492/2994, 11-12=-663/3459WEBS7-13=-388/1770, 8-13=-1211/331, 8-12=-116/548, 9-12=-359/251,6-13=-1153/301, 6-14=-80/496, 4-14=-309/217
NOTES (11)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-3-15 to 1-0-14,Interior(1) 1-0-14 to 13-7-3, Exterior(2) 13-7-3 to 17-0-0, Interior(1) 20-4-13 to 30-7-3zone; end vertical left and right exposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) except (jt=lb) 11=433, 2=600.
9) This truss is designed in accordance with the 2009 International Residential Code
sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
T2DGE
Truss Type
COMMON TRUSS
Qty
2
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:30 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-cOTthMZOxWaR2av6c9rwDrDKl6MFYT234kqPQKzLuUZ
Scale = 1:55.6
W1
T2 T2
W1
B1
ST8ST7ST6ST5ST4ST3ST2ST1
ST7 ST6 ST5 ST4 ST3 ST2 ST1
T1 T1
B11
2
3
4
5
6 7
8
9
10
11
12
13
14
15 16
17
18
19
20
21
38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22
39
40
41 42
43
44
4x9
3x4
4x4
3x4
4x9
5x6
34-0-0
34-0-0
-2-0-0
2-0-0
17-0-0
17-0-0
34-0-0
17-0-0
36-0-0
2-0-0
0-8-89-2-89-9-150-8-86.00 12
TOP CHORD DROPPED FOR 2X6 OUTLOOKERS
Plate Offsets (X,Y): [20:0-3-8,Edge], [30:0-3-0,0-3-0], [38:0-3-8,Edge]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.570.150.41
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.16-0.210.02
(loc)
212122
l/defl
n/rn/rn/a
L/d
12090n/a
PLATES
MT20
Weight: 174 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2WEBS2 X 6 SPF 1650F 1.5E
OTHERS 2 X 4 SPF Stud *Except*
ST8: 2 X 4 SPF No.2
BRACING
TOP CHORD
Structural wood sheathing directly applied or 10-0-0 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing.WEBS1 Row at midpt 11-30
REACTIONS All bearings 34-0-0.(lb) - Max Horz38= 155(LC 7)
Max Uplift
All uplift 100 lb or less at joint(s) 31, 32, 33, 34, 35, 37,
29, 28, 27, 26, 25, 23 except 38=-213(LC 8), 22=-235(LC 9),
36=-122(LC 8), 24=-126(LC 9)Max GravAll reactions 250 lb or less at joint(s) 37, 23 except 38=462(LC 2), 22=462(LC 3), 30=421(LC 1), 31=435(LC 2), 32=415(LC 2), 33=383(LC 2), 34=321(LC 1), 35=268(LC 1),
REACTIONSMax GravAll reactions 250 lb or less at joint(s) 37, 23 except
38=462(LC 2), 22=462(LC 3), 30=421(LC 1), 31=435(LC 2),
32=415(LC 2), 33=383(LC 2), 34=321(LC 1), 35=268(LC 1),
36=258(LC 2), 29=435(LC 3), 28=415(LC 3), 27=383(LC 3),
26=321(LC 1), 25=268(LC 1), 24=258(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-38=-407/325, 10-11=0/328, 11-12=0/328, 20-22=-407/325BOT CHORD37-38=-173/407, 36-37=-173/407, 35-36=-173/407, 34-35=-173/407, 33-34=-173/407, 32-33=-173/407, 31-32=-173/407, 30-31=-173/407, 29-30=-173/407, 28-29=-173/407, 27-28=-173/407, 26-27=-173/407,
25-26=-173/407, 24-25=-173/407, 23-24=-173/407,
22-23=-173/407
WEBS
11-30=-301/0, 10-31=-315/215, 9-32=-294/161, 8-33=-265/129, 12-29=-315/215, 13-28=-294/161, 14-27=-265/129
NOTES (16)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -2-3-15 to 1-0-14,Exterior(2) 1-0-14 to 13-7-3, Corner(3) 13-7-3 to 17-0-0, Exterior(2) 20-4-13 to 32-11-2zone; end vertical left and right exposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);
Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times
flat roof load of 38.5 psf on overhangs non-concurrent with other live loads.6) All plates are 1.5x4 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement(i.e. diagonal web).9) Gable studs spaced at 2-0-0 oc.10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads.11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members, with BCDL = 10.0psf.Continued on page 2
Job
QB1212002
Truss
T2DGE
Truss Type
COMMON TRUSS
Qty
2
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:30 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-cOTthMZOxWaR2av6c9rwDrDKl6MFYT234kqPQKzLuUZ
NOTES (16)
12) All bearings are assumed to be SPF No.2 .
13) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) 31, 32, 33, 34, 35, 37, 29, 28, 27, 26, 25, 23 except(jt=lb) 38=213, 22=235, 36=122, 24=126.14) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.15) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 16) All Plates 20 Gauge Unless Noted
LOAD CASE(S)
Standard
G1G2CJ1CJ101010101V1V2V3T3DGET3DGET3(17)T3A(9)02(5)30-00-007-00-0037-00-0030-00-007-00-0037-00-0054-00-001-06-0016-09-0035-09-0054-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-002-00-00Job Number:This non‐structural placement plan is provided for identifying the location of trusses as supplied by Truss Engineering Corporation (TEC). No responsibility is taken orimplied by TEC for the structural integrity of the structure below the trusses or the affects of TEC’s product on the structure as a whole. The truss installer shall follow allBCSI recommendations, construction document specifications as well as any site specific requirements to ensure safe and proper installation. No loading shall be appliedto trusses until properly and fully installed, including all sheathing, hangers, wall anchors, lateral web bracing (as shown on individual shop drawings), and permanentbracing (as required by the construction documents). Installation contractor shall refer to the individual truss shop drawings for all structural requirements of trusses,including but not limited to bearing locations and requirements, ply to ply nailing, lateral web bracing, and truss spacing. Truss Engineering Corporation strictly adheres tothe ‘Standard Responsibilities in the Design of Metal Plate Connected Wood Trusses’ as defined by TPI Chapter 2 (available upon request) regardless of any job specificspecifications unless clearly defined otherwise in writing by TEC.This placement plan is Truss Engineering Corporation’sINTERPRETATION of plans and drawings as supplied to us. The building owner/owner’s agent is solely responsiblefor verifying all dimensions, geometry, loads and load requirements for accuracy and full compliance to construction documents and shall be responsible for notifying TECimmediately of any discrepancies. The building owner/owner’s agent is responsible for coordinating all construction details between trades. Truss EngineeringCorporation isNOT responsible for field verification of dimensions or special conditions. No trusses supplied by Truss Engineering Corporation may be cut, drilled, oraltered in any way without first contacting TEC and receiving engineering documents allowing such.Quote Number: QB1212002Drawn By: Brian TetreaultJob Name:Jobsite: STIEBEL RESIDENCECLOVERDALE EXTENSION NORTHAMPTON MAValley Lines: 47.2 (ft) / Horizontal Overhang Lines: 292.04 (ft) / Raked Overhang Lines: 203.56 (ft)The following information is approximate and NOT guaranteed:Roof Sheathing Area: 4790.28 (ft²) / Ridge Lines: 122.4 (ft) / Hip Lines: 32.44 (ft)
Job
QB1212002
Truss
01
Truss Type
JACK-CLOSED TRUSS
Qty
4
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:56:17 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-FLZHMPgb74NonNq4qK1omSirbhTpyYKJIte2M3zLuVi
Scale = 1:18.0
W1
T1
W2
B1
1
2
3
5
4
3x4
4x6
3x4
1.5x4
2-10-15
2-10-15
-2-0-0
2-0-0
2-10-15
2-10-15
1-3-03-2-53-7-88.00 12
Plate Offsets (X,Y): [2:0-3-0,Edge]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.610.110.00
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
0.00-0.000.00
(loc)
4-54-54
l/defl
>999>999n/a
L/d
240180n/a
PLATES
MT20
Weight: 15 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 2-10-15 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)5 =494/0-3-8 (min. 0-1-8)4 =46/MechanicalMax Horz5 =184(LC 7)Max Uplift5 =-243(LC 8)
4 =-82(LC 7)
Max Grav
5 =494(LC 1)
4 =103(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-5=-445/334
TOP CHORD2-5=-445/334
NOTES (12)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical left
and right exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members.
7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 4 except (jt=lb) 5=243.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the
analysis and design of this truss. 12) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
02
Truss Type
JACK-CLOSED TRUSS
Qty
5
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:56:24 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-YiUxqom_UEFo7RsQlIfRYxU2tWrK5j3LvTrv69zLuVb
Scale = 1:24.4
W1
T1 W2
B11
2
3
5
4
3x4
4x6
3x4
2x4
5-0-0
5-0-0
-2-0-0
2-0-0
5-0-0
5-0-0
1-3-04-7-05-0-38.00 12
Plate Offsets (X,Y): [2:0-3-0,Edge]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.610.180.00
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.02-0.050.00
(loc)
4-54-54
l/defl
>999>999n/a
L/d
240180n/a
PLATES
MT20
Weight: 21 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)5 =569/0-3-8 (min. 0-1-8)4 =216/MechanicalMax Horz5 =258(LC 7)Max Uplift5 =-240(LC 8)
4 =-121(LC 7)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD2-5=-519/358
NOTES (12)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with
any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 5=240, 4=121.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the
analysis and design of this truss.
12) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
CJ1
Truss Type
DIAGONAL HIP GIRDER
Qty
2
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:47:54 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-Uaf7oPb4aX?9x3tPsBVrtOMx9wnab2ZHd7IwCjzLudZ
Scale = 1:28.4
W1
T1 W5
B1
W2
W3 W4
1
2
3
4
7 6 58
3x6
2x4
3x6
4x4
3x4
3x4
Nailed
Nailed
3-5-11
3-5-11
6-11-6
3-5-11
-2-9-15
2-9-15
3-5-11
3-5-11
6-11-6
3-5-11
1-3-04-6-55-1-65.66 12
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL
38.5
10.00.0 *10.0
SPACING
Plates Increase
Lumber IncreaseRep Stress IncrCode
2-0-0
1.15
1.15NOIRC2009/TPI2007
CSI
TC
BCWB(Matrix-M)
0.44
0.150.08
DEFL
Vert(LL)
Vert(TL)Horz(TL)
in
0.02
-0.01-0.00
(loc)
5-6
5-65
l/defl
>999
>999n/a
L/d
240
180n/a
PLATES
MT20
Weight: 45 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 6 SPF 1650F 1.5EBOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size)7 =840/0-4-9 (min. 0-1-8)5 =331/MechanicalMax Horz7 =270(LC 6)Max Uplift7 =-463(LC 7)5 =-219(LC 6)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD
2-7=-817/489, 2-3=-338/165BOT CHORD6-7=-257/0
NOTES (14)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed;Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members.
7) All bearings are assumed to be SPF No.2 . 8) Refer to girder(s) for truss to truss connections.9) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 463 lb uplift at joint 7 and 219 lb uplift at joint 5.10) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) "Nailed" indicates 3-10d or 2-12d common wire toe-nails. For more details refer to
MiTek's ST-TOENAIL Detail.
13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as
front (F) or back (B).
14) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-97, 2-4=-97, 5-7=-20Concentrated Loads (lb)Vert: 8=-52(F=-26, B=-26)
Job
QB1212002
Truss
G1
Truss Type
HIP TRUSS
Qty
1
Ply
2
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:48:20 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-jaEyFIvOTWHT33sOOfzxwsRM9PehhkV6c9bI7CzLud9
NOTES (18)
16) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Left Hand Hip) or equivalent at
11-8-10 from the left end to connect truss(es) 02 (1 ply 2 X 4 SPF), CJ1 (1 ply 2 X 4 SPF)
to back face of bottom chord. 17) Fill all nail holes where hanger is in contact with lumber.18) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15Uniform Loads (plf)Vert: 1-2=-97, 2-4=-97, 4-5=-97, 6-10=-20
Concentrated Loads (lb)
Vert: 9=-507(B) 8=-196(B) 7=-507(B) 15=-196(B) 16=-196(B)
Job
QB1212002
Truss
G1
Truss Type
HIP TRUSS
Qty
1
Ply
2
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:48:20 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-jaEyFIvOTWHT33sOOfzxwsRM9PehhkV6c9bI7CzLud9
Scale = 1:27.7
T1
T2
T1
B1
W3 W4 W3 W4 W3
W1
W2
W1
W2
1
2 3 4
5
10 9 8 7 6
11 12 13 14
15 16
4x4
4x9 4x9
4x4
3x8 3x8 4x4 3x8
1.5x4
4x4
THJA26
LUS26
LUS26
LUS26
THJA26
5-0-0
5-0-0
8-4-8
3-4-8
11-9-0
3-4-8
16-9-0
5-0-0
5-0-0
5-0-0
8-4-8
3-4-8
11-9-0
3-4-8
16-9-0
5-0-0
1-3-04-7-01-3-04-7-08.00 12
Plate Offsets (X,Y): [1:Edge,0-1-12], [2:0-6-12,0-2-0], [4:0-6-12,0-2-0], [5:Edge,0-1-12]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15NOIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.470.150.37
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.03-0.050.01
(loc)
886
l/defl
>999>999n/a
L/d
240180n/a
PLATES
MT20
Weight: 177 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SPF 1650F 1.5EWEBS2 X 4 SPF Stud *Except*
W1: 2 X 4 SPF No.2BRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and
2-0-0 oc purlins (6-0-0 max.): 2-4.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)10 =1763/0-3-8 (min. 0-1-8)6 =1763/0-3-8 (min. 0-1-8)Max Horz10 =-191(LC 5)
Max Uplift
10 =-792(LC 7)
6 =-792(LC 8)
Max Grav10 =1915(LC 16)6 =1915(LC 16)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD1-2=-2316/1033, 2-11=-2326/1077, 11-12=-2325/1077,
3-12=-2324/1077, 3-13=-2324/1077, 13-14=-2325/1077,
4-14=-2326/1077, 4-5=-2316/1033, 1-10=-1839/801,
5-6=-1839/801
BOT CHORD
9-10=-265/339, 9-15=-945/1861, 8-15=-945/1861, 8-16=-850/1861, 7-16=-850/1861, 6-7=-118/339WEBS2-9=-218/375, 2-8=-408/740, 3-8=-608/202, 4-8=-408/740, 4-7=-218/375, 1-9=-825/1711, 5-7=-830/1711
NOTES (18)1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or
back (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed;Lumber DOL=1.33 plate grip DOL=1.33
4) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);
Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-05) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding.7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.9) All bearings are assumed to be SPF No.2 .
10) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 792 lb uplift at joint 10 and 792 lb uplift at joint 6.
11) This truss is designed in accordance with the 2009 International Residential Code
sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 13) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened totruss TC w/ 2-10d nails.14) Use Simpson Strong-Tie THJA26 (THJA26 on 2 ply, Right Hand Hip) or equivalentat 5-0-6 from the left end to connect truss(es) 02 (1 ply 2 X 4 SPF), CJ1 (1 ply 2 X 4SPF) to back face of bottom chord. 15) Use Simpson Strong-Tie LUS26 (4-10d Girder, 3-10d Truss, Single Ply Girder) or
equivalent spaced at 1-3-12 oc max. starting at 7-0-12 from the left end to 9-8-4 to
connect truss(es) 02 (1 ply 2 X 4 SPF) to back face of bottom chord. Continued on page 2
Job
QB1212002
Truss
G2
Truss Type
HIP TRUSS
Qty
1
Ply
2
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:48:29 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-yJHM8N01LHPBeS27Q2d2omJsu1fBIg7Rg3HGxBzLud0
Scale = 1:37.8
T1
T2
T1
B1
W3 W4
W5 W6 W5
W4 W3W1
W2
W1
W2
B2
SB1
1
2
3 4
5
6
13 12 11 10 9 8 7
14
15 16
17
18 19 20 21 22 23 24
5x9
5x12 MT18H
5x9
4x9 7x8 WB
3x6
7x8 7x8
5x12 MT18H
8x9
3x6
7x8 4x9
HUS26
HUS26
HUS26 HUS26
HUS26
HUS26
HUS26
HUS26 HUS26
3-7-12
3-7-12
7-0-0
3-4-4
9-9-0
2-9-0
13-1-4
3-4-4
16-9-0
3-7-12
3-7-12
3-7-12
7-0-0
3-4-4
9-9-0
2-9-0
13-1-4
3-4-4
16-9-0
3-7-12
1-3-05-11-01-3-05-11-08.00 12
Plate Offsets (X,Y): [1:0-4-8,0-1-12], [4:0-5-0,Edge], [6:0-4-8,0-1-12], [7:0-4-8,0-0-10], [8:0-3-4,0-4-8], [9:0-4-8,0-4-12], [10:0-4-0,0-4-12], [12:0-3-0,0-4-12], [13:0-4-8,0-2-6]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15NOIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.600.440.92
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.10-0.180.03
(loc)
10-1210-127
l/defl
>999>999n/a
L/d
240180n/a
PLATES
MT20MT18H
Weight: 219 lb FT = 10%
GRIP
197/144197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 6 SYP 2400F 2.0EWEBS2 X 4 SPF Stud *Except*
W1: 2 X 8 SYP DSS, W2: 2 X 4 SPF No.2
OTHERS 2 X 4 SPF Stud
BRACING
TOP CHORD
Structural wood sheathing directly applied or 3-7-7 oc purlins, except end verticals, and2-0-0 oc purlins (4-7-15 max.): 3-4.BOT CHORDRigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)13 =10058/0-3-8 (req. 0-8-3)7 =10168/0-3-8 (req. 0-8-4)Max Horz
13 =-248(LC 5)
Max Uplift
13 =-2024(LC 7)
7 =-2046(LC 8)Max Grav13 =10445(LC 16)7 =10556(LC 16)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD
1-14=-9408/1817, 2-14=-9229/1825, 2-15=-8358/1680,
3-15=-8116/1687, 3-4=-6773/1437, 4-16=-8203/1704,
5-16=-8445/1697, 5-17=-9236/1827, 6-17=-9414/1819,
1-13=-7529/1472, 6-7=-7520/1470
BOT CHORD13-18=-401/969, 12-18=-401/969, 12-19=-1563/7690, 11-19=-1563/7690, 11-20=-1563/7690, 10-20=-1563/7690, 10-21=-1334/6698, 9-21=-1334/6698, 9-22=-1425/7694, 22-23=-1425/7694, 8-23=-1425/7694, 8-24=-193/1024, 7-24=-193/1024WEBS2-12=-196/1100, 2-10=-1262/353, 3-10=-840/4112, 3-9=-140/281,4-9=-850/4268, 5-9=-1155/332, 5-8=-178/997, 1-12=-1306/7042,
6-8=-1298/6989
NOTES (18)
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2 X 4 - 1 row at 0-4-0 oc, 2 X 8 - 2 rows at 0-9-0 oc.Bottom chords connected as follows: 2 X 6 - 2 rows at 0-5-0 oc.Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or
back (B) face in the LOAD CASE(S) section. Ply to ply connections have been providedto distribute only loads noted as (F) or (B), unless otherwise indicated.3) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone; end vertical left and right exposed;Lumber DOL=1.33 plate grip DOL=1.334) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.1, Lu=50-0-05) Unbalanced snow loads have been considered for this design. 6) Provide adequate drainage to prevent water ponding.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with
any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members.10) WARNING: Required bearing size at joint(s) 13, 7 greater than input bearing size.11) All bearings are assumed to be SPF No.2 . 12) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 2024 lb uplift at joint 13 and 2046 lb uplift at joint 7.13) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
14) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the
analysis and design of this truss. Continued on page 2
Job
QB1212002
Truss
G2
Truss Type
HIP TRUSS
Qty
1
Ply
2
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:48:29 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-yJHM8N01LHPBeS27Q2d2omJsu1fBIg7Rg3HGxBzLud0
NOTES (18)
15) Design assumes 4x2 (flat orientation) purlins at oc spacing indicated, fastened to truss
TC w/ 2-10d nails.
16) Use Simpson Strong-Tie HUS26 (14-10d Girder, 6-10d Truss) or equivalent spaced at2-1-10 oc max. starting at 0-3-10 from the left end to 16-5-6 to connect truss(es) T3A (1ply 2 X 4 SPF) to front face of bottom chord. 17) Fill all nail holes where hanger is in contact with lumber.18) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard1) Snow: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-97, 3-4=-97, 4-6=-97, 7-13=-20
Concentrated Loads (lb)
Vert: 13=-2037(F) 7=-2037(F) 18=-2037(F) 19=-2037(F) 20=-2037(F) 21=-2037(F)
22=-2037(F) 23=-2037(F) 24=-2037(F)
Job
QB1212002
Truss
T3
Truss Type
COMMON TRUSS
Qty
17
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:46 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-8TRx2qlQAQb9y28AYW7gtDt1AZgSIb6QlDiF_PzLuUJ
Scale = 1:62.8
T1 T1
B1
W6 W5
W4
W3
W5
W4
W3W1
W2
W1
W2
B1
T2
T2
1
2
3
4
5
6
7
8
9
14 13 12 11 10
15
16
17
18 19
20
21
22
23 24 25 26
5x8
4x6
4x4
3x4
6x6
4x4
3x4
6x6
6x6
4x6 4x6
6x6
7-7-12
7-7-12
15-0-0
7-4-4
22-4-4
7-4-4
30-0-0
7-7-12
-2-0-0
2-0-0
5-2-5
5-2-5
10-1-3
4-10-13
15-0-0
4-10-13
19-10-13
4-10-13
24-9-11
4-10-13
30-0-0
5-2-5
32-0-0
2-0-0
1-3-011-3-011-8-31-3-08.00 12
Plate Offsets (X,Y): [2:0-3-0,Edge], [3:0-2-8,0-3-0], [7:0-2-8,0-3-0], [8:0-3-0,Edge], [12:0-4-0,0-3-0]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
17.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.670.830.85
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.20-0.350.11
(loc)
12-1312-1310
l/defl
>999>999n/a
L/d
240180n/a
PLATES
MT20
Weight: 159 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except*
W6,W5,W1: 2 X 4 SPF No.2BRACING
TOP CHORD
Structural wood sheathing directly applied or 3-3-7 oc purlins, except end verticals.
BOT CHORDRigid ceiling directly applied or 9-8-5 oc bracing.WEBS1 Row at midpt 6-12, 4-12, 3-14, 7-10
REACTIONS (lb/size)14 =2351/0-3-8 (req. 0-3-11)10 =2351/0-3-8 (req. 0-3-11)Max Horz
14 =481(LC 7)
Max Uplift
14 =-544(LC 8)
10 =-544(LC 9)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-15=-277/132, 3-16=-2463/531, 16-17=-2318/551,
TOP CHORD2-15=-277/132, 3-16=-2463/531, 16-17=-2318/551,
4-17=-2156/552, 4-18=-1917/529, 5-18=-1752/543,
5-19=-1752/543, 6-19=-1917/529, 6-20=-2156/552,
20-21=-2318/551, 7-21=-2463/531, 8-22=-277/132,
2-14=-639/371, 8-10=-639/371
BOT CHORD13-14=-363/1976, 13-23=-236/1831, 23-24=-236/1831, 12-24=-236/1831, 12-25=-93/1831, 25-26=-93/1831, 11-26=-93/1831, 10-11=-186/1976WEBS5-12=-401/1452, 6-12=-838/279, 6-11=-100/321, 4-12=-838/279, 4-13=-100/321, 3-14=-2517/416, 7-10=-2517/416
NOTES (12)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-3-2 to 0-8-14,
Interior(1) 0-8-14 to 12-0-0, Exterior(2) 12-0-0 to 15-0-0, Interior(1) 18-0-0 to 29-3-2
zone; end vertical left and right exposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times
flat roof load of 38.5 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) WARNING: Required bearing size at joint(s) 14, 10 greater than input bearing size.8) All bearings are assumed to be SPF No.2 . 9) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) except (jt=lb) 14=544, 10=544.
10) This truss is designed in accordance with the 2009 International Residential Code
sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
11) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 12) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
T3A
Truss Type
COMMON TRUSS
Qty
9
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:57:50 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-1FgRtCoxDf5bRfRynMCc132j2A1PEPt0grgS7AzLuUF
Scale = 1:61.9
T1
T3
B2
W6 W5
W4
W3
W5
W4
W3W1
W2
W8
W7
B1
T2
1
2
3
4
5
6
7
8
13 12 11 10 9
14
15
16 17
18
19
20
21 22 23 24
4x6
3x6
5x8
4x4
3x4
4x6
4x4
3x4
6x6
6x6
4x6
6x6
7-7-12
7-7-12
15-0-0
7-4-4
22-4-4
7-4-4
29-9-0
7-4-12
-2-0-0
2-0-0
5-2-5
5-2-5
10-1-3
4-10-13
15-0-0
4-10-13
19-10-13
4-10-13
24-9-11
4-10-13
29-9-0
4-11-5
1-3-011-3-011-8-31-5-08.00 12
Plate Offsets (X,Y): [2:0-3-0,Edge], [3:0-2-8,0-3-0], [11:0-4-0,0-3-4]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
17.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.680.830.86
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.20-0.340.11
(loc)
11-1211-129
l/defl
>999>999n/a
L/d
240180n/a
PLATES
MT20
Weight: 155 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 4 SPF Stud *Except*
W6,W5,W1,W8: 2 X 4 SPF No.2BRACING
TOP CHORD
Structural wood sheathing directly applied or 3-2-6 oc purlins, except end verticals.
BOT CHORDRigid ceiling directly applied or 9-2-9 oc bracing.WEBS1 Row at midpt 6-11, 4-11, 3-13, 7-9
REACTIONS (lb/size)13 =2344/0-3-8 (req. 0-3-11)9 =2057/MechanicalMax Horz
13 =519(LC 7)
Max Uplift
13 =-544(LC 8)
9 =-371(LC 9)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-14=-273/132, 3-15=-2454/539, 4-15=-2309/560, 4-16=-1907/538,
TOP CHORD2-14=-273/132, 3-15=-2454/539, 4-15=-2309/560,
4-16=-1907/538, 5-16=-1741/552, 5-17=-1741/551,
6-17=-1905/537, 6-18=-2135/583, 18-19=-2292/581,
7-19=-2442/562, 8-20=-338/165, 2-13=-636/371, 8-9=-362/192
BOT CHORD
12-13=-402/1968, 12-21=-276/1823, 21-22=-276/1823, 11-22=-276/1823, 11-23=-174/1813, 23-24=-174/1813, 10-24=-174/1813, 9-10=-288/1948WEBS5-11=-408/1437, 6-11=-820/288, 6-10=-121/310, 4-11=-815/278, 4-12=-100/322, 3-13=-2507/423, 7-9=-2425/377
NOTES (13)1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) -2-3-2 to 0-8-14,
Interior(1) 0-8-14 to 12-0-0, Exterior(2) 12-0-0 to 15-0-0, Interior(1) 18-0-0 to 26-7-4
zone; end vertical left and right exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 timesflat roof load of 38.5 psf on overhangs non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with
any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in allareas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) WARNING: Required bearing size at joint(s) 13 greater than input bearing size.8) All bearings are assumed to be SPF No.2 . 9) Refer to girder(s) for truss to truss connections.10) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) except (jt=lb) 13=544, 9=371.
11) This truss is designed in accordance with the 2009 International Residential Code
sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
12) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in the
analysis and design of this truss. 13) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
T3DGE
Truss Type
COMMON TRUSS
Qty
2
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 11:00:53 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-ASEdIn0j7t8dunx7?I_Wyf70dxeacI8xlpVe23zLuRO
Scale = 1:61.9
W1
T2 T2
W1
B1
ST7ST6
ST5
ST4
ST3ST2
ST1
ST6
ST5
ST4
ST3 ST2
ST1T1 T1
B11
2
3
4
5
6
7
8
9
10
11
12
13
14
15 16
17
18
19
34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
35
36 37
38
4x9
5x6
4x4
5x6
4x9 5x6
30-0-0
30-0-0
-2-0-0
2-0-0
15-0-0
15-0-0
30-0-0
15-0-0
32-0-0
2-0-0
0-8-610-8-611-8-30-8-68.00 12
TOP CHORD DROPPED
FOR 2X6 OUTLOOKERS
Plate Offsets (X,Y): [5:0-3-0,0-3-4], [15:0-3-0,0-3-4], [20:0-3-8,Edge], [27:0-3-0,0-3-0], [34:0-3-8,Edge]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.630.160.35
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
-0.16-0.220.02
(loc)
191920
l/defl
n/rn/rn/a
L/d
12090n/a
PLATES
MT20
Weight: 170 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2WEBS2 X 6 SPF 1650F 1.5E
OTHERS 2 X 4 SPF Stud *Except*
ST7,ST6: 2 X 4 SPF No.2
BRACING
TOP CHORD
Structural wood sheathing directly applied or 9-6-15 oc purlins, except end verticals.BOT CHORDRigid ceiling directly applied or 6-0-0 oc bracing.WEBS1 Row at midpt 10-27, 9-28, 11-26
REACTIONS All bearings 30-0-0.(lb) - Max Horz34=-450(LC 6)
Max Uplift
All uplift 100 lb or less at joint(s) 28, 29, 30, 31, 26, 25,
24, 23 except 34=-196(LC 6), 20=-187(LC 9), 32=-133(LC 8),
33=-164(LC 7), 22=-137(LC 9), 21=-133(LC 6)Max GravAll reactions 250 lb or less at joint(s) 33, 21 except 34=445(LC 2), 20=445(LC 3), 27=440(LC 1), 28=450(LC 2), 29=408(LC 2), 30=331(LC 2), 31=317(LC 1), 32=303(LC 2),
REACTIONSMax GravAll reactions 250 lb or less at joint(s) 33, 21 except
34=445(LC 2), 20=445(LC 3), 27=440(LC 1), 28=450(LC 2),
29=408(LC 2), 30=331(LC 2), 31=317(LC 1), 32=303(LC 2),
26=450(LC 3), 25=408(LC 3), 24=331(LC 3), 23=317(LC 1),
22=303(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD2-34=-388/179, 2-3=-360/247, 3-4=-263/216, 9-10=-3/303, 10-11=-3/303, 18-20=-388/186BOT CHORD33-34=-161/382, 32-33=-161/382, 31-32=-161/382, 30-31=-161/382, 29-30=-161/382, 28-29=-161/382, 27-28=-161/382, 26-27=-161/382, 25-26=-161/382,
24-25=-161/382, 23-24=-161/382, 22-23=-161/382,
21-22=-161/382, 20-21=-161/382
WEBS
10-27=-320/0, 9-28=-330/122, 8-29=-288/139, 11-26=-330/122, 12-25=-288/139
NOTES (16)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Corner(3) -2-3-2 to 0-8-14,Exterior(2) 0-8-14 to 12-0-0, Corner(3) 12-0-0 to 15-0-0, Exterior(2) 18-0-0 to 29-3-2zone; end vertical left and right exposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed towind (normal to the face), see Standard Industry Gable End Details as applicable, orconsult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);
Category II; Exp B; Partially Exp.; Ct=1.1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times
flat roof load of 38.5 psf on overhangs non-concurrent with other live loads.6) All plates are 1.5x4 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement(i.e. diagonal web).9) Gable studs spaced at 2-0-0 oc.10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrentwith any other live loads.11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members, with BCDL = 10.0psf.Continued on page 2
Job
QB1212002
Truss
T3DGE
Truss Type
COMMON TRUSS
Qty
2
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 11:00:53 2013 Page 2 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-ASEdIn0j7t8dunx7?I_Wyf70dxeacI8xlpVe23zLuRO
NOTES (16)
12) All bearings are assumed to be SPF No.2 .
13) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 100 lb uplift at joint(s) 28, 29, 30, 31, 26, 25, 24, 23 except (jt=lb) 34=196,20=187, 32=133, 33=164, 22=137, 21=133.14) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.15) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 16) All Plates 20 Gauge Unless Noted
LOAD CASE(S)
Standard
Job
QB1212002
Truss
V1
Truss Type
GABLE
Qty
1
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:41:51 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-clEvcHBO4?GguHde5SUjfqqwVbua2tDs98sDzFzLujE
Scale = 1:28.0
T1 T1
B1
ST1 ST1
1
2
3
4
5
7 6
8 9
10 11
12
13
14 153x4
3x4
3x4
1.5x4
1.5x4
1.5x4
1.5x4
13-9-0
13-9-0
6-10-8
6-10-8
13-9-0
6-10-8
4-7-08.00 12
Plate Offsets (X,Y): [3:0-2-0,Edge]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.270.150.11
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
n/an/a0.00
(loc)
- - 5
l/defl
n/an/an/a
L/d
999999n/a
PLATES
MT20
Weight: 39 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2OTHERS2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS All bearings 13-9-0.(lb) - Max Horz1=-176(LC 6)Max UpliftAll uplift 100 lb or less at joint(s) except 7=-237(LC 8), 6=-237(LC 9)Max Grav
All reactions 250 lb or less at joint(s) 1, 5 except
7=569(LC 2), 6=569(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS2-7=-438/287, 4-6=-438/287
NOTES (11)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) 0-5-12 to 3-5-12,Interior(1) 3-5-12 to 3-10-8, Exterior(2) 3-10-8 to 6-10-8, Interior(1) 9-10-8 to 10-3-4zone; end vertical left and right exposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with
any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 237 lb uplift at joint 7 and 237 lb uplift at joint 6.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss.
11) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard
Job
QB1212002
Truss
V2
Truss Type
Valley Truss
Qty
1
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:41:49 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-gM68BcA8YO0yezTF_1SFaPlXroCxaz1ZhqN6uNzLujG
Scale = 1:21.3
T1 T1
B1
ST1
1
2
3
4
5
6 7
8
2x4
4x4
2x4 1.5x4
9-9-0
9-9-0
4-10-8
4-10-8
9-9-0
4-10-8
3-3-08.00 12
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLLBCDL
38.5
10.00.0 *10.0
SPACING
Plates Increase
Lumber IncreaseRep Stress IncrCode
2-0-0
1.15
1.15YESIRC2009/TPI2007
CSI
TC
BCWB(Matrix)
0.53
0.160.09
DEFL
Vert(LL)
Vert(TL)Horz(TL)
in
n/a
n/a0.00
(loc)
-
- 3
l/defl
n/a
n/an/a
L/d
999
999n/a
PLATES
MT20
Weight: 26 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2OTHERS2 X 4 SPF StudBRACING
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1 =289/9-9-0 (min. 0-1-10)3 =289/9-9-0 (min. 0-1-10)4 =450/9-9-0 (min. 0-1-10)Max Horz1 =-121(LC 6)Max Uplift1 =-110(LC 8)
3 =-117(LC 9)
4 =-72(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS2-4=-340/136
NOTES (11)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;
enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent withany other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members.
7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 4 except (jt=lb) 1=110, 3=117.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted
LOAD CASE(S)
Standard
Job
QB1212002
Truss
V3
Truss Type
Valley Truss
Qty
1
Ply
1
CLOVERDALE EXT. NORTHAMPTON, MA
Job Reference (optional)7.250 s Jan 25 2012 MiTek Industries, Inc. Mon Apr 29 10:41:47 2013 Page 1 Truss Engineering Corp., Indian Orchard, MA 01151 ID:j_0BddqaqHpxSDbhuUjtn9y96zc-j__Omw8t0mmEPgKstcQnV_fHW_VC64yGEWu?qUzLujI
Scale = 1:13.9
T1 T1
B1
1
2
3
4
5
2x4
3x4
2x4
5-9-0
5-9-0
2-10-8
2-10-8
5-9-0
2-10-8
1-11-08.00 12
Plate Offsets (X,Y): [2:0-2-0,Edge]
LOADING (psf)TCLL(Ground Snow=50.0)TCDLBCLL
BCDL
38.5
10.00.0 *
10.0
SPACING
Plates IncreaseLumber IncreaseRep Stress IncrCode
2-0-0
1.151.15YESIRC2009/TPI2007
CSI
TCBCWB(Matrix)
0.140.240.00
DEFL
Vert(LL)Vert(TL)Horz(TL)
in
n/an/a0.00
(loc)
- - 3
l/defl
n/an/an/a
L/d
999999n/a
PLATES
MT20
Weight: 13 lb FT = 10%
GRIP
197/144
LUMBERTOP CHORD 2 X 4 SPF No.2BOT CHORD 2 X 4 SPF No.2BRACING
TOP CHORD
Structural wood sheathing directly applied or 5-9-0 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)1 =280/5-9-0 (min. 0-1-8)3 =280/5-9-0 (min. 0-1-8)Max Horz1 =-66(LC 6)Max Uplift1 =-87(LC 8)3 =-87(LC 8)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD
1-4=-261/111, 3-5=-261/111
NOTES (11)
1) Wind: ASCE 7-05; 120mph; TCDL=4.2psf; BCDL=5.0psf; h=25ft; Cat. II; Exp B;enclosed; MWFRS (low-rise) automatic zone and C-C Exterior(2) zone; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.33 plate grip DOL=1.332) TCLL: ASCE 7-05; Pg= 50.0 psf (ground snow); Pf=38.5 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with
any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all
areas where a rectangle 3-6-0 tall by 1-0-0 wide will fit between the bottom chord and
any other members.7) All bearings are assumed to be SPF No.2 . 8) Provide mechanical connection (by others) of truss to bearing plate capable ofwithstanding 100 lb uplift at joint(s) 1, 3.9) This truss is designed in accordance with the 2009 International Residential Codesections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks with fixed heels" Member end fixity model was used in theanalysis and design of this truss. 11) All Plates 20 Gauge Unless Noted
LOAD CASE(S)Standard