32C-107 32 Smith St ZPA 2015-09-21---
---
File # MP-2016-0016
APPLICANT/CONTACT PERSON Berkshire Design Group
ADDRESSIPHONE 4 Allen Place (413) 582-7000
PROPERTY LOCATION 32 SMITH ST
MAP 32C PARCEL 107 001 ZONE URC(58)1WP(56)/SI(46)INB(O)/
TIDS SECTION FOR OFFICIAL USE ONLY:
PERMIT APPLICATION CHECKLIST
ENCLOSED REQUIRED DATE
ZONING FORM FILLED OUT
Fee Paid
Building Permit Filled out
Fee Paid
TypeofConstruction: ZPA -5600 SO FT BUILDING ADDITION
New Construction
Non Structural interior renovations
Adgition to Existing
Accessory Structure
Building Plans Included:
Ownerl Statement or License
3 sets ofPlans / Plot Plan
THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
INFORMATION P~ENTED:
__Approved ~Additional permits required (see below)
PLANNING BOARD PERMIT REQUIRED UNDER: § JSo - ,f
Intermediate Project: ~AND/OR,--__S.pecial Permit with Site Plan
Major Project: V~AND/OR Special Permit with Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: ~__________
Finding_____ Special Permit _____ Variance* ______
__---'Received & Recorded at Registry ofDeeds ProofEnclosed__~__
___Other Permits Required:
Curb Cut from DPW ___Water Availability ___Sewer Availability
___Septic Approval Board ofHealth ____Well Water Potability Board ofHealth
~permit from Conservation Commission Permit from CB Architecture Committee
__-,Permit from Elm Street Commission ____Permit DPW Storm Water Management
Signature 0 Ulldmg OffiCIal Date '
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health, Conservation Commission, Department
of public works and other applicable permit granting authorities.
*Variances are granted only to those applicants who meet the strict standards ofMGL 40A. Contact the Office of
Planning & Development for more information.
SEP I 62015 I~
Please type or print all information and return this form to the Building
Inspector's Office with the $30filingfee (check or money order) payable to the
City ofNorthampton
1. Name of Applicant: Berkshire Design Group on behalf of Smith Street Associates, LLC
Address:____4_A_I_le_n_P_la_c_e_____~____Telephone:--(.>-4..;;;;.1-'-'3)'--'5:;....;8;..;;;2;....;-7..;;;;.00:...:....:;.0____
2. Owner of Property: Smith Street Associates, LLC
Address:____ 3...,;2_S_m..;;;;.i...,;th...,;...,;St_re_e_t_________Telephone:-__(L-.4=13"-'-)--"5_8""-6-...;;.3=53.;;;...;5'--___
3. Status of Applicant: Owner --<.;X~_ Contract Purchaser ___ Lessee___ Other (explain) _____
Job Location: ___32_Sm_it_h_S_tr_e_e_t________________________4.
5. Existing Use of Structure/Property: Commercial/Industrial (steel fabrication)
6. Description of Proposed Use/Work/ProjectlOccupation: (Use additional sheets if necessary):
Project proposes the construction of a 5600 SF building addition and site work necessary to
comply with Conservation Commission/DEP requirements.
7. Attached Plans: Sketch Plan Site Plan x Engineered/Surveyed Plans _<.>.X__
8. Has a Special PermitlVariance/Finding ever been issued for/on the site?
NO ____ DONT KNOW __X__ YES ____ IF YES, date issued:________
IF YES: Was the permit recorded at the Registry of Deeds?
NO ____ DONT KNOW _X___ YES ____
IF YES: enter Book _____ Page _____ and/or Document#_'_"'--____
9.Does the site contain a brook, body of water or wetlands? NO ___ DONT KNOW ___ YES ~X,,--_
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained _-"X~__ Obtained _____, date issued:
(Form Continues On Other Side)
W:\Documents\FORMS\original\Building-Inspector\Zoning-Permit-Application-passive.doc 8/412004
10. Do any signs exist on the property? YES ____ NO ----'X...O--__
IF YES, describe size, type and location:________________________
Are there any proposed changes to or additions of signs intended for the property? YES ___N,O X
IF YES, describe size, type and location:_________________________
11. Will the construction activity disturb (clearing, grading, excavation, or filling) over 1 acre or is it part of a common
plan of development that wiLL disturb over 1 acre? YES NO _X_
IF YES, then a Northampton Storm Water Management Permit from the DPW is required.
12. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION
This column reserved
for use by the Building
D'epart:ment,-...EXISTING PROPOSED REQUIRED BY
ZONING
Lot Size
2.4 acres unchan..Red
Frontage
30' unchanged
Setbacks Front
97' 97'
Side L: R:L: 191' R: 0' L: 140' R: 0'
Rear 21' 21'
Building Height 40' unchanged
Building Square Footage
12,033 SF
17,633 SF
%Open Space: (lot area
minus building a: paved
87.5% 82.2% parking
# of Parking Spaces
12+/unchanged
# of Loading Docks
2
3
Fill:
(volume a: location)
unchanged0
13. Certification: I hereby certify that the information contained herein is true and accurate to the best of
my knowledge.
""te: Applicant's S'lIl'ture .,clIf{PIrS
NOTE-:::Ia:ce ofa zoningpennit does not relieveap .can, s burden t complywith all zoning
requirements and obtain all required pennits from the Board ofHealth, Conservation Commission,
Historic andArchitectural Boards, Department ofPublic Works and other applicable permit granting
authorities.
W:\Documents\FORMS\origina1\BuiJding-Inspector\Zouing-Permit-Application-passive.doc 8/4/2004