Loading...
17D-073 30 High St 2018-10-05PRELIMNARY NOT FOR CONSTRUCTION A-03213 SCOPE OF WORKDIVISIONS 2 - 5: SITE WORK, CONCRETE, MASONRY, METALS1.NONEDIVISION 6: WOOD & PLASTICS1.2x4 KD SPRUCE INTERIOR WALL STUDS @ 16" O.C. TO FRAME SHOWER NICHE2.2x6 EXTERIOR STUDS TO FRAME IN WINDOW OPENING; EXISTING HEADER ISASSUMED TO REMAIN3.PATCH SHEATHING IN EXISTING WINDOW OPENING4.INSTALL BLOCKING FOR BATHROOM ACCESSORIES / TOWEL BARS DURINGDEMO AND FRAMING PRIOR TO NEW DRYWALL WORK5.INSTALL CONCRETE BACKER BOARD TO NEW SHOWER WALLS6.IT IS ASSUMED THAT EXISTING WINDOW ROUGH OPENING IS LEVEL, PLUMB,SQUARE, AND FREE OF ROT FOR NEW WINDOWS TO BE INSTALLED7.ASSESS CONDITION OF SUBFLOOR AND UNDERLAYMENT. CURRENTLYASSUMED TO BE ADEQUATE FOR TILE FLOORING. IF FOUND TO BE ROTTEN,DAMAGED, OR OTHERWISE DEFICIENT, CONTRACTOR TO REVIEW OPTIONSAND PRICING WITH OWNER.NEW WALL FLUSHWITH EXISTING HERE WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL= DEMO 2x4 HALF WALLTO FINISHTO FINISHSCOPE OF WORKDIVISION 7: THERMAL & MOISTURE PROTECTION1.SUPPLY & INSTALL 5/4" X 4" PRIMED PINE FOR EXTERIOR WINDOW TRIM TO MATCH EXISTINGWINDOWS2.SUPPLY & INSTALL PRIMED PINE EXTERIOR WINDOW SILL TO MATCH EXISTING WINDOWS3.SUPPLY & INSTALL PRIMED WOOD LAP SIDING "WOVEN" INTO EXISTING SIDING4.SUPPLY & INSTALL SPRAY FOAM AT WINDOW FRAMING GAPSDIVISION 8: DOORS & WINDOWS1.SUPPLY & INSTALL (1) MATHEWS BROTHERS VINYL WINDOW PER PLAN AND SCHEDULEDIVISION 9: FINISHES1.SUPPLY & INSTALL NEW TILE FLOORING, SHOWER BASE, THRESHOLD, SHOWER SHELVES, ANDSHOWER WALL TILE PER SCHEDULE 2 ON A-032.TILE SELECTIONS ARE BASED ON ARROW TILE'S QUOTE WHICH DOES NOT IDENTIFY INDIVIDUALTILES. IT IS OWNER'S RESPONSIBILITY TO CONFIRM TILE MATCHES THEIR CHOICES.3.CURRENT TILE PACKAGE ALSO INCLUDES ITEMS OWNER INTENDS TO CHANGE: CARRARRATHRESHOLD AND NICHE SHELVES AND TILE. PRICE OF ENTIRE TILE PACKAGE WILL BE ADJUSTEDONCE THESE FINAL SELECTIONS ARE MADE AND OWNER WILL BE ABLE TO REVIEW / APPROVEDIFFERENCE IN COST PRIOR TO CONTRACTOR ORDERING TILE, THRESHOLD, AND SHELVES4.SUPPLY & INSTALL NEW BASEBOARDS PER SCHEDULE 2 ON A-035.SUPPLY & INSTALL PVC EXTENSION JAMBS TO WINDOW; NO INTERIOR WINDOW CASING ISINCLUDEDDIVISION 10: SPECIALTIES1.SUPPLY & INSTALL NEW SHOWER GLASS BY ALLOWANCEDIVISION 11: EQUIPMENT1.NONEDIVISION 12: FURNISHINGS1.SUPPLY & INSTALL VANITY, BACKSPLASH, AND COUNTERTOP PER SCHEDULE 1 ON A-042.SUPPLY & INSTALL NEW MEDICINE CABINET PER SCHEDULE 1 ON A-043.SUPPLY & INSTALL BATH ACCESSORIES PER SCHEDULE 1 ON A-04DIVISION 13: SPECIAL CONSTRUCTION1.NONEDIVISION 14: CONVEYING SYSTEMS1.NONEDIVISION 15: MECHANICAL1.ROUGH IN FIXTURES IN NEW LOCATIONS2.SUPPLY & INSTALL SCHLUTER SHOWER PAN WITH CENTER DRAIN3.SUPPLY & INSTALL KERDI WATERPROOFING TO SHOWER WALLS AND FLOOR4.SUPPLY & INSTALL SHOWER HEAD, CONTROLS, AND DRAIN IN NEW LOCATIONS PER SCHEDULE 1ON A-045.SUPPLY & INSTALL SINK AND FAUCET IN NEW LOCATION PER SCHEDULE 1 ON A-046.REINSTALL SAVED TOILET AND SEAT IN NEW LOCATION7.CONNECT VENT PIPING TO EXISTING VENT (ASSUMED TO BE IN CORNER, BEHIND EXISTINGTOILET8.EXISTING HEAT TO REMAIN AND WILL BE UNDERNEATH VANITY SPECIFICATIONS DIVISION 1 – GENERAL REQUIREMENTS: 1.CONTRACTOR WILL OBTAIN ALL NECESSARY PERMITS FOR CONSTRUCTION, EXCEPT THAT OWNER SHALL BE RESPONSIBLE FOR WATER, SEWER, ELECTRIC, AND CABLE FEES, IF ANY. 2.CONTRACT EXCLUDES APPROVALS BY ZONING BOARD OF APPEALS, PLANNING BOARD AND/OR CONSERVATION COMMISSION. 3.CONTRACT EXCLUDES ARCHITECTURAL OVERSIGHT. 4.ANY OTHER REQUIREMENTS FROM TOWN NOT EXPLICITLY INCLUDED IN THE PLANS OR SPECS ARE NOT INCLUDED IN THIS CONTRACT. 5.SITE SURVEY IS NOT INCLUDED. 6.CONTRACTOR HAS NOT TESTED FOR ASBESTOS, LEAD PAINT, RADON, AND OTHER HAZARDOUS MATERIALS AND CONTRACT DOES NOT INCLUDE ANY REMEDIATION OR ABATEMENT WORK. 7.ALL OWNER-SUPPLIED ITEMS ARE NOT UNDER WARRANTY BY INTEGRITY OR INTEGRITY’S SUB- CONTRACTORS AND SUPPLIERS. ANY OWNER-SUPPLIED ITEMS THAT ARRIVE DAMAGED, LATE OR INCOMPLETE MAY CAUSE DELAYS TO THE SCHEDULE AND INTEGRITY WILL NOT BE HELD LIABLE FOR SUCH DELAYS. 8.CONTRACT INCLUDES ON-SITE AND IN-OFFICE JOB COORDINATION 9.REQUIRED INSURANCES INCLUDE GENERAL LIABILITY INSURANCE AND WORKER'S COMPENSATION INSURANCE 10.CONTRACTOR TO SUPPLY TEMPORARY SANI-CAN ON SITE 11.ALL CONSTRUCTION DEBRIS WILL BE PLACED IN AN ONSITE DUMPSTER PROVIDED BY CONTRACTOR AND REMOVED BY CONTRACTOR AT CONTRACTOR’S EXPENSE. 12.ALL UTILITIES USED DURING CONSTRUCTION ARE THE OWNER’S RESPONSIBILITY. 13.CONTRACTOR SHALL PROMPTLY REMOVE ALL CONSTRUCTION EQUIPMENT AND MATERIALS FROM SITE AT CONCLUSION OF CONSTRUCTION. 14.WHEREVER CONTRACTOR DRAWING OR SPECIFICATION STATES, “MATCH EXISTING,” SUCH LANGUAGE SHALL MEAN “MATCH EXISTING AS CLOSELY AS POSSIBLE FROM CURRENTLY AVAILABLE STOCK ITEMS PURCHASED LOCALLY”. 15.ALL DIMENSIONS ARE FRAMING TO FRAMING UNLESS OTHERWISE SPECIFIED. 16.ALL EXISTING STRUCTURAL COMPONENTS TO REMAIN UNLESS OTHERWISE SPECIFIED. 17. APPLIANCES, FURNITURE, ETC. SHOWN ON PLANS ARE TO BE SUPPLIED BY OWNER. 18.ROOM FINISHES PER FINISH SCHEDULE. TOILET DRAWN AT 29 3/4" DEEP. SHOWERGLASS DIMENSIONS TBD PER ACTUAL TOILETDIMENSIONS. EXISTING TOILET MAY VARY.REMOVE & DISCARDTO REMAIN4'-9 1/2" 1'-2" 1'-0 1/2" 7'-8 1/2"6 3/4"8 1/4"5'-1 1/2"DEMO. SCOPE OF WORK 1.EXISTING DOOR, CASING, AND HARDWARE TO REMAIN; NO WORK HAS BEEN INCLUDED FOR THIS DOOR 2.REMOVE & DISCARD (1) WINDOW 3.REMOVE & DISCARD DRYWALL AS NECESSARY FOR ELECTRICAL AND PLUMBING WORK 4.REMOVE & DISCARD TILE FLOORING AND ALL WALL TILE 5.REMOVE & DISCARD CLAWFOOT TUB AND CONTROL, PEDESTAL SINK, AND FAUCET 6.REMOVE & SAVE TOILET AND TOILET SEAT 7.REMOVE & DISCARD ALL BATHROOM ACCESSORIES 8.ASSESS ACCESS FOR PLUMBING LOCATION CHANGES. IF KITCHEN CEILING BELOW NEEDS TO BE OPENED FOR THIS WORK, REVIEW COST AND TIMING WITH OWNER. 9.EXISTING HEAT TO REMAIN IN BATHROOM WALL KEY = EXISTING 2x4 INTERIOR WALL = EXISTING 2x6 EXTERIOR WALL = EXISTING 2x4 HALF WALL = DEMO. 2x4 INTERIOR WALL = DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALL BATH DEMO. SCOPE OF WORK 1.EXISTING DOOR, CASING, AND HARDWARE TO REMAIN; NO WORK HAS BEEN INCLUDED FOR THIS DOOR 2.REMOVE & DISCARD (1) WINDOW 3.REMOVE & DISCARD DRYWALL AS NECESSARY FOR ELECTRICAL AND PLUMBING WORK 4.REMOVE & DISCARD TILE FLOORING AND ALL WALL TILE 5.REMOVE & DISCARD CLAWFOOT TUB AND CONTROL, PEDESTAL SINK, AND FAUCET 6.REMOVE & SAVE TOILET AND TOILET SEAT 7.REMOVE & DISCARD ALL BATHROOM ACCESSORIES 8.ASSESS ACCESS FOR PLUMBING LOCATION CHANGES. IF KITCHEN CEILING BELOW NEEDS TO BE OPENED FOR THIS WORK, REVIEW COST AND TIMING WITH OWNER. 9.EXISTING HEAT TO REMAIN IN BATHROOM WALL KEY= EXISTING 2x4 INTERIOR WALL = EXISTING 2x6 EXTERIOR WALL = EXISTING 2x4 HALF WALL = DEMO. 2x4 INTERIOR WALL = DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALL Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 FAX: 413-549-7918 EMAIL: INFO@INTEGBUILD.COMDESIGN BY HFWHEAT RESIDENCECONTRACT AGREED BY: ____________________________________________________________________________ DOUGLAS WHEAT - OWNER OF 30 HIGH STREET, FLORENCE, MA 01002 ____________________________________________________________________________ AMY SELDIN - OWNER OF 30 HIGH STREET, FLORENCE, MA 01002 ____________________________________________________________________________ OWNER FOR INTEGRITY DEVELOPMENT & CONSTRUCTION, INC.INTEGRITY1A- DATE: 10/19/2018PRELIMINARYNOT FORCONSTRUCTION30 HIGH STREET, FLORENCE, MA 01062BATH REMODELBATH REMODEL 30 HIGH STREET, FLORENCE, MA 01062 WHEAT RESIDENCE SHEET: 1 A-01 1 A-01 EXISTING FLOOR PLAN 1/2" = 1'-0" PRELIMNARY NOT FOR CONSTRUCTION CENTER IN EXISTING OPENINGTO REMAINA-03 2 1 31"2'-6"1'-9"1'-4 1/2"2'-7 1/4"1'-3"2'-5 3/4"6 3/4"6"2'1'-10"1'-6"1'-6 1/2" SCOPE OF WORK DIVISIONS 2 - 5: SITE WORK, CONCRETE, MASONRY, METALS 1.NONE DIVISION 6: WOOD & PLASTICS 1.2x4 KD SPRUCE INTERIOR WALL STUDS @ 16" O.C. TO FRAME SHOWER NICHE 2.2x6 EXTERIOR STUDS TO FRAME IN WINDOW OPENING; EXISTING HEADER IS ASSUMED TO REMAIN 3.PATCH SHEATHING IN EXISTING WINDOW OPENING 4.INSTALL BLOCKING FOR BATHROOM ACCESSORIES / TOWEL BARS DURING DEMO AND FRAMING PRIOR TO NEW DRYWALL WORK 5.INSTALL CONCRETE BACKER BOARD TO NEW SHOWER WALLS 6.IT IS ASSUMED THAT EXISTING WINDOW ROUGH OPENING IS LEVEL, PLUMB, SQUARE, AND FREE OF ROT FOR NEW WINDOWS TO BE INSTALLED 7.ASSESS CONDITION OF SUBFLOOR AND UNDERLAYMENT. CURRENTLY ASSUMED TO BE ADEQUATE FOR TILE FLOORING. IF FOUND TO BE ROTTEN, DAMAGED, OR OTHERWISE DEFICIENT, CONTRACTOR TO REVIEW OPTIONS AND PRICING WITH OWNER. NEW WALL FLUSH WITH EXISTING HERE WALL KEY = EXISTING 2x4 INTERIOR WALL = EXISTING 2x6 EXTERIOR WALL = EXISTING 2x4 HALF WALL = DEMO. 2x4 INTERIOR WALL = DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALL BATH TO FINISHTO FINISHSCOPE OF WORK DIVISION 7: THERMAL & MOISTURE PROTECTION 1.SUPPLY & INSTALL 5/4" X 4" PRIMED PINE FOR EXTERIOR WINDOW TRIM TO MATCH EXISTING WINDOWS 2.SUPPLY & INSTALL PRIMED PINE EXTERIOR WINDOW SILL TO MATCH EXISTING WINDOWS 3.SUPPLY & INSTALL PRIMED WOOD LAP SIDING "WOVEN" INTO EXISTING SIDING 4.SUPPLY & INSTALL SPRAY FOAM AT WINDOW FRAMING GAPS DIVISION 8: DOORS & WINDOWS 1.SUPPLY & INSTALL (1) MATHEWS BROTHERS VINYL WINDOW PER PLAN AND SCHEDULE DIVISION 9: FINISHES 1.SUPPLY & INSTALL NEW TILE FLOORING, SHOWER BASE, THRESHOLD, SHOWER SHELVES, AND SHOWER WALL TILE PER SCHEDULE 2 ON A-03 2.TILE SELECTIONS ARE BASED ON ARROW TILE'S QUOTE WHICH DOES NOT IDENTIFY INDIVIDUAL TILES. IT IS OWNER'S RESPONSIBILITY TO CONFIRM TILE MATCHES THEIR CHOICES. 3.CURRENT TILE PACKAGE ALSO INCLUDES ITEMS OWNER INTENDS TO CHANGE: CARRARRA THRESHOLD AND NICHE SHELVES AND TILE. PRICE OF ENTIRE TILE PACKAGE WILL BE ADJUSTED ONCE THESE FINAL SELECTIONS ARE MADE AND OWNER WILL BE ABLE TO REVIEW / APPROVE DIFFERENCE IN COST PRIOR TO CONTRACTOR ORDERING TILE, THRESHOLD, AND SHELVES 4.SUPPLY & INSTALL NEW BASEBOARDS PER SCHEDULE 2 ON A-03 5.SUPPLY & INSTALL PVC EXTENSION JAMBS TO WINDOW; NO INTERIOR WINDOW CASING IS INCLUDED DIVISION 10: SPECIALTIES 1.SUPPLY & INSTALL NEW SHOWER GLASS BY ALLOWANCE DIVISION 11: EQUIPMENT 1.NONE DIVISION 12: FURNISHINGS 1.SUPPLY & INSTALL VANITY, BACKSPLASH, AND COUNTERTOP PER SCHEDULE 1 ON A-04 2.SUPPLY & INSTALL NEW MEDICINE CABINET PER SCHEDULE 1 ON A-04 3.SUPPLY & INSTALL BATH ACCESSORIES PER SCHEDULE 1 ON A-04 DIVISION 13: SPECIAL CONSTRUCTION 1.NONE DIVISION 14: CONVEYING SYSTEMS 1.NONE DIVISION 15: MECHANICAL 1.ROUGH IN FIXTURES IN NEW LOCATIONS 2.SUPPLY & INSTALL SCHLUTER SHOWER PAN WITH CENTER DRAIN 3.SUPPLY & INSTALL KERDI WATERPROOFING TO SHOWER WALLS AND FLOOR 4.SUPPLY & INSTALL SHOWER HEAD, CONTROLS, AND DRAIN IN NEW LOCATIONS PER SCHEDULE 1 ON A-04 5.SUPPLY & INSTALL SINK AND FAUCET IN NEW LOCATION PER SCHEDULE 1 ON A-04 6.REINSTALL SAVED TOILET AND SEAT IN NEW LOCATION 7.CONNECT VENT PIPING TO EXISTING VENT (ASSUMED TO BE IN CORNER, BEHIND EXISTING TOILET 8.EXISTING HEAT TO REMAIN AND WILL BE UNDERNEATH VANITY SPECIFICATIONS DIVISION 1 – GENERAL REQUIREMENTS: 1.CONTRACTOR WILL OBTAIN ALL NECESSARY PERMITS FOR CONSTRUCTION, EXCEPT THAT OWNER SHALL BE RESPONSIBLE FOR WATER, SEWER, ELECTRIC, AND CABLE FEES, IF ANY. 2.CONTRACT EXCLUDES APPROVALS BY ZONING BOARD OF APPEALS, PLANNING BOARD AND/OR CONSERVATION COMMISSION. 3.CONTRACT EXCLUDES ARCHITECTURAL OVERSIGHT. 4.ANY OTHER REQUIREMENTS FROM TOWN NOT EXPLICITLY INCLUDED IN THE PLANS OR SPECS ARE NOT INCLUDED IN THIS CONTRACT. 5.SITE SURVEY IS NOT INCLUDED. 6.CONTRACTOR HAS NOT TESTED FOR ASBESTOS, LEAD PAINT, RADON, AND OTHER HAZARDOUS MATERIALS AND CONTRACT DOES NOT INCLUDE ANY REMEDIATION OR ABATEMENT WORK. 7.ALL OWNER-SUPPLIED ITEMS ARE NOT UNDER WARRANTY BY INTEGRITY OR INTEGRITY’S SUB- CONTRACTORS AND SUPPLIERS. ANY OWNER-SUPPLIED ITEMS THAT ARRIVE DAMAGED, LATE OR INCOMPLETE MAY CAUSE DELAYS TO THE SCHEDULE AND INTEGRITY WILL NOT BE HELD LIABLE FOR SUCH DELAYS. 8.CONTRACT INCLUDES ON-SITE AND IN-OFFICE JOB COORDINATION 9.REQUIRED INSURANCES INCLUDE GENERAL LIABILITY INSURANCE AND WORKER'S COMPENSATION INSURANCE 10.CONTRACTOR TO SUPPLY TEMPORARY SANI-CAN ON SITE 11.ALL CONSTRUCTION DEBRIS WILL BE PLACED IN AN ONSITE DUMPSTER PROVIDED BY CONTRACTOR AND REMOVED BY CONTRACTOR AT CONTRACTOR’S EXPENSE. 12.ALL UTILITIES USED DURING CONSTRUCTION ARE THE OWNER’S RESPONSIBILITY. 13.CONTRACTOR SHALL PROMPTLY REMOVE ALL CONSTRUCTION EQUIPMENT AND MATERIALS FROM SITE AT CONCLUSION OF CONSTRUCTION. 14.WHEREVER CONTRACTOR DRAWING OR SPECIFICATION STATES, “MATCH EXISTING,” SUCH LANGUAGE SHALL MEAN “MATCH EXISTING AS CLOSELY AS POSSIBLE FROM CURRENTLY AVAILABLE STOCK ITEMS PURCHASED LOCALLY”. 15.ALL DIMENSIONS ARE FRAMING TO FRAMING UNLESS OTHERWISE SPECIFIED. 16.ALL EXISTING STRUCTURAL COMPONENTS TO REMAIN UNLESS OTHERWISE SPECIFIED. 17. APPLIANCES, FURNITURE, ETC. SHOWN ON PLANS ARE TO BE SUPPLIED BY OWNER. 18.ROOM FINISHES PER FINISH SCHEDULE. TOILET DRAWN AT 29 3/4" DEEP. SHOWER GLASS DIMENSIONS TBD PER ACTUAL TOILET DIMENSIONS. EXISTING TOILET MAY VARY. A-03213 SCOPE OF WORK DIVISIONS 2 - 5: SITE WORK, CONCRETE, MASONRY, METALS 1.NONE DIVISION 6: WOOD & PLASTICS 1.2x4 KD SPRUCE INTERIOR WALL STUDS @ 16" O.C. TO FRAME SHOWER NICHE 2.2x6 EXTERIOR STUDS TO FRAME IN WINDOW OPENING; EXISTING HEADER IS ASSUMED TO REMAIN 3.PATCH SHEATHING IN EXISTING WINDOW OPENING 4.INSTALL BLOCKING FOR BATHROOM ACCESSORIES / TOWEL BARS DURING DEMO AND FRAMING PRIOR TO NEW DRYWALL WORK 5.INSTALL CONCRETE BACKER BOARD TO NEW SHOWER WALLS 6.IT IS ASSUMED THAT EXISTING WINDOW ROUGH OPENING IS LEVEL, PLUMB, SQUARE, AND FREE OF ROT FOR NEW WINDOWS TO BE INSTALLED 7.ASSESS CONDITION OF SUBFLOOR AND UNDERLAYMENT. CURRENTLY ASSUMED TO BE ADEQUATE FOR TILE FLOORING. IF FOUND TO BE ROTTEN, DAMAGED, OR OTHERWISE DEFICIENT, CONTRACTOR TO REVIEW OPTIONS AND PRICING WITH OWNER. NEW WALL FLUSH WITH EXISTING HERE WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL = DEMO 2x4 HALF WALLTO FINISHTO FINISHSCOPE OF WORK DIVISION 7: THERMAL & MOISTURE PROTECTION 1.SUPPLY & INSTALL 5/4" X 4" PRIMED PINE FOR EXTERIOR WINDOW TRIM TO MATCH EXISTING WINDOWS 2.SUPPLY & INSTALL PRIMED PINE EXTERIOR WINDOW SILL TO MATCH EXISTING WINDOWS 3.SUPPLY & INSTALL PRIMED WOOD LAP SIDING "WOVEN" INTO EXISTING SIDING 4.SUPPLY & INSTALL SPRAY FOAM AT WINDOW FRAMING GAPS DIVISION 8: DOORS & WINDOWS 1.SUPPLY & INSTALL (1) MATHEWS BROTHERS VINYL WINDOW PER PLAN AND SCHEDULE DIVISION 9: FINISHES 1.SUPPLY & INSTALL NEW TILE FLOORING, SHOWER BASE, THRESHOLD, SHOWER SHELVES, AND SHOWER WALL TILE PER SCHEDULE 2 ON A-03 2.TILE SELECTIONS ARE BASED ON ARROW TILE'S QUOTE WHICH DOES NOT IDENTIFY INDIVIDUAL TILES. IT IS OWNER'S RESPONSIBILITY TO CONFIRM TILE MATCHES THEIR CHOICES. 3.CURRENT TILE PACKAGE ALSO INCLUDES ITEMS OWNER INTENDS TO CHANGE: CARRARRA THRESHOLD AND NICHE SHELVES AND TILE. PRICE OF ENTIRE TILE PACKAGE WILL BE ADJUSTED ONCE THESE FINAL SELECTIONS ARE MADE AND OWNER WILL BE ABLE TO REVIEW / APPROVE DIFFERENCE IN COST PRIOR TO CONTRACTOR ORDERING TILE, THRESHOLD, AND SHELVES 4.SUPPLY & INSTALL NEW BASEBOARDS PER SCHEDULE 2 ON A-03 5.SUPPLY & INSTALL PVC EXTENSION JAMBS TO WINDOW; NO INTERIOR WINDOW CASING IS INCLUDED DIVISION 10: SPECIALTIES 1.SUPPLY & INSTALL NEW SHOWER GLASS BY ALLOWANCE DIVISION 11: EQUIPMENT 1.NONE DIVISION 12: FURNISHINGS 1.SUPPLY & INSTALL VANITY, BACKSPLASH, AND COUNTERTOP PER SCHEDULE 1 ON A-04 2.SUPPLY & INSTALL NEW MEDICINE CABINET PER SCHEDULE 1 ON A-04 3.SUPPLY & INSTALL BATH ACCESSORIES PER SCHEDULE 1 ON A-04 DIVISION 13: SPECIAL CONSTRUCTION 1.NONE DIVISION 14: CONVEYING SYSTEMS 1.NONE DIVISION 15: MECHANICAL 1.ROUGH IN FIXTURES IN NEW LOCATIONS 2.SUPPLY & INSTALL SCHLUTER SHOWER PAN WITH CENTER DRAIN 3.SUPPLY & INSTALL KERDI WATERPROOFING TO SHOWER WALLS AND FLOOR 4.SUPPLY & INSTALL SHOWER HEAD, CONTROLS, AND DRAIN IN NEW LOCATIONS PER SCHEDULE 1 ON A-04 5.SUPPLY & INSTALL SINK AND FAUCET IN NEW LOCATION PER SCHEDULE 1 ON A-04 6.REINSTALL SAVED TOILET AND SEAT IN NEW LOCATION 7.CONNECT VENT PIPING TO EXISTING VENT (ASSUMED TO BE IN CORNER, BEHIND EXISTING TOILET 8.EXISTING HEAT TO REMAIN AND WILL BE UNDERNEATH VANITY SPECIFICATIONS DIVISION 1 – GENERAL REQUIREMENTS: 1.CONTRACTOR WILL OBTAIN ALL NECESSARY PERMITS FOR CONSTRUCTION, EXCEPT THAT OWNER SHALL BE RESPONSIBLE FOR WATER, SEWER, ELECTRIC, AND CABLE FEES, IF ANY. 2.CONTRACT EXCLUDES APPROVALS BY ZONING BOARD OF APPEALS, PLANNING BOARD AND/OR CONSERVATION COMMISSION. 3.CONTRACT EXCLUDES ARCHITECTURAL OVERSIGHT. 4.ANY OTHER REQUIREMENTS FROM TOWN NOT EXPLICITLY INCLUDED IN THE PLANS OR SPECS ARE NOT INCLUDED IN THIS CONTRACT. 5.SITE SURVEY IS NOT INCLUDED. 6.CONTRACTOR HAS NOT TESTED FOR ASBESTOS, LEAD PAINT, RADON, AND OTHER HAZARDOUS MATERIALS AND CONTRACT DOES NOT INCLUDE ANY REMEDIATION OR ABATEMENT WORK. 7.ALL OWNER-SUPPLIED ITEMS ARE NOT UNDER WARRANTY BY INTEGRITY OR INTEGRITY’S SUB- CONTRACTORS AND SUPPLIERS. ANY OWNER-SUPPLIED ITEMS THAT ARRIVE DAMAGED, LATE OR INCOMPLETE MAY CAUSE DELAYS TO THE SCHEDULE AND INTEGRITY WILL NOT BE HELD LIABLE FOR SUCH DELAYS. 8.CONTRACT INCLUDES ON-SITE AND IN-OFFICE JOB COORDINATION 9.REQUIRED INSURANCES INCLUDE GENERAL LIABILITY INSURANCE AND WORKER'S COMPENSATION INSURANCE 10.CONTRACTOR TO SUPPLY TEMPORARY SANI-CAN ON SITE 11.ALL CONSTRUCTION DEBRIS WILL BE PLACED IN AN ONSITE DUMPSTER PROVIDED BY CONTRACTOR AND REMOVED BY CONTRACTOR AT CONTRACTOR’S EXPENSE. 12.ALL UTILITIES USED DURING CONSTRUCTION ARE THE OWNER’S RESPONSIBILITY. 13.CONTRACTOR SHALL PROMPTLY REMOVE ALL CONSTRUCTION EQUIPMENT AND MATERIALS FROM SITE AT CONCLUSION OF CONSTRUCTION. 14.WHEREVER CONTRACTOR DRAWING OR SPECIFICATION STATES, “MATCH EXISTING,” SUCH LANGUAGE SHALL MEAN “MATCH EXISTING AS CLOSELY AS POSSIBLE FROM CURRENTLY AVAILABLE STOCK ITEMS PURCHASED LOCALLY”. 15.ALL DIMENSIONS ARE FRAMING TO FRAMING UNLESS OTHERWISE SPECIFIED. 16.ALL EXISTING STRUCTURAL COMPONENTS TO REMAIN UNLESS OTHERWISE SPECIFIED. 17. APPLIANCES, FURNITURE, ETC. SHOWN ON PLANS ARE TO BE SUPPLIED BY OWNER. 18.ROOM FINISHES PER FINISH SCHEDULE. TOILET DRAWN AT 29 3/4" DEEP. SHOWER GLASS DIMENSIONS TBD PER ACTUAL TOILET DIMENSIONS. EXISTING TOILET MAY VARY.Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 FAX: 413-549-7918 EMAIL: INFO@INTEGBUILD.COMDESIGN BY HFWHEAT RESIDENCEINTEGRITY2A- DATE: 10/19/2018PRELIMINARYNOT FORCONSTRUCTION30 HIGH STREET, FLORENCE, MA 01062BATH REMODELPROPOSED FLOOR PLAN 1/2" = 1'-0" SHEET: 1 A-02 1 A-02 PRELIMNARY NOT FOR CONSTRUCTION 1'-6 1/2"7'-6 1/2"4"MATTE OFF- WHITE 3x6 SUBWAY TILE MATTE OFF- WHITE 3x6 SUBWAY TILE APPROX. 3" GLASS / SLATE MOSAIC STRIPE 10 1/2"1'-3"10 1/2" 3'1'1'1'2'-2"4"6 1/2" 1'-8" 1'-4 1/2"2'-7 1/4"1'-3"7'-6 1/2"4"3' MATTE OFF- WHITE 3x6 SUBWAY TILE BULLNOSE TILE MEDICINE CABINET BY ALLOWANCE CENTER IN EXISTING OPENING 4'-5 1/4"8 1/4" BULLNOSE TILE AROUND WINDOW APPROX. 3" GLASS / SLATE MOSAIC STRIPE MATTE OFF- WHITE 3x6 SUBWAY TILE CENTER IN EXISTING OPENING A-03213 SCOPE OF WORK DIVISIONS 2 - 5: SITE WORK, CONCRETE, MASONRY, METALS 1.NONE DIVISION 6: WOOD & PLASTICS 1.2x4 KD SPRUCE INTERIOR WALL STUDS @ 16" O.C. TO FRAME SHOWER NICHE 2.2x6 EXTERIOR STUDS TO FRAME IN WINDOW OPENING; EXISTING HEADER IS ASSUMED TO REMAIN 3.PATCH SHEATHING IN EXISTING WINDOW OPENING 4.INSTALL BLOCKING FOR BATHROOM ACCESSORIES / TOWEL BARS DURING DEMO AND FRAMING PRIOR TO NEW DRYWALL WORK 5.INSTALL CONCRETE BACKER BOARD TO NEW SHOWER WALLS 6.IT IS ASSUMED THAT EXISTING WINDOW ROUGH OPENING IS LEVEL, PLUMB, SQUARE, AND FREE OF ROT FOR NEW WINDOWS TO BE INSTALLED 7.ASSESS CONDITION OF SUBFLOOR AND UNDERLAYMENT. CURRENTLY ASSUMED TO BE ADEQUATE FOR TILE FLOORING. IF FOUND TO BE ROTTEN, DAMAGED, OR OTHERWISE DEFICIENT, CONTRACTOR TO REVIEW OPTIONS AND PRICING WITH OWNER. NEW WALL FLUSHWITH EXISTING HERE WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL= DEMO 2x4 HALF WALLTO FINISHTO FINISHSCOPE OF WORKDIVISION 7: THERMAL & MOISTURE PROTECTION1.SUPPLY & INSTALL 5/4" X 4" PRIMED PINE FOR EXTERIOR WINDOW TRIM TO MATCH EXISTINGWINDOWS2.SUPPLY & INSTALL PRIMED PINE EXTERIOR WINDOW SILL TO MATCH EXISTING WINDOWS3.SUPPLY & INSTALL PRIMED WOOD LAP SIDING "WOVEN" INTO EXISTING SIDING4.SUPPLY & INSTALL SPRAY FOAM AT WINDOW FRAMING GAPSDIVISION 8: DOORS & WINDOWS1.SUPPLY & INSTALL (1) MATHEWS BROTHERS VINYL WINDOW PER PLAN AND SCHEDULEDIVISION 9: FINISHES1.SUPPLY & INSTALL NEW TILE FLOORING, SHOWER BASE, THRESHOLD, SHOWER SHELVES, ANDSHOWER WALL TILE PER SCHEDULE 2 ON A-032.TILE SELECTIONS ARE BASED ON ARROW TILE'S QUOTE WHICH DOES NOT IDENTIFY INDIVIDUALTILES. IT IS OWNER'S RESPONSIBILITY TO CONFIRM TILE MATCHES THEIR CHOICES.3.CURRENT TILE PACKAGE ALSO INCLUDES ITEMS OWNER INTENDS TO CHANGE: CARRARRATHRESHOLD AND NICHE SHELVES AND TILE. PRICE OF ENTIRE TILE PACKAGE WILL BE ADJUSTEDONCE THESE FINAL SELECTIONS ARE MADE AND OWNER WILL BE ABLE TO REVIEW / APPROVE DIFFERENCE IN COST PRIOR TO CONTRACTOR ORDERING TILE, THRESHOLD, AND SHELVES 4.SUPPLY & INSTALL NEW BASEBOARDS PER SCHEDULE 2 ON A-03 5.SUPPLY & INSTALL PVC EXTENSION JAMBS TO WINDOW; NO INTERIOR WINDOW CASING IS INCLUDED DIVISION 10: SPECIALTIES 1.SUPPLY & INSTALL NEW SHOWER GLASS BY ALLOWANCE DIVISION 11: EQUIPMENT 1.NONE DIVISION 12: FURNISHINGS 1.SUPPLY & INSTALL VANITY, BACKSPLASH, AND COUNTERTOP PER SCHEDULE 1 ON A-04 2.SUPPLY & INSTALL NEW MEDICINE CABINET PER SCHEDULE 1 ON A-04 3.SUPPLY & INSTALL BATH ACCESSORIES PER SCHEDULE 1 ON A-04 DIVISION 13: SPECIAL CONSTRUCTION 1.NONE DIVISION 14: CONVEYING SYSTEMS 1.NONE DIVISION 15: MECHANICAL 1.ROUGH IN FIXTURES IN NEW LOCATIONS 2.SUPPLY & INSTALL SCHLUTER SHOWER PAN WITH CENTER DRAIN 3.SUPPLY & INSTALL KERDI WATERPROOFING TO SHOWER WALLS AND FLOOR 4.SUPPLY & INSTALL SHOWER HEAD, CONTROLS, AND DRAIN IN NEW LOCATIONS PER SCHEDULE 1 ON A-04 5.SUPPLY & INSTALL SINK AND FAUCET IN NEW LOCATION PER SCHEDULE 1 ON A-04 6.REINSTALL SAVED TOILET AND SEAT IN NEW LOCATION 7.CONNECT VENT PIPING TO EXISTING VENT (ASSUMED TO BE IN CORNER, BEHIND EXISTING TOILET 8.EXISTING HEAT TO REMAIN AND WILL BE UNDERNEATH VANITY SPECIFICATIONS DIVISION 1 – GENERAL REQUIREMENTS: 1.CONTRACTOR WILL OBTAIN ALL NECESSARY PERMITS FOR CONSTRUCTION, EXCEPT THAT OWNER SHALL BE RESPONSIBLE FOR WATER, SEWER, ELECTRIC, AND CABLE FEES, IF ANY. 2.CONTRACT EXCLUDES APPROVALS BY ZONING BOARD OF APPEALS, PLANNING BOARD AND/OR CONSERVATION COMMISSION. 3.CONTRACT EXCLUDES ARCHITECTURAL OVERSIGHT. 4.ANY OTHER REQUIREMENTS FROM TOWN NOT EXPLICITLY INCLUDED IN THE PLANS OR SPECS ARE NOT INCLUDED IN THIS CONTRACT. 5.SITE SURVEY IS NOT INCLUDED. 6.CONTRACTOR HAS NOT TESTED FOR ASBESTOS, LEAD PAINT, RADON, AND OTHER HAZARDOUS MATERIALS AND CONTRACT DOES NOT INCLUDE ANY REMEDIATION OR ABATEMENT WORK. 7.ALL OWNER-SUPPLIED ITEMS ARE NOT UNDER WARRANTY BY INTEGRITY OR INTEGRITY’S SUB- CONTRACTORS AND SUPPLIERS. ANY OWNER-SUPPLIED ITEMS THAT ARRIVE DAMAGED, LATE OR INCOMPLETE MAY CAUSE DELAYS TO THE SCHEDULE AND INTEGRITY WILL NOT BE HELD LIABLE FOR SUCH DELAYS. 8.CONTRACT INCLUDES ON-SITE AND IN-OFFICE JOB COORDINATION 9.REQUIRED INSURANCES INCLUDE GENERAL LIABILITY INSURANCE AND WORKER'S COMPENSATION INSURANCE 10.CONTRACTOR TO SUPPLY TEMPORARY SANI-CAN ON SITE 11.ALL CONSTRUCTION DEBRIS WILL BE PLACED IN AN ONSITE DUMPSTER PROVIDED BY CONTRACTOR AND REMOVED BY CONTRACTOR AT CONTRACTOR’S EXPENSE. 12.ALL UTILITIES USED DURING CONSTRUCTION ARE THE OWNER’S RESPONSIBILITY. 13.CONTRACTOR SHALL PROMPTLY REMOVE ALL CONSTRUCTION EQUIPMENT AND MATERIALS FROM SITE AT CONCLUSION OF CONSTRUCTION. 14.WHEREVER CONTRACTOR DRAWING OR SPECIFICATION STATES, “MATCH EXISTING,” SUCH LANGUAGE SHALL MEAN “MATCH EXISTING AS CLOSELY AS POSSIBLE FROM CURRENTLY AVAILABLE STOCK ITEMS PURCHASED LOCALLY”. 15.ALL DIMENSIONS ARE FRAMING TO FRAMING UNLESS OTHERWISE SPECIFIED. 16.ALL EXISTING STRUCTURAL COMPONENTS TO REMAIN UNLESS OTHERWISE SPECIFIED. 17. APPLIANCES, FURNITURE, ETC. SHOWN ON PLANS ARE TO BE SUPPLIED BY OWNER. 18.ROOM FINISHES PER FINISH SCHEDULE. FINISH SCHEDULE Room Name Floor Material Floor Finish Base & Case Material Base & Case Finish Wall Material Wall Finish Ceiling Material Ceiling Finish Notes Bath Beige Stone Porcelain 12X12 Navajo Brown Grout 1X6 Paint- grade pine Door and casement finish TBD pending decision from client Patch 1/2" MR drywall as needed (3) coats of joint compound, sand to smooth finish ETR Paint, Color TBD Paint all bath walls and ceiling with (2) coats of Benjamin Moore acrylic latex Aura paint Shower Beige Stone Porcelain Hexagon Navajo Brown Grout N/A N/A Matte Off White 3X6 Lt Almond Grout ETR Paint, Color TBD Threshold and shelves TBD by allowance Matte Off White 3X6 BN Lt Almond Grout Bullnose tile @ exposed edges Glass / Slate Mosaic Mosaic stripe along shower walls at center of window, and on back wall of niche TOILET DRAWN AT 29 3/4" DEEP. SHOWERGLASS DIMENSIONS TBD PER ACTUAL TOILETDIMENSIONS. EXISTING TOILET MAY VARY.Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 FAX: 413-549-7918 EMAIL: INFO@INTEGBUILD.COMDESIGN BY HFWHEAT RESIDENCEINTEGRITY3A- DATE: 10/19/2018PRELIMINARYNOT FORCONSTRUCTION30 HIGH STREET, FLORENCE, MA 01062BATH REMODELPROPOSED ELEVATIONS 1/2" = 1'-0" 1 A-03 1 A-03 SHEET: ELEVATION 1 ELEVATION 2 ELEVATION 3 2 A-03 2 A-03 PROPOSED FINISH SCHEDULE PRELIMNARY NOT FOR CONSTRUCTION A-03213 SCOPE OF WORKDIVISIONS 2 - 5: SITE WORK, CONCRETE, MASONRY, METALS1.NONEDIVISION 6: WOOD & PLASTICS1.2x4 KD SPRUCE INTERIOR WALL STUDS @ 16" O.C. TO FRAME SHOWER NICHE2.2x6 EXTERIOR STUDS TO FRAME IN WINDOW OPENING; EXISTING HEADER ISASSUMED TO REMAIN3.PATCH SHEATHING IN EXISTING WINDOW OPENING4.INSTALL BLOCKING FOR BATHROOM ACCESSORIES / TOWEL BARS DURINGDEMO AND FRAMING PRIOR TO NEW DRYWALL WORK5.INSTALL CONCRETE BACKER BOARD TO NEW SHOWER WALLS6.IT IS ASSUMED THAT EXISTING WINDOW ROUGH OPENING IS LEVEL, PLUMB,SQUARE, AND FREE OF ROT FOR NEW WINDOWS TO BE INSTALLED7.ASSESS CONDITION OF SUBFLOOR AND UNDERLAYMENT. CURRENTLYASSUMED TO BE ADEQUATE FOR TILE FLOORING. IF FOUND TO BE ROTTEN,DAMAGED, OR OTHERWISE DEFICIENT, CONTRACTOR TO REVIEW OPTIONSAND PRICING WITH OWNER.NEW WALL FLUSHWITH EXISTING HERE WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL= DEMO 2x4 HALF WALLTO FINISHTO FINISHFINISH SCHEDULE SCOPE OF WORKDIVISION 7: THERMAL & MOISTURE PROTECTION1.SUPPLY & INSTALL 5/4" X 4" PRIMED PINE FOR EXTERIOR WINDOW TRIM TO MATCH EXISTINGWINDOWS2.SUPPLY & INSTALL PRIMED PINE EXTERIOR WINDOW SILL TO MATCH EXISTING WINDOWS3.SUPPLY & INSTALL PRIMED WOOD LAP SIDING "WOVEN" INTO EXISTING SIDING4.SUPPLY & INSTALL SPRAY FOAM AT WINDOW FRAMING GAPSDIVISION 8: DOORS & WINDOWS1.SUPPLY & INSTALL (1) MATHEWS BROTHERS VINYL WINDOW PER PLAN AND SCHEDULEDIVISION 9: FINISHES1.SUPPLY & INSTALL NEW TILE FLOORING, SHOWER BASE, THRESHOLD, SHOWER SHELVES, ANDSHOWER WALL TILE PER SCHEDULE 2 ON A-032.TILE SELECTIONS ARE BASED ON ARROW TILE'S QUOTE WHICH DOES NOT IDENTIFY INDIVIDUALTILES. IT IS OWNER'S RESPONSIBILITY TO CONFIRM TILE MATCHES THEIR CHOICES.3.CURRENT TILE PACKAGE ALSO INCLUDES ITEMS OWNER INTENDS TO CHANGE: CARRARRATHRESHOLD AND NICHE SHELVES AND TILE. PRICE OF ENTIRE TILE PACKAGE WILL BE ADJUSTEDONCE THESE FINAL SELECTIONS ARE MADE AND OWNER WILL BE ABLE TO REVIEW / APPROVEDIFFERENCE IN COST PRIOR TO CONTRACTOR ORDERING TILE, THRESHOLD, AND SHELVES4.SUPPLY & INSTALL NEW BASEBOARDS PER SCHEDULE 2 ON A-035.SUPPLY & INSTALL PVC EXTENSION JAMBS TO WINDOW; NO INTERIOR WINDOW CASING ISINCLUDEDDIVISION 10: SPECIALTIES1.SUPPLY & INSTALL NEW SHOWER GLASS BY ALLOWANCEDIVISION 11: EQUIPMENT1.NONEDIVISION 12: FURNISHINGS1.SUPPLY & INSTALL VANITY, BACKSPLASH, AND COUNTERTOP PER SCHEDULE 1 ON A-042.SUPPLY & INSTALL NEW MEDICINE CABINET PER SCHEDULE 1 ON A-043.SUPPLY & INSTALL BATH ACCESSORIES PER SCHEDULE 1 ON A-04DIVISION 13: SPECIAL CONSTRUCTION1.NONEDIVISION 14: CONVEYING SYSTEMS1.NONEDIVISION 15: MECHANICAL1.ROUGH IN FIXTURES IN NEW LOCATIONS2.SUPPLY & INSTALL SCHLUTER SHOWER PAN WITH CENTER DRAIN3.SUPPLY & INSTALL KERDI WATERPROOFING TO SHOWER WALLS AND FLOOR4.SUPPLY & INSTALL SHOWER HEAD, CONTROLS, AND DRAIN IN NEW LOCATIONS PER SCHEDULE 1ON A-045.SUPPLY & INSTALL SINK AND FAUCET IN NEW LOCATION PER SCHEDULE 1 ON A-046.REINSTALL SAVED TOILET AND SEAT IN NEW LOCATION7.CONNECT VENT PIPING TO EXISTING VENT (ASSUMED TO BE IN CORNER, BEHIND EXISTINGTOILET8.EXISTING HEAT TO REMAIN AND WILL BE UNDERNEATH VANITYSPECIFICATIONS DIVISION 1 – GENERAL REQUIREMENTS: 1.CONTRACTOR WILL OBTAIN ALL NECESSARY PERMITSFOR CONSTRUCTION, EXCEPT THAT OWNER SHALL BERESPONSIBLE FOR WATER, SEWER, ELECTRIC, ANDCABLE FEES, IF ANY. 2.CONTRACT EXCLUDES APPROVALS BY ZONING BOARDOF APPEALS, PLANNING BOARD AND/OR CONSERVATIONCOMMISSION. 3.CONTRACT EXCLUDES ARCHITECTURAL OVERSIGHT. 4.ANY OTHER REQUIREMENTS FROM TOWN NOTEXPLICITLY INCLUDED IN THE PLANS OR SPECS ARENOT INCLUDED IN THIS CONTRACT. 5.SITE SURVEY IS NOT INCLUDED. 6.CONTRACTOR HAS NOT TESTED FOR ASBESTOS, LEADPAINT, RADON, AND OTHER HAZARDOUS MATERIALS ANDCONTRACT DOES NOT INCLUDE ANY REMEDIATION ORABATEMENT WORK. 7.ALL OWNER-SUPPLIED ITEMS ARE NOT UNDERWARRANTY BY INTEGRITY OR INTEGRITY’S SUB-CONTRACTORS AND SUPPLIERS. ANY OWNER-SUPPLIEDITEMS THAT ARRIVE DAMAGED, LATE OR INCOMPLETEMAY CAUSE DELAYS TO THE SCHEDULE AND INTEGRITYWILL NOT BE HELD LIABLE FOR SUCH DELAYS. 8.CONTRACT INCLUDES ON-SITE AND IN-OFFICE JOBCOORDINATION9.REQUIRED INSURANCES INCLUDE GENERAL LIABILITYINSURANCE AND WORKER'S COMPENSATIONINSURANCE10.CONTRACTOR TO SUPPLY TEMPORARY SANI-CAN ONSITE11.ALL CONSTRUCTION DEBRIS WILL BE PLACED IN ANONSITE DUMPSTER PROVIDED BY CONTRACTOR ANDREMOVED BY CONTRACTOR AT CONTRACTOR’SEXPENSE. 12.ALL UTILITIES USED DURING CONSTRUCTION ARE THEOWNER’S RESPONSIBILITY. 13.CONTRACTOR SHALL PROMPTLY REMOVE ALLCONSTRUCTION EQUIPMENT AND MATERIALS FROMSITE AT CONCLUSION OF CONSTRUCTION. 14.WHEREVER CONTRACTOR DRAWING OR SPECIFICATIONSTATES, “MATCH EXISTING,” SUCH LANGUAGE SHALLMEAN “MATCH EXISTING AS CLOSELY AS POSSIBLEFROM CURRENTLY AVAILABLE STOCK ITEMSPURCHASED LOCALLY”. 15.ALL DIMENSIONS ARE FRAMING TO FRAMING UNLESSOTHERWISE SPECIFIED. 16.ALL EXISTING STRUCTURAL COMPONENTS TO REMAINUNLESS OTHERWISE SPECIFIED. 17. APPLIANCES, FURNITURE, ETC. SHOWN ON PLANS ARETO BE SUPPLIED BY OWNER. 18.ROOM FINISHES PER FINISH SCHEDULE. FIXTURES Location Fixture Supplied Manufac.Model Model #Size/Color/NOTES Qty. By Name Spread Finish MEDICINE CABINET 1 VANITY TBD WHITE SHAKER STYE DOORS, FURNITURE LEGS 1 COUNTERTOP COWLS CLASSIC GRANITE COUNTERTOP PRICED IN CLASSIC GRANITE; CLIENT TO PICK FROM AVAILABLE SAMPLES 1 SINK TBD OVAL WHITE BOWL 1 FAUCET DOC DELTA TRINSIC 3559-SSMPU-DST STAINLESS TWO HANDLE WIDESPREAD 1 TOILET REUSE SAVED REUSE SAVED 1 TOILET SEAT REUSE SAVED REUSE SAVED 1 SHOWER HEAD DOC DELTA ACTIVTOUCH 55424-SS STAINLESS 9-SETTING ADJUSTABLE WALL MOUNT HAND SHOWER 1 WITH R10000-UNB6 ROUGH-IN VALVE 1 SHOWER VALVE TRIM DOC DELTA TRINSIC T14059-SS STAINLESS MONITOR 14 SERIES VALVE ONLY TRIM 1 WITH 50560-SS WALL SUPPLY 1 SHOWER GLASS TBD BY ALLOWANCE ACCESSORIES TBD BY ALLOWANCE TOILET DRAWN AT 29 3/4" DEEP. SHOWERGLASS DIMENSIONS TBD PER ACTUAL TOILETDIMENSIONS. EXISTING TOILET MAY VARY.A-03213 SCOPE OF WORKDIVISIONS 2 - 5: SITE WORK, CONCRETE, MASONRY, METALS1.NONEDIVISION 6: WOOD & PLASTICS1.2x4 KD SPRUCE INTERIOR WALL STUDS @ 16" O.C. TO FRAME SHOWER NICHE2.2x6 EXTERIOR STUDS TO FRAME IN WINDOW OPENING; EXISTING HEADER ISASSUMED TO REMAIN3.PATCH SHEATHING IN EXISTING WINDOW OPENING4.INSTALL BLOCKING FOR BATHROOM ACCESSORIES / TOWEL BARS DURINGDEMO AND FRAMING PRIOR TO NEW DRYWALL WORK5.INSTALL CONCRETE BACKER BOARD TO NEW SHOWER WALLS6.IT IS ASSUMED THAT EXISTING WINDOW ROUGH OPENING IS LEVEL, PLUMB,SQUARE, AND FREE OF ROT FOR NEW WINDOWS TO BE INSTALLED7.ASSESS CONDITION OF SUBFLOOR AND UNDERLAYMENT. CURRENTLYASSUMED TO BE ADEQUATE FOR TILE FLOORING. IF FOUND TO BE ROTTEN,DAMAGED, OR OTHERWISE DEFICIENT, CONTRACTOR TO REVIEW OPTIONSAND PRICING WITH OWNER.NEW WALL FLUSHWITH EXISTING HERE WALL KEY= EXISTING 2x4 INTERIOR WALL= EXISTING 2x6 EXTERIOR WALL= EXISTING 2x4 HALF WALL= DEMO. 2x4 INTERIOR WALL= DEMO. 2x6 EXTERIOR WALL= DEMO 2x4 HALF WALLTO FINISHTO FINISHSCOPE OF WORKDIVISION 7: THERMAL & MOISTURE PROTECTION1.SUPPLY & INSTALL 5/4" X 4" PRIMED PINE FOR EXTERIOR WINDOW TRIM TO MATCH EXISTINGWINDOWS2.SUPPLY & INSTALL PRIMED PINE EXTERIOR WINDOW SILL TO MATCH EXISTING WINDOWS3.SUPPLY & INSTALL PRIMED WOOD LAP SIDING "WOVEN" INTO EXISTING SIDING4.SUPPLY & INSTALL SPRAY FOAM AT WINDOW FRAMING GAPSDIVISION 8: DOORS & WINDOWS1.SUPPLY & INSTALL (1) MATHEWS BROTHERS VINYL WINDOW PER PLAN AND SCHEDULEDIVISION 9: FINISHES1.SUPPLY & INSTALL NEW TILE FLOORING, SHOWER BASE, THRESHOLD, SHOWER SHELVES, ANDSHOWER WALL TILE PER SCHEDULE 2 ON A-032.TILE SELECTIONS ARE BASED ON ARROW TILE'S QUOTE WHICH DOES NOT IDENTIFY INDIVIDUALTILES. IT IS OWNER'S RESPONSIBILITY TO CONFIRM TILE MATCHES THEIR CHOICES.3.CURRENT TILE PACKAGE ALSO INCLUDES ITEMS OWNER INTENDS TO CHANGE: CARRARRATHRESHOLD AND NICHE SHELVES AND TILE. PRICE OF ENTIRE TILE PACKAGE WILL BE ADJUSTEDONCE THESE FINAL SELECTIONS ARE MADE AND OWNER WILL BE ABLE TO REVIEW / APPROVEDIFFERENCE IN COST PRIOR TO CONTRACTOR ORDERING TILE, THRESHOLD, AND SHELVES4.SUPPLY & INSTALL NEW BASEBOARDS PER SCHEDULE 2 ON A-035.SUPPLY & INSTALL PVC EXTENSION JAMBS TO WINDOW; NO INTERIOR WINDOW CASING ISINCLUDEDDIVISION 10: SPECIALTIES1.SUPPLY & INSTALL NEW SHOWER GLASS BY ALLOWANCEDIVISION 11: EQUIPMENT1.NONEDIVISION 12: FURNISHINGS1.SUPPLY & INSTALL VANITY, BACKSPLASH, AND COUNTERTOP PER SCHEDULE 1 ON A-042.SUPPLY & INSTALL NEW MEDICINE CABINET PER SCHEDULE 1 ON A-043.SUPPLY & INSTALL BATH ACCESSORIES PER SCHEDULE 1 ON A-04DIVISION 13: SPECIAL CONSTRUCTION1.NONEDIVISION 14: CONVEYING SYSTEMS1.NONEDIVISION 15: MECHANICAL1.ROUGH IN FIXTURES IN NEW LOCATIONS2.SUPPLY & INSTALL SCHLUTER SHOWER PAN WITH CENTER DRAIN3.SUPPLY & INSTALL KERDI WATERPROOFING TO SHOWER WALLS AND FLOOR4.SUPPLY & INSTALL SHOWER HEAD, CONTROLS, AND DRAIN IN NEW LOCATIONS PER SCHEDULE 1ON A-045.SUPPLY & INSTALL SINK AND FAUCET IN NEW LOCATION PER SCHEDULE 1 ON A-046.REINSTALL SAVED TOILET AND SEAT IN NEW LOCATION7.CONNECT VENT PIPING TO EXISTING VENT (ASSUMED TO BE IN CORNER, BEHIND EXISTINGTOILET8.EXISTING HEAT TO REMAIN AND WILL BE UNDERNEATH VANITYSPECIFICATIONS DIVISION 1 – GENERAL REQUIREMENTS: 1.CONTRACTOR WILL OBTAIN ALL NECESSARY PERMITSFOR CONSTRUCTION, EXCEPT THAT OWNER SHALL BERESPONSIBLE FOR WATER, SEWER, ELECTRIC, ANDCABLE FEES, IF ANY. 2.CONTRACT EXCLUDES APPROVALS BY ZONING BOARDOF APPEALS, PLANNING BOARD AND/OR CONSERVATIONCOMMISSION. 3.CONTRACT EXCLUDES ARCHITECTURAL OVERSIGHT. 4.ANY OTHER REQUIREMENTS FROM TOWN NOTEXPLICITLY INCLUDED IN THE PLANS OR SPECS ARENOT INCLUDED IN THIS CONTRACT. 5.SITE SURVEY IS NOT INCLUDED. 6.CONTRACTOR HAS NOT TESTED FOR ASBESTOS, LEADPAINT, RADON, AND OTHER HAZARDOUS MATERIALS ANDCONTRACT DOES NOT INCLUDE ANY REMEDIATION ORABATEMENT WORK. 7.ALL OWNER-SUPPLIED ITEMS ARE NOT UNDERWARRANTY BY INTEGRITY OR INTEGRITY’S SUB-CONTRACTORS AND SUPPLIERS. ANY OWNER-SUPPLIEDITEMS THAT ARRIVE DAMAGED, LATE OR INCOMPLETEMAY CAUSE DELAYS TO THE SCHEDULE AND INTEGRITYWILL NOT BE HELD LIABLE FOR SUCH DELAYS. 8.CONTRACT INCLUDES ON-SITE AND IN-OFFICE JOBCOORDINATION9.REQUIRED INSURANCES INCLUDE GENERAL LIABILITYINSURANCE AND WORKER'S COMPENSATIONINSURANCE10.CONTRACTOR TO SUPPLY TEMPORARY SANI-CAN ONSITE11.ALL CONSTRUCTION DEBRIS WILL BE PLACED IN ANONSITE DUMPSTER PROVIDED BY CONTRACTOR ANDREMOVED BY CONTRACTOR AT CONTRACTOR’SEXPENSE. 12.ALL UTILITIES USED DURING CONSTRUCTION ARE THEOWNER’S RESPONSIBILITY. 13.CONTRACTOR SHALL PROMPTLY REMOVE ALLCONSTRUCTION EQUIPMENT AND MATERIALS FROMSITE AT CONCLUSION OF CONSTRUCTION. 14.WHEREVER CONTRACTOR DRAWING OR SPECIFICATIONSTATES, “MATCH EXISTING,” SUCH LANGUAGE SHALLMEAN “MATCH EXISTING AS CLOSELY AS POSSIBLEFROM CURRENTLY AVAILABLE STOCK ITEMSPURCHASED LOCALLY”. 15.ALL DIMENSIONS ARE FRAMING TO FRAMING UNLESSOTHERWISE SPECIFIED. 16.ALL EXISTING STRUCTURAL COMPONENTS TO REMAINUNLESS OTHERWISE SPECIFIED. 17. APPLIANCES, FURNITURE, ETC. SHOWN ON PLANS ARETO BE SUPPLIED BY OWNER. 18.ROOM FINISHES PER FINISH SCHEDULE. WINDOW SCHEDULE MANUFACTURER KEY LABEL FL.QTY.JAMB WIDTH HEIGHT R.O.DESCRIPTION EXT. FINISH INT. FINISH SCREEN GRILL TEMP.HARDWARE FINISH HEADER & JACK STUDS EGRESS MATHEWS BROS W01 1 1 2'- 3 1/2"1'-5 1/2"2'- 4" x 1'- 6" CUSTOM SIZE AWNING WINDOW; LOW E WITH ARGON GLASS N Y WHITE USE EXISTING N TOTAL 1 TOILET DRAWN AT 29 3/4" DEEP. SHOWERGLASS DIMENSIONS TBD PER ACTUAL TOILETDIMENSIONS. EXISTING TOILET MAY VARY.Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 FAX: 413-549-7918 EMAIL: INFO@INTEGBUILD.COMDESIGN BY HFWHEAT RESIDENCEINTEGRITY4A- DATE: 10/19/2018PRELIMINARYNOT FORCONSTRUCTION30 HIGH STREET, FLORENCE, MA 01062BATH REMODELSHEET:PROPOSED WINDOW SCHEDULE2 A-04 2 A-04 1 A-04 1 A-04 PROPOSED FIXTURE SCHEDULE PRELIMNARY NOT FOR CONSTRUCTION REMOVE & DISCARDTO REMAINELECTRICAL DEMO. SCOPEOF WORK1.ALL ELECTRICAL TO REMAIN INEXISTING LOCATIONS UNLESSOTHERWISE SPECIFIED2.NO WORK TO EXISTING HOUSE SMOKE/CO SYSTEM INCLUDED3.REMOVE & DISCARD (1) OUTLET4.REMOVE & DISCARD LIGHT OVER SINKAND ASSOCIATED SWITCH BATH REMOVE & DISCARD ELECTRICAL DEMO. SCOPE OF WORK 1.ALL ELECTRICAL TO REMAIN IN EXISTING LOCATIONS UNLESS OTHERWISE SPECIFIED 2.NO WORK TO EXISTING HOUSE SMOKE/ CO SYSTEM INCLUDED 3.REMOVE & DISCARD (1) OUTLET 4.REMOVE & DISCARD LIGHT OVER SINK AND ASSOCIATED SWITCH REMOVE & DISCARD CENTER IN EXISTING OPENINGTO REMAINDIVISION 16: ELECTRICAL1.ALL ELECTRICAL TO REMAIN IN EXISTINGLOCATIONS UNLESS OTHERWISE SPECIFIED2.ALL NEW ELECTRICAL DEVICE LOCATIONS TOBE CONFIRMED W/ OWNER IN FIELD; COST OFCHANGES WILL BE ADDITIONAL TO CONTRACT3.NO WORK TO EXISTING HOUSE SMOKE/COSYSTEM INCLUDED4.SWITCH TO BE TOGGLE STYLE; COLOR WHITE5.OUTLET TO BE DUPLEX STYLE; COLOR WHITE6.WIRE NEW 20 AMP CIRCUIT TO BATHROOM7.WIRE (1) QUAD OUTLET PER PLAN8.SUPPLY & INSTALL (2) WALL SCONCES ON (1)NEW SWITCH, FIXTURES TBD BY ALLOWANCE BATH ETR ETR DIVISION 16: ELECTRICAL 1.ALL ELECTRICAL TO REMAIN IN EXISTING LOCATIONS UNLESS OTHERWISE SPECIFIED 2.ALL NEW ELECTRICAL DEVICE LOCATIONS TO BE CONFIRMED W/ OWNER IN FIELD; COST OF CHANGES WILL BE ADDITIONAL TO CONTRACT 3.NO WORK TO EXISTING HOUSE SMOKE/CO SYSTEM INCLUDED 4.SWITCH TO BE TOGGLE STYLE; COLOR WHITE 5.OUTLET TO BE DUPLEX STYLE; COLOR WHITE 6.WIRE NEW 20 AMP CIRCUIT TO BATHROOM 7.WIRE (1) QUAD OUTLET PER PLAN 8.SUPPLY & INSTALL (2) WALL SCONCES ON (1) NEW SWITCH, FIXTURES TBD BY ALLOWANCE ETR ETR Development & Construction, Inc.110 Pulpit Hill RoadAmherst, Ma 01002413-549-7919 FAX: 413-549-7918 EMAIL: INFO@INTEGBUILD.COMDESIGN BY HFWHEAT RESIDENCEINTEGRITY5A- DATE: 10/19/2018PRELIMINARYNOT FORCONSTRUCTION30 HIGH STREET, FLORENCE, MA 01062BATH REMODELSHEET:EXISTING ELECTRICAL PLAN 1/2" = 1'-0" 1 E-01 1 E-01 2 E-01 2 E-01 PROPOSED ELECTRICAL PLAN 1/2" = 1'-0"E-1