41-057 CS Beam Calc-RidgeviewDevLLC-InFloorBeamA-Lot12-NorthamptonCS Beam 2016.1.1.1
kmBeamEngine 4.13.16.1
Materials Database 1547
RIDGEVIEW DEVELOPMENT LLC
LOT 12 RIDGEVIEW ESTATES
NORTHAMPTON, MA
4-23-16
1:22pm
1 of 1
All product names are trademarks of their respective owners
Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.
**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Bill Lucas
Kelly Fradet Lumber
587 North Main St
East Longmeadow, Mass
413-785-1558
Member Data
Description: BEAM IN FLOOR Member Type: Beam Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total 1.000" max. LL
Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 8.1 PLF
Filename: Beam1
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Tapered (PLF) Top 0' 0.00" 8' 0.00" 0 0 80 120 Live
Replacement Uniform (PLF) Top 8' 0.00" 11' 8.00" 0 120 Live
Additional Tapered (PLF) Top 8' 0.00" 11' 8.00" 0 120 0 45 Snow
1 2
11 8 0
11 8 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall LVL/PSL(DF/SP) End-Grain (1000psi) 3.500" 1.500" 615# --
2 11' 8.000" Wall SPF #1/#2 2x or 4x End-Grain (1150psi) 5.500" 1.500" 890# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Snow Dead
1 17# 598#
2 157# 733#
Design spans
11' 0.750"
Product: 2.0 RigidLam LVL 1-3/4 x 9-1/4 2 ply PASSES DESIGN CHECKS
Connect members with 2 rows of 16d common nails at 12.0" oc
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1810.'# 11988.'# 15% 5.75' Total Load D
Shear 607.# 5633.# 10% 10.56' Total Load D
Max. Reaction 615.# 9188.# 6% 0' Total Load D+S
TL Deflection 0.0917" 0.5531" L/999+ 5.75' Total Load D+S
LL Deflection 0.0053" 0.3688" L/999+ 6.41' Total Load S
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%