Loading...
17C-229 Florence_FP(1) sprinklersUPLOADING DOCKSTORAGESTORAGEVESTIBULE - 510sfCEILING 13'-4" A.F.F.EXISTING STREETFRONT GALLERY - 820sfCEILING 13'-7" A.F.F.EXISTING RENTALSPACE - 360sf16'-5" x 21'-11"EXISTING RENTALSPACE - 785sfSTOR - 200sf9'-3" x 21'-11"UTILITYSTORAGE SPACE - 480sfEXISTING RENTALSPACE - 400sfEXISTING RENTALSPACE - 1,175sfMECHUTILITYEXISTING RENTALSPACE - 350sfEXISTING RENTALSPACE - 350sf20'-1" X 17'-6"EXISTING RENTALSPACE - 280sf16'-2" X 17'-6"MAIN FLOOR - 2880sfHYDRUALIC REMOTE AREA Density GPM Over Sq. Feet Sprinklers OperatingGPM for Outside hose streamTotal Demand at City MainGPM at PSIDemand at Base of RiserGPM at PSIGPM for Inside hose stream#1.20ENTIRE AREA12250189.7627.77189.7626.410FLOOR PLANSCALE 3/16" = 1'-0"2'-3"2'-9"EXISTING2" CAP4'-10"PITCH TO MAIN12" PER 10'-0"PITCH TO MAIN 12" PER 10'-0"STYLECOLORHEADK =NPTORIF.ESCUT.WRENCHSPRINKLER SYMBOLSTEMPC-PLATETEMP(SIN) #CNTSYMSprinklerMODEL#ResponseQR= QuickST= StandardTypeMFG.6RELIABLEF3QRQUICKDRY PENDCHROMEƒN/A5.61"1/2"R5714HB (DEEP)F36EXIST.EXIST.QUICKPENDENTCHROMEƒN/AN/AN/AN/AN/ADEEP BELLN/ANORTH MAPLE ST DEPOT AVENORTHAMPTON BIKEWAY36" CI WATER MAINRISER ROOM28 NORTHMAPLE ST12,500 SQ.FT.SITE PLANNOT TO SCALEWATER SUPPLYTEST DATE: 10-16-2014BY: NORTHAMPTON WATERDEPARTMENTSTATIC: 59 PSIRESIDUAL: 58 PSIFLOW: 920 GPMELEVATION: 3'-0" RELATIVE TOGROUND FLOOR250'-0"100'-0"100'-0"50'-0"FLOWGAUGE100'-0"GENERAL NOTES:1.OCCUPANCY: EXISTING WAREHOUSE/GALLERY. SYSTEM DESIGNED TO LIGHT HAZARD PERNFPA 13 2013 EDITION.2.THERE IS AN EXISTING DRY SPRINKLER SYSTEM IN THIS BUILDING. RED HAWK TO ADDPENDENTS UNDER CEILING IN NEW VESTIBULE.3.SYSTEM HAS BEEN HYDRAULICALLY CALCULATED AT .20 GPM OVER 1950 SQ.FT w/ 250 GPMOUTSIDE HOSE STREAM. AREA HAS BEEN INCREASED BY 30% DUE TO DRY SYSTEM.4.ALL HANGERS ARE TO BE LOCATED AND SIZED IN ACCORDANCE WITH NFPA 13 2013 EDITION.5.STRUCTURAL LOAD BEARING ANALYSIS OF THE FIRE SPRINKLER SYSTEM AND ITS RELATEDCOMPONENTS HAS NOT BEEN INCLUDED AS PART OF THIS CONTRACT.6.SEISMIC REQUIREMENTS ARE NOT REQUIRED FOR THE FIRE SPRINKLER SYSTEM IN THISBUILDING PER ASCE 07-05 PARAGRAPH 13.1.4.(2), SEISMIC DESIGN CATEGORY B.7.7+,6$5($,672%($'(48$7(/<+($7(' $%29(ž %<2:1(53,3(,6),//(':,7+WATER AND MUST BE KEPT FROM FREEZING.8.ELECTRICAL AND/OR ALARM WIRING IS NOT INCLUDED IN THIS CONTRACT..EXISTING RISER DETAIL1.6" FLG CLASS 52 DUCTILE IRON UNDERGROUND 1'-8" AFF2.6" FLG OS&Y GATE VALVE3.6" RELIABLE MODEL C DRY VALVE (55 PSI STATIC TEST: 4-9-14)4.GENERAL ELECTRIC 34" HP 1725 HP AIR COMPRESSOR5.6" SCH 40 PIPE TO SYSTEM12345EXISTING RISER DETAILSCALE: 3/4"=1'-0"CPIPE ABOVE FINISH FLOOR (AFF)HYDRAULIC REFERENCE NODECEILING HEIGHTLSYMBOL LEGENDBRANCHLINE FABRICATION TAG4-WAY SEISMIC BRACE (IF REQUIRED)LATERAL SEISMIC BRACE (IF REQUIRED)LONGITUDINAL SEISMIC BRACE (IF REQUIRED)MAIN FABRICATION TAGREV.#DATEREVISIONDR. BYRED HAWKFIRE & SECURITY32 CHAR DRIVEWESTFIELD, MATEL 413-568-4709 FAX 413-562-7298www.RedHawkUS.comMA SC#5864, CT FRP#0040818-F1RI FPM#374, MA FA#607CRI FA#9065, CT ELC#105916-L5THIS DRAWING IS PREPARED BY RED HAWK FIRE &SECURITY FOR USE IN CONJUNCTION WITH THISPROJECT AND IS FOR USE SOLELY WITH RESPECT TORED HAWK WORK ON SUCH PROJECT. RED HAWKFIRE & SECURITY RETAINS ALL COMMON LAW,STATUTORY AND OTHER RESERVED RIGHTSINCLUDING COPYRIGHT. THIS DRAWING ANDASSOCIATED CALCULATIONS SHALL NOT BE USED BYOTHERS ON OTHER PROJECTS OR FOR PERFORMANCE,COMPLETION, OR ADDITION TO THIS PROJECT BYOTHERS EXCEPT BY AGREEMENT OF RED HAWKIN WRITING AND WITH APPROPRIATE COMPENSATIONTO SUCH.