41-056 CS Beam Calc-RidgeviewDev-F23Beam1-Lot13-NorthamptonCS Beam 2016.7.0.11
kmBeamEngine 2016.7.0.2
Materials Database 1555
RIDGEVIEW DEVELOPMENT LLC
LOT 13 RIDGEVIEW ESTATES
NORTHAMPTON, MA
9-23-16
12:50pm
1 of 1
All product names are trademarks of their respective owners
Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.
**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Bill Lucas
Kelly Fradet Lumber
587 North Main St
East Longmeadow, Mass
413-785-1558
Member Data
Description: F23 BEAM 1 Member Type: Beam Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: (See Below)
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total 1.000" max. LL
Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 20.8 PLF
Filename: Beam1
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 18' 11.00" 470 118 Live
Additional Uniform (PLF) Top 0' 0.00" 7' 6.00" 0 80 Live
Additional Uniform (PLF) Top 0' 0.00" 7' 6.00" 250 63 Live
Point (LBS) Top 7' 6.00" 4066 1089 Snow
1 2 3
3 7 8 15 3 8
18 11 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall Concrete/Masonry 3.500" 1.500" -- -5718#
2 3' 7.500" Wall Steel 8.000" 3.220" 16907# --
3 18' 11.000" Wall SPF #1/#2 2x or 4x End-Grain (1150psi) 5.500" 1.500" 3820# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 -3458# -2423# -1306#
2 9892# 5987# 4998#
3 2838# 503# 981#
Design spans
3' 4.875" 14' 10.875"
Product: 2.0 RigidLam LVL 1-3/4 x 11-7/8 4 ply PASSES DESIGN CHECKS
Connect members with 2 rows of 1/2" diameter bolts at 24.0" oc
Design assumes continuous lateral bracing along the top chord.
No lateral bracing required along the bottom chord.
Review gravity uplift reaction force of 5719lbs at bearing 1 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 11953.'# 44258.'# 27% 12.57' Even Spans D+L
Negative Moment 21262.'# 50897.'# 41% 3.62' Total Load D+0.75(L+S)
Negative Unbrcd 21262.'# 50897.'# 41% 3.62' Total Load D+0.75(L+S)
Shear 8452.# 18481.# 45% 3.63' Total Load D+0.75(L+S)
Max. Reaction 16907.# 42000.# 40% 3.62' Total Load D+0.75(L+S)
TL Deflection 0.2283" 0.7453" L/783 11.08' Even Spans D+0.75(L+S)
LL Deflection 0.1644" 0.4969" L/999+ 11.08' Even Spans 0.75(L+S)
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %