Loading...
IECCUA15 _0181_Matt C 87 Bridge St_Nhton Bld1 Left unit 1 UA cost 1711092015 IECC Building UA Compliance Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 DRAFT REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Elements Insulation Levels 2015 IECC As Designed Shell UA Check Ceilings:25.2 24.7 Above-Grade Walls:110.7 105.8 Windows and Doors:52.3 37.2 Slab Floor:7.6 7.6 Floors Over Garage:8.9 7.8 Overall UA (Design must be equal or lower):204.7 183.1 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1.2)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 10.6%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 9 November 2017 2015 IECC Energy Cost Compliance Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. DRAFT Annual Energy Cost $/yr 2015 IECC As Designed Heating 881 735 Cooling 95 79 Water Heating 154 154 SubTotal - Used to Determine Compliance 1130 968 Lights & Appliances 953 940 Photovoltaics -0 -0 Service Charge 48 48 Total 2131 1956 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 14.3%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 9 November 2017 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.