Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
fwhers_0073_0181_mattc87bridgest_nhtonbld1lf1
BldgSummary_0181_Matt C 87 Bridge St_Nhton Bld1 Left unit 1 171109.pdf Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Property/Builder Information Building Name Bridge Street Duplex Bld1 Lt #1 Owner's Name Matthew Campagnari Property Address 87 Bridge St Bld1 Left unit 1 City, St, Zip Northampton, MA 01077 Phone Number 413-237-5872 Builder's Name Matthew Campagnari Phone Number 413-237-5872 Email Address mattycamp@yahoo.com Plan/Model Name Matthew Campagnari Custom Home Community/Development Northampton Permit Date/Number Organization Information Organization Name Noonan Energy Corp Address 86 Robbins Road City, St, Zip Springfield , MA 01104 Phone Number 413-427-2423 Website www.noonanenergy.com Rating/RESNET Information Provider ID 1998-146 Sample Set ID 00000000 Registry ID Registry Date Registered Rater's Name Paul J. DellaTorre Rater's ID 8776762 Rater's Email pauld@noonanenergy Last Field Insp 2017-03-22 Rating Type ProjectedWorstCase Reason for Rating New Home Rating Number 0073_0181 Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 2 of 12 General Building Information Area of Conditioned. Space(sq ft) 2304 Volume of Conditioned. Space 15632 Year Built 2017 Housing Type Duplex, single unit Level Type(Apartments Only) None Floors on or Above-Grade 3+ Number of Bedrooms 3 Foundation Type Slab Enclosed Crawl Space Type N/A Number of Stories Including Conditioned Basement 3 Thermal Boundary Location N/A Slab Floor Information Name Library Entry Area(sq ft) Depth Below Grade(ft) Full Perimeter(ft) Exposed Perimeter(ft) On-Grade Perimeter(ft) Slab R10 perimeter 589 0.0 135 87 87 Slab Floor Library List Slab Floor: R10 perimeter Slab Covering None Perimeter Insulation (R-Value) 10.0 Perimeter Insulation Depth (ft) 2.0 Under-Slab Insulation (R-Value) 0.0 Under-Slab Insulation Width (ft) 0.0 Slab Insulation Grade 1 Radiant Slab No Note Frame Floor Information Name Library Entry Location Area(sq ft) Uo Value 2nd to garage R-38 Btwn cond & garage 270 0.029 Frame Floor Library List Floor: R-38 Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 3 of 12 Frame Floor Library List Information From Quick Fill Screen Continous Insulation R-Value 0.0 Cavity Insulation R-Value 38.0 Cavity Insulation Thickness (in.) 11.5 Cavity Insulation Grade 1 Joist Size (w x h, in) 1.5 x 11.5 Joist Spacing (in oc) 16.0 Framing Factor - (default) 0.1300 Floor Covering HARDWOOD Note Rim and Band Joist Information Name Location Area(sq ft) Continuous Ins Framed Cavity Ins Cavity Ins Thk(in) Joist Spacing Insulation Grade Uo Value 1-2 to amb Cond -> ambient 52.00 0.0 21.0 5.5 16.0 1 0.047 1-2 to garage Cond -> garage 35.00 0.0 21.0 5.5 16.0 1 0.047 1-2 to adiabatic Cond -> another cond unit 49.00 0.0 21.0 5.5 16.0 1 0.047 2-3 to amb Cond -> ambient 87.00 0.0 21.0 5.5 16.0 1 0.047 2-3 to adiabatic Cond -> another cond unit 49.00 0.0 21.0 5.5 16.0 1 0.047 Above-Grade Wall Name Library Entry Location Exterior Color Area(sq ft) Uo Value 1st to amb R-21 Cond -> ambient Medium 419.00 0.058 1st to gar R-21 Cond -> ambient Medium 274.00 0.058 1st to adiabatic R-21 Cond -> another cond unit Medium 388.00 0.058 2nd to amb R-21 Cond -> ambient Medium 692.00 0.058 2nd to adiabatic R-21 Cond -> another cond unit Medium 388.00 0.058 3rd to amb R-21 Cond -> ambient Medium 210.00 0.058 3rd to adiabatic R-21 Cond -> ambient Medium 240.00 0.058 Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 4 of 12 Above-Grade Wall Library List Above-Grade Wall: R-21 Information From Quick Fill Screen Wall Construction Type Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 21.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 0.5 Note Window Information Overhang Interior Adjacent Name Wall Assignment Orient U-Value SHGC Area (sqft) Depth (ft) To Top (ft) To Btm (ft) Winter Shading Summer Shading Winter Shading Summer Shading 1F AGWall 1 Northwest 0.270 0.280 25.00 6.0 1.0 5.7 0.85 0.70 None None 1F AGWall 1 Northwest 0.270 0.280 8.40 8.0 1.0 4.2 0.85 0.70 None None 1L AGWall 1 Northeast 0.270 0.280 25.00 0.0 0.0 0.0 0.85 0.70 None None 2F AGWall 3 Northwest 0.270 0.280 37.40 0.0 0.0 0.0 0.85 0.70 None None 2L AGWall 3 Northwest 0.270 0.280 37.40 0.0 0.0 0.0 0.85 0.70 None None 2B AGWall 5 Southeast 0.270 0.280 12.50 1.0 1.0 5.7 0.85 0.70 None None 3L AGWall 6 Northeast 0.270 0.280 25.00 0.0 0.0 0.0 0.85 0.70 None None Door Information Name Library Entry Wall Assignment Opaque Area(sq ft) Uo Value R-Value of Opaque Area Storm Door front Fiberglass Door AGWall 1 20.0 0.184 4.5 No back Fiberglass Door AGWall 1 20.0 0.184 4.5 No to garage Fiberglass Door AGWall 2 20.0 0.184 4.5 No 2nd to deck Fiberglass Door AGWall 4 20.0 0.184 4.5 No Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 5 of 12 Roof Information Name Library Entry Ceiling Area(sq ft) Roof Area(sq ft) Exterior Color Radiant Barrier Type Uo Value Cement or Clay Tiles Roof Tile Ventilation Ceiling Vaulted R 38 attic cieling 812.00 1123.00 Medium No Vaulted 0.025 No No flat R-38 Blown, Attic 157.00 196.00 Medium No Attic 0.026 No No Roof Library List Ceiling: R 38 attic cieling Information From Quick Fill Screen Continous Insulation (R-Value) 23.0 Cavity Insulation (R-Value) 15.0 Cavity Insulation Thickness (in) 5.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 5.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Vaulted Note Safco attic insulation - spray attic ceiling Ceiling: R-38 Blown, Attic Information From Quick Fill Screen Continous Insulation (R-Value) 25.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 16.0 Framing Factor - (default) 0.1412 Ceiling Type Attic Note Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 6 of 12 Mechanical Equipment Number of Mechanical Systems 2 Heating SetPoint(F) 68.00 Heating Setback Thermostat Present Cooling SetPoint(F) 78.00 Cooling Setup Thermostat Present ASHP: MXZ-4C36NAHZ mixed Fuel Type Electric Heating Seasonal Efficiency 10.70 HSPF Compressor Heating Output Capacity at 17F (kBtuh) 35.0 Compressor Heating Output Capacity at 47F (kBtuh) 45.0 Electric Resistance Backup Capacity (kW) 10 Cooling Output Capacity (kBtuh) 36.0 Cooling Seasonal Efficiency 17.50 SEER Desuperheater No Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Heating Load Served 100 Percent Cooling Load Served 100 DHW: heat pump 3.42 Water Heater Type Heat pump Fuel Type Electric Energy Factor 3.42 Recovery Efficiency 0.00 Water Tank Size (gallons) 50 Extra Tank Insulation (R-Value) 0.0 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 7 of 12 Mechanical Equipment Percent Load Served 100 DHW Efficiencies All bath faucets & showers <= 2gpm false All DHW pipes fully insulated >= R-3 false Recirculation type None (standard system) Farthest fixture to DHW heater 55 TOTAL Pipelength for longest DHW run 85 DWHR unit present? false DHW Diagnostics dhwGpd 51.15 peRatio 1.00 dishwasherGpd 4.32 clothesWasherHotWaterGPD 3.89 EDeff 1.00 ewaste 31.88 tmains 55.40 dwhrWhInletTempAdj 0.00 pumpConsKwh 0.00 pumpConsMmbtu 0.00 Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 8 of 12 Duct Systems Name duct Conditioned Floor Area(sq ft) 2304.0 # of Returns 6 Heating System MXZ-4C36NAHZ mixed Cooling System MXZ-4C36NAHZ mixed Supply Duct Surface Area(sq ft) 466.6 Return Duct Surface Area(sq ft) 345.6 Duct Leakage Qualitative Assessment LtO Test Exemption claimed Duct Leakage to Outside Supply+Return Not Applicable Supply Only Not Applicable Return Only Not Applicable Total Duct Leakage Not Applicable Type Location Percent Location R-Value Supply Conditioned space 100.0 0.0 Return Conditioned space 100.0 0.0 Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 9 of 12 Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type Blower door test Heating Season Infiltration Value 2.75 ACH @ 50 Pascals Cooling Season Infiltration Value 2.75 ACH @ 50 Pascals Shelter Class 4 Code Verification Tested Mechanical Ventilation for IAQ Type Balanced Rate(cfm) 99 Sensible Recovery Efficiency(%) 65.00 Total Recovery Efficiency(%) 65.00 Hours per Day 24.0 Fan Power (watts) 60.00 ECM Fan Motor false Ventilation Strategy for Cooling Cooling Season Ventilation Natural Ventilation Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 10 of 12 Lights and Appliances Rating/RESNET audit Ceiling Fan CFM / Watt 0.00 Refrigerator kWh/yr 691 Refrigerator Location Conditioned Range/Oven Fuel Type Electric Induction Range No Convection Oven No Dishwasher Energy Factor 0.46 Dishwasher kWh/yr 0 Place Setting Capacity 12 Clothes Dryer Fuel Type Electric Location Conditioned Moisture Sensing No CEF 2.62 Clothes Washer Location Conditioned LER (kWh/yr) 704 IMEF 0.331 Capacity (CU.Ft) 2.874 Electricity Rate 0.08 Gas Rate 0.58 Annual Gas Cost 23.00 Qualifying Light Fixtures Interior CFLs % 90.0 Interior Fluorescent % 10.0 Exterior Lights % 100.0 Garage Lights % 100.0 Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 11 of 12 Mandatory Requirements IECC Requirements Verified IECC 04 false Verified IECC 06 false Verified IECC 09 false Verified IECC 12 false Verified IECC 15 true Verified NY-ECCC 2016 false Verified IECC MI false EPA Requirements Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist(National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Amount Refrigerators 0 Ceiling Fans 0 Exhaust Fans 0 Dishwashers 0 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grad: false Basement Floor Area 0.00 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist false EPA Field App ID Building Summary Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Page 12 of 12 DOE Zero Energy Ready Home Home Builder ID Number Mandatory Requirements Verified Fenestration false Verified Insulation false Verified Duct Location false Verified Appliance false Verified Lighting false Verified Fan Efficiency false Verified Water Efficiency false Verified EPA Indoor airPLUS false Verified Renewable Energy Ready Solar Electric false Optional Home Builder Commitments for Recognition Certified under the EPA WaterSense for New Homes Program No Certified under the IBHS fortified for Safer Living Program No Followed the DOE Zero Energy Ready Home Quality Management Guidelines No The buyer of this home signed a waiver giving DOE Zero Energy Ready Home access to utility bill data for one year. No Active Solar System Type None Collector Loop Type None Collector Type None Collector Orientation None Area(sq ft) 0.0 Tilt(degrees) 0.0 Volume(cu ft/gal) 0.0 QuickAnalysis _0181_Matt C 87 Bridge St_Nhton Bld1 Left unit 1 171109.pdf Quick Analysis Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Registry ID: Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Design Load (kBtu/hr) Heating 19.1 Cooling 10.1 Annual Load (MMBtu/yr) Heating 32.6 Cooling 2.4 Water Heating 11.5 Annual Consumption (MMBtu/yr) Heating 16.1 Cooling 0.5 Water Heating 3.2 Lights & Appliances 22.6 Photovoltaics -0.0 Total 42.4 Annual Energy Cost ($/yr) Heating 670 Cooling 22 Water Heating 132 Lights & Appliances 940 Photovoltaics -0 Service Charges 48 Total 1812 Total Area (sq ft) Conditioned Space 2304 Shell Area 4711 Above Grade Shell Area 4711 Foundation Wall 0.0 Slab Floor 589 Floor 270 Rim And Band Joist 272.0 Above-Grade Wall 2611.0 Window 170.7 Total Area (sq ft) Door 80.0 Ceiling 969 Skylight 0.0 Duct 812.2 Ratios Window-to-Wall 0.093 Window-to-Floor 0.074 Window Area by Orientation (sq ft) North 0.0 Northeast 50.0 East 0.0 Southeast 12.5 South 0.0 Southwest 0.0 West 0.0 Northwest 108.2 Codes IECC 2015 Performance Passes IECC 2012 Performance Fails IECC 2009 Performance Fails IECC 2006 Performance Fails IECC 2004 Performance Fails IECC 2003 Performance Passes IECC 2001 Performance Passes IECC 1998 Performance Passes Iowa Code Fails Michigan Code Fails Illinois Code Passes ECC of NV Performance Passes NY-ECCC 2016 Performance Fails North Carolina Code Fails North Carolina HERO Fails Quick Analysis Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 Registry ID: Page 2 of 2 Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Programs EPA ENERGY STAR 3.0 Fails EPA ENERGY STAR 3.0 Guam, Puerto Rico, Hawaii Fails EPA ENERGY STAR 3.1 Fails Tax Credit Passes DOE Zero Energy Ready Home Fails HERS Index 45 WH Infiltration Natural ACH 0.17 ACH50 (Pa) 2.75 CFM50 (Pa) 716 ELA (sq.in) 39.3 SLA 0.00012 CFM50/sf shell 0.15 WH Ventailation (continuous) Type Balanced AsIs (equiv. cfm) 99 62.2-2010 (cfm) 53 62.2-2013 (cfm) 99 IECCUA15 _0181_Matt C 87 Bridge St_Nhton Bld1 Left unit 1 UA cost 171109.pdf 2015 IECC Building UA Compliance Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Bridge St_Nhton Bld1 Lf 1 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 DRAFT REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Elements Insulation Levels 2015 IECC As Designed Shell UA Check Ceilings: 25.2 24.7 Above-Grade Walls: 110.7 105.8 Windows and Doors: 52.3 37.2 Slab Floor: 7.6 7.6 Floors Over Garage: 8.9 7.8 Overall UA (Design must be equal or lower): 204.7 183.1 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1.2) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 10.6%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 9 November 2017 2015 IECC Energy Cost Compliance Property Matthew Campagnari 87 Bridge St Bld1 Left unit 1 Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duplex Bld1 Lt #1 HERS_0073_0181_Matt C 87 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0181 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. DRAFT Annual Energy Cost $/yr 2015 IECC As Designed Heating 881 735 Cooling 95 79 Water Heating 154 154 SubTotal - Used to Determine Compliance 1130 968 Lights & Appliances 953 940 Photovoltaics -0 -0 Service Charge 48 48 Total 2131 1956 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 14.3%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 9 November 2017 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. AHRI mini split MXZ-4C36NAHZ mixed ducted and not 17.45 seer.pdf Certificate of Product Ratings CERTIFICATE NO.: † * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user’s individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on “Verify Certificate” link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2014 Air-Conditioning, Heating, and Refrigeration Institute AHRI Certified Reference Number: 7434486 Date: 11/6/2017 Product: Variable Speed Multi-Split Heat Pump Outdoor Unit Model Number: MXZ-4C36NAHZ Indoor Unit Type: Mixed Ducted and Non-ducted Indoor Units Manufacturer: MITSUBISHI ELECTRIC COOLING & HEATING Trade/Brand name: MR. SLIM Series name: Manufacturer responsible for the rating of this system combination is MITSUBISHI ELECTRIC COOLING & HEATING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 36000 EER Rating (Cooling): 12.65 SEER Rating (Cooling): 17.45 Heating Capacity(Btuh) @ 47 F: 45000 Region IV HSPF Rating (Heating): 10.70 Heating Capacity(Btuh) @ 17 F: 35000 CERTIFIED RATINGS FOR VARIABLE-SPEED, MINI- AND MULTI-SPLIT SYSTEMS ARE VALID FOR ALL COMBINATIONS OF INDOOR UNITS (BASED ON COMBINATION TYPES) WITH THE SPECIFIC OUTDOOR UNIT LISTED ABOVE AND IN THE AHRI DIRECTORY OF CERTIFIED EQUIPMENT. VISIT WWW.AHRIDIRECTORY.ORG TO VERIFY THAT THIS COMBINATION IS AN ACTIVE LISTING AND THE DATA LISTED ON THIS CERTIFICATE IS ACCURATE. SEARCH ON THE AHRI REFERENCE # TO QUICKLY LOCATE THIS COMBINATION IN THE DIRECTORY. This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2016. 131544606782836213