Loading...
QuickAnalysis_0180_Matt C 9 Pomeroy Ter. Nhton 2nd Floor HERS 43 171109Quick Analysis Property Matthew Campagnari 2nd Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 2nd fl HERS_0073_0180_Matt C 9 Pomeroy Ter. Nhton 2nd Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0180 Rater ID:8776762 Registry ID: Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Design Load (kBtu/hr) Heating 12.8 Cooling 9.0 Annual Load (MMBtu/yr) Heating 16.9 Cooling 4.8 Water Heating 7.4 Annual Consumption (MMBtu/yr) Heating 18.4 Cooling 1.3 Water Heating 7.8 Lights & Appliances 15.0 Photovoltaics -0.0 Total 42.4 Annual Energy Cost ($/yr) Heating 607 Cooling 53 Water Heating 256 Lights & Appliances 623 Photovoltaics -0 Service Charges 168 Total 1707 Total Area (sq ft) Conditioned Space 1358 Shell Area 4266 Above Grade Shell Area 4266 Foundation Wall 0.0 Slab Floor 0 Floor 1358 Rim And Band Joist 155.0 Above-Grade Wall 1395.0 Window 156.3 Total Area (sq ft) Door 40.0 Ceiling 1358 Skylight 0.0 Duct 478.7 Ratios Window-to-Wall 0.112 Window-to-Floor 0.115 Window Area by Orientation (sq ft) North 0.0 Northeast 34.0 East 0.0 Southeast 60.0 South 0.0 Southwest 60.0 West 0.0 Northwest 2.3 Codes IECC 2015 Performance Passes IECC 2012 Performance Fails IECC 2009 Performance Fails IECC 2006 Performance Fails IECC 2004 Performance Fails IECC 2003 Performance Passes IECC 2001 Performance Passes IECC 1998 Performance Passes Iowa Code Fails Michigan Code Fails Illinois Code Passes ECC of NV Performance Passes NY-ECCC 2016 Performance Fails North Carolina Code Fails North Carolina HERO Fails Quick Analysis Property Matthew Campagnari 2nd Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 2nd fl HERS_0073_0180_Matt C 9 Pomeroy Ter. Nhton 2nd Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0180 Rater ID:8776762 Registry ID: Page 2 of 2 Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Programs EPA ENERGY STAR 3.0 Fails EPA ENERGY STAR 3.0 Guam, Puerto Rico, Hawaii Fails EPA ENERGY STAR 3.1 Fails Tax Credit Passes DOE Zero Energy Ready Home Fails HERS Index 43 WH Infiltration Natural ACH 0.16 ACH50 (Pa)3.00 CFM50 (Pa)543 ELA (sq.in)29.8 SLA 0.00015 CFM50/sf shell 0.13 WH Ventailation (continuous) Type Balanced AsIs (equiv. cfm)70 62.2-2010 (cfm)36 62.2-2013 (cfm)63