Loading...
fwhers_0073_0179_mattc9pomeroyter_nhton1stfloor BldgSummary_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor LP heat h20 171109.pdf Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Property/Builder Information Building Name Pomeroy Duplex 1st fl Owner's Name Matthew Campagnari Property Address 1st Floor 9 Pomeroy Ter City, St, Zip Northhampmton, MA 01060 Phone Number 413-237-5872 Builder's Name Matthew Campagnari Phone Number 413-237-5872 Email Address mattycamp@yahoo.com Plan/Model Name Matthew Campagnari Custom Home Community/Development Northampton Permit Date/Number Organization Information Organization Name Noonan Energy Corp Address 86 Robbins Road City, St, Zip Springfield , MA 01104 Phone Number 413-427-2423 Website www.noonanenergy.com Rating/RESNET Information Provider ID 1998-146 Sample Set ID 00000000 Registry ID Registry Date Registered Rater's Name Paul J. DellaTorre Rater's ID 8776762 Rater's Email pauld@noonanenergy Last Field Insp 2017-03-22 Rating Type Projected Rating Reason for Rating New Home Rating Number 0073_179 Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 2 of 12 General Building Information Area of Conditioned. Space(sq ft) 1240 Volume of Conditioned. Space 9924 Year Built 2017 Housing Type Apartment, end unit Level Type(Apartments Only) Lowest level Floors on or Above-Grade 1 Number of Bedrooms 2 Foundation Type Unconditioned basement Enclosed Crawl Space Type N/A Number of Stories Including Conditioned Basement 1 Thermal Boundary Location REM Default Foundation Wall Information Name Library Entry Location Length(ft) Total Height(ft) Depth Below Grade(ft) Height Above Grade(ft) Uo Value Combo* Uo Value (wall only) 0 front R10. Continuous Uncond bsmt->amb/grnd 38.5 8.0 6.0 2.0 0.063 0.091 0 left R10. Continuous Uncond bsmt->amb/grnd 37.5 8.0 6.0 2.0 0.063 0.091 0 back R10. Continuous Uncond bsmt->amb/grnd 52.5 8.0 6.0 2.0 0.064 0.091 0 right R10. Continuous Uncond bsmt->amb/grnd 38.5 8.0 6.0 2.0 0.063 0.091 * Uo Value Combo combines wall, airfilm, and soil path Foundation Wall Library List Foundation Wall: R10. Continuous Type Solid concrete or stone Thickness(in) 12.0 Studs None Interior Insulation Continuous R-Value 10.0 Frame Cavity R-Value 0.0 Cavity Insulation Grade 1 Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 3 of 12 Foundation Wall Library List Ins top 0.0 ft from top of wall Ins Bottom 0.0 ft from bottom of wall Exterior Insulation R-Value 0.0 Ins top 0.0 ft from top of wall Ins bottom 0.0 ft below grade Note Frame Floor Information Name Library Entry Location Area(sq ft) Uo Value 1st to Ucbsmnt R-38 Btwn cond & uncond bsmt 1240 0.029 Frame Floor Library List Floor: R-38 Information From Quick Fill Screen Continous Insulation R-Value 0.0 Cavity Insulation R-Value 38.0 Cavity Insulation Thickness (in.) 11.5 Cavity Insulation Grade 1 Joist Size (w x h, in) 1.5 x 11.5 Joist Spacing (in oc) 16.0 Framing Factor - (default) 0.1300 Floor Covering HARDWOOD Note Rim and Band Joist Information Name Location Area(sq ft) Continuous Ins Framed Cavity Ins Cavity Ins Thk(in) Joist Spacing Insulation Grade Uo Value 0 Ucbsmnt - amb Cond -> uncond bsmt 166.80 0.0 38.0 9.5 16.0 1 0.029 Above-Grade Wall Name Library Entry Location Exterior Color Area(sq ft) Uo Value Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 4 of 12 Above-Grade Wall Name Library Entry Location Exterior Color Area(sq ft) Uo Value 1st to amb R-21 cavity r 3 cont Cond -> ambient Medium 1096.00 0.048 1st to ucbsmnt R-21 cavity r 3 cont Cond -> uncond bsmt Medium 158.00 0.048 1st to adiabatic R-21 cavity r 3 cont Cond -> uncond bsmt Medium 64.00 0.048 Above-Grade Wall Library List Above-Grade Wall: R-21 cavity r 3 cont Information From Quick Fill Screen Wall Construction Type Standard Wood Frame Continuous Insulation (R-Value) 3.0 Frame Cavity Insulation (R-Value) 21.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 0.5 Note Window Information Overhang Interior Adjacent Name Wall Assignment Orient U-Value SHGC Area (sqft) Depth (ft) To Top (ft) To Btm (ft) Winter Shading Summer Shading Winter Shading Summer Shading 1 FW AGWall 1 Northeast 0.260 0.320 24.00 0.0 0.0 0.0 0.85 0.70 None None 1 FW AGWall 1 Northeast 0.260 0.320 12.00 6.0 1.0 5.5 0.85 0.70 None None 1 LW AGWall 1 Southeast 0.260 0.320 12.00 17.5 1.0 5.5 0.85 0.70 None None 1 LW AGWall 1 Southeast 0.260 0.320 24.00 0.0 0.0 0.0 0.85 0.70 None None 1 BW AGWall 1 Southwest 0.260 0.320 36.00 0.0 0.0 0.0 0.85 0.70 None None 1 RW AGWall 1 Northwest 0.260 0.320 24.00 0.0 0.0 0.0 0.85 0.70 None None 1 RW AGWall 1 Northwest 0.260 0.320 10.00 12.0 1.0 4.2 0.85 0.70 None None 1 RW AGWall 1 Northwest 0.260 0.320 2.30 0.0 0.0 0.0 0.85 0.70 None None Door Information Name Library Entry Wall Assignment Opaque Uo Value R-Value of Storm Door Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 5 of 12 Area(sq ft) Opaque Area 0 Ucbsmnt to amb Fiberglass Door FndWall 3 20.0 0.184 4.5 No 1 front Fiberglass Door AGWall 2 20.0 0.184 4.5 No 1 right to deck Fiberglass Door AGWall 1 20.0 0.184 4.5 No Roof Information Name Library Entry Ceiling Area(sq ft) Roof Area(sq ft) Exterior Color Radiant Barrier Type Uo Value Cement or Clay Tiles Roof Tile Ventilation Cieling to Con unit Ceiling-Adiabatic 1240.00 1240.00 Medium No Adiabatic 0.599 No No Roof Library List Ceiling: Ceiling-Adiabatic Information From Quick Fill Screen Continous Insulation (R-Value) 0.0 Cavity Insulation (R-Value) 0.0 Cavity Insulation Thickness (in) 0.0 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Adiabatic Note Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 6 of 12 Mechanical Equipment Number of Mechanical Systems 3 Heating SetPoint(F) 68.00 Heating Setback Thermostat Present Cooling SetPoint(F) 78.00 Cooling Setup Thermostat Present Heat: 96AFUE LP Fur 39K SystemType Fuel-fired air distribution Fuel Type Propane Rated Output Capacity (kBtuh) 39.0 Seasonal Equipment Efficiency 96.0 AFUE Auxiliary Electric 162 kWh/yr Note American Standard S9V2 Number Of Units 1 Location Uncond bsmnt/enclosed crawl Performance Adjustment 100 Percent Load Served 100 Cool: 14SEER A/C 1.5 ton System Type Air conditioner Fuel Type Electric Rated Output Capacity (kBtuh) 18.0 Seasonal Equipment Efficiency 14.0 SEER Sensible Heat Fraction (SHF) 0.70 Note Number Of Units 1 Location Uncond bsmnt/enclosed crawl Performance Adjustment 100 Percent Load Served 100 DHW: Demand-LP 0.95 EF******* Water Heater Type Instant water heater Fuel Type Propane Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 7 of 12 Mechanical Equipment Energy Factor 0.95 Recovery Efficiency 0.00 Water Tank Size (gallons) 0 Extra Tank Insulation (R-Value) 0.0 Note Number Of Units 1 Location Uncond bsmnt/enclosed crawl Performance Adjustment 100 Percent Load Served 100 DHW Efficiencies All bath faucets & showers <= 2gpm false All DHW pipes fully insulated >= R-3 false Recirculation type None (standard system) Farthest fixture to DHW heater 70 TOTAL Pipelength for longest DHW run 85 DWHR unit present? false DHW Diagnostics dhwGpd 35.00 peRatio 0.99 dishwasherGpd 1.04 clothesWasherHotWaterGPD -0.06 EDeff 1.00 ewaste 31.88 tmains 55.40 dwhrWhInletTempAdj 0.00 pumpConsKwh 0.00 pumpConsMmbtu 0.00 Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 8 of 12 Duct Systems Name ducts Conditioned Floor Area(sq ft) 1240.0 # of Returns 4 Heating System 96AFUE LP Fur 39K Cooling System 14SEER A/C 1.5 ton Supply Duct Surface Area(sq ft) 334.8 Return Duct Surface Area(sq ft) 248.0 Duct Leakage Qualitative Assessment Not Applicable Duct Leakage to Outside Supply+Return 40.00 CFM @ 25 Pascals Supply Only Not Applicable Return Only Not Applicable Total Duct Leakage 40.00 CFM @ 25 Pascals Duct Tightness Test Postconstruction Test Type Location Percent Location R-Value Supply Unconditioned basement 100.0 8.0 Return Unconditioned basement 100.0 8.0 Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 9 of 12 Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type Blower door test Heating Season Infiltration Value 2.75 ACH @ 50 Pascals Cooling Season Infiltration Value 2.75 ACH @ 50 Pascals Shelter Class 4 Code Verification Tested Mechanical Ventilation for IAQ Type Balanced Rate(cfm) 60 Sensible Recovery Efficiency(%) 65.00 Total Recovery Efficiency(%) 65.00 Hours per Day 24.0 Fan Power (watts) 40.00 ECM Fan Motor false Ventilation Strategy for Cooling Cooling Season Ventilation Natural Ventilation Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 10 of 12 Lights and Appliances Rating/RESNET audit Ceiling Fan CFM / Watt 0.00 Refrigerator kWh/yr 500 Refrigerator Location Conditioned Range/Oven Fuel Type Electric Induction Range No Convection Oven No Dishwasher Energy Factor 0.00 Dishwasher kWh/yr 200 Place Setting Capacity 12 Clothes Dryer Fuel Type Electric Location Conditioned Moisture Sensing Yes CEF 2.62 Clothes Washer Location Conditioned LER (kWh/yr) 96 IMEF 3.060 Capacity (CU.Ft) 3.810 Electricity Rate 0.11 Gas Rate 1.22 Annual Gas Cost 11.00 Qualifying Light Fixtures Interior CFLs % 90.0 Interior Fluorescent % 10.0 Exterior Lights % 100.0 Garage Lights % 100.0 Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 11 of 12 Mandatory Requirements IECC Requirements Verified IECC 04 false Verified IECC 06 false Verified IECC 09 false Verified IECC 12 false Verified IECC 15 true Verified NY-ECCC 2016 false Verified IECC MI false EPA Requirements Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist(National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Amount Refrigerators 0 Ceiling Fans 0 Exhaust Fans 0 Dishwashers 0 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grad: false Basement Floor Area 0.00 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist false EPA Field App ID Building Summary Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Page 12 of 12 DOE Zero Energy Ready Home Home Builder ID Number Mandatory Requirements Verified Fenestration false Verified Insulation false Verified Duct Location false Verified Appliance false Verified Lighting false Verified Fan Efficiency false Verified Water Efficiency false Verified EPA Indoor airPLUS false Verified Renewable Energy Ready Solar Electric false Optional Home Builder Commitments for Recognition Certified under the EPA WaterSense for New Homes Program No Certified under the IBHS fortified for Safer Living Program No Followed the DOE Zero Energy Ready Home Quality Management Guidelines No The buyer of this home signed a waiver giving DOE Zero Energy Ready Home access to utility bill data for one year. No Active Solar System Type None Collector Loop Type None Collector Type None Collector Orientation None Area(sq ft) 0.0 Tilt(degrees) 0.0 Volume(cu ft/gal) 0.0 QuickAnalysis _0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor HERS 45 171109.pdf Quick Analysis Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Registry ID: Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Design Load (kBtu/hr) Heating 17.2 Cooling 10.3 Annual Load (MMBtu/yr) Heating 17.3 Cooling 4.6 Water Heating 7.4 Annual Consumption (MMBtu/yr) Heating 18.6 Cooling 1.2 Water Heating 7.8 Lights & Appliances 13.7 Photovoltaics -0.0 Total 41.3 Annual Energy Cost ($/yr) Heating 615 Cooling 50 Water Heating 256 Lights & Appliances 572 Photovoltaics -0 Service Charges 168 Total 1661 Total Area (sq ft) Conditioned Space 1240 Shell Area 3965 Above Grade Shell Area 3576 Foundation Wall 1336.0 Slab Floor 0 Floor 1240 Rim And Band Joist 166.8 Above-Grade Wall 1318.0 Window 144.3 Total Area (sq ft) Door 60.0 Ceiling 1240 Skylight 0.0 Duct 582.8 Ratios Window-to-Wall 0.132 Window-to-Floor 0.116 Window Area by Orientation (sq ft) North 0.0 Northeast 36.0 East 0.0 Southeast 36.0 South 0.0 Southwest 36.0 West 0.0 Northwest 36.3 Codes IECC 2015 Performance Passes IECC 2012 Performance Fails IECC 2009 Performance Fails IECC 2006 Performance Fails IECC 2004 Performance Fails IECC 2003 Performance Passes IECC 2001 Performance Passes IECC 1998 Performance Passes Iowa Code Fails Michigan Code Fails Illinois Code Passes ECC of NV Performance Passes NY-ECCC 2016 Performance Fails North Carolina Code Fails North Carolina HERO Fails Quick Analysis Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 Registry ID: Page 2 of 2 Projected Rating: Based on Plans - Field Confirmation Required. DRAFT Programs EPA ENERGY STAR 3.0 Fails EPA ENERGY STAR 3.0 Guam, Puerto Rico, Hawaii Fails EPA ENERGY STAR 3.1 Fails Tax Credit Fails DOE Zero Energy Ready Home Fails HERS Index 45 WH Infiltration Natural ACH 0.11 ACH50 (Pa) 2.75 CFM50 (Pa) 455 ELA (sq.in) 25.0 SLA 0.00014 CFM50/sf shell 0.11 WH Ventailation (continuous) Type Balanced AsIs (equiv. cfm) 60 62.2-2010 (cfm) 35 62.2-2013 (cfm) 60 IECCUA15 _0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor UA Cost 171109.pdf 2015 IECC Building UA Compliance Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Pomeroy Ter. Nhton 1st Floor Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 DRAFT REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. Elements Insulation Levels 2015 IECC As Designed Shell UA Check Above-Grade Walls: 78.0 59.6 Windows and Doors: 59.0 44.9 Floors Over Uncond Basement: 40.9 35.7 Overall UA (Design must be equal or lower): 177.9 140.2 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1.2) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 21.2%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 9 November 2017 2015 IECC Energy Cost Compliance Property Matthew Campagnari 1st Floor 9 Pomeroy Ter Northhampmton, MA 01060 Weather:Chicopee, MA Pomeroy Duplex 1st fl HERS_0073_0179_Matt C 9 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS Projected Rating 2017-03-22 Rating No:0073_179 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.4.2 This information does not constitute any warranty of energy cost or savings. © 1985-2017 Noresco, Boulder, Colorado. DRAFT Annual Energy Cost $/yr 2015 IECC As Designed Heating 1065 645 Cooling 91 84 Water Heating 621 604 SubTotal - Used to Determine Compliance 1776 1332 Lights & Appliances 579 572 Photovoltaics -0 -0 Service Charge 168 168 Total 2524 2072 Mandatory Requirements Annual Energy Cost Check PASSES Duct Insulation R-Value Check (per Section 405.2) PASSES Window U-Value and SHGC Check (per Section 402.5) PASSES Home Infiltration (Section 402.4.1) PASSES Duct Testing (Section 403.3.3) PASSES Mechanical Ventilation (Section 403.6) PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1) PASSES Mandatory Requirements Check Box (2015 IECC) PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. In fact, this home surpasses the requirements by 25.0%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 9 November 2017 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.