1016 SC Pub Safe ADSK02 add1 28Jan11Architects, Inc.
The architect shall be deemed the author of these documents and shall retain all common, statuatory and other reserved rights including the copyright. Any changes to these drawings without the written consent of the architect shall void the accuracy of the plans.
136 West Street, Northampton, MA
phone: (413) 585-0641 fax: (413) 582-9882
ISSUE:
SMITH COLLEGE
NORTHAMPTON, MASSACHUSETTS
SMITH COLLEGE PUBLIC
SAFETY RELOCATION
PROJECT
SMITH COLLEGE FACILITIES
MANAGEMENT
DATE:
THOMAS DOUGLAS
REF A-100 - Delete note to install Smith College provided shelving. Install adjustable shelving as
described. G.C. to re-use existing framing at storage bay wall. Modify as indicated on drawing. 1-hr
rating is not required for partition.
Addenda #1 01/28/2001
REVISED
BASEMENT
STORAGE PLAN
AD-SK-2
SAFE
EVIDENCE
B11A
PUBLIC SAFETY
AREA OF WORKSTORAGE
B11
ALIGN
MODIFY EXISTING WOOD STUD
WALL. REMOVE EXISTING CHICKEN
WIRE SCREENING. INFILL BAYS
WITH ADDITIONAL STUDS AS
REQUIRED. INSTALL ONE (1)
LAYER 1/2" PLYWOOD TO
INTERIOR SIDE OF STOREROOM.
COVER PLYWOOD WITH 5/8"
GWB. TAPE AND SAND JOINTS
FOR PAINTED FINISH.
FOAM SEAL AROUND ALL
PENETRATIONS, OPENINGS,
CRACKS AND GAPS AT WALL.
PROVIDE SEALANT AT HEAD AND
SILL OF WALL.
STORAGE SPACES TO BE
TEMPERATURE & HUMIDITY
CONTROLED TO PROTECT
DOCUMENTS AND EVIDENCE.
EQ EQ
±16'-10" VERIFY
NEW 3'0"X6'8" DOOR
WITH STORAGE ROOM
FUNCTION LEVER
HARDWARE
NEW, ADJUSTABLE SHELVING ON
HEAVY DUTY STANDARDS BY G.C.
AT PERIMETER OF ROOM AS
INDICATED. SHELF: 1X12 W/ 1X2
WOOD EDGE. PRIME & PAINT.
PROVIDE FOUR (4) SHELVES IN
6'-0" LONG SECTIONS.
STANDARDS TO BE 32"-48" O.C.
TO ALIGN WITH EXISTING STUDS.
STORAGE AT EVIDENCE CLOSET
BY COLLEGE
001
002
PROVIDE WEATHER STRIPPING &
DOOR SWEEP AT DOOR 001
ADDENDA #11/28/11ADDENDA #1
1/28/11
EXISTING PERIMETER
GWB WALLS TO BE
FINISH TAPED AND
PREP'D TO RECEIVE
PAINTED FINISH.
ADDENDA #1
1/28/11
ADDENDA #1
1/28/11