08110 Hollow Metal Frames add1 28Jan11Smith College Public Safety Relocation Project ISSUED FOR BIDDING 1/24/2011
Smith College Facilities Management ADDENDA #1, 1/28/2011
Smith College
Northampton, Massachusetts
STEEL DOORS AND FRAMES 08110 - 1
SECTION 08110 - STEEL DOORS AND FRAMES
1.1 GENERAL
A. Submit Product Data for each type of door and frame specified.
B. Quality Assurance: Comply with ANSI/SDI 100.
C. Fire-Rated Door Assemblies: NFPA 80, identical to assemblies tested per ASTM E 152, and
labeled and listed by UL, Warnock Hersey, or another testing and inspecting agency acceptable
to authorities having jurisdiction.
1.2 PRODUCTS
A. Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
1. Amweld Building Products, Inc.
2. Ceco Door Products.
3. Copco Door Co.
4. Curries Co.
5. Deansteel Manufacturing Co.
6. Fenestra Corp.
7. Mesker Door, Inc.
8. Pioneer Industries.
9. Republic Builders Products.
10. Steelcraft.
11. Philipp Manufacturing Co.
B. Hot-Rolled Steel Sheets: ASTM A 569 (ASTM A 569M).
C. Cold-Rolled Steel Sheets: ASTM A 366 (ASTM A 366M), commercial quality, or ASTM A 620
(ASTM A 620M), drawing quality.
D. Frames: Provide frames for doors, sidelights, borrowed lights, and other openings that comply
with ANSI/SDI 100; fabricate to be rigid, neat in appearance, and free from defects, warp, or
buckle.
1. For interior frames provide units with mitered or coped and continuously welded corners,
formed from 0.0478-inch- (1.2-mm-) thick cold-rolled steel for openings 48 inches (1220
mm) or less in width and from 0.0598-inch- (1.5-mm-) thick steel for openings over 48
inches (1220 mm) in width.
2. For interior frames provide units with mitered or coped corners knocked down for field
assembly, formed from 0.0478-inch- (1.2-mm-) thick cold-rolled steel for openings 48
inches (1220 mm) or less in width and from 0.0598-inch- (1.5-mm-) thick steel for
openings over 48 inches (1220 mm) in width.
3. Door Silencers: 3 on strike jambs of single-door frames and 2 on heads of double-door
frames.
E. Tolerances: Comply with SDI 117.
Smith College Public Safety Relocation Project ISSUED FOR BIDDING 1/24/2011
Smith College Facilities Management ADDENDA #1, 1/28/2011
Smith College
Northampton, Massachusetts
STEEL DOORS AND FRAMES 08110 - 2
F. Fabricate concealed stiffeners, reinforcement, edge channels, louvers, and moldings from either
cold- or hot-rolled steel sheet.
G. Hardware Preparation: Prepare doors and frames to receive mortised and concealed hardware
according to SDI 107.
H. Glazing Stops: Minimum 0.0359-inch- (0.9-mm-) thick steel or 0.040-inch- (1-mm-) thick
aluminum.
1. Provide nonremovable stops on outside of exterior doors and on secure side of interior
doors for glass, louvers, and other panels in doors.
2. Provide screw-applied, removable, glazing beads on inside of glass, louvers, and other
panels in doors.
I. Finishes, General: Comply with NAAMM's "Metal Finishes Manual" for recommendations
relative to applying and designating finishes.
1. Apply primers and organic finishes to doors and frames after fabrication.
J. Steel Sheet Finishes: Comply with SSPC-PA 1, "Paint Application Specification No. 1."
1. Surface Preparation: Solvent-clean surfaces according to SSPC-SP 1. Remove mill
scale and rust to comply with SSPC-SP 5 (White Metal Blast Cleaning) or SSPC-SP 8
(Pickling).
2. Pretreatment: Immediately after surface preparation, apply a conversion coating suited
to organic coating applied over it.
3. Factory Priming for Field-Painted Finish: Apply shop primer that complies with
ANSI A224.1 acceptance criteria, is compatible with finish paint systems indicated, and
has capability to provide a sound foundation for field-applied topcoats. Apply primer
immediately after surface preparation and pretreatment.
1.3 EXECUTION
A. General: Install steel doors, frames, and accessories according to Shop Drawings,
manufacturer's data, and as specified.
B. Placing Frames: Comply with provisions of SDI 105, unless otherwise indicated. Set frames
accurately in position, plumbed, aligned, and braced securely until permanent anchors are set.
1. Except for frames located in existing concrete, masonry, or gypsum board assembly
construction, place frames before constructing enclosing walls and ceilings.
2. Install at least 3 anchors per jamb adjacent to hinge location on hinge jamb and at
corresponding heights on strike jamb.
3. In in-place gypsum board partitions, install knock-down, slip-on, drywall frames.
4. Install fire-rated frames according to NFPA 80.
C. Door Installation: Fit hollow-metal doors accurately in frames, within clearances specified in
ANSI/SDI 100.
1. Fire-Rated Doors: Install with clearances specified in NFPA 80.
2. Smoke-Control Doors: Comply with NFPA 105.
Smith College Public Safety Relocation Project ISSUED FOR BIDDING 1/24/2011
Smith College Facilities Management ADDENDA #1, 1/28/2011
Smith College
Northampton, Massachusetts
STEEL DOORS AND FRAMES 08110 - 3
D. Prime Coat Touchup: Immediately after erection, sand smooth any rusted or damaged areas of
prime coat and apply touchup of compatible air-drying primer.
E. Protection Removal: Immediately before final inspection, remove protective wrappings from
doors and frames.
END OF SECTION 08110