CAPEN ANNEX RAMP plan 2016-01-11100.00
7'-6"7'-10" +/-6"6 3/4" +/-4'-1"3'-9"12" MIN.1'-0"1'-0"
(96.58)
(95.42)
96.50
8'-0"5'-0"
APPROXIMATE LINE OF
ADJACENT BUILDING
APPROXIMATE LINE OF
EXISTING EDGE OF
PAVEMENT
APPROXIMATE LINES OF
EXISTING PARKING
SPACES, ADJUST TO RIGHT
AS NEEDED TO ALLOW
FOR 5' WIDE STRIPED
ACCESSIBLE AISLE
PORCH
BOILER BUILDING
(96.42)
(96.25)
(95.75)
(96.58)(96.58)(97.08)
(96.33)
(95.42)
(95.33)
(95.50)(95.75)(95.33)
(97.33)
OAK
(96.25)
EXISTING LIGHT TO
REMAIN
OAK
100.00
23'-6" RAMP WITH RAILINGS
ACCESSIBLE (1:12 SLOPE)18'-6" RAMP WITH RAILINGSACCESSIBLE (1:12 SLOPE)98.88
96.25
5'-0"
1:20 SLOPE
IS LEADER STILL NEEDED?
7'-10"7'-10"7'-10"1'-0"
PROPOSED SITE PLAN
Scale: 1/8" = 1'-0"
1
0.1 CAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
SITE PLAN
0.1
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comCAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
SITE PLAN
0.1
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comPROGRESS
PRINT
NOT FOR
CONSTRUCTION
PERMIT SET - PHASE I: EXTERIOR RAMP
TUNNEL TO BOILER HOUSE
18'-6" RAMP WITH RAILINGSACCESSIBLE (1:12 SLOPE)5'-0"4'-0"23'-6" RAMP WITH RAILINGS14'-6"3'-6"7'-0"7'-0"6"4'-0"6"7'-10"7'-10"7'-10"4'-6" RAMPABOVE6"5'-0"PLATFORM4'-6" RAMP
ABOVE
6"
TYPICAL 12" SONO TUBE
RAMP FOUNDATION PLAN
Scale: 1/4" = 1'-0"
3
0.2
CAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP FNDN
PLAN
0.2
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comCAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP FNDN
PLAN
0.2
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comPROGRESS
PRINT
NOT FOR
CONSTRUCTION
PERMIT SET - PHASE I: EXTERIOR RAMP
TUNNEL TO BOILER HOUSE
18'-6" RAMP WITH RAILINGSACCESSIBLE (1:12 SLOPE)5'-0"4'-0"23'-6" RAMP WITH RAILINGS14'-6"3'-6"7'-0"7'-0"6"4'-0"6"7'-10"7'-10"7'-10"4'-6" RAMPABOVE6"5'-0"PLATFORM4'-6" RAMP
ABOVE
6"
TYPICAL 12" SONO TUBE
RAMP FRAMING PLAN
Scale: 1/4" = 1'-0"
1
0.3
CAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP FRAMING
PLAN
0.3
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comCAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP FRAMING
PLAN
0.3
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comPROGRESS
PRINT
NOT FOR
CONSTRUCTION
PERMIT SET - PHASE I: EXTERIOR RAMP
12" MIN.(96.58)
96.50
(96.42)
(96.25)
(95.75)
(96.58)(96.58)(97.08)
(96.33)(96.25)
BUILD NEW PLATFORM APPROXIMATELY
3" ABOVE EXISTING DECKING TO MATCH
HEIGHT OF INTERIOR FINISH FLOOR
REPLACE EXISTING WOOD THRESHOLD
WITH 1/2" HIGH ALUM. ONE
100.00
98.88
WIDEN DOOR AND REVERSE
SWING TO OPEN OUTWARD
2'-4" +/-4'-0"18'-6" RAMP WITH RAILINGSACCESSIBLE (1:12 SLOPE)96.25
5'-0"
PLATFORM5'-0"PLATFORM23'-6" RAMP WITH RAILINGS
ACCESSIBLE (1:12 SLOPE)EAST ELEVATIONSOUTH ELEVATION
7'-10"7'-10"7'-10"
CUT INTO EDGE OF DECK TO GET
FULL 4' SECTION OF RAMP RUN
OVER EXISTING DECK
1
0.6
3
0.6
2
0.6
1'-0"
12" RAIL EXTENSIONS
FINAL IRON POST ATTACHMENTS
TBD, CONSULT W/ ARCHITECT
DN
DN
RAMP PLAN
Scale: 1/4" = 1'-0"
1
0.4
CAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP PLAN
0.4
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comCAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP PLAN
0.4
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comPROGRESS
PRINT
NOT FOR
CONSTRUCTION
PERMIT SET - PHASE I: EXTERIOR RAMP
CAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP ELEVATIONS
0.5
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comCAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP ELEVATIONS
0.5
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comPROGRESS
PRINT
NOT FOR
CONSTRUCTION
PERMIT SET - PHASE I: EXTERIOR RAMP7'-0"
18'-6"RAMP WITH RAILINGS
ACCESSIBLE (1:12 SLOPE)
4'-0"
OVERLAP
5'-0"
PLATFORM
APPROX. LINE OF
SERVICE TUNNEL
EXISTING RAIL TO
REMAIN, ELEVATION
CUT TO SHOW NEW
HANDRAILS
4'-0"7'-0"6"6"
12"MIN RAIL EXTENSION
BEYOND END OF RAMP
FINAL IRON POST ATTACHMENT
INTO DECK
RAMP ELEVATION HIGHER SECTION
Scale: 1/4" = 1'-0"
1
0.5
5'-0"
PLATFORM
4'-0"6"
5'-0"23'-6" RAMP WITH RAILINGS
ACCESSIBLE (1:12 SLOPE)
7'-10"7'-10"7'-10"
12"MIN RAIL EXTENSION
BEYOND END OF RAMP
FINAL IRON POST ATTACHMENTS
TBD, CONSULT W/ ARCHITECT
RAMP ELEVATION LOWER SECTION
Scale: 1/4" = 1'-0"
3
0.5
CAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP DETAILS
0.6
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comCAPEN ANNEXSMITH COLLEGENORTHAMPTON, MAOCT. 15, 2015
RAMP DETAILS
0.6
REVISIONS:
DATENUMBER KRAUS-FITCHARCHITECTS, INC.HOME COMMUNITY PLANET110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comPROGRESS
PRINT
NOT FOR
CONSTRUCTION
PERMIT SET - PHASE I: EXTERIOR RAMP5'-11" +/-
EXISTING PORCH
NEW PLATFORM: TREX DECKING,
MATCH HEIGHT OF FINISH FLOOR
COVER EXISTING POST BASE AND
ADD NEW "COLLAR"INSTALLED
AROUND COLUMN BASE, SEALED
WITH CAULKING, PAINTED
EXISTING DECKING AND FRAME
NEW P.T. SLEEPERS, PITCHED @ 4'
RAMPED SECTION ABOVE PORCH
GRADE (VARIES)
4'-6" MIN. NEW RAMP
IN FRONT OF SECTION
SIDE PORCH SECTION
Scale: 1/2" = 1'-0"
1
0.6
38" MAX34" MIN20" MAX18" MIN4'-0" MINSECURE POST,
DETAIL TBD
TYPICAL 1-1/4"
TO 1 1/2" O.D.
HANDRAIL HELD
OUT MIN OF
1-1/2" FROM
SUPPORTS
3'-6"
4'-0" MIN.
CLEAR
RAMP SECTION @ YARD
Scale: 1/2" = 1'-0"
3
0.6 4'-0" MIN.NEW
12" DIA.
CONC.
PIER
RAMP PLATFORM,
HEIGHT VARIES
(PER SLOPE)
GRADE (VARIES)
EXISTING
LEDGER
BOARD
PAINTED BLOCKS
AT ATTACHMENT
POINTS
HANG NEW P.T.
LEDGER FROM
EXISTING
LEDGER
4'-0" MIN CLEAR1 1/2"
CLEAR
1 1/2"
CLEAR
P.T. BEAM, FLUSH
FRAMED OR BELOW
JOISTS PER
CONTRACTOR
PREFERENCE,
2" DIA. IRON POST,
BRACKET TO SECURE
TO FRAMING
P.T. POST AS REQ'D BY
GRADE CHANGE
1 1/2" DIAM. RAIL 1 1/2" DIAM. RAIL
RAMP SECTION @ BUILDING
Scale: 1/2" = 1'-0"
2
0.6