Loading...
P15687 25 Mark Warner Dr Florence Energy Efficiency Plan ENERGY EFFICIENCY PLAN Project Address: 25 Mark Warner Drive, Florence, MA Conditioned Floor Area 2,110 ft2 (no basement area included) Volume 17,855 ft3 Building Type Single family detached Bedrooms 2 Assumptions for Preliminary Home Energy Rating CET has completed a Preliminary Home Energy Rating based on the construction plans you have provided. Any energy features not listed below are assumed to meet the prescriptive requirements of the IECC 2009. Building Envelope Specifications Used in Analysis Foundation Walls Uninsulated Basement Slab Uninsulated Floor over Unconditioned Basement R-30 Fiberglass Batts, held in contact with subfloor Band Joists R-21 Fiberglass Batts Exterior Walls, including to garage and to attics R-21 Fiberglass Batts, all cavities fully enclosed by air barrier on top & both sides (including sheathing & top plates at attic kneewalls) Windows & Glass Doors U-value = 0.30 SHGC = 0.27 (predominant values) Exterior Doors (opaque) R-5 / U-0.20 Flat Ceilings Upper Attic: 13” loose-blown cellulose (R-48), sealed eave wind baffles, full insulation contact with sheetrock ceiling Lower attics: R-38 fiberglass batts in joist cavities, sealed eave wind baffles, full insulation contact with sheetrock ceiling Vaulted Ceilings Vaulted: R-38 fiberglass batts, sealed eave wind baffles, Full insulation contact with sheetrock ceiling Attic Hatches Attic Hatches over conditioned space: R-10+ Foamboard, fully gasketed, framed edge dam to height of surrounding insulation Blower Door Test 3.0 ACH50 or better Thermal Enclosure Checklist, sections 2&4 Meet all Checklist Requirements as verified by a HERS rater at pre- drywall and final inspection Mechanical Systems Specifications Used in Analysis Heating Equipment 96.0 AFUE natural gas furnace Cooling Equipment 14.5 SEER air conditioning, TXV or EXV valve included, properly sized and documented on Mass Save HVAC Contractor Checklist Water Heating Equipment 0.67 Energy Factor natural gas-fired tank Duct Leakage <6 CFM25 leakage to outdoors per 100 sq ft of finished floor area (<126.6 CFM25); all ductwork thoroughly sealed. All boots and chases to unconditioned space sealed to sheetrock/subfloor. Duct Location & Insulation 45% Unconditioned Attic R-8; 50% Unconditioned Basement R-6; 5% Conditioned Space R-0 Whole House Ventilation Continuously operating, variable speed bath exhaust fan<1.0 sones, Energy Star, 44+ CFM continuous ENERGY EFFICIENCY PLAN Page 2 of 2 ~ Please send signed form to the Center for EcoTechnology Tel (413) 586-7350 ext.242 ~ Fax (413) 586-7351 ~ greenhome@cetonline.org Lighting & Appliances Specifications Used in Analysis Lighting 80% LED, CFL, or pin-based fluorescent Refrigerator ENERGY STAR certified recommended Dishwasher ENERGY STAR certified recommended Preliminary Home Energy Rating Results Based on the assumptions described above, we have calculated the following Preliminary Home Energy Rating results. Preliminary HERS Index: 67 Preliminary Improvement Over 2016 Mass. Reference Home v2: 17.0% - Tier I* Note that Confirmed Home Energy Rating results may vary from the Preliminary Home Energy Rating results due to changes in building plans, energy features installed in the home, RESNET standards, software changes, and other factors. * = Mass Save Residential New Construction requirements and incentive amounts can change at any time without notice at the discretion of program sponsors. We expect significant changes to the rebate amounts to occur in late 2016 and/or early 2017. Preliminary Rater: John Saveson Date: 8/5/2016 Job #: P15687