CS 1st floor Girder CalcsCS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 FerrariBishopGorman - Level 6 2- 6-17 1:15pm 1 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/480 live, L/360 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.2 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 8.63" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 20' 3.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 20' 3.50" 67 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 20' 3.50" 36 166 Live Replacement Uniform (PLF) Top 4' 8.63" 20' 3.50" 27 7 Live Point (LBS) Top 0' 4.38" 4283 1082 Live Point (LBS) Top 19' 11.13" 5055 0 Snow Point (LBS) Top 19' 11.13" 4096 3364 Live 1 2 20 3 8 20 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 3.573" 8128# -- 2 20' 3.500" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 5.830" 13264# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 5155# 656# 2972# 2 4968# 5711# 5254# Design spans 19' 6.750" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Minimum 5.83" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 13511.'# 29034.'# 46% 10.15' Total Load D+L Shear 2433.# 9310.# 26% 0.37' Total Load D+L TL Deflection 0.6391" 0.6521" L/367 10.15' Total Load D+0.75(L+S) LL Deflection 0.2413" 0.4891" L/973 10.15' Total Load 0.75(L+S) Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 FerrariBishopGorman - Level 6 2- 6-17 1:15pm 2 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG15 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/480 live, L/360 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 24.3 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 0.00" 400 100 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 3.00" 120 30 Live Replacement Uniform (PLF) Top 4' 0.00" 16' 0.00" 400 100 Live Replacement Uniform (PLF) Top 16' 0.00" 17' 3.25" 400 100 Live Point (LBS) Top 0' 3.50" 2998 655 Live Point (LBS) Top 4' 1.25" 0 42 Live Point (LBS) Top 17' 1.13" 10648 3018 Live 1 2 17 3 4 17 3 4 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Girder SPF #3/Stud 2x or 4x End-Grain (650psi) N/A N/A 8613# -- 2 17' 3.250" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 5.319" 18150# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 6777# 1836# 2 14064# 4086# Design spans 16' 9.625" Product: 1-3/4x16 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Minimum 5.32" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 19170.'# 58288.'# 32% 8.69' Total Load D+L Shear 4062.# 15960.# 25% 0.3' Total Load D+L TL Deflection 0.2732" 0.5601" L/737 8.69' Total Load D+L LL Deflection 0.2078" 0.4201" L/970 8.69' Total Load L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 FerrariBishopGorman - Level 6 2- 6-17 1:15pm 3 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG17 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/480 live, L/360 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.6 PLF Filename: C:\KMW\JOBS\ Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 4' 6.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 6.00" 36 9 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 6.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 10' 6.00" 55 153 Snow Replacement Uniform (PLF) Top 4' 6.00" 5' 6.00" 27 7 Live Replacement Uniform (PLF) Top 5' 6.00" 10' 6.00" 27 7 Live Point (LBS) Top 0' 4.63" 1 196 Live Point (LBS) Top 0' 4.63" 408 0 Snow Point (LBS) Top 4' 6.00" 6833 1764 Live Point (LBS) Top 10' 1.38" 0 45 Live Point (LBS) Top 10' 1.38" 35 10 Snow Point (LBS) Top 10' 1.38" 0 93 Live Point (LBS) Top 10' 1.38" 141 0 Snow Point (LBS) Top 10' 1.38" 0 162 Live Point (LBS) Top 10' 1.38" 149 210 Live Point (LBS) Top 10' 1.38" 561 0 Snow 1 2 3 4 6 0 6 0 0 10 6 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 1.500" 950# -- 2 4' 6.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 4.453" 10130# -- 3 10' 6.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) N/A 1.500" 1784# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 165# 510# 440# 2 7251# 343# 2879# 3 277# 871# 913# Design spans 4' 1.375" 5' 7.375" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 594.'# 13958.'# 4% 7.87' Even Spans D+L Negative Moment 768.'# 13958.'# 5% 4.5' Total Load D+L Shear 600.# 6317.# 9% 4.51' Total Load D+L TL Deflection 0.0065" 0.1872" L/999+ 7.59' Even Spans D+0.75(L+S) LL Deflection 0.0024" 0.1404" L/999+ 7.59' Even Spans 0.75(L+S) CS Structure™ 2016.11 [Build 16] kmBeamEngine 2016.9.0.3 Materials Database 1557 FerrariBishopGorman - Level 6 2- 6-17 1:15pm 4 of 4 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives