Furnace specRheem Value Series Upflow Gas Furnace FORM NO. G11-534 RGRS/RGRT- Series Up to 93.5% A.F.U.E.† Input Rates 45-120 kBTU ✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. • The Rheem Value Series High Efficiency line of upflow gas furnaces are designed for utility rooms, closets, or alcoves. Because of the low-profile 34 inch height, this model can be used vertically to satisfy most applications that traditionally call for a horizontal furnace. • The design is certified by CSA. • Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories. • Left or right side gas, electric, and condensate drainage connections on upflow models. • Integrated control board manages all operational functions and provides accessory hookups for an electronic air cleaner. • A slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. • Pre-paint galvanized steel cabinet. • Optional indoor or outdoor combustion air. In addition, combustion air may be piped to either the top or right side of the cabinet on all upflow models. A special molded fitting is provided to ease installation. • Control board diagnostics. • A variety of cooling coils and plenums designed to use with the Rheem Value Series gas furnaces are available as optional accessories for air conditioning models. Air Gas Furnaces RGRS/RGRT Series Annual Fuel Utilization Efficiency - AFUE THIS MODEL ENER UIDE 97%78%HIGHMID82% 88% 92.0% Air Table of Contents RGRS/RGRT Series 2 TABLE OF CONTENTS Standard & Optional Equipment ......................................................................3 Model Features/Physical Data & Specifications..................................................4 Model Number Identification ............................................................................5 Dimensional Data............................................................................................6 Blower Performance Data................................................................................7 Accessories ................................................................................................8-9 Limited Warranty ..........................................................................................10 Air Standard & Optional Equipment RGRS/RGRT Series 3 STANDARD EQUIPMENT Completely assembled and wired; heat exchanger; primary: aluminized steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; pressure regulator for natural and L.P. (propane) gases; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.) OPTIONAL EQUIPMENT (See Accessory Page) NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES PRIMARY AND SECONDARY HEAT EXCHANGER GAS VALVE AND MANIFOLD DIRECT SPARK IGNITION & REMOTE SENSOR IN-SHOT BURNERS PRESSURE SWITCHES DRAFT INDUCER INTEGRATED FURNACE CONTROL REMOTE SENSOR MODEL NUMBERS RGRS/RGRT- SERIES RGRS-04EMAES RGRS-06EMAES RGRT-07EMAES RGRT-07EYBGS RGRS-09EZAGS RGRS-10EZAJS Input-BTU/Hr [kW] ➀45,000 [13.19] 60,000 [17.58] 75,000 [21.98] 75,000 [21.98] 90,000 [26.37] 105,000 [30.77] Heating Capacity BTU/Hr [kW] 42,000 [12.31] 56,000 [16.41] 70,000 [20.51] 70,000 [20.51] 84,000 [24.61] 97,000 [28.43] High Altitude Input [kW] ➁ 40,500 [11.87] 54,000 [15.83] 67,500 [19.78] 67,500 [19.78] 81,000 [23.73] 94,500 [27.70] High Altitude Output Capacity [kW] ➁ 37,800 [11.07] 50,400 [14.77] 63,000 [18.46] 63,000 [18.46] 76,000 [22.27] 87,500 [25.64] Blower (D x W) [mm] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 12 x 7 [305 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279] Motor H.P. [W] Speeds-Type 1/2 [373] 4-PSC 1/2 [373] 3-PSC 1/2 [373] 3-PSC 3/4 [559] 3-PSC 1/2 [373] 3-PSC 3/4 [559] 3-PSC Motor Full Load Amps 6.8 6.8 6.8 9.5 8.0 9.5 Heating Speed Med-Low Low Med Low Med Low Cooling Speed High High High High High High RGRS-09EZAJS 90,000 [26.37] 84,000 [24.61] 81,000 [23.73] 76,000 [22.27] 12 x 11 [305 x 279] 3/4 [559] 3-PSC 93.5% 160 [72.6] 50-80[27.8-44.4] Heat Ext. Static Pressure (In. W.C.) [kPa].10 [.025].12 [.029].12 [.029].12 [.029].15 [.037].20 [.049] Rated Ext. Static Pressure (In. W.C.) [kPa].50 [.12].50 [.12].50 [.12].50 [.12].50 [.12].50 [.12] Heating C.F.M. @ .2" [.049 kPa] W.C. E.S.P. [L/s]885 [417]845 [398]1050 [495]1275 [600]1465 [691]1445 [682] 1900 [897] 1580 [745] .50 [.12] .20 [.049] High Low 9.5 3/4 [559] 3-PSC 11 x 10 [279 x 254] 100,000 [29.31] Cooling C.F.M. @ .5" [.124 kPa]W.C. E.S.P. [L/s]1195 [564]1100 [519]1110 [524]1540 [725]1580 [746]1810 [854] Temperature RiseRange °F [°C]30-60[16.7-33.3]40-70[22.2-38.9]45-75[25-41.7]40-70[22.2-38.9]35-65 [19.4-36.1]50-80[27.8-44.4] Approx. Shipping Weight (Lbs.) [kg]111 [50.3]117 [53.1]123 [55.8]123 [55.8]148 [67.1]152 [68.9] AFUE ➂93.5%92.5%92.8%92.0%93.5%92.0% 9.5 Low High .15 [.037] .50 [.12] 1465 [691] 108,000 [31.65] 1910 [901] 35-65[19.4-36.1] 148 [67.1] 93.5% 113,000 [33.12] 120,000 [35.17] RGRS-12ERAJS C24B(2) 24" x 16" [609 x 406] Return Air Cabinets (Opt.) RXGR-Filter Size [mm] C17B(2) 12" x 16" [305 x 406] C17B(2) 12" x 16" [305 x 406] C17B(2) 12" x 16" [305 x 406] C21B(2) 12" x 20" [305 x 508] C21B(2) 12" x 16" [305 x 406] C21B(2) 12" x 16" [305 x 406] C21B(2) 12" x 16" [305 x 406] 87.57%California Seasonal Efficiency ➂84.68%86.44%87.16%85.16%85.96%86.93%85.96% Air Model Features/Physical Data & Specifications RGRS/RGRT Series 4 Physical Data and Specifications—Upflow Models U.S. and Canadian Models NOTES: All models are 115V, 60HZ, 1Ø. Gas connection size for all models is 1/2" [13 mm] N.P.T. ➀See Conversion Kit Index Form for high altitude derate. ➁Canadian installations only. ➂In accordance with D.O.E. test procedures. [ ] Designates Metric Conversions • The design is certified by CSA. • Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories. • Left or right side gas, electric, and condensate drainage connections on upflow models. • Integrated control board manages all operational functions and provides accessory hookups for an electronic air cleaner. • A slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. • Pre-paint galvanized steel cabinet. • Optional indoor or outdoor combustion air. In addition, combustion air may be piped to either the top or right side of the cabinet on all upflow models. A special molded fitting is provided to ease installation. • Control board diagnostics. Model Features Air Model Number Identification RGRS/RGRT Series 5 Model Number Identification EM04ESRR Heating & Cooling Designation (Nominal) E = 1100-1300(3R) G = 1500-1700(4R) J = 1900-2100(5R) Blower Designation [mm] M = 11 x 7 [279 x 178] R = 11 x 10 [279 x 254] Y = 12 x 7 [305 x 178] Z = 12 x 11 [305 x 279] Heating Input DesignationDesign Series S = 3rd Design Series T = 4th Design Series R = Upflow Condensing R H E E M Electric Ignition 04E 06E 07E 09E 10E 12E Input BTU/HR [kW] 45,000 [13.1] 60,000 [17.6] 75,000 [21.9] 90,000 [26.4] 105,000 [30.7] 120,000 [35.2] G Gas Furnace A Variations A = Std. B = Wide Cabinet S Fuel Designation S = Natural Gas - CSA - United States & Canada (North American) — [ ] Designates Metric Conversions Air Dimensional Data RGRS/RGRT Series 6 Upflow Models MODEL RGRS/RGRT-A B C D E F LEFT SIDE MINIMUM CLEARANCE (IN.) [mm]SHIP WGTS. [kg]RIGHT SIDE BACK TOP FRONT VENT 04 171/2 [445]1611/32 [415]155/8 [397]2 [51]15 [422]1325/32 [352]0 0 0 1 [25]2 [51]0 111 [50] 06 171/2 [445]1611/32 [415]155/8 [397]2 [51]15 [422]1325/32 [352]0 0 0 1 [25]2 [51]0 117 [53] 07EM 171/2 [445]1611/32 [415]155/8 [397]2 [51]15 [422]1325/32 [352]0 0 0 1 [25]2 [51]0 123 [56] 07EY 21 [533]1927/32 [504]191/8 [487]2 [51]181/2 [511]179/32 [441]0 0 0 1 [25]2 [51]0 123 [56] 09 21 [533]1927/32 [504]191/8 [487]2 [51]181/2 [511]179/32 [441]0 0 0 1 [25]2 [51]0 148 [67] 10 21 [533]1927/32 [504]191/8 [487]2 [51]181/2 [511]179/32 [441]0 0 0 1 [25]2 [51]0 152 [69] 12 241/2 [622]2311/32 [593]225/8 [575]2 [51]22 [600]2025/32 [530]0 0 0 1 [25]2 [51]0 160 [73] [ ] Designates Metric Conversions MODEL NUMBER BLOWER SIZE [mm] MOTOR H.P. [W] BLOWER SPEED CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa] RGRS-09EZAGS 12 x 11 [305 x 279] 1/2 [373] LOW MED HIGH 1235 [582] 1490 [703] 1720 [811] 1210 [571] 1465 [691] 1670 [788] 1180 [559] 1445 [679] 1620 [764] 1150 [543] 1405 [663] 1600 [755] 1120 [528] 1375 [649] 1580 [746] 1075 [507] 1315 [620] 1520 [717] 0.1 [.02]0.2 [.05]0.3 [.07]0.4 [.10]0.5 [.12]0.6 [.15]0.7 [.17] RGRS-04EMAES 11 x 7 [279 x 178] 1/2 [373] LOW MED-LO MED-HI HIGH 805 [380] 920 [434] 1140 [538] 1360 [642] 780 [368] 885 [417] 1110 [524] 1320 [623] 760 [358] 850 [401] 1085 [512] 1280 [604] 720 [340] 810 [382] 1045 [493] 1235 [583] 685 [323] 775 [365] 1010 [476] 1195 [564] 645 [304] 730 [344] 950 [448] 1140 [538] 605 [285] 690 [325] 890 [420] 1080 [500] RGRS-06EMAES 11 x 7 [279 x 178] 1/2 [373] LOW MED HIGH 880 [415] 1060 [500] 1260 [594] 845 [398] 1025 [483] 1215 [573] 815 [384] 990 [467] 1175 [554] 790 [373] 960 [453] 1135 [535] 760 [358] 925 [436] 1100 [519] 715 [337] 880 [415] 1040 [491] 670 [316] 835 [394] 985 [465] RGRT-07EMAES 11 x 7 [279 x 178] 1/2 [373] LOW MED HIGH 880 [415] 1090 [514] 1300 [613] 850 [401] 1050 [495] 1255 [592] 825 [389] 1010 [477] 1210 [571] 785 [370] 970 [458] 1160 [547] 750 [354] 925 [436] 1110 [524] 702 [331] 875 [413] 1055 [498] 655 [309] 825 [389] 1005 [474] 1035 [488] 1255 [592] 1460 [689] RGRS-12ERAJS 11 x 10 [279 x 245] 3/4 [559] LOW MED HIGH 1610 [760] 1870 [882] 2115 [998] 1580 [746] 1820 [860] 2050 [967] 1555 [734] 1775 [838] 1990 [939] 1515 [715] 1715 [809] 1945 [917] 1475 [696] 1660 [783] 1900 [897] 1415 [668] 1590 [750] 1795 [847] RGRT-07EYBGS 12 x 7 [305 x 178] 3/4 [559] LOW MED HIGH 1290 [609] 1480 [698] 1705 [805] 1275 [602] 1435 [677] 1665 [786] 1280 [696] 1415 [668] 1615 [762] 1220 [576] 1390 [656] 1570 [741] 1195 [564] 1370 [647] 1540 [727] 1170 [552] 1300 [614] 1475 [696] 1140 [538] 1255 [592] 1400 [661] 1355 [639] 1520 [717] 1690 [795] RGRS-09EZAJS 12 x 11 [305 x 279] 3/4 [559] LOW MED HIGH 1490 [703] 1720 [811] 2100 [991] 1465 [691] 1670 [788] 2050 [967] 1445 [679] 1620 [764] 2000 [944] 1405 [663] 1600 [755] 1955 [923] 1375 [649] 1580 [746] 1910 [901] 1315 [620] 1520 [717] 1825 [861] 1255 [592] 1460 [689] 1745 [823] RGRS-10EZAJS 12 x 11 [305 x 279] 3/4 [559] LOW MED HIGH 1490 [703] 1710 [807] 2010 [949] 1445 [682] 1665 [786] 1955 [923] 1405 [663] 1620 [764] 1900 [897] 1375 [649] 1580 [746] 1855 [875] 1350 [637] 1540 [727] 1810 [854] 1295 [611] 1475 [696] 1710 [807] 1240 [585] 1410 [665] 1610 [859] Air Blower Performance Data RGRS/RGRT Series 7 [ ] Designates Metric Conversions Blower Performance Data—RGRS/RGRT- Models Air Accessories RGRS/RGRT Series 8 UPFLOW ACCESSORIES FILTER RACK FILTER SIZES* INCHES [mm] 10 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 12 MODEL RGRS/RGRT- RXGF-CB (BOTTOM) RXGF-CA (SIDE) 223/4 x 25 [578 x 635] 153/4 x 25 [400 x 635] 04 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 06 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 07EE 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 07EF 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 09 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] FURNACE WIDTH IN. [mm] PLENUM WIDTH IN. [mm] PLENUM ADAPTER UPFLOW COIL PLENUM 141/2 [356]161/4 [413]RXAA-C171 RXAL-B16BU 141/2 [356]201/4 [514]RXAA-C172 RXAL-B20BU 171/2 [445]161/4 [413]RXAA-C185 RXAL-B16BU 171/2 [445]201/4 [514]RXAA-C173 RXAL-B20BU 171/2 [445]215/8 [549]RXAA-C187 RXAL-B21BU 171/2 [445]251/4 [641]RXAA-C174 RXAL-B25BU 211/2 [533]251/4 [641]RXAA-C175 RXAL-B25BU 211/2 [533]221/4 [565]RXAA-C176 RXAL-B22BU 241/2 [622]251/4 [641]RXAA-C177 RXAL-B25BU 241/2 [622]215/8 [549]RXAA-C187 RXAL-B21BU 211/2 [533]215/8 [549]RXAA-C188 RXAL-B21BU PLENUM DATA FOR “A” COILS Plenum adapters are required in some instances for use on upflow applications when plenum and furnace size do not match. VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/VERTICAL = RXGY-E03A (US & Canadian Installations) HORIZONTAL TWO PIPE:RXGY-D02, RXGY-D03, RXGY-D04 (US Installations) RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations) RXGY-G02 (US Only) NEUTRALIZER KIT:RXGY-A01 FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA) RETURN AIR PLENUM:RXGR-C17B RXGR-C21B RXGR-C24B EXTERNAL BOTTOM FILTER RACK:RXGF-CB EXTERNAL SIDE FILTER RACK:RXGF-CA *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. INTERNAL FILTER RACK FOR BOTTOM OR SIDE RETURN:RXGF-DA* Each order contains (1) one box of 10 filter racks supplied without filters. *Filters available through PROSTOCK®. RXGP-F03 TWINNING KIT—is for use with Rheem Value Series 90 Gas Furnaces for parallel operation requirements. WARNING: IMPORTANT NOTICE A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE OR REAR AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS. SOLID BOTTOM IS AVAILABLE FACTORY INSTALLED WITH OPTION CODE 263. FURNACE BASE WIDTH SOLID BOTTOM BASE PLATE SIZE IN. [mm]KIT NO. PLATE NO.IN. [mm] 171/2 [445] RXGB-D17 AE-61874-02 151/8 x 239/16 [384 x 598] 21 [533] RXGB-D21 AE-61874-03 185/8 x 239/16 [473 x 598] 241/2 [622] RXGB-D24 AE-61874-04 255/8 x 239/16 [651 x 598] FOR HIGH ALTITUDES: *HIGH ALTITUDE KIT: RXGY-F04 (105 KBTU/H) RXGY-F05 (120 KBTU/H) RXGY-F06 (45 KBTU/H/60 KBTU/H/90 KBTU/H) RXGY-F07 (75 KBTU/H) *For installations over 5000 ft. OPTION CODE FOR HIGH ALTITUDE:US & Canada – 278 NOTE:High altitude kits and options do NOT include additional burner orifices. If a burner orifice change is necessary, they must be ordered through PROSTOCK®. See Installation Instructions for more information. Option – 278 furnaces are shipped with #51 DMS orifices installed. This is one drill size smaller than standard furnaces to account for expected average elevations and heating values typically seen in these areas. CAUTION:Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. For all installations above 2000 ft. (including all option – 278 models), the burner orifice size needs to be recalculated and verified. A burner orifice change may still be required. See Installation Instructions for more information. NOTE:For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. [ ] Designates Metric Conversions Air Accessories RGRS/RGRT Series 9 * Photos are representative. Actual models may vary. For detailed thermostat match-up information, see specification sheet form number T11-001. 300-Series * Deluxe Programmable 400-Series * Special Applications/ Programmable 500-Series * Communicating/ Programmable 200-Series * Programmable Thermostats Air Limited Warranty RGRS/RGRT Series 10 GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Heat Exchanger ..........................................Twenty (20) Years Conditional Parts (Registration Required) ........Ten (10) Years Air Notes RGRS/RGRT Series 11 The new degree of comfort.™ Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. PRINTED IN U.S.A 05/12 QG FORM NO. G11-534 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5