055-12 53 Emerson Way duct test #230 West Pomeroy Lane Amherst, MA 01002 Phone: 413-835-5162 Email: matt.turcotte@gmail.com Date Of Test: 2/22/2013 Client Countryside Home Builders Site Address: 53 Emerson Way Northampton, MA 01062 Test Performed By: Matt Turcotte Job #: 055-12 Type of Test Performed: Post-Construction, leakage to outside (8%) Duct System 1 Conditioned Floor Area: 1075 sq ft Duct Flow at 25 Pa: 62 CFM Duct Leakage: 5.77 CFM per 100 sq ft of conditioned floor area TEST RESULT : PASS Duct System 2 (if applicable) Conditioned Floor Area: 1252 sq ft Duct Flow at 25 Pa: 71 CFM Duct Leakage: 5.67 CFM per 100 sq ft of conditioned floor area TEST RESULT: PASS Notes on Area Tested and/or Testing Conditions: 2009 IECC Minimum Requirements, per Section 403.2.2 Post-Construction Test, leakage to the outdoors < 8 CFM per 100 sq ft of conditioned floor area Post-Construction Test, total leakage < 12 CFM per 100 sq ft of conditioned floor area Mid-Construction Test, total leakage without air handler < 4 CFM per 100 sq ft of conditioned floor area Site Information Duct Pressurization Test Results Mid-Construction Test, total leakage with air handler < 6 CFM per 100 sq ft of conditioned floor area