Loading...
CDH Pharmacy Drawings EL2.pdf P2.pdf MEP1.2.pdf HD1A.pdf FPD1.pdf MEP1.1.pdf H3.1.pdf PD1.pdf E3.1.pdf CDH_201031_Pharmacy_Arch CD Dwgs 4-11-14_Stamped.pdfF:\CDH_201031_Cancer Ctr\Pharmacy\CDH_201031_Pharmacy_kmcintosh.pdf ARCHITECT: CONSULTANT: 50 Griffin Road South Bloomfield, CT 06002 t: 806-286-9171 Consultant Address City, State Zip Telephone CONTRACTOR NAME CONTRACTOR: © MorrisSwitzer~Environments for Health, Inc. 11 Drydock Ave., Suite 2060 Boston, MA 02210 t: 617.772.0260 f: 617.772.0261 www.morrisswitzer.com Tel: (860) 286-9171 Fax: (860) 242-0236 50 Griffin Road South Bloomfield, CT 06002 services integrated 4/14/2014 11:54:16 AM PHARMACY RENOVATION 4/11/14 PROJECT #201031 COOLEY DICKINSON HOSPITAL AG-1 ARCHITECTURAL STANDARD GRAPHICS A1 FIRST FLOOR DEMOLITION PLAN AND PART PLANS A2 FIRST FLOOR REFERENCE PLAN AND PART GROUND FLOOR PLAN A3 ENLARGED FIRST FLOOR PLAN AND REFLECTED CEILING PLAN A4 EXTERIOR ELEVATIONS AND DETAILS A5 INTERIOR ELEVATIONS A6 PARTITION TYPES AND DETAILS A7 DOOR SCHEDULE, ROOM FINISH SCHEDULE AND DETAILS A8 MILLWORK DETAILS LIST OF DRAWINGS: ARCHITECTURAL MEP1.1 MEP GENERAL NOTES AND ABBREVIATIONS MEP1.2 MEP SYMBOL LIST MEP2.1 MEP DETAILS MEP2.2 MEP DETAILS MEP3.1 MEP SCHEDULES MEP3.2 MEP SCHEDULES FPD1 FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN FP2 FIRST FLOOR FIRE PROTECTION PLAN FP3.1 FIRE PROTECTION DETAILS PD1 FIRST FLOOR PLUMBING DEMOLITION PLAN P2 FIRST FLOOR PLUMBING PLAN P3.1 PLUMBING DETAILS HD1 FIRST FLOOR HVAC DEMOLITION PLAN HD1A ALTERNATE FIRST FLOOR HVAC DEMOLITION PLAN H2 FIRST FLOOR HVAC DUCTWORK PLAN H2A ALTERNATE FIRST FLOOR HVAC DUCTWORK PLAN HP2 FIRST FLOOR HVAC PIPING PLAN HP2A ALTERNATE FIRST FLOOR HVAC PIPING PLAN H3.1 HVAC DETAILS ED1 FIRST FLOOR ELECTRICAL DEMOLITION PLAN EL2 FIRST FLOOR ELECTRICAL LIGHTING PLAN EPS2 FIRST FLOOR ELECTRICAL POWER AND SPECIAL SYSTEMS PLAN E3.1 ELECTRICAL DETAILS ENGINEERING ISSUED FOR CONSTRUCTION 2 12 CLG HT (FFL) CEILING HT. SYMBOL FINISH FLOOR HT FLOOR TRANSITION SYMBOL NUMBER TRANSITION DETAIL 12 TAG FURNITURE TAG/ REVISION SYMBOL BATHROOM ACCESSORY FINISH SYMBOL (WALL & BASE) 3 PT-18 (FLOOR & CEILING) FINISH SYMBOL BC30 BC CASEWORK KEY ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS MATERIAL LEGEND PLAN VIEW ELEVATION ELECTRICAL AND MEDICAL GAS SYMBOLS 5. CABINETS TO BE PROVIDED WITH ADJUSTABLE SHELVES AS FOLLOWS, UON: 13. ALL BASE CABINETS DIRECTLY BELOW SINKS SHALL HAVE LOCKS. 11. CUSTOM MILLWORK TO BE AS DIMENSIONED AS INDICATED ON SPECIFIC ELEVATIONS. 12. PROVIDE A WALL STOP WHEREVER A TALL STORAGE UNIT DOOR PULL IMPACTS AN ADJACENT WALL CABINETS: 1 SHELF (LESS THAN 24" H) 7. ALL DRAWERS IN BASE CABINETS TO BE 6" IN HEIGHT UNLESS OTHERWISE NOTED. 8. AT KNEE SPACES, THE COUNTERTOP SHALL BE PROVIDED WITH A PLASTIC LAMINATE APRON WHEREVER PENCIL DRAWERS DO NOT OCCUR. HEIGHT OF APRON TO COORDINATE WITH PENCIL DRAWER HEIGHT OR DRAWER IN ADJACENT CABINET AS SHOWN ON MILLWORK ELEVATION. ALL STORAGE UNITS TO BE 7'-2" TALL UNLESS OTHERWISE NOTED. 10. WALL CABINET BULKHEADS TO BE OF GWB/STUD CONSTRUCTION UNLESS OTHERWISE NOTED. 9. TOP OF WALL CABINETS TO BE MOUNTED AT 7'-2" AFF UNLESS OTHERWISE SHOWN. TALL 6. TYPICAL SINK COUNTERTOP TO BE SOLID SURFACE. DEPTH TO BE 24" MIN WITH SOLID SURFACE BACKSPLASH UNLESS OTHERWISE NOTED GWB FINISH WHEN OPENED. APRONS TO BE REMOVABLE. TALL STORAGE: 5 SHELVES SINK BASE: NO SHELVES WALL CABINETS: 2 SHELVES (24"-36" H) SEE INTERIOR ELEVATIONS FOR LOCATIONS BASE CABINETS: 1 SHELF 1. PENCIL DRAWERS WHERE SHOWN SHALL BE 3" IN HEIGHT AND A MAXIMUM WIDTH OF 24". ALL 2. CABINET UNIT DEPTHS TO BE AS FOLLOWS, UON ON DETAILS: (EXCLUDING DOORS) 4. END PANELS: SEE MILLWORK DETAILS PENCIL DRAWERS TO BE REMOVABLE. 3. TYPICAL TOE SPACE AT FLOOR MOUNTED CABINETS: HEIGHT: 4" TALL STORAGE CABINETS: 24" WALL CABINETS: 15" MIN. BASE CABINETS: 22" Note: Electrical and medical gas device symbols, where shown on architectural drawings, are for the specific design and location requirements and are intended to supplement plumbing and electrical drawings for coordination and layout. The plumbing and electrical drawings take precedence for quantity, bidding and construction. Architectural drawings take precedence for location. CABINET HEIGHT: FINISHED FLOOR TO TOP OF COUNTERTOP 34" U.O.N. REFER TO INTERIOR ELEVATIONS WIDTH IN INCHES DENOTES CABINET UNIT PREFIX DENOTES CABINET TYPE BASE CABINETS GENERAL NOTES: BASE CABINETS WALL CABINETS CABINET HEIGHT: SEE INTERIOR ELEVATIONS FOR HEIGHT COUNTERTOP, SEE GENERAL NOTES CODE SYSTEM WIDTH IN INCHES DENOTES CABINET UNIT PREFIX DENOTES CABINET TYPE WALL CABINETS BB WC WC33 BA RFEC SRFEC SRFEC2 V O2 A HE-001 I A O V N/A DIC FAX T T D/T D P NC M C TV I C P N M TV D F W CL D/T CR CAM INTC T-2 14 1SF 1BL 1-01A ± 0" 100.00 ±0" OFFICE 1-01 1 1 1 A3-1 0 A3-1 4 3 2 1 A5 MEDICAL AIR OXYGEN VACUUM AUTOMATIC DOOR PUSH PLATE MA TCH L I NE - S EE A1 -2 FLOOR LINE ELEVATION INDICATES WORK SIDE OR WORK TO BE REMOVED HIDDEN OR FUTURE WORK PROPERTY/REFERENCE LINE MATCH LINE SECTION LINE CENTER LINE CHANGE IN FLOOR OR CEILING ELEVATION (PLAN VIEW) BENCH MARK ELEVATION SPOT ELEVATION NEW WORK NEW SWING DOOR NEW SWING DOOR (90 Deg.) EXISTING DOOR TO REMAIN EXISTING DOOR TO BE REMOVED NEW PARTITION PARTITION TO BE DEMOLISHED EXISTING PARTITION w/ EMER. RELEASE HARDWARE NEW SWING DOOR (180 Deg.) WALL CLOCK TELEVISION OUTLET CODE BUTTON INTERCOM MONITOR OUTLET NURSE CALL PANIC BUTTON DATA OUTLET DATA/PHONE OUTLET WALL PHONE FAX OUTLET DICTAPHONE FLOOR RECESSED DATA/PHONE OUTLET TELEPHONE OUTLET HOSPITAL EQUIPMENT TAG (REF SPEC SECTION 11700) CHR-1 CHAIR RAIL CORNER GUARD FIRE EXTINGUISHERS TOILET ACCESSORIES TAG DEMOLITION NOTES (ON DEMOLITION PLANS) FURNITURE OR EQUIPMENT FURNISHED BY OWNER. GENERAL NOTES STOREFRONT TAG BORROWED LIGHT TAG DOOR NUMBER TAG ELEVATION TAG ON SECTION PARTITION TYPE TAG ELEVATION TAG PLAN OR ENLARGED DETAIL TAG BUILDING OR WALL SECTION TAG ROOM NAME & NUMBER TAG ROOM NAME & NUMBER TAG NEW COLUMN LINE REFERENCE EXISTING COLUMN LINE REFERENCE WALL MTD RECESSED CR-1 HR-1 RECESSED FIRE EXTINGUISHER CABINET SEMI-RECESSED FIRE EXTINGUISHER CABINET SEMI-RECESSED FIRE EXTINGUISHER CABINET (2 HOUR RATED) SEE X/AXX FOR DETAILS DOOR CARD READER DOOR CONTROL SECURITY CAMERA INTERCOM WITH CAMERA HANDRAIL CRASH RAIL PLUMBING RISER (SEE PLUMBING DWGS) PR-X" 96.5 BM A/C AB AC ACC ACT AD ADHES ADJ AFF AGGR AHU ALT ALUM ANOD ARCH ASB ASPH AUTO BD BITUM BLDG BLK BLKG BM BOT BR BRG BRK BRZ BSMT BTU BUR BV CAB CB CC CCT CCU CEM CFCI CFOI CG CHR CI CIR CJ C CLG CLKG CLO CLOS CLR CMU CO COL CONC CONF CONN CONT CONTR CORR CPT CR CS CSI CSMT CT CW D/A DBL DEG DEMO DEMOUNT DEP DET DF DH DIA DIAG DIM DIV DN DR DW DWG DWR E EA ED EF EIFS EJ EL ELEC ELEV EMERG ENCL EO EPS EXPS EQ EQUIP ETR EWC EXCAV EXH EXIST EXP EXT FA FAB FD FE FEC FF EL FHEC FHC FIN FLR FLUOR FM FOC FOF FOS FPRF FRPL FRT FT (') FTG FURN FURR FUT GA GALV GC GL GRD GYP GWB AIR CONDITIONING ANCHOR BOLT ACROVYN ACCESS ACOUSTICAL CEILING TILE AREA DRAIN ADHESIVE ADJUSTABLE ABOVE FINISHED FLOOR AGGREGATE AIR HANDLING UNIT ALTERNATE ALUMINUM ANODIZED ARCHITECTURAL ASBESTOS ASPHALT AUTOMATIC BOARD BITUMINOUS BUILDING BLOCK BLOCKING BENCH MARK BOTTOM BUMPER RAIL BEARING BRICK BRONZE BASEMENT BRITISH THERMAL UNIT BUILT-UP ROOFING BEVELED CABINET CATCH BASIN CUBICLE CURTAIN CUBICLE CURTAIN TRACK CORONARY CARE UNIT CEMENT CONTRATOR FURNISHED CONTRACTOR INSTALLED CONTRACTOR FURNISHED OWNER INSTALLED CORNER GUARD CHAIR RAIL CAST IRON CIRCLE CONSTRUCTION JOINT CENTER LINE CEILING CAULKING CLOSET CLOSURE CLEAR CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONFERENCE CONNECT (ION) CONTINUOUS CONTRACTOR CORRIDOR CARPET CRASH RAIL CENTRAL STERILE CONSTRUCTION SPECIFICATION INSTITUTE CASEMENT CERAMIC TILE COLD WATER DOUBLE ACTING DOUBLE DEGREE DEMOLITION DEMOUNTABLE DEPRESSED DETAIL DRINKING FOUNTAIN DOUBLE HUNG DIAMETER DIAGONAL DIMENSION DIVISION DOWN DOOR DISHWASHER DRAWING DRAWER EAST EACH EMERGENCY DEPARTMENT EXHAUST FAN EXTERIOR INSULATING FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRIC (AL) ELEVATOR EMERGENCY ENCLOSURE EMERGENCY ELECTRICAL OUTLET EPOXY PAINT SYSTEM EXTERIOR PAINT SYSTEM EQUAL EQUIPMENT EXISTING TO REMAIN ELECTRIC WATER COOLER EXCAVATE EXHAUST EXISTING EXPANSION EXTERIOR FIRE ALARM FABRICATED FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR ELEVATION FIRE HOSE & EXTINGUISHER CABINET FIRE HOSE CABINET FINISH (ED) FLOOR FLUORESCENT FACTORY MUTUAL FACE OF CONCRETE FACE OF FINISH FACE OF STUD FIREPROOF FIREPLACE FIRE RETARTANT TREATED FOOT / FEET FOOTING FURNISH, FURNITURE FURRED, FURRING FUTURE GAUGE GALVANIZED GENERAL CONTRACTOR GLASS, GLAZING GRADE GYPSUM BOARD, GYPSUM GYPSUM WALLBOARD HB H/C HCWD HD HDNR HDR HDWD HDWR HM HORIZ HP HR HT HTG HVAC HW ICU ID IN (") INCL INFO INSUL INT INV IPS IVT JAN JST JT KIT KO KPL KR L LAB LAM LAV LBL LF LH LHR LL LP MATL MAX MBR MECH MEMB MFR MH MIN MISC MO MOD MON MR MTD MTL MULL N N/A NIC NO, # NOM NRC NTS OA OBS OC OD OFCI OFF OFOI OH OPQ OPNG OPP PACU PAR PARTN PBD PC PERF PERIM P PLAM PLAS PLYWD PNL POLY PR PREFAB PRT PSF PSI PT PTSTA PVC PWC QT QTY R RA RAD RB RD REF REINF REQD RESIL REV RH RHR RM RO ROW RWC S SCHED SCWD SECT SEG SF SHR SHT SHTG SIM SJ SPEC SPKR SQ SS SSS SST STA STD STC STL STOR STRUCT SURG HOSE BIBB HANDICAPPED HOLLOW CORE WOOD HEAVY DUTY HARDENER HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HIGH POINT HAND RAIL HEIGHT HEATING HEATING, VENTILATING AND AIR CONDITIONING HOT WATER INTENSIVE CARE UNIT INSIDE DIAMETER INCHES INCLUDING INFORMATION INSULATE, INSULATION INTERIOR INVERT INTERIOR PAINT SYSTEM INTRAVENOUS (IV) TRACK JANITOR JOIST JOINT KITCHEN KNOCKOUT KICK PLATE KICK RAIL LENGTH LABORATORY LAMINATE (D) LAVATORY LABEL LINEAR FOOT (FEET) LEFT HAND LEFT HAND REVERSE LIVE LOAD LOW POINT MATERIAL MAXIMUM MEMBER MECHANICAL MEMBRANE MANUFACTURER MAN HOLE MINIMUM MISCELLANEOUS MASONRY OPENING MODULAR MONITOR MOISTURE RESISTANT MOUNTED METAL MULLION NORTH NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOISE REDUCTION COEFFICIENT NOT TO SCALE OVERALL OBSCURE ON CENTER OUTSIDE DIAMETER OWNER FURNISHED CONTRACTOR INSTALLED  Oÿ¨ðþÿ²÷ÿÿÿ‘ Öé™ FFICE OWNER FURNISHED OWNER INSTALLED OVERHEAD OPAQUE OPENING OPPOSITE POST ANESTHESIA CARE UNIT PARALLEL PARTITION PARTICLE BOARD PERSONAL COMPUTER PERFORATED PERIMETER PLATE PLASTIC LAMINATE PLASTER PLYWOOD PANEL POLYETHYLENE PAIR PREFABRICATED PRESSURE TREATED POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PAINT PNEUMATIC TUBE STATION POLYVINYL CHLORIDE PROTECTIVE WALL COVERING QUARRY TILE QUANTITY RISER RETURN AIR RADIUS RESILIENT BASE ROOF DRAIN REFRIGERATOR REINFORCED REQUIRED RUBBER REVISION RIGHT HAND RIGHT HAND REVERSE ROOM ROUGH OPENING RIGHT OF WAY RAINWATER CONDUCTOR SOUTH SCHEDULE SOLID CORE WOOD SECTION SEGMENT SQUARE FOOT SHOWER SHEET SHEATHING SIMILAR SEISMIC JOINT (EXTERIOR) SPECIFICATION SPEAKER SQUARE SOLID SURFACE SURGICAL SCRUB SINK STAINLESS STEEL STATION STANDARD SOUND TRANSMISSION CLASS STEEL STORAGE STRUCTURAL, STRUCTURE SURGERY TOPSOIL ROOF BALLAST CRUSHED GRAVEL CONCRETE CONCRETE BLOCK BRICK PLASTER, MORTAR, PRECAST CONC, CONC OR EIFS IN ELEV STUCCO/MORTAR STEEL ALUMINUM SHEET METAL (IN ELEVATION) MARBLE ACOUSTICAL CEILING TILE WOOD BLOCKING OR CONTINUOUS NAILER WOOD SHIM HARDWOOD TRIM PLYWOOD PLYWOOD BATT INSULATION RIGID INSULATION WATERPROOF MEMBRANE GLASS (LARGE SCALE) GYPSUM BOARD CERAMIC TILE CASEWORK TYPES SUSP SV SRV SYM T T&B T&G TEL TELEM TEMP TERR THK THRES TLT TOC TOF TOS TOW TRANSF TV TYP UL UNEXCAV UNFIN UON UR VAR VAT VB VCB VCT VERT VEST VIF VWC W W/ W/O WC WD WDW WF WI WT WWF WWM YD SUSPENDED SHEET VINYL SLIP RESISTANT VINYL SYMETRICAL TREAD (S) TOP AND BOTTOM TONGUE AND GROOVE TELEPHONE TELEMETRY TEMPORARY TERRAZZO THICK (NESS) THRESHOLD TOILET TOP OF CONCRETE TOP OF FOOTING TOP OF STEEL TOP OF WALL TRANSFORMER TELEVISION TYPICAL UDERWRITERS LABORATORY UNEXCAVATED UNFINISHED UNLESS OTHERWISE NOTED URINAL VARNISH VINYL ASBESTOS TILE VINYL BASE VINYL COVE BASE VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD VINYL WALL COVERING WEST WITH WITHOUT WATER CLOSET WOOD WINDOW WIDE FLANGE WROUGHT IRON WEIGHT WELDED WIRE FABRIC WELDED WIRE MESH YARD 1A WE 2 A8 WD 1 A8 7 A8 PREFIX PREFIX 8 A8 FCBD 6 A8 DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 1/8" = 1'-0" 4/14/2014 11:54:19 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh.rvt AG-1 201031 PHARMACY RENOVATION 4/11/14 ARCHITECTURAL STANDARD GRAPHICS ST. TECH. LOCK ELEV. CORR. STAIR EL. 227'-2" ELEV. ELEV. OR STORAGE MALE LOCKERS CORR. ELEV LOBBY FEMALE LOCKERS ON-CALL ED OFFICE ED OFFICE MEDICAL DIRECTOR ED MD LKRS ADMIN CONFERENCE ED OFFICE SPACE EMS ED OFFICE SPACE BREAK ROOM BREAK ROOM FEMALE LOCKERS TOIL/SH TOIL/SH MALE LOCKERS DN DN DN ISOL ROOM TOIL PHARMACY OFFICE WORK ROOM NURSE STA CORR PHYSICAL THERAPY STOR STORWORK ROOM CORR OFFICE EXAMOFFICE WK STA OFF ELEC VOLUNTEERS CHEMO PREP PASS I.V. PREP BREAKDOWN RECOVERYPHARM PICKING DISPENSING LOUNGE WK STA CLINICAL WORK STAIR CORR WAITING MECH CORR RAMP RAMP ELEV LOBBY MULTIPURPOSE LOCKERS TOIL EQP STOR ELEV ELEV ELEV SHAFT PHYSICAL THERAPY PHYSICAL THERAPY FREEZERS N1 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 N2 M1 M1 M1 M1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1 N1N1 N1 N1 N1 N1 N1 M1 N1 F1 C1 F1 C1F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 F1 C1 P1 P1 P1 N2 M1 N1 N1 M1 N1 M1 REMOVE EXIST EXTERIOR WINDOW REMOVE EXIST EXTERIOR WINDOW C2 C2 C2 CONSULT C2 CONSULT C2 C2 1. VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO DEMOLITION. NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. ALL ITEMS SHOWN DASHED TO BE REMOVED U.O.N. SEE DRAWINGS BY OTHERS FOR ADDITIONAL INFORMATION. 3. WHERE EXISTING CONSTRUCTION IS INDICATED TO BE REPLACED, THE INTENT IS TO REMOVE EXISTING IN ITS ENTIRETY AND REPLACE IT WITH NEW CONSTRUCTION AS INDICATED UNLESS OTHERWISE NOTED. 4. REMOVE CEILINGS IN AREAS WHERE NEW CEILINGS ARE INDICATED. REMOVE, RELOCATE AND REINSTALL EXISTING CEILING FIXTURES INDICATED TO REMAIN, TO MATCH NEW CEILING HEIGHTS. COORDINATE WITH ELECTRICAL, MECHANICAL AND PLUMBING DRAWINGS. 5. ALL PLUMBING, MECHANICAL AND ELECTRICAL WORK IN EXISTING PARTITIONS, EXTERIOR WALLS, FLOORS AND CEILINGS THAT INTERFERES WITH THE WORK SHALL BE RELOCATED, ADJUSTED, OR REPLACED TO SUIT THE NEW CONSTRUCTION. 6. ALL EXISTING EQUIPMENT, CASEWORK, MEP FIXTURES AND DEVICES, CEILING TILE, CURTAIN TRACKS, DOORS AND HARDWARE, ETC. INDICATED TO BE REMOVED SHALL BECOME THE PROPERTY OF THE OWNER. 7. MAINTAIN ANY EXISTING FIRE RATINGS WHERE EXISTING PENETRATING ITEMS ARE REMOVED OR ALTERED. F1 F - INTERIOR FLOOR: REMOVE EXISTING FLOORING AND BASE. REMOVE MASTIC DOWN TO A CLEAN EXISTING SUBSTRATE. PATCH AND LEVEL EXISTING SUBSTRATE AS REQUIRED AND PREP FOR NEW FINISHES. GENERAL NOTES FOR DEMOLITION: KEYED NOTES FOR DEMOLITION: C1 C - INTERIOR CEILING: REMOVE EXISTING CEILING TILE, GRID, AND SUSPENSION SYSTEM. SEE MEP DRAWINGS FOR RELATED DEMOLITION. USE CARE DURING REMOVAL AND CONSULT WITH OWNER FOR POTENTIAL SALVAGE/REUSE PRIOR TO DISPOSAL. REFER TO RCP FOR EXTENT OF NEW CEILING WORK CAREFULLY REMOVE PORTION OF EXIST FINISHED CEILING AS REQ'D, SAVE AND PROTECT DURING INSTALLATION OF NEW MEP WORK AND REINSTALL TO MATCH EXIST LAYOUT. PATCH AND MATCH (PM) ANY DAMAGED MATERIALS AS NECESSARY. REFER TO MEP DWGS FOR ADDITIONAL INFORMATION. C2 N1 N - INTERIOR WALL: REMOVE EXISTING INTERIOR PARTITION AND FRAMING REMOVE EXISTING INTERIOR DOOR, FRAME AND HARDWARE. CONSULT WITH OWNER FOR POTENTIAL SALVAGE/REUSE PRIOR TO DISPOSAL N2 M1 M - INTERIOR MILLWORK, CASEWORK AND FURNISHINGS: REMOVE EXISTING CASEWORK, COUNTER, SHELVING, AND ACCESSORIES, ETC. CONSULT WITH OWNER FOR POTENTIAL SALVAGE/REUSE PRIOR TO DISPOSAL. P1 P - MECH, ELEC AND PLBG: REMOVE EXISTING FIXTURE. SEE MEP DRAWINGS FOR SPECIFIC DEMOLITION REQUIREMENTS EXISTING CEILINGS ARE TO BE REMOVED AS REQUIRED, SAVED DURING INSTALLATION OF NEW MEP WORK AND REINSTALLED TO MATCH THE EXISTING LAYOUT. PATCH AND MATCH ANY DAMAGED MATERIAL. REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION ANY EXISTING CEILINGS ARE TO BE REMOVED AS REQUIRED, SAVED DURING INSTALLATION OF NEW MEP WORK AND REINSTALLED TO MATCH THE EXISTING LAYOUT. PATCH AND MATCH ANY DAMAGED MATERIAL. REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION EX MECH ROOM EX CORR EX GENERATOR ROOM EX CORR EX SOIL LINEN EX STORAGE ROOM EX STAIR EX SOIL LINEN EX TRANS VAULT EX CORR EX CORR EX AREAWAY DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 As indicated 4/14/2014 11:53:58 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh.rvt A1 201031 PHARMACY RENOVATION 4/11/14 FIRST FLOOR DEMOLITION PLAN AND PART PLANS SCALE: 1/8" = 1'-0"1 FIRST FLOOR DEMOLITION PLAN SCALE: 3/32" = 1'-0"3 EXISTING GROUND FLOOR PLAN SCALE: 3/32" = 1'-0"2 EXISTING BASEMENT FLOOR PLAN DN DN DN MECH 1-02 OFF 1-04 STERILE PREP 1-05 ANTE ROOM 1-06 PASS 1-01 CHEMO PREP 1-07 OFF 1-08 CORR 1-09 CORR 1-10 WK STA PHARM PICKING WK STA CLINICAL WORK BREAKOUT PASS DISPENING LOUNGE WORK ROOM 1-12 CORR STAIR ELEV LOBBY ELEV ELEVELEVEQP STOR MULTIPURPOSE STAFF LOCKERS STAFF TOIL MECH ELEC PHYSICAL THERAPY PHYSICAL THERAPY STOR OPEN TO CORR EX WORK ROOM 1-11 PHYSICAL THERAPY PHYSICAL THERAPY STOR OFF 1-03 OFF CORR CONSULT CONSULT STAIR STOR PASS PEDI TREATMENT PLAY STOR REF ER-2 TEMP LOCATION (OFI) FREEZER EF-1 (OFI) TEMP LOCATION SHLVG (OFI) SHLVG (OFI) A3 1 OFF 1-13 EX 2 HR FIRE/SMOKE BARRIER EX 2 HR FIRE/SMOKE BARRIER EX 2 HR FIRE/SMOKE BARRIER EX SMOKE BARRIER ER-1 REF REMAINS REF NR-1 (OFI) SHLVG (OFI) REF ER-2 (OFI) FREEZER ER-2 (OFI) SHLVG (OFI) REF (OFI) EXIT EXIT EX 2HR FIRE ENCLOSURE EX 2HR FIRE ENCLOSURE EXISTING SMOKE COMPARTMENT: 10, 200 SF 1 HOUR ENCLOSURE 1 HOUR ENCLOSURE EX HOUR ENCLOSURE NON-PHARMACY NON-PHARMACY P&M EX PART'NS AS REQ'D, MAINTAIN EX FIRE RATING SEE MEP DWGS FIRE RATING LEGEND RATED CONSTRUCTION IS INDICATED AS FOLLOWS: SMOKE PARTITION (NON-RATED) 1HR FIRE RATED BARRIER 2HR FIRE RATED BARRIER 1HR SMOKE BARRIER 2HR FIRE RATED/SMOKE BARRIER 1. MASSACHUSETTS STATE BUILDING CODE (780 CMR) 8TH EDITION - based on (2009) INTERNATIONAL BUILDING CODE with MASS AMENDMENTS 2000 NFPA 101 - LIFE SAFETY CODE MASSACHUSETTS STATE FUEL GAS AND PLUMBING CODE (248 CMR) MASSACHUSETTS STATE MECHANICAL CODE - based on 2009 IMC MASSACHUSETTS ELECTRICAL CODE (527 CMR 12) MASSACHUSETTS FIRE PREVENTION REGULATIONS (527 CMR) 2009 INTERNATIONAL FIRE CODE (IFC) 2009 INTERNATIONAL ENERGY CODE (IECC) - with MASSACHUSETTS AMENDMENTS - "STRETCH CODE" NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS NFPA 99 STANDARDS FOR HEALTH CARE FACILITIES 2010 GUIDELINES FOR DESIGN & CONSTRUCTION OF HOSPITAL & HEALTH CARE FACILITIES MASSACHUSETTS ARCHITECTURAL ACCESS BOARD (521 CMR) AMERICANS WITH DISABILITIES ACT ACCESSBILITY GUIDELINES (ADAAG 2010) APPLICABLE CODE AUTHORITIES FIRE RESISTANCE RATING SCHEDULE CONSTRUCTION CLASSIFICATION: NFPA 101: TYPE I (332) ELEMENTS PRIMARY FRAMING HOURLY RATING FIRE RESISTIVE DESIGN NO. RESTRAINED LOCATION/ REMARKS * NOTE: CORRIDOR PARTITIONS MUST RESIST THE PASSAGE OF SMOKE, EXCEPT AT HAZARDOUS AREAS WHERE PARTITIONS MUST BE 1 HOUR FIRE RATED IF GREATER THAN 100 SF IN AREA. OCCUPANCY CLASSIFICATION: I-2 HEALTHCARE IBC: TYPE 1A AUTOMATIC SPRINKLER PROTECTION: FULLY SPRINKLERED FACILITY HRS.3 N/A EXISTING CONCRETE FRAME FLOOR CONSTRUCTION HRS. 2 YES COMPOSITE CONC ON METAL DECKD902 ROOF CONSTRUCTION HRS. 1 1/2 N/A EXIST CORRIDORS * HRS. 0* N/A EXIT ENCLOSURES (STAIRS) HRS. 2 N/A SHAFT ENCLOSURES HRS. 2 N/A EXIST U415 SMOKE BARRIERS HRS. 1 N/A EXIST HAZARDOUS ROOMS HRS. 1 N/A U419 EXIST EX LINEN CHUTE SEALED UP PHARMACY LOCATE NEW FURRING (PAINTED) UP TIGHT AGAINST NEW PIPES SEE MEP DWGS FOR EXTENT OF WORK. P&M ADJACENT AREAS AS REQ'D SEAL ALL NEW FLOOR PENETRATIONS ABOVE AND BELOW W/ FIRE SAFING. MAINTAIN EXIST 2 HOUR FIRE RATING EX CONFERENCE ROOM EX STORAGE EX ADMIN EX ED OFFICE SPACE EX EMS EX OFFICE SPACE EX BREAK ROOM EX BREAK ROOM EX LOCKER ROOM EX CORR 3B EX AREAWAY SCALE: 1/8" = 1'-0"1 FIRST FLOOR REFERENCE PLAN DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 As indicated 4/14/2014 2:08:05 PM C:\Users\kmcintosh\Documents\C DH_201031_Pharmacy_kmcintosh.rvt A2 201031 PHARMACY RENOVATION 4/11/14 FIRST FLOOR REFERENCE PLAN AND PART GROUND FLOOR PLAN SCALE: 1/8" = 1'-0"2 PARTIAL GROUND FLOOR PLAN OFF 1-03 OFF 1-04 MECH 1-02 PASS 1-01 STERILE PREP 1-05 ANTE ROOM 1-06 CHEMO PREP 1-07 OFF 1-08 WK STA ELEC CORR 1-10 CORR 1-09 7'-10" ACT 7'-10" ACT 7'-10" ACT 7'-10" ACT 7'-10" ACT 7'-10" ACT OFF EX WORK ROOM 1-11 7'-8" ACT WORK ROOM 1-12 OFF 1-13 7'-10" ACT P & M EXIST CLG P & M EXIST CLG F.T. P & M EXIST CLG P & M EXIST CLG P & M EXIST CLG DN DN MECH 1-02 OFF 1-04 STERILE PREP 1-05 ANTE ROOM 1-06 PASS 1-01 CHEMO PREP 1-07 OFF 1-08 CORR 1-09 CORR 1-10 WK STA BREAKOUT ELEC OFF 1-03 FUME HOOD (EDGEGARD) (OFCI) FUME HOOD (EDGEGARD) (OFCI) CART (OFI) CART (OFI) CART (OFI) EXIST SHAFT EXIST CHUTE A5 24 1 3 A5 5 6 7 1-04 1-05 1-07 1-01 1-08 1-06 A5 9 8 10 1-02 CART (OFI) BIO SAFETY CABINET (STERILEGARD) (OFCI) EX WORK ROOM 1-11 1-13 OFF CLEAR MIN 5' - 0" V.I.F. 1' - 10" V.I.F. 1' - 8" NEW FLOOR SLAB INFILL 2 HR RATED CLEAR MIN 11' - 0" 2A 1A 3B 5A 1A 2A 2A 5A 5A5B 3A 5B 5B 1A 5B 5A 4A 5B 1A 2A 3B 5A A4 1 BIO SAFETY CABINET (STERILEGARD) (OFCI) V.I.F. 7' - 3"8' - 3 3/4" V.I.F. 1' - 1"8' - 10 3/4" V.I.F. 2' - 4" CLEAR 5' - 6"8' - 0 1/2"7' - 10" V.I.F. 10' - 0" 16x10 12x10 WORK ROOM 1-12 REF (OFI) NEW DRYWALL INFILL W/ IMPACT RESIST GWB ON CORR SIDE - ALIGN W/ EXIST BOTH SIDES V.I.F. 2' - 3" V.I.F. 1' - 4" ALIGN ALIGN 3B 3B 2' - 0" A5 13 OFF 1-13 1-03 3B 1A AUTO DOOR PP 12 11 A5 16 A5 14 15 17 MECH UNIT ON 4"H HSKPG PAD EXTEND 6" ALL SIDES OF UNIT SEE HVAC DWGS ALIGN W/ WIND JAMB P & M EXIST WALLS CG CG ST ST TABLE (OFI) ST ST TABLE (OFI) SHLVG (OFI) SHLVG (OFI) SHLVG (OFI) FREEZER EF-1 TEMP LOCATION (OFI) PP CR AUTO DOOR FACE OF EXIST 3B MIN 1' - 6" P & M EXIST WALLS REF (OFI) AUTO DOOR AUTO DOOR PP NEW DRYWALL INFILL W/ IMPACT RESIST GWB ON CORR SIDE NEW LOUVER SEE EXT ELEV NEW LOUVER CONSULT POS PRESSURE POS PRESSURE NEG PRESSURE PP PP PP PP 4" 4" CLEAR MIN 5' - 0" NON-PHARMACY PP SEAL ALL NEW FLOOR PENETRATIONS ABOVE AND BELOW W/ FIRE SAFING. MAINTAIN EXIST 2 HOUR FIRE RATING (TYP) 1. ALL CEILING HEIGHTS SHALL BE 7' - 10" AFF U.O.N. 2. ALL SOFFIT HEIGHTS SHALL BE 7' - 2" AFF U.O.N. 3. ALL CEILING GRIDS SHALL BE CENTERED IN THE ROOMS UNLESS OTHERWISE NOTED OR DEPICTED 4. DIMENSIONS LABELED "F.T." DEFINES THE USE OF A FULL TILE 5. LIGHTING AND FIRE ALARM DEVICES ARE SHOWN FOR LOCATION ONLY. REFER TO ELECTRICAL DRAWINGS, SCHEDULES, AND SPECS FOR QUANTITY AND TYPE. 6. EXIT SIGNAGE SHOWN FOR LOCATION ONLY. ADDITIONAL DEVICES MAY BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 7. REFER TO SPECIFICATIONS AND ROOM FINISH SCHEDULE FOR TYPICAL MATERIALS AND FINISHES. 8. SECURITY DEVICES SHOWN FOR LOCATION ONLY 9. ALL FIXTURES AND DEVICES TO BE CENTERED IN CEILING TILES TYPICAL, UNLESS OTHERWISE NOTED. RECESSED 2' X 4' FLUORESCENT LIGHT MECHANICAL SUPPLY DIFFUSER MECHANICAL RETURN REGISTER MECHANICAL EXHAUST SPEAKER NURSE CALL SMOKE DETECTOR SPRINKLER N S S EXISTING TO REMAIN CEILINGETR RECESSED 2' X 2' FLUORESCENT LIGHT DOWN LIGHT WALL SCONCE CEILING HEIGHT SYMBOL 2' X 2' ACOUSTIC TILE 2' X 4' ACOUSTIC TILE GYPSUM WALLBOARD CEILING OR SOFFIT EXIT SIGN REFLECTED CEILING NOTES AND LEGEND: X'-XX" MAT'L VACANCY SENSOR FIRE RATING LEGEND RATED CONSTRUCTION IS INDICATED AS FOLLOWS: SMOKE PARTITION (NON-RATED) 1HR FIRE RATED BARRIER 2HR FIRE RATED BARRIER 1HR SMOKE BARRIER 2HR FIRE RATED/SMOKE BARRIER 1. 1. ALL DIMENSIONS TO BE VERIFIED IN FIELD (V.I.F.) 2. ALL DIMENSIONS ARE TO FACE OF DRYWALL PARTITION AND FACE OF EXISTING UNLESS OTHERWISE NOTED OR DEPICTED. 3. PATCH EXIST WALLS AND FLOORS WHERE M.E.P. DEMOLITION WORK OCCURS. MATCH EXIST CONSTRUCTION AND MAINTAIN ALL EXISTING FIRE RATINGS. 4. CONTRACTOR TO VERIFY ALL EXIST PARTITIONS NOTED OR DEPICTED TO BE FIRE RATED. ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES. 5. ALL PARTITIONS SHALL BE TYPE 1A UNLESS OTHERWISE NOTED OR DEPICTED. SEE SHEET A5 FOR PARTITION TYPES. 6. ALL WHERE NEW AND EXIST PARTITIONS ARE USED TO SUPPORT WALL CABINETS, MONITORS, LIGHT FIXTURES, PLUMBING FIXTURES, OR ANY OTHER HUNG EQUIPMENT; REDUCE STUD SPACING TO 1'-0" O.C. AND PROVIDE SOLID WOOD BLOCKING SUPPORT. SEE BLKG DETAIL ON SHEET A5. 7. PATCH AND MATCH ALL EXIST PARTITIONS AFFECTED BY THE WORK AND PREP FOR NEW FINISHES. 8. ALL DOORS SHALL BE LOCATED 4" FROM ADJACENT PARTITION UNLESS OTHERWISE NOTED OR DEPICTED. GENERAL NOTES: DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 As indicated 4/14/2014 11:54:03 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh.rvt A3 201031 PHARMACY RENOVATION 4/11/14 ENLARGED FIRST FLOOR PLAN AND REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0"2 PARTIAL FIRST FLOOR REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0"1 PARTIAL FIRST FLOOR PLAN EX BASEMENT FLOOR EX GROUND FLOOR EX FIRST FLOOR EX SECOND FLOOR EX THIRD FLOOR 217'-11 1/2" 227'-11 1/2" 239'-5 1/2" 249'-6" 260'-6" EX FOURTH FLOOR 271'-6" EX FIFTH FLOOR 282'-6" T.O. EX PENTHOUSE FLR 293'-4 1/4" (V.I.F.) T.O.S. EX PENT ROOF 309'-4 1/4" (V.I.F.) EX GRADE EX AREAWAY NEW LOUVER IN EXIST OPNG NEW LOUVER IN EXIST OPNG 3 A4 2 A4 4 A4 4 A4 3 A4 2 A4 V.I.F. 4' - 4" V.I.F. 5' - 0" V.I.F. 4' - 4" V.I.F. 5' - 0" 4" STORM RESISTANT ALUM LOUVER ASSEMBLY INSULATED DUCT, SEE MECH DWGS 3" 4" TRANSITION AVB MEMBRANE FLASHING EXIST INTERIOR FINISH (VIF) SEALANT AND BACKER ROD EXIST BRICK WOOD BLOCKING SHIM AS REQ'D EXIST CONCRETE BEAM DEMO NOTES: REMOVE EX WINDOW AND INTERIOR FINISHES AS REQ'D FOR NEW LOUVER AND DUCT INSTALLATION. NEW 3 5/8" STEEL STUD FURRING WITH GWB (PATCH AND MATCH TO EXIST FINISHES BEYOND) 4" STORM RESISTANT ALUM LOUVER ASSEMBLY TRANSITION AVB FLASHING WITH TERMINATION BAR SILL PAN FLASHING INSULATED ALUM BLANK OFF PANELS INSULATED DUCT, SEE MECH DWGS 3" 4" EXIST LIMESTONE SILL EXIST INTERIOR FINISH +/- 1' - 0" EXIST MASONRY AND CMU BACK-UP WALL NEW GWB PARTITION ON 3 5/8" STEEL STUD FURRING AND 3" BATT INSULATION CONT WOOD BLOCKING CONTINUOUS SEALANTDEMO NOTES : REMOVE EX WINDOW AND INTERIOR FINISHES AS REQ'D FOR NEW LOUVER AND DUCT INSTALLATION. SEALANT AND BACKER ROD EXIST BRICK AND CMU BACK-UP WALL INSULATED DUCT, SEE MECH DWGS TRANSITION AVB MEMBRANE FLASHING 4" STORM RESISTANT LOUVER ASSEMBLY CONT WOOD BLOCKING EXTERIOR INTERIOR 3"4 " +/- 1' - 0" EXIST INTERIOR FURRED PARTITION (VIF) ST STL CLIP ANGLES AT 24" OC 2" INSUL ALUM BLANK-OFF PANEL NEW GWB PARTITION ON 3 5/8" STEEL STUD FURRING AND 3" BATT INSULATION DEMO NOTES: REMOVE EX WINDOW AND INTERIOR FINISHES AS REQ'D FOR NEW LOUVER AND DUCT INSTALLATION. DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 As indicated 4/14/2014 11:54:04 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh.rvt A4 201031 PHARMACY RENOVATION 4/11/14 EXTERIOR ELEVATIONS AND DETAILS SCALE: 1/8" = 1'-0"1 WEST ELEVATION SCALE: 1 1/2" = 1'-0"2 SECTION DETAIL AT LOUVER HEAD SCALE: 1 1/2" = 1'-0"3 SECTION DETAIL AT LOUVER SILL SCALE: 1 1/2" = 1'-0"4 JAMB DETAIL AT LOUVER BASE - SEE RFS (TYP) LOW WALL RETURN GRILLE SSM COUNTER, BACK AND SIDE SPLASHES PASS THRU CAB (OFCI) SEAL TIGHT 4' - 4" 2' - 1" 3' - 2" 2' - 6 1/2" FILE (OFI) REFER TO DOOR TYPES ON SHEET A7 TYPICAL DOOR OPERATOR 48" AFF MAX COORD FINAL LOCATION W/ OWNER F WC30 WC30 WC30 F SSM COUNTER, BACK AND SIDE SPLASH EASE CNTR EDGES PLAM WALL CAB W/ ADJ SHLVG METAL SUPPORTS AT 4'-0" OC MAX (TYP) BASE U/C LIGHT FIXT SEE ELEC DWGS 2' - 6 1/2"2' - 1 1/2"2' - 6" 7' - 2" 2' - 1" 2' - 1" SOFFIT 4 A8 OPEN SSM COUNTER AND BACK SPLASH - EASE EDGES TYPICAL PLAM WALL CAB W/ ADJ SHLVG WD30 FC30 F SSM COUNTER , BACK AND SIDE SPLASH EASE CNTR EDGES U/C LIGHT FIXT SEE ELEC DWGS 3' - 2" PEGBOARD METAL SUPPORTS AT 4'-0" OC MAX PTD TO MATCH WALL (TYP) PASS THRU CAB (OFCI) SEAL TIGHT P.LAM END PANEL SINK BASE - SEE RFS SOAP DISP (OFCI) MTD 42" MAX AFF TO OPERABLE PART P.T. DISP (OFCI) MTD TO SIDE OF CAB 42" MAX AFF FULL HT PLAM OPEN FACE CAB W/ ADJ SHLVG 2' - 10" 7' - 2" EYE WASH FILE (OFI) 2' - 6 1/2" DOOR OPERATOR 48" AFF MAX COORD FINAL LOCATION W/ OWNER BD30 FUME HOOD EDGEGARD (OFCI) FUME HOOD EDGEGARD (OFCI) LOW WALL RETURN GRILLE SEE HVAC DWGS ST ST TABLE (OCI) PASS THRU CABINET (OFCI) REF (OFI) DOOR OPERATOR 48" MAX AFF COORD FINAL LOCATION W/ OWNER PASS THRU CAB (OFCI) ST ST TABLE (OFCI) DOOR OPERATOR 48" MAX AFF COORD FINAL LOCATION W/ OWNER REF (OFI) BIOSAFETY CABINET STERILEGARD (OFCI) BIOSAFETY CABINET STERILEGARD (OFCI) P.LAM OPEN FACE WALL CABS U/C LIGHT FIXT SEE ELEC DWGS PLAM COUNTER W/ GROMMETS - PROVIDE 3mm PVC EDGE BANDING MTL BRACKET SUPPORTS 4'-0" OC MAX - PTD TO MATCH WALL BASE - SEE RFS TYP 2' - 6" 2' - 1 1/2" VERIFY 2' - 6 1/2" FILE (OFI) NOTE: COORD COUNTER HEIGHT W/ OWNER FURNISHED FILE CABS (TYP) WE36 WE36 F SOFFIT (TYP) 4 A8 FWE30WE30WE30WE30F 2' - 6 1/2"2' - 1 1/2"2' - 6" P.LAM OPEN FACE WALL CABS U/C LIGHT FIXT SEE ELEC DWGS COUNTER W/ GROMMETS - PROVIDE 3mm EDGE BANDING MTL BRACKET SUPPORTS 4'-0" OC MAX - PTD TO MATCH WALL BASE - SEE RFS TYP SOFFIT (TYP) NOTE: COORD COUNTER HEIGHT W/ OWNER FURNISHED FILE CABS (TYP) FILE (OFI) 4 A8 V.I.F. 2' - 6 1/2"2' - 1 1/2"2' - 6" F WE24 WE24 P.LAM OPEN FACE WALL CABS U/C LIGHT FIXT SEE ELEC DWGS PLAM COUNTER W/ GROMMETS - PROVIDE 3mm PVC EDGE BANDING MTL BRACKET SUPPORTS 4'-0" OC MAX - PTD TO MATCH WALL BASE - SEE RFS TYP 4 A8 P.LAM OPEN FACE WALL CABS U/C LIGHT FIXT SEE ELEC DWGS PLAM COUNTER W/ GROMMETS - PROVIDE 3mm PVC EDGE BANDING MTL BRACKET SUPPORTS 4'-0" OC MAX - PTD TO MATCH WALL BASE - SEE RFS TYP 2' - 6 1/2"2' - 1 1/2"2' - 6" FWE27WE30WE30WE27F SOFFIT (TYP) NOTE: COORD COUNTER HEIGHT W/ OWNER FURNISHED FILE CABS (TYP) 4 A8 2' - 6 1/2" PLAM COUNTER W/ GROMMETS - PROVIDE 3mm PVC EDGE BANDING MTL BRACKET SUPPORTS 4'-0" OC MAX - PTD TO MATCH WALL BASE - SEE RFS TYP 4 A8 P.LAM OPEN FACE WALL CABS U/C LIGHT FIXT SEE ELEC DWGS PLAM COUNTER W/ GROMMETS - PROVIDE 3mm PVC EDGE BANDING MTL BRACKET SUPPORTS 4'-0" OC MAX - PTD TO MATCH WALL BASE - SEE RFS TYP SOFFIT 2' - 6" 2' - 1 1/2" V.I.F. 2' - 6 1/2" FWE27WE30WE30WE27F FILE (OFI) NOTE: COORD COUNTER HEIGHT W/ OWNER FURNISHED FILE CABS (TYP) 4 A8 PLAM COUNTER W/ GROMMETS - PROVIDE 3mm PVC EDGE BANDING 2' - 6 1/2" 4 A8 1. PROVIDE 1 - 1/2" (MINIMUM) FILLER PIECE ON WALL AND BASE CABINETS AND 1 -1/2" (MINIMUM) EXTENSION TO COUNTER WHERE ENDS OF CASEWORK ABUT WALL. 2. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION. 3. PROVIDE SOLID WOOD BLOCKING IN PARTITIONS AT ALL LOCATIONS WHERE SUPPORT IS REQUIRED FOR CASEWORK AND HUNG FIXTURES AND EQUIPMENT. SEE DETAIL 2/A6. 4. WHERE VALANCES ARE PROVIDED, EXTEND SIDE PANELS OF WALL CABINET TO MATCH LIGHT VALANCE DIMENSION IF CABINET DOES NOT TERMINATE AT A WALL. 5. PROVIDE VALANCES AND BACKSPLASHES IN LONGEST POSSIBLE LENGTH OF MATERIAL TO MINIMIZE JOINTS. 6. FILLER PIECE SCRIBED TO SOFFIT AND WALL (TYPICAL). SEE DETAIL 5/A8. 7. PROVIDE 3mm PVC EDGE BANDING ON ALL PLAM COUNTER TOP EDGES, DRAWER AND DOOR FRONT EDGES, TYP. 8. ALL SSM COUNTERS TO HAVE EASED EDGES. 9. FURNITURE AND EQUIPMENT SHOWN FOR REFERENCE ONLY UNLESS OTHERWISE NOTED. 10. SEE SHEET AG-1 FOR STANDARD CASEWORK TYPES 11. REFER TO RCP FOR ALL CLG HEIGHTS 12. REFER TO SPECIFICATIONS AND ROOM FINISH SCHEDULE FOR MATERIALS AND FINISHES. INTERIOR ELEVATION NOTES: DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 As indicated 4/14/2014 11:54:07 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh.rvt A5 201031 PHARMACY RENOVATION 4/11/14 INTERIOR ELEVATIONS SCALE: 3/8" = 1'-0"1 ANTE ROOM - NORTH SCALE: 3/8" = 1'-0"2 ANTE ROOM - EAST SCALE: 3/8" = 1'-0"3 ANTE ROOM - SOUTH SCALE: 3/8" = 1'-0"4 ANTE ROOM - WEST SCALE: 3/8" = 1'-0"5 STERILE PREP - NORTH SCALE: 3/8" = 1'-0"6 STERILE PREP - EAST SCALE: 3/8" = 1'-0"7 STERILE PREP - SOUTH SCALE: 3/8" = 1'-0"8 CHEMO PREP - NORTH SCALE: 3/8" = 1'-0"9 CHEMO PREP - EAST SCALE: 3/8" = 1'-0"10 CHEMO PREP - WEST SCALE: 3/8" = 1'-0"11 OFF 1-08 - NORTH SCALE: 3/8" = 1'-0"13 OFF 1-08 - SOUTH SCALE: 3/8" = 1'-0"12 OFF 1-08 - EAST SCALE: 3/8" = 1'-0"14 OFF 1-03- SOUTH SCALE: 3/8" = 1'-0"15 OFF 1-03 - WEST SCALE: 3/8" = 1'-0"16 OFF 1-04 - NORTH SCALE: 3/8" = 1'-0"17 OFF 1-04 - EAST STRUCTURAL DECK STUD RUNNER ANCHORED TO STRUCTURAL DECK CEILING AS SCHEDULED 3 1/2" SOUND ATTENUATION GLASS FIBER BATTS @ TYPE, STC 49, BOTH SIDES 1 LAYER 5/8" GWB ON ROOM SIDE 3 5/8" METAL STUDS @ 16" O.C. TO UNDERSIDE OF STRUCTURAL DECK STUD RUNNER ANCHORED TO FLOOR SEALANT - BOTH SIDES CORRIDOR SIDE 1 LAYER 5/8" IMPACT RESIST GWB ON CORRIDOR SIDE SEALANT - BOTH SIDES 1 LAYER GWB EA SIDE IMPACT RESIST ON CORR SIDE ON 3 5/8" METAL STUDS - NON RATED STC 45 CORRIDOR PARTITION DETAIL 1 LAYER GWB EA SIDE IMPACT RESIST ON CORR SIDE ON 3 5/8" METAL STUDS - 1 HOUR RATED (UL NO U419) STC 45 5ATYPE 5BTYPE STRUCTURAL DECK STUD RUNNER ANCHORED TO STRUCTURAL DECK CEILING AS SCHEDULED 1 LAYER 5/8" GWB BOTH SIDES 3 1/2" SOUND ATTENUATION GLASS FIBER BATTS METAL STUDS @ 16" O.C. TO UNDERSIDE OF STRUCTURAL DECK STUD RUNNER ANCHORED TO FLOOR SEALANT BOTH SIDES 4 7/8" SEALANT BOTH SIDES 1ATYPE 1 LAYER GWB EA SIDE ON 3 5/8" METAL STUDS NON RATED, STC 45 DRYWALL PARTITION DETAIL A6 5 STRUCTURAL DECK STUD RUNNER ANCHORED TO STRUCTURAL DECK CEILING AS SCHEDULED 1 LAYER 5/8" GWB BOTH SIDES 3 1/2" SOUND ATTENUATION GLASS FIBER BATTS METAL STUDS @ 16" O.C. TO UNDERSIDE OF STRUCTURAL DECK STUD RUNNER ANCHORED TO FLOOR SEALANT BOTH SIDES 4 7/8" SEALANT BOTH SIDES 1 LAYER GWB EA SIDE ON 3 5/8" METAL STUDS 1 HOUR RATED (UL NO U419) STC 45 FIRE RATED DRYWALL PARTITION DETAIL 2ATYPE STUD RUNNER ANCHORED TO STRUCTURAL DECK SOUND ATTENUATION GLASS FIBER BATTS STUD RUNNERS ANCHORED TO FLOOR CEILING AS SCHEDULED SEALANT STRUCTURAL DECK FACE OF EXISTING WHERE OCCURS METAL STUDS @ 16" O.C. TO UNDERSIDE OF STRUCTURAL DECK VARIES 4" 5/8" GWB 1 LAYER GWB ONE SIDE ON 1 5/8" METAL STUDS NON RATED DRYWALL FURRING DETAIL 1 LAYER GWB ONE SIDE ON 2 1/2" METAL STUDS NON RATED 1 LAYER GWB ONE SIDE ON 3 5/8" METAL STUDS NON RATED 3ATYPE 3BTYPE 3CTYPE STRUCTURAL DECK 1" SOUND ATTENUATION GLASS FIBER BATTS SEALANT 2 LAYERS OF 1/2" FIRE RATED GWB VARIES CH-STUDS @ 24" O.C. METAL J-RUNNER ANCHORED TO FLOOR 1" SHAFT LINER METAL J-RUNNER ANCHORED TO STRUCTURE ABOVE SEALANT CAVITY SHAFT WALL WITH 4" C-H STUDS - 2 HOUR RATED (UL NO. U415) STC 45 SHAFT WALL PARTITION DETAIL 4ATYPE DOUBLE LAYER GWB AT CORRIDORS ONE LAYER GWB INSULATION SEALANT TYPICAL GWB CONTROL JOINT MAXIMUM SPACING 30'-0" NOTE: SEE FLOOR PLANS AND PARTITION DETAILS FOR ADDITIONAL INFORMATION 7/8" 7/8" METAL STUDS PROVIDE WOOD BLOCKING WHERE FASTENERS ARE LOCATED AT WALL MOUNTED ITEMS (TYPICAL). SECURE WOOD BLOCKING WITH 3 SCREWS PER STUD 2" x 6" (NOMINAL) MINIMUM CONT RUNNER GWB PARTITION SEE PLANS AND DETAILS FOR TYPES VARIES SEE DETAILS 3" HIGH IMPACT VINYL CORNER GUARD ANCHOR PER MANUFACTURER'S RECOMMENDATION CONTINUOUS ALUMINUM RETAINER PARTITION TYPE AS SCHEDULED 3" STRUCTURAL DECK FIRE STOPPING MATERIAL @ RATED WALLS AS SPECIFIED OVERSIZED OUTER TRACK - CONNECT TO DECK @ 12" O.C. MAX. EXTENDED LEG OF INNER TRACK DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 As indicated 4/14/2014 11:54:09 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh.rvt A6 201031 PHARMACY RENOVATION 4/11/14 PARTITION TYPES AND DETAILS SCALE: 1 1/2" = 1'-0"1 PARTITION TYPES SCALE: 3" = 1'-0"3 PLAN DETAIL AT GWB PARTITION CONTROL JOINT SCALE: 3/4" = 1'-0"2 BLOCKING ISOMETRIC FOR WALL MOUNTED ITEMS SCALE: 3" = 1'-0"4 CORNER GUARD DETAIL (90deg CORNER) SCALE: 3" = 1'-0"5 DOUBLE TRACK HEAD DEFLECTION DETAIL ARMOR PLATES 34" NOTE: MOUNT DOOR PROTECTION PLATES ON PUSH SIDE OF DOOR, EXCEPT WHERE INDICATED FOR BOTH SIDES OF DOORS GLAZING - COORDINATE VISION PANEL WITH HARDWARE SELECTION KICKPLATE (16" MAX AT ALL LABELED DOORS ONLY) FINISH FLOOR ALIGN BOTTOM OF PLATES WITH BOTTOM OF DOOR KICKPLATE AND/OR ARMOR PLATE EDGE OF PUSH PLATE TO ALIGN WITH EDGE OF RESCUE PRIVACY LOCK 36" TO CENTERLINE KNOBS/LEVERS 40 5/16" TO CENTERLINE HOSPITAL LATCH, BATHSET, LATCHSET, LOCKSET AND EXIT DEVICE AT MANUFACTURER'S STANDARD HEIGHT PUSH BAR/PULL SET 42" TO CENTERLINE OF PUSH BAR COMBINATION PUSH/PULL PANEL 42" TO CENTERLINE OF PUSH PLATE OR DEADLOCK CYLINDER DEAD BOLT THUMB TURN 48" TO CENTERLINE ROLLER LATCH STRIKE 48" TO CENTERLINE 1 2" VARIES 2" 2" VARIES 2" VARIES 2" 2" VARIES HOSPITAL STOPS SEE 5/A7 2 FRAME ANCHORS - MINIMUM 3 PER JAMB STEEL FRAME GWB PARTITION - SEE FLOOR PLANS FOR TYPES DEPTH FRAME 1/2" 1/2" DOOR - SEE SCHEDULE 2" 1/8" THICK CONT STL REINF CHANNEL WELDED TO FRAME HEAD AT OPENINGS LARGER THAN 4'-0" INSTALL CRIPPLE STUDS IN CENTER ABOVE DOOR OPENING AT 16" OC STUD RUNNER HEADER 22 GA MIN 1/2" 1/2" GWB PARTITION - SEE FLOOR PLANS FOR TYPES STEEL FRAME 2" NOTE: AT EACH END OF STUD HEADER PROVIDE CRIPPLE STUD ANCHORED TO JAMB STUDS DEPTH FRAME VARIES 4" 5/8" 2" 45.00° AXON SECTION F FLUSH NL NARROW VIEW LITE 8" 4" 3' - 7" 8" HG TOP HALF GLAZED 8" 3' - 7" 8" 8" DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 As indicated 4/14/2014 11:54:11 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh.rvt A7 201031 PHARMACY RENOVATION 4/11/14 DOOR SCHEDULE, ROOM FINISH SCHEDULE AND DETAILS DOOR & FRAME SCHEDULE DOOR # DOOR SIZE GLAZING TYPE FRAME HARDWARE FIRE RATING REMARKSTYPE MATERIAL WIDTH HEIGHT Frame Type FRAME MAT HEAD JAMB SILL 1-01 NL WD 3'-8" 7'-0" 1 HM 3/A7 4/A7 04 - AUTO OPERATOR, SWING CLEAR HINGES, CARD READER 1-02 F WD 4'-0" 7'-0" 1 HM 3/A7 4/A7 06 45 MIN 1-03 F WD 3'-0" 7'-0" 1 HM 3/A7 4/A7 05 1-04 F WD 3'-0" 7'-0" 1 HM 3/A7 4/A7 05 1-05 HG WD 3'-6" 7'-0" 2 HM 3/A7 5/A7 03 - AUTO OPERATOR, HOSPITAL STOP 1-06 HG WD 3'-6" 7'-0" 2 HM 3/A7 5/A7 01 45 MIN AUTO OPERATOR, HOSPITAL STOP, INTERLOCK 1-07 HG WD 3'-6" 7'-0" 2 HM 3/A7 5/A7 02 - AUTO OPERATOR, HOSPITAL STOP, INTERLOCK 1-08 F WD 3'-0" 7'-0" 1 HM 3/A7 4/A7 05 1-13 F WD 3'-0" 7'-0" 1 HM 3/A7 4/A7 05 ROOM FINISH SCHEDULE ROOM NO. ROOM NAME FLOOR BASE WALL FINISH CASEWORK CASEWORK CEILING CEILING REMARKSVERTICAL COUNTER TOP MATERIAL FINISH 1-01 PASS SHTV1 RB1 PT - - ACT 1-02 MECH CONC - PT - - 1-03 OFF SHTV1 RB1 PT PLAM PLAM ACT 1-04 OFF SHTV1 RB1 PT PLAM PLAM ACT 1-05 STERILE PREP SHTV2 INT EPOXY PT - - ACT 1-06 ANTE ROOM SHTV2 INT EPOXY PT PLAM SSM ACT 1-07 CHEMO PREP SHTV2 INT EPOXY PT - - ACT 1-08 OFF SHTV1 RB1 PT PLAM PLAM ACT 1-09 CORR PM PM PT - - PM 1-10 CORR PM RB1 PT - - PM 1-11 EX WORK ROOM PM RB1 PT - - PM 1-12 WORK ROOM SHTV1 RB1 PT - - PM 1-13 OFF SHTV1 RB1 PT - - ACT SCALE: 3/4" = 1'-0"8 TYPICAL HARDWARE MOUNTING HEIGHTS SCALE: 1/4" = 1'-0"2 FRAME TYPE ELEVATIONS SCALE: 3" = 1'-0"4 JAMB DETAIL AT HOLLOW METAL DOOR FRAME SCALE: 3" = 1'-0"3 HEAD DETAIL AT HOLLOW METAL DOOR FRAME SCALE: 3" = 1'-0"5 HOSPITAL STOP FRAME DETAIL SCALE: 1/4" = 1'-0"1 DOOR TYPE ELEVATIONS 1 1 2 1 BLOCKING - TYPICAL ADJUSTABLE SHELF WITH MULTIPLE HOLES EVERY 1" OC 2 1/2" VARIES - REFER TO ELEVATIONS 1/2" TO RCPS VARIES - REFER 6" MIN LIGHT VALANCE SCRIBE CABINET TO SOFFIT AND CAULK WITH SEALANT CONTINOUS BLOCKING 5/8" GWB SOFFIT ON METAL STUDS SCRIBE TO WALL AND CAULK WITH SEALANT UNDER CABINET LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS FINISHED CEILING - SEE RCPS HINGED DOOR WITH PULL 1' - 3 3/4" MAX 1/4" 1" 1' - 2 3/4" 1" NOTE: PROVIDE 3mm PVC EDGE BANDING ON ALL DOOR FRONT EDGES BLOCKING TYPICAL ADJUSTABLE SHELVING WITH MULTIPLE HOLES EVERY 1" OC 2 1/2" VARIES - REFER TO ELEVATIONS 1/2" TO RCPS VARIES - REFER 6" MIN MAX 1/4" LIGHT VALANCE SCRIBE CABINET TO SOFFIT AND CAULK WITH SEALANT CONTINOUS BLOCKING 5/8" GWB SOFFIT ON METAL STUDS SCRIBE TO WALL AND CAULK WITH SEALANT UNDER CABINET LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS FINISHED CEILING - SEE RCPS HINGED DOOR WITH PULL 1' - 3 3/4" 1" 1' - 2 3/4" 1" NOTE: PROVIDE 3mm PVC EDGE BANDING ON ALL DOOR FRONT EDGES MULTIPLE HOLES FOR ADJUSTABLE SHELVING ADJUSTABLE SHELVING SPACE FOR DRAWER SLIDES DRAWER FILLER - SCRIBE TO WALL AND CAULK WITH SEALANT DRAWER FRONT FACE OF WALL FACE OF WALL 3/8" 1 1/2" MIN SECTION1 SECTION2 ELEVATION 3 FILLER - SCRIBE TO WALL AND CAULK WITH SEALANT DRAWER FRONT FACE OF WALL FACE OF WALL 2 1 1 MIN 1 1/2" WOOD CLEAT AT WALL BEYOND WHERE REQUIRED REFER TO FLOOR PLANS FOR PARTITION TYPES METAL SUPPORTS AT 4'-0" OC MAX SUBSTRATE PAINTED TO MATCH APRON BASE SSM COUNTER TOP ON SUBSTATE EASE ALL EDGES BLOCKING - TYPICAL 4" HIGH SSM BACKSPLASH UNLESS OTHERWISE NOTED ON ELEVATIONS - SCRIBE TO WALL AND CAULK WITH CONTINUOUS SEALANT FINISH FLOOR VARIES - REFER TO ELEVATIONS 2' - 1" MAX 7" PLAM APRON WITH SPECIFIED SINK VERIFY CUT OUT 1 1/2" REFER TO FLOOR PLANS FOR PARTITION TYPES METAL SUPPORTS AT 4'-0" OC MAX GROMMET SUBSTRATE PAINTED TO MATCH COUNTER BASE COUNTER TOP BLOCKING - TYPICAL 4" HIGH BACKSPLASH ONLY WHERE SHOWN ON INTERIOR ELEVATIONS SCRIBE TO WALL AND CAULK WITH CONTINUOUS SEALANT FINISH FLOOR REFER TO ELEVATIONS UNLESS NOTED OTHERWISE 2' - 1" NOTES: 1. SEE INTERIOR ELEVS FOR COUNTER TOP MATERIAL 2. PROVIDE 3mm PVC EDGE BANDING ON ALL PLAM EDGES 3. FOR SSM COUNTER - EASE ALL EDGES ADJUSTABLE SHELVING WITH MULTIPLE HOLES EVERY 1" OC 2 1/2" VARIES - REFER TO ELEVATIONS 1" TO RCPS VARIES - REFER 6" MIN MAX 1/4" LIGHT VALANCE SCRIBE CABINET TO SOFFIT AND CAULK WITH SEALANT 5/8" GWB SOFFIT ON METAL STUDS 1' - 3" SCRIBE TO WALL AND CAULK WITH SEALANT UNDER CABINET LIGHT - REFER TO ELECTRICAL DRAWINGS CONTINOUS BLOCKING FINISHED CEILING - SEE RCPS BLOCKING - TYPICAL 1" 1' - 2" 1" NOTE: PROVIDE 3mm PVC EDGE BANDING ON ALL EDGES FINISH FLOOR BASE OVER PLYWOOD BLOCKING - TYPICAL ADJUSTABLE SHELVING WITH MULTIPLE HOLES EVERY 1" OC BLOCKING TYPICAL SCRIBE CABINET TO SOFFIT AND CAULK WITH SEALANT CONTINOUS BLOCKING 5/8" GWB SOFFIT ON METAL STUDS FINISHED CEILING SEE RCPS 1" 7' - 2" TO RCPS VARIES - REFER 6" MIN 7' - 2" ADJUSTABLE SHELVING WITH MULTIPLE HOLES EVERY 1" OC 2' - 1" 3" DD Approval Signature Date Project North MorrisSwitzer Project Number Sheet Title and Number Date Scale Revision Date No Consultant Seals COOLEY DICKINSON HOSPITAL NORTHAMPTON MASSACHUSETTS morris switzer e n v i r o n m e n t s f o r h e a l t h © 2014 MorrisSwitzer Williston, Vermont Boston, Massachusetts Portland, Maine t 617.772.0260 11 Drydock Avenue Suite 2060 f 617.772.0261 morrisswitzer.com Boston, MA 02210 1 1/2" = 1'-0" 4/14/2014 11:54:12 AM C:\Users\kmcintosh\Documents\CDH_201031_Pharmacy_kmcintosh. rvt A8 201031 PHARMACY RENOVATION 4/11/14 MILLWORK DETAILS SCALE: 1 1/2" = 1'-0"1 SECTION AT WALL CABINET SCALE: 1 1/2" = 1'-0"2 SECTION AT WALL CABINET W/ TWO ADJ SHELVES SCALE: 1 1/2" = 1'-0"5 CASEWORK SCRIBE DETAIL SCALE: 1 1/2" = 1'-0"6 SECTION AT COUNTER WITH SINK SCALE: 1 1/2" = 1'-0"4 SECTION AT COUNTER SCALE: 1 1/2" = 1'-0"7 SECTION AT OPEN WALL CABINET WITH 2 ADJUSTABLE SHELVES SCALE: 1 1/2" = 1'-0"8 SECTION AT FULL HEIGHT CABINET MEP2.1.pdf H2A.pdf MEP3.1.pdf MEP2.2.pdf P3.1.pdf HP2.pdf FP3.1.pdf ED1.pdf MEP3.2.pdf HP2A.pdf EPS2.pdf H2.pdf FP2.pdf HD1.pdf