20-006 (5) 508 SYLVESTER RD BP-2019-0308 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:20-006 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: woodstove BUILDING PERMIT Permit# BP-2019-0308 Project# JS-2019-000500 Est.Cost: $4600.00 Fee: $40.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: THE FIRE PLACE 99401 Lot Size(sic.ft.): Owner: SWANN ZACH Zoning: Applicant. THE FIRE PLACE AT. 508 SYLVESTER RD Applicant Address: Phone: Insurance: P O BOX 606 (413)397-3463 () WC WHATELYMA01093 ISSUED ON.9/18/2018 0:00:00 TO PERFORM THE FOLLOWING WORK:NAPOLEAN OAKDALE WOOD STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 9/18/2018 0:00:00 $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner w City of Northampton ffMassachusetts Lp,A DEPARTMENT OF BUILDING INSPECTIONS °. R ED 212 Maicn n Street • Micipal Buildings Northampton, MR 01060 ��I.. SEP 10 M8 ! 40 DEPT.OF r3un DING mSPFCTIO�FNGL OR TWO FAMILY SOLID FUEL.APPLIANCE PERMIT APPLICATION NORTHAMPTON.MA 01060 FOR WOOD,COAL,PELLET,CORN,STRAW OR SIMILAR STOVES,OR FIREPLACES Check# /I Please film in all appropriate//information / 1. Name of Applicant: O U cC Address:,/06 06 Telephone: —T- 2. Owner of Property: 5G,Jc✓ rl Address: 5-0r J—y1t1e.51<r \t/7D 0/'c/)cr—' Telephone: y� 335 -sem 3. Status of Applicant: _Owner Contractor 4. Type or Brand of Stove coil) CJS/C�Q!C 5. UL Listing: Vt a 6. Estimated Cost: 0"C• tr 7. Email: �oeq�C4' �� �� $ -an— -rstntcf-S Sy �y . Cpm If applicant is not the homeowner:: Contractor nameDJE_ /e �c Email: Construction Supervisor's License Number V-7(VI Expiration Date Home Improvement Contractor Registration Number / J'V V 77 Expiration Date All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit 8. Certification: I hearby certify that the information contained herein is true and accurate to the best of my knowledge. DATE: APPLICANT'S SIGNATURE DATE: ?-Y� IHOMEOWNER'S SIGNATURE APPROVED DATE: 9 6 BUILDING OFFICIAL Ci�L� ti t JVi:� 1 ! '. i , s �. a' _ -= The Co nnnonwealth of Massachusetts Depal•ttrzent ofl idustrzalAccidents _ I Congress Street,Suite 100 Boston,MIM 02114-2017 —_ www.nzass gov/dia Workers=Compensation insurance Affidavit:General Businesses. TO BE FILED WITH THE PERMITTING AUTHORITY- ?_0131icant information Please Print Le6ibly Business!Oraanization Name:THE FIRE PLACE _Acdress:l06 S 1 ATE RD- P_O_BOX 606 C:-.,.-- S1.T-;Zip:1AIHATELY, MA 01093 Phone#,+:413-397-3463 Are you an employer?Check the appropriate box: Business Type(required): 1,!✓i I a-a ernoloyer with 10 employees(full and/ 5- ®Retail or part-time).' 6. F1Restaurant/Bar/Eating Establishment _ _ I a:n a sole proprietor or partnerhip and have no 7- Office and/or Sales(incl.real estate,auto,etc.) empievees working for me in any capacity. -No v ort:ers- comp.insurance required] 9- ❑Non profit '• = t Vic are a corporation and its officers have exercised 9_ Q Entertainment their richt of exemption per c. 152,§1(4),and we have 10.0 Manufacturing no employees.[No workers'comp.insurance required)* 11_[]Health Care =.❑ vve are a non-profit organization,staffed by volunteers, with no employees.[No workers'comp.insurance req-1 i 12_M Other =Anv applicant that checks box 1.1 must also fill out the section below showing theirworkew compensation policy information. —If the co:-po ate officers have exempted themselves,but the corporation has other employees,a workers compensation policy is required and such an organization should check box N1. I am an employer that is providing workers'conipensadon insurance for my employees Below is the policy information. Insurance Company Name:MA RETAIL MERCHANTS WC GROUP INC Insurers address:P_0_BOX 8592.22-9222 Cin:!State/Zip: BRAINTREE MA 02185 Polic:t-or Self-ins.Lic.#0140050336011116 Expiration Date. 1-/—17 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). ailuro to secure coverage as required under Section 25A of MGL c_152 can lead to the imposition of criminal penalties of a Tine up COS 1.500.00 and/or one-year imprisonment:as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to 5250.40 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Tnvestigations of the DIA for insurance coverage verification. I do hereby cerci ,ander the pains andpogdfies of perjury that the information provided above is trite and correct. Si--nature: Datta: Phone#:413-397-3463 Ojjicial use only. Do not write in this area,to be completed by city or town official_ n City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Boart)5.Selectmen's Office 6.Other jContact Person: Phone#.- www mass.govidia i i 9 3.0 PRE-INSTALLATION PREPARATION Clean all ashes from the inside of the existing appliance opening. Ensure the chimney and appliance are free of cracks, loose mortar, creosote deposits, blockages, or other signs of deterioration. If necessary, have repair work done by a qualified professional before installing the appliance. Do NOT remove bricks or mortar from the appliance. In case of an outside air inlet or ash dump, fill with fiberglass insulation. Adhere to minimum clearances as illustrated. 3.1 MINIMUM CLEARANCE TO COMBUSTIBLES MINIMUM CLEARANCES A Sidewall 12" (30.5cm) � _ COMBUSTIBLE MANTEL B Mantel 16 (40.6cm) 12" (30.5cm) Projection ` C Top facing 16" (40.6cm) D Side facing 6" (152mm) Ac N}Tla,_E fB C TOP E Hearth (front) Canada 18" (45.7cm) ! suRFncE USA 16" (40.6cm) - F Hearth (side) 8" (203mm) _ Eront of 48" (121.9cm) ert MINIMUM APPLIANCE • ' IoE�P�� R H Width (rear) 23" (58.4cm) A F «• Width (front) 28" (71.1 cm) J Height(front) 22" (55.9cm) N E K Height(rear) 19" (48.3cm) cHF°N_COMB . ARTN USr L Depth 18" (45.7cm) FLOOR PROTECR R L M Hearth depth Canada 22" (55.8cm) USA 20" (50.8cm) N Hearth width 46" (1 16.8cm) COMBUSTIBLE MgNTEI O Facing width 54 1/2" (138.4cm) � � P Facing Contemporary 45 1/2" _------- � y height (115.5cm) N6N c Traditional 44 1/2" cTI$LE (113 cm) Q Q Mantel Contemporary 45 1/2" P (115.5cm) ___ Traditional 44 1/2" K (113cm) s e, H R Height of top Contemporary 29 1/2" surface (74.9cm) x Traditional 28 1/2" (72.3cm) T L , :. S Side facing 13 1/4" (33.6cm) T Hearth (side) 9" (22.8cm) r NONN M U Sidewall 13" (33cm) HFq OUj k1f3 R PROTECTOR L W415-1773/B/07.31.18 10 3.2 HEARTH EXTENSION/FLOOR PROTECTION Hearth extensions/floor protection must be made of non-combustible materials.They must meet the following specifications: • Minimum extension to the front of the insert: - Canada: 18" (45.7cm) - USA: 16" (40.6cm) • Minimum 8" (203mm) extension to the sides of the insert • Minimum 0.5" (13mm)thickness Minimum (K')0.84 thermal conductivity factor; and • Minimum (R') 0.59 resistance value See chart below for more information. CONVERTING MATERIAL SPECIFICATIONS TO R OR K VALUES R=Thickness/K-Value K=Thickness/R-Value COMMON MATERIAL K-VALUE R-VALUE Per inch Per inch Micore 300 0.43 2.33 Wonderboard (cement board) 1.92 0.52 Common Brick 5.00 0.20 Cement Mortar 5.00 0.20 Ceramic Tile 12.50 0.08 Marble 11.00 0.09 Air Space (ventilated) 0.70 1.43 Sand and Gravel 1.70 0.59 Drywall (gypsum) 1.00 1.00 Rockwool or Fiberglass Batts 0.30 3.33 With K values, the lower value is a better insulator. With R values, the higher number is better. K-Value Example: A wood stove may call for thermal protection which has a K factor of 1 or less.A product such as Micore 300 Board from USG has a K-Value of approximately .43 per inch. Therefore, a 1/2" (12.7mm)thickness of this board would have a K-Value of.86, which meets the requirement of our example stove. R-Value Example: This fireplace calls for thermal protection with an R-Value of 0.59.This same board above is rated as having an R-Value of 2.33 for a 1"(25.4mm)thickness. Therefore, 1/2" (12.7mm)of the Micore 300 Board would have a R-value of 1.165, which meets the specifications for this fireplace. W415-1773/B/07.31.18 i 5 2.1 DIMENSIONS (COMPLETE WITH CAST SURROUND) 0 6' SIB" I [152mm] [30mm] [51112' 191/l' [749mm] 115116" 18' [141 mm] [4S7mm] - O EP13C CONTEMPORARY MODEL 440mm 673m [440mm] [673mm] 41112' [1 06 [152mm] _ 5118' 11112- ® [130mm] [S46mm] 28112' ■ [724mm] 1 215116" 18' [541 mm] [457mm] ® o EP13T TRADITIONAL MODEL 440m [440mm] 2'1/2' _ [673mm] 42112' [1080rni 2.2 SPECIFICATIONS Specifications EPI3 CHAMBER (D.W.H) 13 3/4" x 20 7/8" x 11 1/2" (349.3mm)x(530.3mm) x (292.1 mm) CAPACITY 1.8 ft' (0.05 m3) APPROX. AREA HEATED** 1500 ft2(139.4 m2) MAXIMUM HEAT OUTPUT*** 55,000 BTU/Hr HEAT OUTPUT* 11,000 -28,000 BTU/Hr DURATION LOW FIRE** 8 Hours WEIGHT COMPLETE 400 lbs(181.4 kg) WEIGHT OF BRICKS 80 lbs(36.3 kg) WEIGHT WITHOUT CAST SURROUND(COMPLETE WITH 250 lbs DOOR)AND BRICKS (113.4 kg) *As tested using test method 28 ** Figures will vary considerably with individual conditions. ***Wolf Steel Ltd. estimated realistic BTU/hr with cordwood logs and regular refueling. W415-1773/B/07.31.18 r ,