41 Title 5 5-17-18 Commonwealth of Massachusetts
Title 5 Official Inspection Form
rSubsurface Sewage Disposal System Form -Not for Voluntary Assessments
"+ab,= 41 AUTUMN LANE
Property Address
LADOUCEUR
Owner Owners Name
requir e4fo is NORTHAMPTON MASS 01062 MAY 17, 2018
rage. for every —_ ---- -- — - _"—
page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E l always complete all of Section D
A) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
RECOMMEND PUMPING EVERY ONE TO TWO YEARS AND ADDING CCLS BACTERIA.
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass" section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no"or"not determined"(Y, N, ND) for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old` or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
tins Lac•,e..ens Tale 5°Weal Inspection Form Subsurface Sewage Disposal System.Page 2 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
(4 Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
e —
d 41 AUTUMN LANE
—_ _ _ _—
Property Address - - -- - -- -- —
LADOUCEUR
Owner -- _
ers Nameinformation is NORTHAMPTON
p
required for every - N _. MASS 01062 MAY 17. 2018_
page. City/Town State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:When A. General Information
filling out forms
on the computer,
use only the tab 1. Inspector:
key to move your
cursor-do not NICK TORRETTI
use the return -- -- _
key. Name of Inspector
-- -- -- '"
CLEAN SEPTICS INC
a Company Name
eisrl
X P O BOX 39.4 252 WEST ST
DSI - 9 Company Address
LUDLOW MASS 01056
City/Town State Zip Code
413 583 2138 S 14496
Telephone Number
License Number —
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5(310 CMR 15.000). The system:
Passes ❑ Conditionally Passes ❑ Fails
❑ Needs Further Evaluation by the Local Approving Authority
,.L elreur
MAY 17 , 2018
Inspector's Signature -- -"-- ' '- "- -------
e
The system inspector shall submit a copy of this inspection report to the Approving Authority(Board
of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of
10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate
regional office of the DEP. The original should be sent to the system owner and copies sent to the
buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
thins drc..rev.6/16
Tine 5 Official L em:lion Form Subsurface sewage l ispusal System•Page 1 of 17
Commonwealth of Massachusetts
kte.±.. , Title 5 Official Inspection Form
;, Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
.
41 AUTUMN LANE _.___.__
Property Address
LADOUCEUR
Owner Owners Name
intonation for every
quireNORTHAMPTON MASS 01062 MAY 17, 2018
page.
e-
required - -- -- - - — --"- sp
pCity/Town State Zip Cade Date of Inspadion
B. Certification (cont.)
2. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system(SAS)and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the MS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well'•.
Method used to determine distance:
'e This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
3. Other:
D) System Failure Criteria Applicable to All Systems:
You must indicate"Yes"or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ __ Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ __ Liquid depth in cesspool is less than 6" below invert or available volume is less
than %a day flow
t5ina.da'rer.6116 Title 5 Official Inspedlon Form:Subsurface Sewage Disposal System•Page 4 of 7
Commonwealth of Massachusetts
- Title 5 Official Inspection Form
- ■ Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
8' 41 AUTUMN LANE
Property Address
LADOUCEUR
Owner's
Owner -'s --- --.-
Owner shame — —
information is NORTHAMPTON
page.
required for every _ _____ _.. ___. MASS 01062 MAY 17, 2018
page. Cityaown Stale Zip Code Date of Inspection
B. Certification (cont.)
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
B) System Conditionally Passes (cant):
El Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced ❑ V ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ V ❑ N ❑ ND (Explain below):
❑ distribution box is leveled or replaced ❑ V ❑ N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ V ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
C) Further Evaluation Is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
Sins da•re. St16
Title s Official Inspection Form SabudaW Sewage Disposal System•Page 3 W 17
,., Commonwealth of Massachusetts
I a Title 5 Official Inspection Form
r Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
tts
_ 41 AUTUMN LANE -
Property Address
LADOUCEUR
Owner Owner's Name
information is
required for every NORTHAMPTON MASS 01062 MAY 17, 2018
page City/Town State Zip Code Date of Inspection
C. Checklist
Check if the following have been done. You must indicate"yes" or"no' as to each of the following:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
O 0 Has the system received normal flows in the previous two week period?
Have large volumes of water been introduced to the system recently or as part of
❑ ® this inspection?
® ❑ Were as built plans of the system obtained and examined?(If they were not
available note as N/A)
O 0 Was the facility or dwelling inspected for signs of sewage back up?
O 0 Was the site inspected for signs of break out?
® 0 Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
® ❑ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS) on the site has
been determined based on:
® 0 Existing information. For example, a plan at the Board of Health.
® ❑ Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable)1310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
3
Number of bedrooms(design): 3 - Number of bedrooms (actual):
495 GPD
DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms): per plans
thins be•rev.6116 TPoe 50Rioal Inspedion Fon.SUSVMem Sewage Disposal System•Page 60117
Commonwealth of Massachusetts
=t'tE,EQ, Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
41 AUTUMN LANE
Prop—Address
Property Atltlreu
LADOUCEUR
Owner
OwneYs Name
requiratifo is
required for every
NORTHAMPTON _ _ _. MASS 01062 MAY 17, 2018
page. City/Town State Zip Code Date of Inspection
B. Certification (cont.)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ 0 Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered. A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area–IWPA) or a mapped Zone II of a public water supply well
If you have answered"yes" to any question in Section E the system is considered a significant threat,
or answered "yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
t5ins doe•rev 6/16
Tithe 5ORclol Inspection Form Subsurface Sewage Disposal System•Page 5 of 17
Commonwealth of Massachusetts
lTitle 5 Official Inspection Form
■I Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
ef >
,•
41 AUTUMN LANE _ ___. —_.__..
Property Address
LADOUCEUR
Owner Owner's Name
information is NORTHAMPTON MASS 01062 MAY 17, 2018 _.
required for every - -- --- -- -- _ - - - -
page Cny/lown State Zip Code Date of Inspection
D. System Information (cont.)
Last date of occupancy/use: Date
Other(describe below):
General Information
Pumping Records:
PUMPED 2016 PER OWNER
Source of information: -Was system pumped as part of the inspection? ❑ Yes ® No
If yes, volume pumped: —. - - - - " --
gallons
MEASURED
How was quantity pumped determined? - --- -- - ---- — _-- -
MAINTENANCE /PREP FOR INSPECTION
Reason for pumping:
— - "- " - -- _
Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology. Attach a copy of the current operation and
maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
•
t5ins doc•rer 6116 Tale 5 Official Inspection Form'.Subsurface SewNe Disposal System•Page 6 of 17
Commonwealth of Massachusetts
I ` Title 5 Official Inspection Form
t - �fl Subsurface Sewage Disposal System Form- Not for Voluntary Assessments
rim
N 41AUTUMNLANE
Property Address
LADOUCEUR
Owner Owners Name
information is NORTHAMPTON
required for every _._ __. MASS 01062 MAY 17, 2018
page. City?own —'""
Slats Zip Code Date of Inspection
D. System Information
Description:
Number of current residents: 2
Does residence have a garbage grinder? ❑ Yes ® No
Is laundry on a separate sewage system? (Include laundry system inspection
information in this report.) ❑ Yes ® No
Laundry system inspected? ❑ Yes ® No
Seasonal use?
❑ Yes ® No
Water meter readings, if available (last 2 years usage(gpd)): CITY/TOWN
WATER
Detail: - - --
Sump pump? ® Yes ❑ No
Last date of occupancy: PRESENT
Date
Commercial/Industrial Flow Conditions:
Type of Establishment.
Design flow(based on 310 CMR 15.203):
Gallons per day(gpd)
Basis of design flow(seats/persons/sq.k., etc.): ---- ----_
Grease trap present? ❑ Yes ❑ No
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available:
Esme doe•rev.6/16
Title s Official hix
pxtion Rion Subsurface Sewage Disposal System•Page r a 17
Commonwealth of Massachusetts
Irt alkis
. Title 5 Official Inspection Form
i— a Subsurface Sewage Disposal System Form Not for Voluntary Assessments
d" 41 AUTUMN LANE __. -
Property Address
LADOUCEUR
Owner Owners Name
inform
required
is NORTHAMPTON ._. MASS 01062 MAY 17, 2018
page, kfo r every - --- - —'
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Septic Tank(cont.)
Distance from top of sludge to bottom of outlet tee or baffle --- -- _ --— - -
3"
Scum thickness -- _
Distance from top of scum to top of outlet tee or baffle 7
Distance from bottom of scum to bottom of outlet tee or baffle 17
How were dimensions determined? MEASURED
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
RECOMMEND PUMPING THE SEPTIC TANK EVERY ONE-TWO YEARS, INLET AND OUTLET
BAFFLES APPEAR OK, SEPTIC TANK IS STRUCTURALLY SOUND, LIQUID LEVELS ARE AT
THE INVERT, NO LEAKAGE.
Grease Trap(locate on site plan):
Depth below grade: feet
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle -� —- - -— _ -
Distance from bottom of scum to bottom of outlet tee or baffle ----_ --- ——- _ —
Date of last pumping: Date --
Wins doe•ret.6n6 Tulle S Official Inspection Form Subsurface Sewage Dnpcsal System•Page 10 oil?
Z..\ Commonwealth of Massachusetts
J Title 5 Official Inspection Form
a Subsurface Sewage Disposal System Form- Not for Voluntary Assessments
t YYY
"It:,. 41 AUTUMN LANE
Properly Address
LADOUCEUR
Owner Owner
Page- City/Town Name
information is NORTHAMPTON
required for artery ____ MASS 01062 MAY 17, 2018
'wn state Zip Code Date of Inspection
D. System Information (cont.)
Approximate age of all components, date installed (if known)and source of information:
APPROXIMATELY NOVEMEBR 1 , 1994 PLANS ON FILE WITH THE BOARD OF HEALTH
Were sewage odors detected when arriving at the site? ❑ Yes ® No
Building Sewer(locate on site plan):
Depth below grade: 1' 8"
feet
Material of construction:
Z cast iron ®40 PVC ❑other(explain):
Distance from private water supply well or suction line: --- --- -_-- _.__.
feet
Comments(on condition of joints, venting, evidence of leakage, etc.):
JOINTS AND VENTING APPEAR OK, NO LEAKAGE
Septic Tank(locate on site plan):
Depth below grade: 12"
feet
Material of construction: -
® concrete ❑ metal ❑ fiberglass ❑ polyethylene
❑ other(explain)
CLEAN SEPTICS RECOMMENDS PUMPING THE SEPTIC TANK. THE SEPTIC TANK IS
STRUCTURALLY SOUND
If tank is metal, list age:
years
Is age confirmed by a Certificate of Compliance?(attach a copy of certificate) ❑ Yes ® No
Dimensions: 1500 GALLON SEPTIC TANK
Sludge depth: 10"
Sins doe•rev.Nth Title 501noe!Inspection Form:Subsurface Sewage Disposal System•Page 0 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
-FE0
41 AUTUMN LANE
Property Address
LADOUCEUR
Owner Owner's Name
information is NORTHAMPTONMASS 01062 MAY 17. 2018
required for even/
ry
City/Town
page. CState Zip Code Date of Inspection
D. System Information (cont.)
Distribution Box(if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert IT D-BOX IS APPROXIMATELY 1' 4" DEEP
Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
D-BOX IS EQUAL AND LEVEL, NO LEAKS, NO CARRY OVER
Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No*
Alarms in working order: ❑ Yes ❑ No`
Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.):
*If pumps or alarms are not in working order, system is a conditional pass.
Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why.
thins t c•re,.6116 Title 50111as Inspection Form:Subsurface Sewage Disposal Syslam-Page 12 M 17
• •\ Commonwealth of Massachusetts
LA gin Title 5 Official Inspection Form
rr `-
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
.-`-.," 41 AUTUMN LANE
Property Address -- -
LADOUCEUR_
Owner
Owners Name -"— '-- ----
information is
required far every NORTHAMPTON.
MASS 01062 MAY 17, 2018
pageCIty/Town State Zip Code
Dale of Inspection
D. System Information (cont.)
Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑concrete ❑ metal ❑fiberglass ❑ polyethylene
ID other(explain):
Dimensions:
Capacity:
gallons - —Design Flow:
gallons per day
Alarm present: ❑ Yes ❑ No
Alarm level: -- --- -- Alarm in working order: ❑ Yes ❑ No
Date of last pumping:
Date
Comments(condition of alarm and float switches, etc.):
`Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
thins clot•rev,8/16
Title S Official Inspection Form Subsurface Sewage Disposal System•Page 11 of IT
Commonwealth of Massachusetts
ITitle 5 Official Inspection Form
iil Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Ii,
d 41 AUTUMN LANE
Property Address
LADOUCEUR -- ----
Owner Owner's Name
information is NORTHAMPTON MASS 01062 MAY 17, 2018
required for every --- -- --- - - -- -- - - _ -- - -
page Crty/rowo State Zip Code Date of Inspection
D. System Information (cont.)
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
Privy (locate on site plan):
Materials of construction'. — - - --- - - _--- __-"- _--
Dimensions - —"" - --- -
Depth of solids
Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
ISMS doe rev.6M 6 Tine 5 offaeunspealm Form Subsurface Sewage Dispose]System•Page 14 of 17
Commonwealth of Massachusetts
ketF Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
41 AUTUMN LANE
Property Address - --'-- -'—-- -
LADOUCEUR
Owner
Owner's Name -- --'——-'- —
requiretifore NORTHAMPTON
required for every _ _ MASS 01062 _ MAY 17, 2018.
page. City/Town State Zip Code Date of In
spegion
D. System Information (cont.)
Type:
❑ leaching pits number: - -
❑ leaching chambers number: -- --- -.—
❑ leaching galleries number: - - -- -..—.
❑ leaching trenches number, length: 6 TRENCHES
OUTOF D-BOX
® leaching fields number, dimensions: Col 35' LENGTHS
by 30'WIDE
❑ overflow cesspool number: - --- ----
❑ innovative/alternative system
Type/name of technology: - ---------- _
Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
SOIL AND VEGETATION ARE OK, NO SIGNS OF HYDRAULIC FAILURE
Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration
Depth-top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow ❑ Yes ❑ No
bine Eec.re..Nts
Title 6 Oafa Inspecban Form Subsurface Sewage Dlspeal System•Page 13 Of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Era.- i Subsurface Sewage Disposal System Form -Not for Vol
-�;. yptary Assessments
n%:ff—. 41 AUTUMN LANE
Property Address
Owner LADOUCEUR —___ —
Owners Name
information is
required for every NORTHAMPTON MASS 01062
dryrtown
— —'—
State ZMAY 17 2018_
ip
page .Code Date of Inspection — —--_-
D. System Information (COPT)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system. including ties to
at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate
where public water supply enters the building. Check one of the boxes below:
0 hand-sketch in the area below
® drawing attached separately
o
. P . # 1 t9 (
IN/
-AREA' • iP
•
•l - ExlsriNp
I't a emnoaM fwSE
.es) ii • 0
• •. -
1 /00.00
`d. - "It!''' tqr 111o
�r—oI� I DISTRIBurIctN Inx
i
Ste ;/'
LINE ii
o.sr is
""N‘`� 1 ± luo. oo
'�1e LUES (see N I
11\\
notes)
PROPOSED 4m PVC PIPE (solid) ,
4" PVC PIPE (perf) S=.005
True s oma.Inspection Form.Subsurface Sewage ospo,d system.Sage IS m 17
I 1-Af'..1I All) OCn . rnr a . " . 4,,.. 2 .
..-\ Commonwealth of Massachusetts
LW
Title 5 Official Inspection Form
t. s Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
' 41 AUTUMN LANE _ _..— _. __---- –
Property Address
LADOUCEUROwner Owner's Name
information is NORTHAMPTON _MASS 01062 MAY 17, 2018requ
. City/Townown
tl for every
page - —"' ——- State Zip Code Date of Inspection
page
E. Report Completeness Checklist
E Inspection Summary:A, B, C, D, or E checked
E Inspection Summary D (System Failure Criteria Applicable to All Systems)completed
E System Information–Estimated depth to high groundwater
E Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file
tentacle rev.ens Title 5 Official Inspection Dorm Subsurface Sewage Disposal System.Page 17 at IT
�\ Commonwealth of Massachusetts
• w Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
41 AUTUMN LANE
Property Address
LADOUCEUR
Owner Owner's Name — --
information is _
requires for every
NORTHAMPTON _ _ _ MASS 01062 MAY 17, 2018
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Site Exam:
® Check Slope
❑ Surface water
® Check cellar
❑ Shallow wells
Estimated depth to high ground water NONE AT 8'
rest
Please indicate all methods used to determine the high ground water elevation:
® Obtained from system design plans on record
If checked, date of design plan reviewed: OCTOBER 24,1994
PLANS ON FILE AT THE B 0 H
® Observed site(abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health -.explain:
❑ Checked with local excavators, installers-(attach documentation)
❑ Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
CHECKED CELLAR AND SLOPE IN YARD PLANS BY TIM MAGINNIS
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
thins We•rev 6/16
Tee 6 Official inspection Form-Subsurface Sewage Disposal System•Page 16 oft]