25C-125 (7) 14 ELIZABETH ST BP-2019-0202
GIs a: COMMONWEALTH OF MASSACHUSETTS
Map:Block:25C- 125 CITY OF NORTHAMPTON
Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category:woodstove BUILDING PERMIT
Pertnit# BP-2019-0202
Project# JS-2019-000333
Est.Cost: $4700.00
Fee:$40.00 PERMISSIONIS HEREBY GRANTED TO:
const.Class: Contractor: License:
Use Grnnn: THE FIRE PLACE 99401
Lot Siae(sa.ft.): 3354.12 Owner. JONES ROBERT
zoning:URB(101)/ Applicant: THE FIRE PLACE
AT. 14 ELIZABETH ST
ApplicantAddress: Phone: Insurance:
P O BOX 606 (413) 397-3463 O WC
WHATELYMA01093 ISSUED ON.811712018 0:00:00
TO PERFORM THE FOLLOWING WORK.VT CASTINGS MONTPELIER WOOD INSERT
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House# Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy signature:
FeeType: Date Paid: Amount:
Building 8/17/2018 0:00:00 $40.00
212 Main Street,Phone(413)587-1240, Fax:(413)587-1272
Louis Hasbrouck—Building Commissioner
City of Northampton
rA. Massachusetts
DEPARTMENT OF BUILDING INSPECTIONS
li 312 Main Street & Municipal Building
Northamp[On, MA 01060
D
AUG 16 2018 gP ( 9' � 07 SC
NGL OR TWO FAMILY SOLID FUEL APPLIANCE PERMIT APPLICATION
nEPT Or aWI.DING INSPECTIONS
reoamnm,�TON.yea a�os D,COAL. PELLET,CORN,STRAW OR SIMILAR STOVES, OR.FIREPJ,ACES
Check# // &/0
Please fill in all appropriate Information
1. Name of Applicant '. ___ fJ009�tSAbbrr ' %hc ,�/cam/a<c
Address /11-C I J// !! 4IC'(,r mAO/093 Telephone. '//.3 397 3$yL .�
2. Owner of Property : _ _ /qpOqe(.{ Jd nr 7
Address. __p'1 Z5z1-p'1c`iV Telephone'. ro/T 79T-� 12L
3. Status of Applicant Owner X Contractor
4. Type cr Brand of Slove Y-/ e J-11 S '
5. UL Listing : (/L/yea
8. Estimated Cost y70o. d
7 Email
If applicant is not the homeowner:: I p/�
Contractor name�v,�/n_s Z -96� Email : C/�6 �� 6rrrl0rd --kn Armor3s.1V(y .rOM
Construction Supervisors License Number. 995/0/ Expiration Date /-( '
Home Improvement Contractor Registration Number / ;-o1/77 Expiration Date
All Applicants must complete a Workers Compensation Insurance Affidavit before we can issue a permit
8. Certification I hearby certify that the information contained herein is true and accurate to the best of my
knowledge,
DATE ,�'/ /�- APPLICANT'S SIGNATURE _
DATE.. _/p_/�'/� HOMEOWNER'S SIGNATURE
APPROVED
DATE _ ! (�_ BUILDING OFFICI
=c The Conunonivealth of Massachusetts
DepatT7nentoflndustrialAccidents
. '
1 Congress Street,Suite 100
--=„ Boston,MA 02114-2017
www niass.gov/dia
Workers'Compensation Insurance Affidavit.General Busfuessa.
TO BE FILED WITH THE PERMITTING AUTHORITY.
Applicant Information Please Print Leyjbly
Business/Organization Narne:THE FIRE PLACE
Address 106 STATE RD-P.O.BOX 606
Cn;State/zip:WHATELY, MA01093 Phone#:413-397-3463
Are you an employer?Check the appropriate box: Business Type(required):
j 1.❑✓ 1 am a employer with t0 employees(full and/ 5. ❑Retatl
or parr-time).' 6. ❑Restaurant/Bar/Eating Establishment
2.❑ i
all,a sole proprietor or partnership and have no 7, Q Office and/or Sala(incl.real estate,auto,etc.)
employees working for me in any capacity.
lNo workers'comp.insurance required] 8. Q Non-profit
3.❑ Nc arc a corporation and its officers,have exercised 9. ❑Entertainment
their riehtofexemption pert 152,§1(4),and we have 10.[]Manufacturing
no employees.[No workers'comp.insurance required]' I1 ❑Health Care
4.❑ we are a non-profit organization,staffed by volunteers,
with no employees.[No workers comp.insurance req.] 12.0 Other
'Any appliwni that checks bos al must alsofill wt Wesecdon Wow showing theirworkers cooryuaadon policy iafemwbon.
"frthe coeporanorieers haveuempad Ihenaelves,but We cowondan hes oWeremployees,a rvorkers'compemalion polity m required and suchen
mganf dan should check box 91.
last an employer(baths providing workers'compensation insurance for my emplayeas. Below is tke policy information.
insurance Company Name:MA RETAIL MERCHANTS WC GROUP INC
Insurer's Address:P.O.BOX 859222-9222
Cirvistate/Zip: BRAINTREE MA 02185
Policy k or Self-ins.Lia#0140050336011116 Expiration Date.
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to S 1,500.00 andlor one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine
crop to 5250.00 a day against the violator. Be advised that a copy ofthis statement may be forwarded to the Office of
Investigations ofthe DIA for insurance coverage verification.
I do hereby cgqa.r//d,J&��'�un�der the pains and alder o perjury that the informana"provided abotd�ee/is true and correct
S" ate' 1/u� , J � Date' P ///"P—
Phone
r'/"P—
Phone}:413-397-3463
Ojjlclal use only. Do not write in this area,to he completed by city or town official. 't
City or Town: - Permit/License#
Issuing Authority(circle one):
I.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Board 5.SeImtmen's Office
6.Other
Contact Person: Phone#:
www. wviaia
A
5
Measure 11nm —
— �—
�' . 'lli fro,here
O
L}.._ Fireplace Clearances
Fireplace Minimums
Flush Mount 3"Extended Mount
A Mantel 47-112"0207 mm) 441/2"(1130mm)
3"Extended
Flush Mount Mount B Top Trim(1-1/2"I 47-t2"(1201 tern) 3G112"1927 mm)
A Word atFace 2T'(636mm) C SideTdm• 21"(533mon) 21"(533man)
B call at Dimension'C. 22-L2"(572drum 22-112'(572mm) Where side r in metba i 1112138 Y in i ruin Vrs fireplace
lac ng rhe chic-l.man, ,t Le no r s lean v6-112 (673 ma).this is
C Depth 17112"(445mm) 14,12"(368mm) also the regwred r I ,hro,,..
D Height at race 2'-1Y2"(546men) 21-112"(546 man) Measure as We 1r ce(C,I ,in d, rule of your freplaw
E Heigh at Dlmension'C t546ln1n) 21-1p"(548 mm) p a omehe mix fit urea 1 t o)an t, 11 I- -
ences(A)Irom N in, d r .,it[ Yhr Munn, I I I inner clears t;z
Fireplace Maximums (to furnishings.etc.)from lie fireplace(ace.
H Lintel Depth 8-b2"1121 Figure 4-Observe these clearances to combustible trim.
I WidtR 41 (1054 mm7
Unless the fireplace and hearth are constructed over a
a HeighN 28-ll2"O24 mm) completely non-combustible surface (such as unpainted
1. The mmno„indepmmssbr ainamed xem,he,fioorefrhefimplace concrete over dirt). a thermal floor protector must be used
w a heglrl of 21-,:2^!s40 mail in front of and to the sides of the door as protection against
2 T7oeyh the wloreceirer Meant):need mi fit red lamer fireplaces, spilled coals and embers and heat radiated from the front
m it (,heir im v,,om Ca, , Surround Fabels will of the insert. Floor protectors must extend at least 8" (203
not nir eerb wye u)( r t3lot t Lu,orii,, f r dinfird s are manfrom the side of the insert. makingthe protector 44-314"
eedea.t.Uetom made v" o ecm may be Used. )
(1137 mm)wide.
Figure 3-Use these mea sure mentsto wepla that ilia Montpelier
Medium Innen wJl fit info your masonry fireplace. In addition,the floor protector must extend from the front door
opening a minimum of 16"(406 mm)in the United States and
Clearance Requirements 18" (457 mm)in Canada. (Figure 5)
After confirming that your (replace is the right size, check The approved construction of a floor protector calls for a
the clearance tocombustibles.First markwith tapetheexact minimum of 24 gauge galvanized sheet metal or equivalent,
center of your fireplace opening on the hearth. Measure the and the equivalent of 1.25"(32 mm)ofa materialwith k-value
side clearance from this point. Measure the top trim and/or of 0.84 or less.
mantel clearances from the finished hearth surface.Measure
the front clearance (to furnishings. etc.) from the fireplace Custom-made floor protectors may be used if they offer the
face. (Figure 4) same protection. Millboard ties a standard Is value of 0.84
and thus 1-114"(32 mm)of this residual is adequate thermal
Hearth Requirements protection. Custom-built floor protectors must have a to value
I n some fireplaces,the hearth in front of the fireplace opening equal to, or less than 0.84. meaning that heat will transfer
is brick,stone.slate,or some other non-combustible material at the same rate or more slowly than the tested standard.
that is in direct contact with concrete poured overearth.These How to Determine if Alternate Floor Protection Materials
are the only hearths that are considered noncombustible. In are Acceptable
other fireplaces the brick or concrete hearth in front of the
fireplace opening is supported by heavy wooden framing. All floor protection must be noncombustible(i.e.metals brick.
Because neither brick nor concrete has good insulating stone.. mineral fiber boards,etc.).Any organic materials(i.e.
propertiesheat radiated by the fire will pass downward plastics,wood paper products.etc.)are combustible and must
through the hearth to the wooden framing. Such hearths not be used. The floor protection specified
are considered combustible-
7 core, C2sr,gs - Montpelier Medium Insert Installation&no,rn }n nual R20 • An 3-9G-30004x03
EXAMPLE: The specified floor protector should be 1V.
thick material with k-factor of 0,84. The proposed alternate
is 4"brick with an r-fsctor of 0.2 over%l' mineral board with
�a a
Step
k-fas U of o.25
Sten a'.Use formula above 1cOoveY 4yecificatlon to R-value:
58-4
Ste b: Calculate R of proposed system.
4" brick of r-0.2, therefore.
Rn,.rr - 02x4 - 08
e 1/8" mineral board of k-029, therefore
29 x 0.25- 0.431
iR_, - R..,. ' R,, ,r ir��,,.,-0.8 + 0.431 - 1.66
_—_ Step c . .
'.Compare proposed system Rtolal of 1.66 to specified
R of 1.49. Since proposed system Rtolal is greater than
United States Canada requiredthesystem is acceptable.
A' 16"(406 mm) 18"(460 mm) Definitions
B a•(zoamm) e°(zasmm) pr)dr){ F) (ti
C 44-314"(1137 mm) 44-3/4"(1137 mm) Btu k (7)(m)(`F)- Kx12
Type
nor 111Let n.1'ithtte shoe c. rasions 11,11 bere .nd.
e q cy"tor125 (2, 1 111, A- , yral 01,a kvalue 0Mda,e (Btu)(ft) (ft'-)(hr)(T) q
tial iti of 1.491 is noco,ary. K= r-'
ft)(hr)( F) (Bm)(m k
II NP elaaarect 8 1 11e mo mr ie abuse a combustible
md, t .I tett ✓,ded. However. spark and ember
motet n Optional Surround Packages
•u me -sart i, elevated 3 na moil or mor,. wilt me optional hearth Custom-made surround panels may be made from any
o.lnn"oumi, may un reou,-ed to 1e' ;40e mm)(us only) noncombustible material.
heyondwnich no Ihormal proccioe�s,ece sary Vermont Castings offers both steel and cast iron Surround
Figure 5- Unless your fireplace and hearth are constructed over panel kits, each in two sizee
a dat floor f or Un ,1 O ed ccncrote oyer chro you must use a floor Georgian Cast Surround Enclosure Area
proccloi 01,11 satisfies the above regmrements.
30DVSGTKCB,
includes some form of thermal designation such as R-value 30DVSOTKB ...___--.... ...30-1/4"x 41 (768 x 1041 mm)
(thermal resistance) or k-factor(thermal conductivity).
Mead Cast Surround:
Procedure: MEAD3CB _. 28-1/4"x 41-11;16" mm
1. Convert specifications to R-value'. """ 718 x 1059- - ( )
i. R-value given-no conversion needed. Caprice Cast Adjustable Profile Surround:
ii _ _ .. ..._....._... )
. k-fac[aCAPCB.... __ . ... 25' x 35" (635 x 889 mm
'is given with eryuired thickness(T)in inches: Steel Surround:
R=kxT LHE30SS6
. _.27"x 38-1/4" (686X 972 mm)
iii. K-factor is given with a required thickness(T)in inches: LHE30SLB....__.__...._..28-1/4" x41" (718 x 1041 in an)
R Kor12 x
iv.r-factor is given with a required thickness(T)in inches:
R - rxT
2. Determine the R-value of the proposed alternate floor
protector:
i. Use the formula in Step 1 to convert values not
expressed as R.
For multiple layers- add R-values of each layer to
determine overall R-value.
3. If the overall R-value of the system is greater than the
R-value of the specified floor protector- the alternate is
acceptable.
8 Venncnt c,,rgs • Montpelier Medium Insert lnstallation8operating Menual R20 - 041a 3-90-30004403