Shawneen Kocot May 23, 2017
Goggins Real Estate
King Street
Northampton, MA 01060
Subject Location: 83 Emerson Way
Map Block: 36-357
Ms. Kocot,
At your request I have inspected the supporting structure at the rear of 83 Emerson Way and found it to be
deficient. 7S0CMR requires positive attachments at each connection point from footing to rafters.The
connections along the load path from the helical anchors to the floor box are insufficient. I have listed the
required corrections below.
1. Provide appropriate fasteners to connect the helical anchor mounting plates to the three 6 x 6
support post.
2. Provide an adequate designed connector between the top of the three 6 x 6 post and the floor box
above and attach with appropriate fasteners.
3. Provide 4 x 4 diagonal bracing at 45 degrees in two directions at the top of each of the three 6 x 6
post to the floor box above and attach with appropriate fasteners.
The building department cannot design connectors and attachment; however I have included a sample for a
similar application which could be applied to this structure.
Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday
through Friday, 8:30 am to 4:30 pm, except we close for walk-ins at 12:00 noon on Wednesdays. My email
address is: cmillerSnorthamptonma.gov
Thank you for your cooperation on these matters.
7 77
Chuck Miller
City of Northampton
Assistant Commissioner and Zoning Enforcement
INSPECTION REPAIR REQUESTS
83 EMERSON WAY
WINDOWS
- Left front window in the front bedroom and several windows in the master bedroom and
some windows on the porch didn't latch.
Please have the necessary adjustments made prior to closing.
The buyer added,
"For what it's worth, I may know some repair folk who could ta to improve window locking, BUT a
window company that markets and installs "Harvey windows"(??) might be best--or Harvey
Windows, the manufacturer[there might be warranty still in place?]:"
http://vvww.harveybp.com/customer-service/
Their warranty pages:
http://www.harveybp.com/support-center/warranty-information/ Harvey has "20 year
warranty" on some series....
DECK
- Connecting brackets on top of the posts were a configuration from angle brackets for other
applications.
-Connecting bolts were not installed on the base plates.
We are attaching an estimate for the deck support repairs from Budget Remodeling, a company
that the buyer has successfully engaged for work on their current home.
We respectfully request that the seller please engage Budget Remodeling to make the
necessary repairs prior to closing.
RADON
Lastly,the Radon report came back with a reading of 4.6 pCi/L.
The radon average is above the EPA threshold of 4.0 pCi/L for real estate transactions indicating
mitigation is needed at this time.
We respectfully request that the seller please have a Radon Mitigation System installed, and
provide the results of re-testing to confirm that the Radon level is within the EPA guidelines,
prior to closing.
1/43-3P.o l37
JIAa NeemK cora o_
BUDGET REMODELING May 20,2017
P.O. BOX 1038
EASTHAMPTON, MA 01027
(413) 527-5469
John A.Loughney
For:
83 Emerson Way
Northampton,MA 01062
A Finance Charge Of 141% Per Month (18% Per annum) will be
charged on unpaid Eatanees.
DATE CHARGES AND CREDITS BALANCE_
BAt ANCF F-Tit/ arra
TEA Under porch repair/replacements of various floor support hardware
with outdoor versions;install bolts to base of 3 support beams;replace
with galvanized nails/screws along exterior wall;replace upper-brackets
on three support posts.
Hardware:brackets,bolts, 230.00
Labor:4.5 hours 270.00
l TOTAL: $500.00
BUDGET REMODELINGY� .+ Z,' ) /', 1(
PAYABLE APON RECEIPT
ridge vent 5/8" cdx plywood
asphalt/FG shingles -- �
over 11{0 ice/water / 2x10 rafters 24"oc ' '
j. �
5/12 pitch
./J proper vents
r-50 cellulose
-
2x8 collar ties 24" oc soffit vent
1
N
`"
2x6 studs 16" cc i 1St-0" (
/ O
7/16" zip bd sheathing
a)
e-zo (�_ t444) S£
2x12x14 1/2"
blocking i I
I - 3/4" advantec
\I._ 2x12 16"oc with 1/2" plywood on bottom
fill floor with r-40 cellulose
n
_ _ - 10' microhm
N
)90q 01 lir 4 I a“c.I \\f \' / 1 7 1
(eq ca t5 1/2" x14' x 3/16' steel plate
�- -1" • wtih 8- 3" head lock bolts over strip of
-_.2- 8" ledger locks
through bithutare
4x4 pt bracket
6x6 pt posts
INS a ( "11551iii Et calli .
illi sirnpson 6x6 post base ir.
:ow
:At_ 8" anchor bolt
> 1!. g� Get 7 ,er.
i� I .► Existing unused septic tank 1 -
tn �ri 111 /// ( -a_ err '�� ' -3`x4'x4', fill with concrete
r/ ri (`
� Heidi .11.41"°-
r '
-cale 3/8"= 1'0" 4/27/:114