Loading...
36-379 (2) 221 EMERSON WAY BP-2017-1011 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:36-379 CITY OF NORTHAMPTON Lot:-32 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:New Sin_le Family House BUILDING PERMIT Permit# BP-2017-1011 Project 4 JS-2017-000870 Est.Cost: $620400110 Fee: $1768.20 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: STEPHEN FERRARI 98877 Lot Size(sa k Y Owner: BISHOP DAVID R& PATRICIA M GORMAN-BISHOP zz> Applicant: STEPHEN FERRARI AT: 221 EMERSON WAY Applicant Address: Phone: Insurance: 103 RYAN RD (413) 588-8975 O FLORENCEMA01062 ISSUED ON:3/22/201 7 0:00:00 TO PERFORM THE FOLLOWING WORKGCONSTRUCT A NEW 2 STORY WOOD FRAMED SINGLE FAMILY HOUSE WITH ATTACHED GARAGE - 3,083 SQ FT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House N Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 3/22/2017 0:00:00 SI768.20 212 Main Street. Phone(413)587-1240. Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File U BP-2017-1011 ss APPLICANT/CONTACT PERSON STEPHEN FERRARI � 0\(-" d . ADDRESS/PHONE 103 RYAN RD FLORENCE (413)588-8975 0 J if � ��- t „kPROPERTY LOCATION 221 EMERSON WAY v MAP 36 PARCEL 379 32 ZONE 't (� THIS SECTION FOR OFFICIAL USE ONLY: 77 PERMIT APPLICATION CHECKLIST y Eica D REQUIRED DATE ZONING FORM FILLED OUT (�u t VAJ/ Bee Paid 11 Building Permit Filled out \) U Fee Paid Tvpeof Construction: CONSTRUCT A NEW 2 STORY WOOD FRAMED SINGLE FAMILY HOUSE WITH ATTACHED GARAGE-3,083 SO FT New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 98877 3 sets of Plans/Plot Plan THE FLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON IN F MATION PRESENTED: 7Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay Sigrt of But ding S' icial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. Department use only City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit w,pyV� 212 Main Street Sewer/Septic Availability 1 ~ 9 w Room 100 Water/Weft Availability _ - Northampton, MA 01060 Two Sets of Structural Plans 1 __pbaone-413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING pSECTION 1 -SITE INFORMATION 1,1 Procerty Address: This section to be completed by office 221 Emerson Way, Florence Map Lot Unit Zone Overlay District Elm St.District Ca District SECTION 2-PROPERTY OWNERSHIPIAUTHORIZED AGENT 2.1 Owner of Retard: David Bishop&Patricia Gorman-Bishop 124 Turkey Hill RD,Florence,MA Name(Print) Current Mailing Address: 413-584-4507 Telephone Signature Z,2 Authorized Anent: Stephen Ferrari 103 Ryan RD, Florence. MA Name(Print/ Current Mailing Address: 413-588-8975 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building 548,900 (a) Building Permit Fee 2. Electrical ?3,500 (b)Esd ConstructionmatedTotal from Cost(S)of 3. Plumbing 26.000 Building Permit Fee 4. Mechanical(HVAC) �f 5. Fire Protection 22 A)00 U7 1Y Q �-) 6. Total= (1 +2+3 +4+5) 620.400 Check Number 'foci / t7 ,S Va`" This Section For Official Use Only Building Permit Number:_._.,,, IIsssued: Signature: Building Commissionerflnspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size 40.846 sf 40,846 sf Frontage 25' 25' Setbacks Front 55' Side L: R: L:40' k:46 Rear 65' Building Height 26' Bldg. Square Footage % 3083 8% Open Space Footage (Lot area minus bldg&pned 34,562 84% parking) #of Parking Spaces 4 Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DON'T KNOW O YES O IF YES, date issued: 08/11/2016 IF YES: Was the permit recorded at the Registry of Deeds? NO O DON'T KNOW O YES O IF YES: enter Book 128386 Page 45 and/or Document# 00017807 B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. WII the construction activity disturb(clearing,grading, excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House tri Addition [1 Replacement Windows Alteration(s) Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [DI Decks [q Siding[C] Other[CQ Brief Description of Proposed Construct a new 2 story wood framed singe family home with attached garage Work: Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet Ba.If New house and or addition to existing housing, complete the following: a. Use of building : One Family X Two Family Other_... b. Number of rooms in each family unit9 Number of Bathrooms 3'5 c. Is there a garage attached? yes d. Proposed Square footage of new construction. 3083 sr Dimensions 105'-8"x 481-8" Pr. e. Number of stories? 2 f. Method of heating? Air Source Heat Pumps Fireplaces or Woodstoves Yes Number of each 2 g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes X No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k, Will building conform to the Building and Zoning regulations? X Yes No . I. Septic Tank City Sewer 2 Private well City water Supply X SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT i Patricia Garman-Bishop ,as Owner of the subject Property hereby authorize Stephen Ferrari, FCM Smart Build to act on my behalf, in all matters relative to work authorized by this building permit application. c- ""_ — vr5-0347 Signature Owner Date Stephen Ferrari h -- ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate.to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Stephen Ferrari Print Na .6,,••. - %off/ter ? Signature of• nerrelgent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor Not Applicable ❑ Name of License Haider Stephen Ferrari CS-098877 License Number 103 Ryan Road, Florence, MA 01062 5/23/2017 Add s Expiration Date 413-588-8975 Signatur Telephone 3.Registered Home Impr*Vement Contractor: Not Applicable 0 Company Name Registration Number Address Expiration Date Telephone• SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes ❑ No 0 11. — Rome Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(I) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-veer period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for persons) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature _ MUNICIPAL SEWER AVAILABILITY APPLICATION Northampton Streets Department 125 Locust Street Northampton, MA 01060 413-587-1570 A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any construction or connection activity associated with this application. Location: 221 Emerson Way, Lot 32 Date of Inquiry: 09/29;16 Inquirer with contact info: Steve Ferrari 413-588-8975 Reason for Request: New Construction Municipal Sewer Main in Front of Location: Yes No Size of Sewer Main: Material: Age: Depth of Sewer Main: Length of Sewer Main: Size of Service Connection: Type of Service Connection: Tie-in to Sanitary Main: Tie-in to Sanitary Stub: Comments: Private Sewer availability City Requires 6" cleanout installed at City Property Line Note: If this availability is for new construction,this form must be hand delivered to Building Inspector. A corresponding"sewer enterance fee" shall be paid prior to making any connection to the municipal sewer system. Arrangements of such intstailation shall be made with the Northampton Streets Department with a minimum of 5 working days notificaiton. All work shall conform to Northampton Streets Department specifications. Date: .9b Sewer Dept. Foreman MUNICIPAL WATER AVAILABILITY APPLICATION Northampton Water Department 237 Prospect St. Northampton, MA 01060 587-1097 A Department of Public Works Trench Permit shall be required prior to any construction or connection activity associated with this application. Location: 221 Emerson Way, Lot 32 r I Inquiry Made By: Steve Ferrari 413-588-8975 I-- _ I1 9/29/16 Date of Inquiry: 1 I Fire Line Irrigation Domestic X Units: . __. Number ofii Type of Single Family X Type of Private X 1 Unit(s): Apart. Comm. I Ownership: I Condo ,L Multi-family Rental (Anolicant to fill out the above) Municipal Water Main in Existing service to Front of Location? Ycs: No: S11e? Yes: No 1,11-1-.1 / Size of Water Main: Material: A t c. DI e: Z.=g Approximate Static Street Flow Test Conducted: Yes: No: (--"-- Pressure: If done attach results Size of Service Connection I Co er f3 C (. ) S t20 Suggested Meter Size: / meter � _ / ()1 _ I � m Comments: The Water Department cannot guarantee adequate water_' pressure sure during peak demand C1� S/4 times at elevations above 320 feet. t//0 fel mold IS r1at 7L✓.ieel b7 'Re. fi ' .`al- /242/H74+te'0.1 . Seiuite kid? nzY be h'rnzd on col) PC"MP $'h,1r>n /S Yi b • A corresponding water entrance fee shall be paid prior to making any connection to the municipal water system_ • Arrangements of such installation shall be made with the Northampton Water Department with a minimum of 5 working days notification. • All work shall conform to Northampton Water Department specifications. l3 /- /‘ Water Superintendent Date Water Entry S IGO Meter$ 180 Radio $ 135 cc: City of Northampton Building Dept. /Commissioner s4 ,J Note: If this availability is for a new construction,it must be hand delivered to the Building " Inspector. j Building Permit Application Document Index-CD 221 Emerson Way,Florence,MA March 6,2017 Hard Copy File Name Description #of Pages,Size Provided 1 Completed BP App. 221 Emerson Way Completed Building Permit Application 4 pages, letter yes 2 Gorman-Bishop House plan Set 12-19-16 Building and Site Plan set last revised 1249-16 21 pages 36 x 24 yes 3 Stamped Calcs from RK Miles 2-06-17 Stamped Structural Calculations, 13 pages 9 pages,letter 4 Shear Wall Drawing from Bob Leet 2-03-17 Design for Shear Wall ar Kitchen Range Wall 1 page 24 x 18 5 Gorman Bishop 2nd Floor&Roof PP UFP Second Floor&Roof Framing Plans from Universal Forest 2 pages 36 x 24 Products 6 Floor Truss Drawings 12-7-16 2nd Floor Truss Details from UnitedForest Products 9 pages letter 7 Roof Truss Drawings 1-5-16 Roof Truss Details from United Forest Products 23 pages letter 8 Garage Portal Frame Detail J.-20-17 Detail for Garage Door Opening Portal Frame 1 page 11 x 17 9 HERS-814 221 Emerson Way projected Preliminary HERS Rating 1 page letter 10 Sewer&Water Availabilities Notices of Sewer&Water availability from Northampton 2 pages letter yes o City of Northampton 0. " rc , Massachusetts ,.,"- C- <e li "4 ti i DEPARTMENT OF BUILDING INSPECTIONS 2 Z', � - 212 Main Street • Municipal Building C6.,h1�/// C> Northampton, !A 01060 Fee Calculator for Residential Properties Location : d-o / / 41 ed✓Sd'rt L" �2- y Square Footage Amount Basement @ .20 �K t5i, c13o r -16,5— D 0 1ST Floor @ .50 2-0 Coe - 1, 63/ Oa 2nd Floor@ .50 93 (0 y68- 00 '/2 Floors, Finish Attic, Garage @ .20 yo/0/ 1 ?)‘-J O Deck / Porches @ .20 1-1/1 8)-.ef) Total : lT T(' g, X Ciry of Nonhamplon Mail-221 Emerson Way hrtps:/imail.google.com/mail/u/O/ui=2&ik=392 Ilaf 3d&view=pi&se... COofNlon Charles Miller<cmiller@northamptonma.gov> orilwanp 221 Emerson Way 1 message Stephen Ferrari <ferrari.steve@gmail.com> Wee, Mar 22, 2017 at 11:29 AM To: Charles Miller <cmiller@nonhamptonma.gov> Hello Chuck, Here are my responses to your questions marked in RED after each of your comments. Hi, Received the plans and have beam calcs but, need RKs beam layout sheets. Have asked RK for a clean set of plans and will submit them in the next day or two. There are a few items which have come up and I'm sure you'll address. 1. The dryer exhaust is hidden must be labeled per M504.6.5 Will do 2. Braced wall solution are needed at the right front of the garage (included but should have center straps? length limits 18'), the left corner at window #15 and likely the two story stair wall. Bob Leel is working on these issues, will send you his solutions. I assume the issue with the stairwell wall relates to the fact the distance between the front and rear exterior walls in the Kitchen area is greater than 30'. 3. Tempered window are needed at#3, #6, #25, #26, #29 and Hankers at door 001 The minimum distance between the finish floor and the bottom of the glass for windows 3, 25 and 26 will be 61 Y" or more. Do these still need to be tempered? 4. All attic access ways must be 22" x 30" minimum and at the mechanical space the access must be large enough to remove/replace equipment as needed. No Problem 5. The smoke/CO detector outside the master bedroom must be within 10' of the door and another at the bottom of the basement stair. An extra smoke is needed for floors of more than 1200 sq ft. Will do. This will be a monitored full alarm system. 6. Fireplaces require tight filling doors or dampers and make up air to the fire box. The fireplace in the Living'Room is a wood burning insert and will have tight fitting doors and a combustion air intake duct. The fireplace in the I oft 3+222017 12:54 PM City of Northampton Mail-221 Emerson Way https://maiLgoogle.com/mail/u/0/?ui=2&ik=39211at`e3d&view=pt&se_. Dining Room is an enclosed natural gas listed unit. Does this unit require make up air? 7. Section 4 on A3.1 show an incorrect Location of the beam at the stair, section 3 on A3.1 doesn't show the beam. Will submit a revised plan showing the correct beam locations. 8. Section 4 on A3.1 indicates a top hung joist, buts its and Hoist wilt the foundation have a shelf? S1.1 says see the SK, but I do not have it? The joists will be hung on a ledger attached to the foundation wall. Will have Bob Leet submit a stamped detail drawing. Thanks, Steve Ferrari ECM Smart Build 103 Ryan Road Florence, MA 01062 Mobile 413-5HE-3975 Fax 413-506-1832 ferrari.steve@gma Scorn com 2 of 2 3/22/2017 12:54 PM