36-379 (2) 221 EMERSON WAY BP-2017-1011
GIS#: COMMONWEALTH OF MASSACHUSETTS
Map:Block:36-379 CITY OF NORTHAMPTON
Lot:-32 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
Category:New Sin_le Family House BUILDING PERMIT
Permit# BP-2017-1011
Project 4 JS-2017-000870
Est.Cost: $620400110
Fee: $1768.20 PERMISSION IS HEREBY GRANTED TO:
Const. Class: Contractor: License:
Use Group: STEPHEN FERRARI 98877
Lot Size(sa k Y Owner: BISHOP DAVID R& PATRICIA M GORMAN-BISHOP
zz> Applicant: STEPHEN FERRARI
AT: 221 EMERSON WAY
Applicant Address: Phone: Insurance:
103 RYAN RD (413) 588-8975 O
FLORENCEMA01062 ISSUED ON:3/22/201 7 0:00:00
TO PERFORM THE FOLLOWING WORKGCONSTRUCT A NEW 2 STORY WOOD FRAMED
SINGLE FAMILY HOUSE WITH ATTACHED GARAGE - 3,083 SQ FT
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter:
Footings:
Rough: Rough: House N Foundation:
Driveway Final:
Final: Final:
Rough Frame:
Gas: Fire Department Fireplace/Chimney:
Rough: Oil: Insulation:
Final: Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Certificate of Occupancy Signature:
FeeType: Date Paid: Amount:
Building 3/22/2017 0:00:00 SI768.20
212 Main Street. Phone(413)587-1240. Fax: (413)587-1272
Louis Hasbrouck—Building Commissioner
File U BP-2017-1011
ss
APPLICANT/CONTACT PERSON STEPHEN FERRARI � 0\(-" d .
ADDRESS/PHONE 103 RYAN RD FLORENCE (413)588-8975 0 J if
� ��-
t „kPROPERTY LOCATION 221 EMERSON WAY v
MAP 36 PARCEL 379 32 ZONE 't (�
THIS SECTION FOR OFFICIAL USE ONLY: 77
PERMIT APPLICATION CHECKLIST
y
Eica D REQUIRED DATE
ZONING FORM FILLED OUT (�u t VAJ/
Bee Paid 11
Building Permit Filled out \) U
Fee Paid
Tvpeof Construction: CONSTRUCT A NEW 2 STORY WOOD FRAMED SINGLE FAMILY HOUSE WITH
ATTACHED GARAGE-3,083 SO FT
New Construction
Non Structural interior renovations
Addition to Existing
Accessory Structure
Building Plans Included:
Owner/Statement or License 98877
3 sets of Plans/Plot Plan
THE FLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON
IN
F MATION PRESENTED:
7Approved Additional permits required(see below)
PLANNING BOARD PERMIT REQUIRED UNDER:§
Intermediate Project: Site Plan AND/OR Special Permit With Site Plan
Major Project: Site Plan AND/OR Special Permit With Site Plan
ZONING BOARD PERMIT REQUIRED UNDER: §
Finding Special Permit Variance*
Received& Recorded at Registry of Deeds Proof Enclosed
Other Permits Required:
Curb Cut from DPW Water Availability Sewer Availability
Septic Approval Board of Health Well Water Potability Board of Health
Permit from Conservation Commission Permit from CB Architecture Committee
Permit from Elm Street Commission Permit DPW Storm Water Management
Demolition Delay
Sigrt of But ding S' icial Date
Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning
requirements and obtain all required permits from Board of Health,Conservation Commission,Department
of public works and other applicable permit granting authorities.
* Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of
Planning&Development for more information.
Department use only
City of Northampton Status of Permit:
Building Department Curb Cut/Driveway Permit
w,pyV� 212 Main Street Sewer/Septic Availability
1 ~ 9 w Room 100 Water/Weft Availability
_ - Northampton, MA 01060 Two Sets of Structural Plans
1 __pbaone-413-587-1240 Fax 413-587-1272 Plot/Site Plans
Other Specify
APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING
pSECTION 1 -SITE INFORMATION
1,1 Procerty Address: This section to be completed by office
221 Emerson Way, Florence Map Lot Unit
Zone Overlay District
Elm St.District Ca District
SECTION 2-PROPERTY OWNERSHIPIAUTHORIZED AGENT
2.1 Owner of Retard:
David Bishop&Patricia Gorman-Bishop 124 Turkey Hill RD,Florence,MA
Name(Print) Current Mailing Address:
413-584-4507
Telephone
Signature
Z,2 Authorized Anent:
Stephen Ferrari 103 Ryan RD, Florence. MA
Name(Print/ Current Mailing Address:
413-588-8975
Signature Telephone
SECTION 3-ESTIMATED CONSTRUCTION COSTS
item Estimated Cost(Dollars)to be Official Use Only
completed by permit applicant
1. Building 548,900 (a) Building Permit Fee
2. Electrical ?3,500 (b)Esd
ConstructionmatedTotal from Cost(S)of
3. Plumbing 26.000 Building Permit Fee
4. Mechanical(HVAC) �f
5. Fire Protection 22 A)00 U7 1Y Q �-)
6. Total= (1 +2+3 +4+5) 620.400 Check Number 'foci / t7 ,S Va`"
This Section For Official Use Only
Building Permit Number:_._.,,, IIsssued:
Signature:
Building Commissionerflnspector of Buildings Date
Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information
Existing Proposed Required by Zoning
This column to be filled in by
Building Department
Lot Size 40.846 sf 40,846 sf
Frontage 25' 25'
Setbacks Front 55'
Side L: R: L:40' k:46
Rear 65'
Building Height 26'
Bldg. Square Footage % 3083 8%
Open Space Footage
(Lot area minus bldg&pned 34,562 84%
parking)
#of Parking Spaces 4
Fill:
(volume&Location)
A. Has a Special Permit/Variance/Finding ever been issued for/on the site?
NO O DON'T KNOW O YES O
IF YES, date issued: 08/11/2016
IF YES: Was the permit recorded at the Registry of Deeds?
NO O DON'T KNOW O YES O
IF YES: enter Book 128386 Page 45 and/or Document# 00017807
B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES O
IF YES, has a permit been or need to be obtained from the Conservation Commission?
Needs to be obtained O Obtained O , Date Issued:
C. Do any signs exist on the property? YES O NO O
IF YES, describe size, type and location:
D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O
IF YES, describe size, type and location:
E. WII the construction activity disturb(clearing,grading, excavation, or filling)over 1 acre or is it part of a common plan
that will disturb over 1 acre? YES O NO O
IF YES,then a Northampton Storm Water Management Permit from the DPW is required.
SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable)
New House tri Addition [1 Replacement Windows Alteration(s) Roofing ❑
Or Doors 0
Accessory Bldg. ❑ Demolition ❑ New Signs [DI Decks [q Siding[C] Other[CQ
Brief Description of Proposed Construct a new 2 story wood framed singe family home with attached garage
Work:
Alteration of existing bedroom Yes No Adding new bedroom Yes No
Attached Narrative Renovating unfinished basement Yes No
Plans Attached Roll -Sheet
Ba.If New house and or addition to existing housing, complete the following:
a. Use of building : One Family X Two Family Other_...
b. Number of rooms in each family unit9 Number of Bathrooms 3'5
c. Is there a garage attached? yes
d. Proposed Square footage of new construction. 3083 sr Dimensions 105'-8"x 481-8" Pr.
e. Number of stories? 2
f. Method of heating? Air Source Heat Pumps Fireplaces or Woodstoves Yes Number of each 2
g. Energy Conservation Compliance. Masscheck Energy Compliance form attached?
h. Type of construction
i. Is construction within 100 ft. of wetlands? Yes X No. Is construction within 100 yr. floodplain Yes No
j. Depth of basement or cellar floor below finished grade
k, Will building conform to the Building and Zoning regulations? X Yes No .
I. Septic Tank City Sewer 2 Private well City water Supply X
SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN
OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
i Patricia Garman-Bishop ,as Owner of the subject
Property
hereby authorize Stephen Ferrari, FCM Smart Build
to act on my behalf, in all matters relative to work authorized by this building permit application.
c- ""_ — vr5-0347
Signature Owner Date
Stephen Ferrari
h -- ,as Owner/Authorized
Agent hereby declare that the statements and information on the foregoing application are true and accurate.to the best of my knowledge
and belief.
Signed under the pains and penalties of perjury.
Stephen Ferrari
Print Na
.6,,••. - %off/ter ?
Signature of• nerrelgent Date
SECTION 8-CONSTRUCTION SERVICES
8.1 Licensed Construction Supervisor Not Applicable ❑
Name of License Haider Stephen Ferrari CS-098877
License Number
103 Ryan Road, Florence, MA 01062 5/23/2017
Add s Expiration Date
413-588-8975
Signatur Telephone
3.Registered Home Impr*Vement Contractor: Not Applicable 0
Company Name Registration Number
Address Expiration Date
Telephone•
SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result
in the denial of the issuance of the building permit.
Signed Affidavit Attached Yes ❑ No 0
11. — Rome Owner Exemption
The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(I) or two(2)families
and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts
as supervisor.CMR 780, Sixth Edition Section 108.3.5.1.
Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there
is,or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/or farm
structures.A person who constructs more than one home in a two-veer period shall not be considered a homeowner.
Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be
responsible for all such work performed under the building permit.
As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon
completion of the work for which this permit is issued.
Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to
Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for persons)
you hire to perform work for you under this permit.
The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of
Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated.
Homeowner Signature _
MUNICIPAL SEWER AVAILABILITY APPLICATION
Northampton Streets Department
125 Locust Street
Northampton, MA 01060
413-587-1570
A Department of Public Works Trench Permit and Sewer Entry Permit shall be required prior to any
construction or connection activity associated with this application.
Location: 221 Emerson Way, Lot 32
Date of Inquiry: 09/29;16
Inquirer with contact info: Steve Ferrari 413-588-8975
Reason for Request: New Construction
Municipal Sewer Main in Front of Location: Yes No
Size of Sewer Main: Material: Age:
Depth of Sewer Main:
Length of Sewer Main:
Size of Service Connection:
Type of Service Connection:
Tie-in to Sanitary Main: Tie-in to Sanitary Stub:
Comments:
Private Sewer availability
City Requires 6" cleanout installed at City Property Line
Note: If this availability is for new construction,this form must be hand delivered to Building Inspector.
A corresponding"sewer enterance fee" shall be paid prior to making any connection to the
municipal sewer system. Arrangements of such intstailation shall be made with the Northampton
Streets Department with a minimum of 5 working days notificaiton. All work shall conform to
Northampton Streets Department specifications.
Date: .9b
Sewer Dept. Foreman
MUNICIPAL WATER AVAILABILITY APPLICATION
Northampton Water Department
237 Prospect St.
Northampton, MA 01060
587-1097
A Department of Public Works Trench Permit shall be required prior to any construction or
connection activity associated with this application.
Location: 221 Emerson Way, Lot 32
r
I Inquiry Made By: Steve Ferrari 413-588-8975
I-- _
I1
9/29/16
Date of Inquiry: 1 I Fire Line Irrigation Domestic X
Units: . __.
Number ofii Type of Single Family X Type of Private X
1 Unit(s): Apart. Comm. I Ownership: I Condo
,L Multi-family Rental
(Anolicant to fill out the above)
Municipal Water Main in Existing service to
Front of Location? Ycs: No: S11e? Yes: No 1,11-1-.1
/
Size of Water Main: Material: A t c.
DI e: Z.=g
Approximate Static Street Flow Test Conducted: Yes: No: (--"--
Pressure: If done attach results
Size of Service Connection I Co er f3 C (. ) S t20
Suggested Meter Size: / meter � _ / ()1 _ I � m
Comments: The Water Department cannot guarantee adequate water_' pressure sure during peak demand C1�
S/4
times at elevations above 320 feet. t//0 fel mold IS r1at 7L✓.ieel b7 'Re. fi '
.`al- /242/H74+te'0.1 . Seiuite kid? nzY be h'rnzd on col) PC"MP $'h,1r>n /S Yi b
• A corresponding water entrance fee shall be paid prior to making any connection to the municipal water
system_
• Arrangements of such installation shall be made with the Northampton Water Department with a minimum
of 5 working days notification.
• All work shall conform to Northampton Water Department specifications.
l3 /- /‘
Water Superintendent Date
Water Entry S IGO Meter$ 180 Radio $ 135
cc: City of Northampton Building Dept. /Commissioner s4
,J
Note: If this availability is for a new construction,it must be hand delivered to the Building "
Inspector. j
Building Permit Application Document Index-CD
221 Emerson Way,Florence,MA
March 6,2017
Hard Copy
File Name Description #of Pages,Size Provided
1 Completed BP App. 221 Emerson Way Completed Building Permit Application 4 pages, letter yes
2 Gorman-Bishop House plan Set 12-19-16 Building and Site Plan set last revised 1249-16 21 pages 36 x 24 yes
3 Stamped Calcs from RK Miles 2-06-17 Stamped Structural Calculations, 13 pages 9 pages,letter
4 Shear Wall Drawing from Bob Leet 2-03-17 Design for Shear Wall ar Kitchen Range Wall 1 page 24 x 18
5 Gorman Bishop 2nd Floor&Roof PP UFP Second Floor&Roof Framing Plans from Universal Forest 2 pages 36 x 24
Products
6 Floor Truss Drawings 12-7-16 2nd Floor Truss Details from UnitedForest Products 9 pages letter
7 Roof Truss Drawings 1-5-16 Roof Truss Details from United Forest Products 23 pages letter
8 Garage Portal Frame Detail J.-20-17 Detail for Garage Door Opening Portal Frame 1 page 11 x 17
9 HERS-814 221 Emerson Way projected Preliminary HERS Rating 1 page letter
10 Sewer&Water Availabilities
Notices of Sewer&Water availability from Northampton 2 pages letter yes
o City of Northampton
0.
" rc
, Massachusetts ,.,"- C- <e
li "4 ti i
DEPARTMENT OF BUILDING INSPECTIONS 2 Z',
� - 212 Main Street • Municipal Building C6.,h1�/// C>
Northampton, !A 01060
Fee Calculator for Residential Properties
Location : d-o / / 41 ed✓Sd'rt L" �2- y
Square Footage Amount
Basement @ .20 �K t5i, c13o r -16,5— D 0
1ST Floor @ .50 2-0 Coe - 1, 63/ Oa
2nd Floor@ .50 93 (0 y68- 00
'/2 Floors, Finish Attic, Garage @ .20 yo/0/ 1 ?)‘-J O
Deck / Porches @ .20 1-1/1 8)-.ef)
Total : lT T(' g, X
Ciry of Nonhamplon Mail-221 Emerson Way hrtps:/imail.google.com/mail/u/O/ui=2&ik=392 Ilaf 3d&view=pi&se...
COofNlon Charles Miller<cmiller@northamptonma.gov>
orilwanp
221 Emerson Way
1 message
Stephen Ferrari <ferrari.steve@gmail.com> Wee, Mar 22, 2017 at 11:29 AM
To: Charles Miller <cmiller@nonhamptonma.gov>
Hello Chuck,
Here are my responses to your questions marked in RED after each of your comments.
Hi,
Received the plans and have beam calcs but, need RKs beam layout sheets.
Have asked RK for a clean
set of plans and will submit them in the next day or two.
There are a few items which have come up and I'm sure you'll address.
1. The dryer exhaust is hidden must be labeled per M504.6.5 Will do
2. Braced wall solution are needed at the right front of the
garage (included but should have center straps? length limits
18'), the left corner at window #15 and likely the two story stair
wall. Bob Leel is working on these issues, will send you his
solutions. I assume the issue with the stairwell wall relates to
the fact the distance between the front and rear exterior walls
in the Kitchen area is greater than 30'.
3. Tempered window are needed at#3, #6, #25, #26, #29 and Hankers at
door 001
The minimum distance between the finish floor and the bottom of the
glass for windows 3,
25 and 26 will be 61 Y" or more. Do these still need to be tempered?
4. All attic access ways must be 22" x 30" minimum and at the
mechanical space the access must be large enough to
remove/replace equipment as needed. No Problem
5. The smoke/CO detector outside the master bedroom must be within
10' of the door and
another at the bottom of the basement stair. An extra smoke
is needed for floors of more than 1200 sq ft. Will do. This
will be a monitored full alarm system.
6. Fireplaces require tight filling doors or dampers and make up air to the
fire box.
The fireplace in the Living'Room is a wood burning insert and will have
tight fitting doors and a combustion air intake duct. The fireplace in the
I oft 3+222017 12:54 PM
City of Northampton Mail-221 Emerson Way https://maiLgoogle.com/mail/u/0/?ui=2&ik=39211at`e3d&view=pt&se_.
Dining Room is an enclosed
natural gas listed unit. Does this unit require make up air?
7. Section 4 on A3.1 show an incorrect Location of the
beam at the stair, section 3 on A3.1 doesn't show the
beam. Will submit a revised plan showing the correct
beam locations.
8. Section 4 on A3.1 indicates a top hung joist, buts its and Hoist wilt the
foundation have a
shelf? S1.1 says see the SK, but I do not have it? The joists will be
hung on a ledger attached to the foundation wall. Will have Bob Leet
submit a stamped detail drawing.
Thanks,
Steve Ferrari
ECM Smart Build
103 Ryan Road
Florence, MA 01062
Mobile 413-5HE-3975
Fax 413-506-1832
ferrari.steve@gma Scorn
com