Loading...
60-62 Letter 2003 July 10,2003 INSPECTOR (City of 311ort4antpfon Alassaobusetts DEPARTMENT OF BUIID/NG INSPECTIONS 212 Main Street • Municipal Building Northampton, MA 01060 Gary Cadette 60-62 Market Street Northampton,MA 01060 3244 -/00 Building Permit BP-2004-0026 for deck on roof Dear.Mr.Cadette, I made a site inspection this morning to 62 Market Street for the deck that you had constructed prior to obtaining building permit.I failed the inspection for the following reasons: a. The deck construction and plans must be stamped by a structural engineer.The lmeewall that is supporting the front portion of the deck appears to be out of plumb and leaning forward. The method of attachment of the ledger to the house side is made with what appears to be'''/" lag bolts which I want a structural engineer to verify is sufficient to maintain the 601b load the state building code requires. b. The deck is within two feet of a chimney which is a violation of Massachusetts State building code section 3610.2.5(copy attached)which states a chimney shall extend at least two feet higher than any portion of the building within ten feet.. The deck should not be used until you have a structural engineer verify that it is sufficient to maintain the loads required.Decks can very easily be overloaded and in extreme instances failure results in collapse with potential injury or loss of life resulting.Please contact this office upon receipt of this letter with you plans to make corrections.The building permit will not be signed off until such time as corrections are made.Failure on your part to take any action to correct the problem will reslut in this office proceeding to housing court for enforcement. I am forwarding a copy of this letter to the Board of Health for their records. If you have any questions please feel free to contact me at 587-1240. Sincerely, Anthony Patillo Building Commissioner City of Northampton