Loading...
24D-115 SIrI Nu 2 D +r_ Dear Building dept iyIs The following plans for the solar install have been redesigned for / 19 Church St, X146 for the following reasons I 1 Upsized the system Lo reach 100% offset. Added modules Co MP4 Please add to permit already issued jdipadua@solarcity.com Thank You ////���� Jim DiPadua / Jim DiPadua Project Manager I SolarCity ni 978.8477170 SolarCity HIC 120572/MA LIG I116MR ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID-INTERTIED VIA A AC ALTERNATING CURRENT UL-LISTED POWER-CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY-RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL UST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPUANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE CND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Ise SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW REUEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT II 3R NEMA 3R, RAINT1GHT 1 1 „ PV1 COVER SHEET 1 PV2 SITE PLAN 01 PV3 STRUCTURAL VIEWS k , PV4CutTHR E LINE DIAGRAM LICENSE GENERAL NOTES �' L I GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION , ✓.. ELEC 1136 MR OF THE MA STATE BUILDING CODE. k 2. ALL ELECTRICAL WORK SHALL COMPLY WITH - y' THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. ' . '" MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Northampton - REV BY DATE COMMENTS ®®LLA7/ZO1 SYSTEM UPSIZE U� * UTILITY: National Grid USA (Massachusetts Electric) 'r Goo le ���i B-01 n . . ;�n { 1.11 :[ - _1 1, :_7 -a CONT o SHALL OT BE E USED 11IN !CB MEM JU-0� 02440 Q� PKAEONNER OK11reN a5IX ,��NAS��d�C�ty. BENEHT O ANY EOE NETS FOR 1RE KAREN BELLAVANCE—GRACE Karen Bellavance—Grace RESIDENCE Smith Johnston BFNEFli 6 ANYONE IXfEPi IN 4Ott INC., MOWING 55811: r"U Nal 9O O N BE DISCLOSED IN MISE OR IN Comp Mount Type C 19 CHURCH ST 5.2 KW PV ARRAY PART TO()TIERS OUTSIDE THE RECIPIENTS NORTHAMPTON, MA 01060 CRCAMIATIag, x CONIECCON MIN WOOLS. NE SALE N:o USE USE a NE RESffIIK (20(20)e ) REC # REC260PEZ2I St Malin Drive,Balding 2.Unit II SIXMOTY EQUIPMENT, MINIMPIE MINN N1Rlaf PAGENNE. NM:: REV DAN' is (650)638-1028 Marlborough, MA(650)01752 6X-10]9 PERMISSION OF SOLARCITY INC SOLAREDGE ;sE5000A-USOOOSNR2 COVER SHEET PV 1 a 11/17/2016 cBBBrset-alY(MN-2481) .n vlartllNxT PITCH: ARRAY PITCH:31 MP2 AZIMUTH:265 ARRAY AZIMUTH:265 MATERIAL:Comp Shingle STORY: 1 Story ° A PITCH:31 ARRAY PITCH:31 MP3 AZIMUTH:3816 ARRAY AZIMUTH:86 ISI MATERIAL: Comp Shingle STORY: 2+Stories a PITCH: 31 ARRAY PITCH:31 Og MP4 AZIMUTH:266 ARRAY AZIMUTH:266 D E,19N MATERIAL:Comp Shingle STORY: 2+ Stories .. V - a5 Si _ d' ES H. sc I CHILDS m CIVIL w ® No.52764 a 9 r P� O 90n. S2ONAL 6 E� FS3/ONAI Et'�C'\� 3LEGEND N Digi Ealy signed by James H.Ch' ds, P.E. Date 2016.11.17 19:40:35 -08'01' 0 (E) UTILITY METER & WARNING LABEL ® .. .. O INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS p.T DC DISCONNECT & WARNING LABELS AC H---1 3 A AC DISCONNECT & WARNING LABELS 0 DC JUNCTION/COMBINER BOX & LABELS B i iD\/ i 0 DISTRIBUTION PANEL & LABELS m LOAD CENTER & WARNING LABELS \ O DEDICATED PV SYSTEM METER am RAPID SHUTDOWN ' Front Of House STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR � --^ CONDUIT RUN ON INTERIOR - 0-' - (E) DRIVEWAY GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED rc` INTERIOR EQUIPMENT IS DASHED 19 Church St SITE PLAN N ` Scale: 1/8" = 1' w -� [ 01' 8' 16' CONFIDENTIAL- ME INFORMATION HEREIN JOB NUMBER' JB-0102440 00 PREMISE DIRPR OK Karen DESIGN: CONTAINED SHALL NOT DE USED FOR ME KAREN BELLAVANCE—GRACEN+. BENEFIT or ANYONE EXCEPTsaARary INC.. MCUNINDsYSIFIA Karen PV ARRAYGrace RESIDENCE smith JohnstonJohnStofl } NOR SHALL IT 9E DISCLOSED IN RAMIE OR IN Com Mount Type C 19 CHURCH ST 5.2 KW PV li'I olar Y. PART 10OTHERS WNI THE REaplw1's NODME� NORTHAMPTON, MA 01060 HSALE MID F 11 E RESPEO4 Will # THE MM USE OF 1HE RESPECn+£ (20) REC REC26OPEZ 24 St uwlb oT.,Bolding 2 W x II SCUMMY EQUIPMENT, MT OJT ME WRITTEN PAM NAME: SHEEP RET` DAM 638-1028 MA 01752 PERMISSION a STI AMITY INC. SOLAREDGE SE5000A-USOOOSNR2 SITE PLAN PV 2 0 11/17 2016 T. (650)638-1028 ntsx-LD2s M / (888}S0.-OTY(765-2489) malardtmcom fix ! � /A ® / 3�vt �� •Syc (E) 2x8 �x 4CHIL H. tiG ' 41110 o/CHILDS y CIVIL 527�/ No . 52764mg90 A- 0,r9F0IS-fSO'' 4..`�S/ONAL ENx' Ii 0'-1"1'-M�', (E) LBW ,0<d„„,,..AY �I 12._4. 1 (E) LBW iB� SIDE VIEW OF MP2 NTS A (E) LBW 14' MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES CI SIDE VIEW OF MP3 NTS LANDSCAPE 62" 24" 39" Cr STAGGERED MP3 X-SPACING %CANTILEVER V-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 29" 39" 0" STAGGERED PORTRAIT 52" 20" 65" 0" PORTRAIT 48" ROOF AZI 265 PITCH 31 ROOF AZI 86 PITCH 31 RAFTER 2"XS" @ 26" OC ARRAY AZI 265 PITCH 31 STORIES: 1 RARER 2x8 @ 29"OC ARRAY AZI 86 PITCH 31 STORIES:2+ C.J. 2"x6" @26" OC Comp Shingle-Skip Sheathing Comp Shingle PV MODULE '` 5/16" BOLT WITH INSTALLATION ORDERA (E) 2x8 `\ FENDER WASHERS � LOCATE RAFTER, MARK HOLE //�A�\ ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT 7 \ / ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH ) ZEP COMP MOUNT C POLYURETHANE SEALANT. ® / {UMU►nMIYFF sFFFFI 'UUUUUIyyIZEP FLASHING C 'oalinimn (3) INSERT FLASHING.t��r(E) COMP. SHINGLE ! E� �Y. 4' I in(4) PLACE MOUNT.rrAbal 111M (E) ROOF DECKING (1) INSTALL LAG BOLT WITH (E) LBW 5/16" DIA STAINLESS (5) SEALING WASHERWASHER STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH C D SIDE VIEW OF MP4 NTS WITH SEALING WASHER C D (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. J (E) RAFTER MP4 X-SPACING X-CANTILEVER V-SPACING V-CANTILEVER NOTES S i STANDOFF LANDSCAPE 72" 24" 39" STAGGERED 1 0PORTRAIT 48" 19" 65" 0" Scale: 1 1/2" = 1' ROOF AZI 266 PITCH 31 RAFTER 2x8 @ 24" OC ARRAY AZI 266 PITCH 31 STORIES:2+ /� /� Comp Shingle CONFIDENTIAL- THE INFORM/MON HPSN Qb AMBER: JB-0102440 O O PREMISE MR �i A ���i �/ �/ �i A —g[9aE�f`� .���A � -/ CONTAINED SHALL NOT 9E USED FOR THE KAREN BELLAVANCE—GRACE �eE•t. DEFbnr a.WYONEE#EPT SOLARCITY INC.. MON11CSSK : Karen Belt/ ARRAYe-Grace RESIDENCE Smith Johnston SolarCity NOR SHALL R DE DISCLOSED IN YNCRE OR IN CompMount Type C 19 CHURCH ST "a PART TO OTHERS OUTSIDE THE RECIPIENTS 5.2 KW PV rgA oRCANunax, ExPEPT N CONNECTOR wTx 11NIMfy NORTHAMPTON, MA 01060 THE SALE AND USE OF THE RESFEC1K (20) REC ft REC260PEZ 24 s.Moth DLL.,&Aleg s,um 11 SCIgRQTT EQUIPMENT,INTHOUT PIE NRITIFN PMF WE 9HR: RE'F DAIS Nabwwgh,MA 01752 PERMISSION OF 1 Urr INC. SOLAREDGE fSE5000A-US000SNR2 STRUCTURAL VIEWS PV 3 a 11/17/2016 * (9w)sx-io2e e (ew^sx-ton (688)-sQ-CITY(165-2499) . w><IUYmn / GROUND SPEC MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BONO (N) #8 GEC TO TWO (N) GROUND Panel Number:LC120DF Inv 1: DC Ungrounded INV 1 -(1)SOLAREDGE ysE5000A-USOOOSNR2 LABEL:, A -(20)REC REC260PEZ GEN #168572 \--RODS AT PANEL WIN IRREVERSIBLE CRIMP Meter Number:97063455 Inverter: 5000W, 240V, 97.5% w/Unifed Disco and ZB,RGM,AFCI PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled ELEC 1136 MR ) C Overhead Service Entrance INV 2 INV 3 Vo 37.8 Vpmax 07 Ise AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER 11 / ((E)) 125A MAIN SERNCE PANELA (E) 100A/2P MAIN CIRCUIT BREAKER Inverter 1 (E) WIRING CUTLER-HAMMER \ 100A 2P Disconnect z SOLAREDGE / / SE5000A-US000SNR2 LOMB I A N /1J J �.. ❑ 30A/2PIsol bl eam w�_om a. oc� GEL 1 ( MP3, MP4,MP2: ( UNREM oo EEGG GG 1x20 v / 1 N / GCGEC \ )V / \ TO 120/240V `- GES T / SINGLE PHASE UTUTY OUNCE / I N / _a__i__ / ) ( h PHOTO VOLTAIC SYSTEM EQUIPPED WRAPID SHUTDOWN 1J / J \ 1 J Voc = MAX VOC Al MIN TEMP \ ,,c T (I)MJRRAY#MP230 PV BACNEIID BREAKER A —(1)CU,11ER-HANYFA .9y21 RB /L/' x�`, OO)SOURFOGE P]0o-5NM4Z5 / Ol Brzdx. LOA/2P. 2 spaces Diemx,eal; 30A, 24OVac,Nm-Fusible, NEMA 3R /'1l. r V Pore,Box�llmuv;]001Y, ZFP, n MC4,aut MCI DC 1\ -(2) Rtl xo# -(I)(1)CURER-HAMMER //OGOA, ((•J•n (I)AMG/6, Sditl Bare Copper / yG55o/BBy r B, C awn#/xa4d Mt 30A, General Duty(0C) -(z) Breaker: sal F-ISA/IP. I swm,a,al -(I) / (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 11 • K OIOF(. _ . . T(1)AWC Pa, IN BlackBlack _ .. ..._.._ .. (z)AWG p /fire,PV ,e.6adV;elanvoce =5ao5oe Ttt -ts ADCl \ (I)AWG pit 1xVM-z,Red O (I)ANG f6 Solid Bore copper ECG Vmp =350 VDC Imp=14.66 ACC \ / L-(1)AWG n0. THYM-2 1.1115e NEUTRAL Vmp =240 VAC Imp=21 MC F1(I)Cmdun Kit: 3/C EMT (i)AWC j9, IHYM-z &sen EGCLGEC (1)Conduit.Mil.?L4' EMI / \ 1 C \ / PFEMSE OMR CESaRna1: uza1: l/'' // C WJNEDS- MEInEwU 0FHEREH .mMIIeYH: JB-0102440 00N�„SOIarVgty ) oxlaxED uxmR u5D GR HE KAREN BELLAVANCE—GRACE Karen Beavance Grace RESIDENCE Smith Johnstondonnston BENEAT Cf ANYgY E%CEPT SIXARatt INC" IOJNIHG SYSTEM: �••,x / xw 91AfL(PRE DIALOEEDIwO.r aRl Comp Mount Type C 19 CHURCH ST 5.2 KW PV ARRAY PART To OTHERS OUTSIDE NE RECIPIENT'S MmwEs NORTHAMPTON, MA 01060 \ ORGAMZ 110N UDEN IN CONNECTION VAN z4 St Marlin pie,Bulling 2.UM u THE SALE AND USE Of NE RESPECPS£ (20) REC # REC260PEZ PA NAIL gIEET: 4 FEV BATF: MVHwave,MA 01752 PERMISSICNEDEI SCYPRCITY INC. THE WRITTEN HIERIER: PV Q 11/17 2D16 (�}(9Y'ary�IO2F24E�(8�m8MY-IMIB SOLAREDGE jSE5000A-US000SNR2 THREE LINE DIAGRAM WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: Label Location: Label Location: (C)(CB) WARNING (AC)(P01) WARNING (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 ELECTRIC SHOCK HAZARD NEC 690.17.E ELECTRIC SHOCK HAZARD NEC 690.35F DO NOT TOUCH TERMINALS THE DC CONDUCTORS OF THIS 690.35(F) Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC (DC) (INV) LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND NVERTER is DISCONNECT Per Code: IN THE OPEN POSITION MAY BE ENERGIZED UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: PHOTOVOLTAIC POINT OF (P01) INTERCONNECTION MAXIMUM POWER-MA (DC)(INV) Per Code: POINT CURRENT.1mo) Per Code: WARNING:ARDO ELECTRICOT UCH NEC 690.17.4; NEC 690.54 MAXIMUM POWER- HAZARD. DO NOT TOUCH POINT VOLTAGE(Vmp)_V NEC 690.53 TERMINALS.TERMINALS ON MAXIMUM SYSTEh1 BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)w MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT_ POSITION FOR SERVICE CURRENT(Isc) A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC 1111. A OPERATING CURRENT MAXIMUM AC V Label Location: OPERATING VOLTAGE WARNING (DC)(INV) ELECTRIC SHOCK HAZARD Per Code: IF A GROUND FAULT IS INDICATED NEC 690.5(C) NORMALLY GROUNDED Label Location: UNGROOU DEDANDENERGIZED CAUTION (P01) DUAL POWER SOURCE Per Code: SECOND SOURCE IS NEC 690.64.6.4 PHOTOVOLTAIC SYSTEM Label Location: WARNING (DC)(CB) ELECTRICAL.SHOCK HAZARD Per Code: Label Location: DO NOT TOUCH TERMINALS NEC 690.17(4) CAUTION (D) (P01) TERMINALS ON BOTH LINE AND Per Code. LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM IN THE OPEN POSITION CIRCUIT IS BACKFED NEC 690.64.6.4 DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGNIT Label Location: WARNING (PO1) INVERTER OUTPUT Per Code: Label Location: CONNECTION NEC 690.64.8.7 PHOTOVOLTAIC AC (AC) (P01) DO NOT RFLOCATE (AC):AC Disconnect THIS OVERCURRENT DISCONNECT Per Code. DEVICE (C):Conduit NEC 690.14.C.2 (CB):Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC -A (AC) (P01) (LC): Load Center - OPERATING CURRENT Per Code: MAXIMUM Ac _ v NEC 690.54 (M): Utility Meter OPERATING VOLTAGE (P01): Point of Interconnection CVIIGfN¶K -THE INFORmADON HEREIN CgRNNED SHALL NOT BE USED FOR :,��/ 3055 UeaMew Way ME BENEFIT OF ANYONE EXCEPT SW2CITY INC..NOR SHALL IT BE OISCEOSED `s e' San Mateo,CA 99402 IN MOLE OR IN PART TO OTHERS OUTSIDE 1HE REPPENT'S OIIDANIZAHOR. Label Set '°j5`SolarCity 6(650)63&1028 F;(616)638.1029 EXCEPT M CONNECRON YAM ME SALE AND USE OF IME RESPECTIVE �I� 0688)-SO2 CITY(765-2489)wwwsolmdb.wm SCARCITY EQUIPMENT. MMWT THE N IBth PERMISSION OF SGMCOTY WC. 3'^SolacCity Zep Solar Next-Level PV Mounting Technology 'y,SOlafCity Z pSlar Next-Level PV Mounting Technology Components . Zep System qqq ___��� for composition shingle roofs `� M� II UP-roof L Leveling Foot woumxro rn ^^ `� Part No.850-1172 Leveling Foot - ETL listed to UL / .._ -.*I Ili S= E 1111161*All rit ' a eenT ,ay aunt Comp Mount Part No.8501382 Listed to UL 2582 Mounting Block Listed to UL 2703. -. agents p (a Description TIMM6 .84 W mo nt 9 solution for post on sM1ingle roofs ���,,,... • ? , • Works with all Zep Compatible Modules _� onv> • Auto bonding UL-gated hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1 o Type 2" Interlock Ground Zep V2 DC Wire Clip UL LIMO Specifications Part No 8561388 Part No.856-1511 Pad No.850-1440 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to uL 1565 Designed r pitched roofs portrait - - - - Installs in portrait and landscape orientations and System supports module wind uplift and snow load pressures to 50 psf per UL 1703 Wind tunnel report to ASCE 7-05 and 7-10 standards 1101 Zep System grounding products are UL listed to UL 2703 and UL 467 Zep System bonding products are UL listed to UL 2703 j•. Engineered for spans up to 72"and cantilevers up to 24" iikSi , Zep wire management products listed to UL 1565 for wire positioning devices /1 Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip,End Caps Part Ms.850-0113 8561421, 850-1460,850-1467 zepsolarcom zePsolar com Listed to UL 1565 This document does not create any express warranty by Zep solar or abounds products or nommen Zee Solara sole wan-NO is contained m tre written IttoMINI ammant2 wardocument dose not create any express warranty by zap Solar v about 45121ducts or servime.Zep radars somwarranty is contained in the Moan product warranfor each product a amn snpped+h Oen Solar products - thesole ! mNerreao rte productis solelyThis roshipped sl constitutes sole roa en a product wane.*The customer is solely responsie for verifying On suitability oto pSole r prod uds fuse.Specificabonsbloc to change withoutnonce.Pate Ms and App Zapatac . eachspmsbe r venvynahe suitability of Zep Solar a pram/act foreach use, we.nmtons are subject m change winded carve.Pabis 0-e Apps ?seas corn. oozment A 801a9040l Rev A Data last exported November 13,2015221 PM Document#&J0-1890001 Rev A Dale last expected;November 13.2015223 PM ENERGIZING LIFE TOGETHER A RCC HIGH PERFORMANCE i � SOLAR PANELS EFFCE ICY RSC PEAK ' YEAR PRrntri YEAR u�na ENERGY ' CB :„,eao vTY ^/ the perfect iteber ssanels ere �. erwawlaPat.urgt llr>rao.r>unr n esG.40%fl 8Y s — TpT tUrGYVYklgatMP%, a<ux/'t .. P ng arry.nrureCeem8mtwrrc 6z3MK systems that cornbine tangiest ea imuisaimmimmillgigillillealligitillitialr>m{wt>tyncaAMflMPoflw. cqu%n product quality with reliablepowetoutput r / '""""' ""` REC cdlnbines high quality ij@yign1 'd �; n we '„,.Ovrl 255 COzzes £ellrypn yJpP;RFmuM6ervsu@rn menet actoringstanderds to produce high- WanCarpo or s age �s s s 3>ttuigcalxmzu wnq eYpenandzz performance solar panelseeth / Nom nolrowory tope 'am eo/ qOg Glass T 'mmmlargle>awnM1pgipt>ftgn uncomproml5lggqualltk N IPow erc a :.„IA; a42 e o o3e ecks eb .Doublehvwh r 4tktt p>tye>ter Ci c VOL"ge nA„Ivl 3zs ms 361 7rame A>16411MaWlMn:::::” i� / c c L AI es' dal oe 3epG, ov.c9op ti it `G. r IF Iwl 1ss lwrznonBan. IPR3raHd / Jfti-C (N�hW 4➢` lmttam MPnzCulbetHbl(}mroai (a • m.maa"cepa sand n 2s.am,a aa,ea pa. . ." a, a a. orwat N>dN +Nng wre r�PIR4.ofA /- No nao owe r olta -p� I93 I9 202 qu>YQuiyt4Haplt4lm�r N IPow a-r acVm,lvl z6; z99 294 MCMIXWb$YftarnaM1d$C V N Iv c IAI 0n 60I Gcc Dezientowl sorw P.U°p4(0 fir". �. or • a man VO m r mn a mN. .nw m mI a ea4 m 3G�Ma1i4M6ilaM1ott via M>¢9¢rygPwnHWn$ uto ” na bbaPewnecwrentr r 55A t4wMMr Mt7YM / / / Y(r1Y�IH !tl$AL '/ / r u�rvn ro. unr a a / / !/ 1 . a rsa olmemwn> 550>}yAllaHtlkANt§eli9flmnS . / 25yea run i. > n Are Rktl ln'1 "na/ / /' / 1 a.deg of 017%p3 4 wknt HW>tigINV ' // / NNM AUS pacific eb rcwbjeattarhiug. ItpNt lotto an "Sae Ytirlo / NH. gglblp gy -p M1 y- ( pe ofn .ut bl I' h "g mi �;' / ra Ylgn r pl l nvpo.a Ir eLener ��� / / / / 1 18 g Y I. 9FP 11 rwlnNw a"4 a s el onb0 I kg I a Le(I rkei RFCell Nu 1600 / / / / / �` �` / c��kloree wnw eee e,ame euee Ius/c4/ Ilmn.n ml3 ww recgm"Prem // j i Sour - . • . SelarEd v7 9e Single Phase S 0000aorth America Inverters solar ' • • Single Phase SF1fi00A-USr OPA-US/SE11400 S OOOA-US r SE3 us se/eaon tt- oS'sto Inverters for aoa to America US/SE IS SE100 A-U /SE6 oNTour A-US r � n. we nvrl.r 'cvecaaus °f�A 0A On A-(IS ir. M n Il5J cc D vv a eYv[ 3000 1890 -C64'OOA.VS SF]MbA us g ehA '3C0 0.b SE]gpeA 62 W € co SEIIppeA US ?'^ Ms 480 :32:,83,V +�2VeV /6Po 9934 p]gI 1 l^3nUGao0 e rxOV •1r` gy .ircX ^►- CI ) ]5 V.M ✓ 6350 W 0. ll00J .Oi. M �F 20&V V4 1 J➢rc 09rugyS40Y 11000 nue c,i 1 s ✓ ✓ vn m ¢s rM„ of Maui a 2 r M a n.1m.rn M 4( 1 a r r rl °1 r .,Idm 3 ( av la Gear e 1 s osv 2aav VS rvy e ,da sLoo ro, n rip, a ror we Cmr , 95 1 tr 3 lvoi Y It 81, r) U)90V W 19 g5 n Yny 3 33Z 99v 'e Y IC5 Y 9Lr i3 30;( / We nm • Mgl2 l 1 ab fido 9 A60 ZONAL fEAt11REf 96 ➢ a e� .ve rca NC"24 9a 98 311 rr il x tl3h ANV 1P.I 9l/113399 alkild lailliilial STANDARDNr 1490][ RS985N' lY 9>5 pl, COMPLIANCE I Ym,lte ' 8 (r P,Utf •a . I a , wnr-mr AwmWINS.T"A'rvn4:oc1.A3r mwFie On rN SPECIFICATIONS pECIFICATIONS rvxn/3ae 'Ua1aLJ, In IsMhm/A-/1 w<<rl 1112 4 a weEO 33/ .vaL,.6v.selryfi l4 l J3Uvnoqn➢ka l a/ 1rJIInMdw�i=a ie/a 8hr;e3 nrc N V""ml 3M96919 pe os, vyy e tlJ;�nk1 S /'; , ' ae x "/m30 1, mnon best CH or SolarEdge enabledy ' x,eaIOtegrattdate�toR(NOP 1 /aNEC0116gosst 93 — r. 21�,tPllan{y 24 tlA� AaPBrlweHlency(%%) mH ag NEM/3Arr Snailpetit�1&htyM easy to lrutaion pro bracket BUAbI module,yvelnonrtarmg nynintern'wnnecv though Ethernet or Wireless aindoPr nxta(VaHPnrlxetl voltage inverteraC}ACcomers lon onlYsassembkdsakth for raserlonaiUttoKGrevenue evenu &'tide dataANS,Cl2 3 n a - . . aro r J!'iY pLAW. LR v r,T r MWW_4611 Ctl$(._VS E14 �; alRaHS cc solar w solar SolarEdge Power Optimizer - Zep CompatibleTM' N Module Add-On For North America 1)300-ZEP SolarEdge Power Optimizer - 2 P300-ZEP(far60-cellPV modules) INPUT Zep CompatibleTM Module Add-On I— Ralndlnput DCpower I 100 W Absolute MiTxiriujrri input Voltage(go( it l empelawm) 48 vac CL For North America P300-ZEP MRPT Operating Range F .0 V&0 Maxirnwn DC rt Cil cuRCmrcn118cf 1.. Ark Mnxrtnum DC Input Curren! t3.S Ath Maximum I Irmenry 99.i % Weighted EMtiency 988 LL— Overy ll IeCateyory II W OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) PAS/11111L1111 OutputtV Current 6` Ade Mrzim Output V ge 60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) [ 0 story rant Val g.per l own=ul mazer 1 Viii ‘'t #t / STANDARD COMPLIANCE L rM EC ICPa 1O 5aEt,ILCC1000671EC6111063 Safely II 01129 11I II>uRP.y 1,UL174=_ 7' poll$ is INSTALLATION SPECIFICATIONS Maximum AllowErd Systom VoltagEt 1.000 Vdr. DIM(wd I brackut NV x L x H Ylx25dx t0 / SS 0.08 i..50 mm/ r e 1 -,I excluding mounting twat FM RN LxH 141x212 ID / 5 834159 sir/ n W.Aht I d g Il : ntmoun rg bid'ke 1170/254 122/It] Input Cu nectar MCG/Arnp eo1/lyre Output t Double I4.A phenol / Output Wire Length 001)/10 n/ft �R e. Operating frRange 40 r85/40-1-185 Pr-OFR[1.1On Rating I26 4 p. enc M 0 100 Humidity n.e.ry ..,...n.no..,r 0 100 a.. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER SINGLE PHASE THREE PHASE THREE PHASE 208V 480V Minimum String lenelh IPowro Optmversl 8 10 18 Compatible with Zep Groove framed modules Maximum String Iength)Power oprrr.i,urs) 15 25 50 Mavhnum Power per siring 1050 6000 11/40 w - Certified Zep Compatibles bracket - Mitigates all types of module mismatch losses from Parallel Strings of Differ Lengths or Orientations Yes — Attaches to module frame without screws-reduces onroof manufacturing tolerance to partial shading labor and mounting Costs — Flexible system design for maximum space utilization — Power optimizer equipment grounded through the bracket — Next generation maintenance with module-level monitoring — Up to 25%more energy — Module-level voltage shutdown for installer and firefighter - Superior efficiency(99.5%) safety CE (10 . .r ,r ,r.e:fid, tat