573 Septic Inspection 2016 Commonwealth of Massachusetts
Title 5 Official Inspection Form
a�l Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
Owner
information is
required for
every page.
Important:
When filling out
forms on the
computer,use
only the tab key
to move your
cursor-do not
use the return
key.
C
tSins•09/08
573 Westhampton Rd. Florence Ma. 01062
Property Address
James& Cynthia Faulkner
Owner's Name
same
City/Town
Ma 01062 05/18/16
State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
A. General Information
1. Inspector:
Ray Champagne
Name of Inspector
Whiteley Septic Service
Company Name
21 Old County Rd.
Company Address
Southampton
City/Town
413-527-0057
Telephone Number
Ma.
State
514118
License Number
Ma.
Zip Code
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5(310 CMR 15.000).The system:
Z Passes
❑ Conditionally Passes ❑ Fails
] Needs Further Evaluation by the Local Approving Authority
nspector's Sig tore
05/18/16
Date
The system inspector shall submit a copy of this inspection report to the Approving Authority (Board
of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or
has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the
report to the appropriate regional office of the DEP.The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time. This inspection does not address how the system will perform in the future under
the same or different conditions of use.
Tine 5 official Inspection Form.Subsunace Sewage Disposal System•Page 1 of 17
Owner
information is
required for
every page.
rsne.09/08
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
Property Address
James &Cynthia Faulkner
Owner's Name
same Ma 01062 05/16/16
Clly/Town State Zip Code Date of Inspection
B. Certification (cont.)
inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
This system consists of a 1500 gal 2 compartment septic tank with p astic tee baffles and a filter in
outlet baffle. A d box leads into a 4 leg infiltrator field and besides heavy carry over in d box all levels
are correct and no high water marks were observed.
B) System Conditionally Passes:
] One or more system components as described in the"Conditional Pass" section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health,will pass.
Check the box for"yes", "no"or not determined" (Y, N, ND) for the following statements. If not
determined," please explain.
The septic tank is metal and over 20 years old*or the septic tank (whether metal or not) is
structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System
will pass inspection if the existing tank is replaced with a complying septic tank as approved by the
Board of Health.
A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
Tie 5 official Inspeo on Form:Subsurface Sewage Disposal S)5Rn•Page 2 of 17
Owner
information is
required for
every page.
Sins'09/08
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
Property Address
James& Cynthia Faulkner
Owner's Name
same Ma 01062 05/18/16
City/Town State Zip Code Date of Inspection
B. Certification (cont.)
13) System Conditionally Passes (cont.):
Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed O Y D N E ND (Explain below):
C)
Further Evaluation is Required by the Board of Health:
Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health,safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
Title s Official Inspection Form Sutsuaace Swage Disposal System•Page 3 of 17
)wner
)formation is
squired for
very page.
t5tns•09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
Property Address
James&Cynthia Faulkner
Owner's Name
same Ma 01062 05/18/16
City/Town State Zip Code Date of Inspection
B. Certification (cont.)
2. System will fail unless the Board of Health(and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well'".
Method used to determine distance:
' This system passes if the well water analysis, perforated at a DEP certified laboratory,for coliform
bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or
'j.ess than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be
attached to this form.
3. Other
D) System Failure Criteria Applicable to All Systems:
You must indicate "Yes"or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than %day flow
Title 5()Metal nspeceoo Form:Subsurface Sewage DRpoeaI Syst ff•Page 4 of 17
)wrier
'formation is
equired for
very page.
thins•09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
Property Address
James& Cynthia Faulkner
Owner's Name
same Ma 01062 05/18/16
City/ own State Zip Code Date of Inspection
B. Certification (cant.)
Yes No
❑ Z Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ Z Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ Z Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ Z Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ Z Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ Z Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal conform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
❑ ❑ The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
❑ Z The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303,therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes" or"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area— IWPA)or a mapped Zone II of a public water supply well
If you have answered "yes"to any question in Section E the system is considered a significant threat,
or answered "yes" in Section D above the large system has failed. The owner or operator of any large
system considered a significant threat under Section E or failed under Section D shall upgrade the
system in accordance with 310 CMR 15.304. The system owner should contact the appropriate
regional office of the Department.
Title 5 Official Inspecton Form:Subsurface Sewage Disposal Systerc•Page 5 of 17
L\ Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
Property Address
James& Cynthia Faulkner
Owner's Name
same Ma 01062 05/18/16
City/Town State Zip Code Date of Inspection
wrier
formation is
quired for
'ery page.
15:ns•09108
C. Checklist
Check if the following have been done. You must indicate "yes" or"no" as to each of the following:
Yes No
® ❑
® ❑
® ❑
® ❑
® ❑
® ❑
® ❑
® ❑
® ❑
Pumping information was provided by the owner, occupant, or Board of Health
Were any of the system components pumped out in the previous two weeks?
Has the system received normal flows in the previous two week period'
Have large volumes of water been introduced to the system recently or as part of
this inspection?
Were as built plans of the system obtained and examined? (If they were not
available note as N/A)
Was the facility or dwelling inspected for signs of sewage back up?
Was the site inspected for signs of break out?
Were all system components, excluding the SAS, located on site?
Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid,depth of sludge and depth of scum?
Was the facility owner (arid occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS)on the site has
been determined based on:
Existing information. For example, a plan at the Board of Health.
Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable) [310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
3 — Number of bedrooms (actual):
Number of bedrooms (design): _ —
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms):
3
330
Tito 501flciel lnspeaon Form:Subsurface Sewage Drsposal Syswr.Page 6 N 17
vner
ormation is
tuired for
ery page.
rsns•09/08
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
Property Address
James &Cynthia Faulkner
Owner's Name
same Ma 01062 05/18/16
City/Town State Zip Code Date of Inspection
D. System Information
Description:
2
Number of current residents:
Does residence have a garbage grinder? ® Yes ❑ No
Is laundry on a separate sewage system? if yes separate inspection required] ❑
Yes ® No
Laundry system inspected? ❑ Yes ❑ No
Seasonal use? ❑ Yes ® No
cif wager 1657
Water meter readings, if available (last 2 years usage (gpd)):
Detail:
water meter reading 1857 - - -
Sump pump?
Last date of occupancy:
Commercial/Industrial Flow Conditions:
Type of Establishment:
Design flow (based on 310 CMR 15.203):
Basis of design flow(seats/persons/sq.ft., etc.):
Grease trap present?
industrial waste holding tank present?
Non-sanitary waste discharged to the Title 5 system?
Water meter readings, if available:
Gallons per day(gpd)
❑ Yes ® No
resently__
Date
❑ Yes ❑ No
❑ Yes ❑ No
❑ Yes ❑ No
Title s Official Inspection Form:suosudace Sewage Disposal System.Page 7 of 17
at
'motion is
sired for
y page.
Sins•09/08
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampon Rd. Ma. 01062_Property Address
James &Cynthia Faulkner
Owner's Name
same Ma 01062 05/18/16_
Citym'own State Zip Code Date of Inspection
D. System Information (cont.)
Last date of occupancy/use:
Other(describe below):
General Information
Pumping Records:
Source of information:
Was system pumped as part of the inspection?
If yes, volume pumped.
Iiow was quantity pumped determined?
Reason for pumping:
Type of System:
® Septic tank,distribution box, soil absorption system
2012 owner
gallons
presently_
Date
❑ Yes ® No
Single cesspool
Overflow cesspool
Privy
Shared system (yes or no) Of yes, attach previous inspection records, if any)
Innovative/Alternative technology. Attach a copy of the current operation and
maintenance contract(to be obtained from system owner) and a copy of latest
inspection of the I/A system by system operator under contract
0 Tight tank.Attach a copy of the DEP approval.
Other(describe):
tine 5 Official Inspection Forn Subsurface Sewage Disposal System•Page a of n
Commonwealth of Massachusetts
R Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 WesthamEton Rd. Florence Ma 01062 _— _- --.—_—.—— --
Property Address
James& Cynthia Faulkner_ ---_.-_ --- --
Owner's Name
A _ 01062 _—. 05/18/16
_—.—
Came --' Stata e Zip Code Date of Inspection
D. System Information (cont.)
Approximate age of all components, date installed (if known) and source of information.
5 yrs estimate —_—.--- --- -
Were sewage odors detected when arriving al the site?
Building Sewer(locate on site plan):
Depth below grade:
Material of construction:
❑ cast iron D
40 PVC ❑ other(explain):
Distance from private water supply well or suction line.
nation is
red for
I Page
151ns•0903
2.5
feet
feet
Comments (on condition of joints, venting, evidence of leakage, etc.):
No evidence of leakage observed,_ —.--_._.. —.----- --
Septic Tank(locate on site plan):
Depth below grade:
Material of construction:
El concrete metal ❑ fiberglass ❑ polyethylene ❑ other (explain)
❑
24"
feet
❑ Yes ® No
4 tank is metal, list age'.
is age confirmed by a Certificate of Compliance? (attach a copy of certificate)
1500
years
Dimensions:
Sludge depth:
3
❑ Yes ❑ No
Title 5 Official Inspecnon Form subsurface Sewage Disposal Syste r'Page 9 of 17
Z. Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
ct-di 573 Westhampton Rd. Florence MaOt Property Address
James 8 Cynthia Faulkner —.— ----- --- — -- —
r owner's Name k112 01062 05/16/16
tattoo is same Ma — — -
ed for ---— ---- — — — State Zip Code Date of Inspection
page. City/Town
D. system Information (cont.)
Septic Tank(cont.)
Distance from top of sludge to bottom of outlet tee or baffle
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
tape
How were dimensions determined? -
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Pumping recommendation of every 2 years depending on use and removal of garbage grinder„ also
to clean filter annually
32
3"
10"
Grease Trap (locate on site plan):
Depth below grade:
Material of construction.
❑ concrete [1 metal
feet
❑fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping:
15ins•09108
Otte
Ti e 5 INricxI mspec0oo Foam Subsurface Sege Disposal Sysem Page 10 at 17
:r
nation is
red for
page.
t5ins•09/00
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd_Florence Ma. 01 ----
Property Address
James&Cynthia Fae ner
Owner'sName Ma 01062 05118116_
Same ------- --- - --- - State Zip Code Date of Inspection
Cttyl1"own
D. System Information (cont.)
Comments (on pumping recommendations, inlet and outlet tee or bole condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
all Nits appear to be sound and levels are correct,fairly heaves carryover observed In d bor:_
Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑ concrete [1 metal ❑
fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Capacity: gallons
Design Flow: gallons per day
Alarm present: ❑ Yes ❑ No
—.. -- Alarm in working order. ❑ Yes ❑ No
Alarm level: -- —
Date of last pumping: bale —
Comments (condition cf alarm and float switches, etc.):
Attach copy of current pumping contract(required). Is copy
attached? ❑ Yes ❑ No
me 5 Official Inspecbon For S surface Sewage Disposal System Page 11 of 17
ation is
ed for
Page.
t5ins•03100
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhameton Rd. Florence Ma. 01062_ --. _ ---- --- -
—
Property Address
James & Cynthia Faulkner— — ----------------
Owner's Name
same
_ Ma 01062 —.—
--. _ -- --
_—'----- State Zip Code Date of Inspection
City/town
D. system Information (cont.)
Distribution Box(if present must be opened) (locate on site plan):
0
Depth of liquid level above outlet invert
Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
solids carry over noticed but level correct
— —
Pump Chamber(locate on site plan):
❑ Yes ❑ No
Pumps in working order'.
Yes ❑ No
Alarms in working order.
Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.):
Soil Absorption System (SAS) (locate on site plan, excavation not required):
•'f SAS not located, explain why:
Title 5 Off icia1 Inspection Form.Subsu,lace Sewage Disposal System Page 12 or 17
L\ Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062 .__.----- ---
Properly Address
James &C iaFaulkner
ed for - -- ---.. -------- --
— —
r ownrr's Name r)_nt Ma 01062 05/18/16
canon is
same --- ----- - Mate Zip Code Date of Inspection
page City/Town
D. System Information (cont.)
'Type:
❑ leaching pits number:
❑ leaching chambers number:
❑ leaching galleries number:
❑ leaching trenches number, length:
❑ leachincl fields number, dimensions:
overflow cesspool number:
❑ innovative/alternative system
Type/name of technology:
Comments (note condition of soil, signs of hydraulic failure, level of bonding,damp soil, condition of
vegetation, etc.):
No sins of Ilydraulic failure observed
tSins-09/08
4 legs 13x24 field
Cesspools(cesspool must be pumped as part of inspection) (locate on site plan):
(Number and configuration
Depth-top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
❑ Yes ❑ No
indication of groundwater inflow
Title 5 Official Inspection Form:Subsurface S w ge Dsposal System'Page 13 M 17
L. Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 WeslhampionRd. Florence Ma. 01062
Property Address
James&Cynthia Faul ner_ —_--.—.—.— —---
owner's Name
same Ma 01062 06/18!16
_ _ _.—_--
--- -- --
City/town State Zip Code Date of Inspection
D. 'System Information (cont.)
Comments (note condition of soil, signs of hydraulic failure, level of pending, condition of vegetation,
etc.):
sand soil atd box _ — --.-- --------
canon is
ed for
page.
thins 09108
Privy (locate on site plan):
Materials of construction.
Dimensions
Depth of solids
Comments (note condition of soil, signs of hydraulic failure, level of pending, condition of vegetation,
etc.):
Ties Official LnspactOn Form Subsurface Sewage Deposal System'Page 14 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westham�n Rd. Florence Ma. 01062
Property Address
James& Synthia Faulkner
Owner's Name
same
CityiTown
D. System Information (cant.)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system. including ties to
at least two permanent reference nce the landmarks
Irks or
Check one benchmarks.
tLo boxes all below within 100 feet. Locate
where public water supply Be
E hand-sketch in the area below
❑ drawing attached separately
•
ation is
ad for
page.
Ma 01062 05/18/16
Stele Zip Code Date of Inspection
Tte e OM:a,':ospxt=7mm S.CS✓IZC sswea Dspuat ssreo•Pose a of 7
ler
malion is
sired for
y page.
b,ns•09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
Property Address
James &Cynthia Faulkner
Owner's Name Ma 01062 05/18/16
same
City/Town State Zip Code Date of Inspection
D. System Information (cont.)
Site Exam:
121 Check Slope
IEI Surface water
Check cellar
Shallow wells
Estimated depth to high ground water:
5-6ft+ estimate
feet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed:
Date
Observed site (abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health-explain:
❑ Checked with local excavators, installers- (attach documentation)
❑ Accessed USGS database - explain:
You must describe how you established the high ground water elevation:
sandysoil at leach area no sump pump
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
tee 5 Oltival Inspection Form:Subsurface Sewage Disposal System Page 16 0117
Commonwealth of Massachusetts
9 Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
573 Westhampton Rd. Florence Ma. 01062
mer
,rmation is
luired for
ary page.
nms•OS/00
Property Address
James& Cynthia Faulkner
Owner's Name
same Ma 01062 05/18/16
City/Town State Zip Code Date of Inspection
E. Report Completeness Checklist
Z Inspection Summary:A, B, C, D, or E checked
H Inspection Summary D (System Failure Criteria Applicable to All Systems) completed
Z System Information—Estimated depth to high groundwater
21 Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file
Titles Olrival Inspection Form Subsurface Sewage Disposal SKtm,Page 17 of 17