23A-291 (10) 190 NONOT[ICK ST-NTON VET CLINIC BP-2017-0173 GIS#; COMMONWEALTH OF MASSACHUSETTS Mao-Block: 23A-291 CITY OF NORTHAMPTON Lot:-60_0 Permit: Building BUILDING PERMIT Care ryB :renovation UILDING 1 RMI T Permit y BP-2017-0173 Project# JS-2017-000284 Est.Cost:$219000.00 Fee: $1533.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: lyse Group MARK SARAFIN 053434 Lot Size(sq.ft.i Owner: NORTHAMPTON VETERINARY CLINIC REAL ESTATE TRUST LLC Zoning:G1(100)/ Applicant: MARK SARAFIN AT: 190 NONOTUCK ST - N'TON VET CLINIC Applicant Address: Phone: Insurance: 42 Pomeroy Meadow Road (413) 527-7812 Workers Compensation SOUTHAMPTONMA01073 ISSUED ON:8/29/2016 0:00:00 TO PERFORM THE FOLLOWING WORK: REMODEL & RECONFIGURE SPACE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeTYpe: Date Paid: Amount: Building 8129.,20160:00:00 51533.00 212 Main Street, Phone(413)587-1240 Fax: (413)587-1272 Louis Hasbrouck-Building Commissioner File(1 BP-2017-0173 APPLICANT/CONTACT PERSON MARK SARAFIN ADDRESS/PHONE 42 Pomeroy Meadow Road SOUTHAMPTON01073 (413)5'27-7812 PROPERTY LOCATION 190 NONOTUCK ST-N'TON VET CLINIC MAP 23A PARCEL 291 000 ZONE GI(100V THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT �/y ��/� Fee Paid /O�f&g Sr3J, 33 Buildinp Permit Filled out Fge Paid TvpeofConstructionJIEMODEL&.RECONFIGURE SPACE New Constructipn Non Structural interior renovations Addition to Existing _ Accessory Structure Building Plans Included: Owner/Statement or License 053- 434 C _F.--, Q 3 sets of Plans/Plot Plan 1c G leamiC Y Aid THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFO ATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: §_ Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management ! molition De sy ,tom' /( Signature of Bui .im'T"tial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. Variances are granted only to those applicants who meet the strict standards of MGL.40A. Contact Office of Planning&Development for more intormation. Versfon1 7 Commercial Boldin_Permit May 15,2000 Department use only RF City of Northampton Status of Permit C�• .co Mg Department Curb Cut:Driveway Permit AUG . 2 Main Street Sewer/Septic Availabiltty " s 9 'lQj Room 100 Water/Well Availability o ampton, MA 01060 Two Sets of Structural Plans Ar oF.at Ar 'unrraG. • one '13 .87-1240 Fax 413-587-1272 Plot/Site Plans a*un tone Other Specify APPLICATION TO CONSTRR1,REPAIR,RENOVATE,CHANGE THE USE OR OCCUPANCY OF,OR DEMOLISH ANY BUILDING OTHER THAN A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1 1.1 Pro a��ddress,'1y'{1+ 1 This section to be completed by office f `I ock 5�-K1 r2 .. Map Lot Unit 'reyiIIP1( Q 1 'G' 0\CAD-V Zone Overlay District -- - -- -- - Elm St District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 3.1 ner of Record: j`[ o2 law p/Eon Ve C�ks IC PEA cJin L---1 Q� fl d+ Name(Print) (ICM1t/ 5W thhy Current Mailing Address >r 1. Signature .i.701 Telephone 2.2 Authorized Agent: INVA4L 12,/y6,,,4(24Fi 98 -am.7<,.f bnye,S., 2crcP , Name{Pdnt} � �-(V4 tweet04 Atltlress ` Signature r Telephone 44 R- ca 4_ -3_911 - "3-911 a SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant I. Buildinghet, (a) Building Permit Fee no 0 2. Electrical '2 - . ! (b}Estimated Total Cost of 6O b0�.'1. Construction from(6) 3, Plumbing ,„»)O T DaG .moi Building Permit Fee 5. Total rotectt {HVA£) Q 4 Mechanical + '/�7 //f}/---(�� Protection * t � _ _ . !� • 2+3+4+5) a 00 , GQ Check Numbel'� jV— s../ ,/JI` his Section For Official Use Only Building Permit Number Date Issued Signature: I Building Commissioner/Inspector of Buildings Date Versionl.7 Conuncrcial Building Permit May 15, 2000 SECTION 4-CONSTRUCTION SERVICES FOR PROJECTS LESS THAN 35,000 CUBIC FEET OF ENCLOSED SPACE Interior Alterations g Existing Wall Signs 0 Demolition^ Repairs 0 Additions 0 Accessory Building Exterior Alteration 0 Existing Ground Sign 0 New Signs 0 Roofing❑ Change of Use Other (1 Brief Description Enter' a brief description here. 2eµtp�_', e, m4 ` 5 'CC Qe-('o.,}19,,.Q,p Of Proposed Work: Leto '-I�rA.1 Q6670 Ot _:5QuCEU� . SECTION 5-USE GROUP AND CONSTRUCTION TYPE USE GROUP(Check as applicable) CONSTRUCTION TYPE A Assembly ❑ A-1 0 A-2 0 A-3 0 1A ❑ A-4 0 A-5 0 1B ❑ B Business 2A 0 E Educational ❑ 2B 0 F Factory ❑ F-1 ❑ F-2 ❑ 2C ❑ H High Hazard 0 3A j ❑ I Institutional 0 I-1 0 I-2 ❑ 1-3 ❑ 3B M Mercantile 0 4 0 R Residential 0 R-1 0 R-2 0 R-3 0 5A 0 S Storage 0 5-1 0 S-2 0 5B ❑ U Utility ❑ Specify: M Mixed Use 0 Specify -.... _ S Special Use ❑ Specify. - - COMPLETE THIS SECTION IF EXISTING BUILDING UNDERGOING RENOVATIONS,ADDITIONS AND/OR CHANGE IN USE Existing Use Group: _ _: Proposed Use Group: Existing Hazard Index 780 CMR 34): Proposed Hazard Index 780 CMR 34): • SECTION 6 BUILDING HEIGHT AND AREA BUILDING AREA EXISTING PROPOSED NEW CONSTRUCTION OFFICE USE ONLY Floor Area per Floor(sf) 111 92)4-101st . ... _ 2n° 3° 3m _._- .. .._ .. .. . . CN .... _ 41h Total Area(sf) Total Proposed New Construction(sf) Total Height(ft) Total Height ft _.. __... 7.Water Supply(M.G.L.c.40,§54) 7.1 Flood Zone Information: 7.3 Sewage Disposal System: Public lla' Prorate El Zone Outside Flood Zone Municipal On site disposal system Version!.?Commercial Building Permit May 15,7000 8. NORTHAMPTON ZONING Existing Proposed Required by Zoning This column to be filled in by Building Depzmnen( Lot Size Frontage Setbacks Front Side L R _ L R Rear Building Height Bldg Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO Q DONT KNOW in YES Q IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DON'T KNOW Q YES Q IF YES: enter Book Page and/or Document 8 B. Does the site contain a brook, body of water or wettands? NO Q DONT KNOW A YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Q , Date Issued: C. Do any signs exist on the property? YES Q NO Q IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES V NO Q tF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan Mat will disturb overt acre? YES Q NO vr4 IF YES,then a Northampton Storm Water Management Permit from the DPW is required. Va.sion1.7 Commercial Sutldtng Penna May 5,2000 SECTION 9-PROFESSIONAL DESIGN AND CONSTRUCTION SERVICES-FOR BUILDINGS AND STRUCTURES SUBJECT TO CONSTRUCTION CONTROL PURSUANT TO 760 CMR 116(CONTAINING MORE THAN 38,000 C.F.OF ENCLOSED SPACE) 9.11 Registered Architect: _ Not Applicable 0 Name(Registrant) /VIA, 8�3 55- Cretan Number/G!(7�JNG^1 /FW\ n RegisCe 13l201 1D/address .. Expiration Date Signature Telephone 9.2 Registered Professional Engineer(s): Name Area of Responsiblity Address Registration Number -.n.. Signature Telephone Expiration Gate Name Area of Responsibility Address Registration Number Signature Telephone Expiration Date Name Area of Responsibility Address Reg station Number Signature Telephone Expiration Date Name Area of ResponsibiIity Address _ _.. Regslrafion Number .. .. Signature Telephone Expiration 0ata 9.3{G'eneral Contractor y 0-47, 4 (�Fly WC. tn'S Not Applicable 0 ..— Company Name: Re�sJponSbie InnCharge of Construct= i, { -{a Pim w Y11�ah.., s iNG\+'�Q '\O '1 vv‘ Address f \ The> 4(3-la ?-191, { (3 sa ?-191- ' Signature Telephone • Version1.7 Commercial Building Permit May IS,2000 1 SECTION 10-STRUCTURAL PEER REVIEW(780 CMR 110.11) Independent Structural Engineering Structural Peer Review Required Yes 0 No 0 SECTION 11 -OWNER AUTHORIZATION-TO BE COMPLETED WHEN ------_ OWNERS`AGENTA .. OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, C.Sy,_uiiPt,�tn�yu.l tt(K ( ,as Owner of the subject property hereby authorize Mark- Sat€46 vl :.....� _.. . to - 51 t o ore Ohalff, n ail matters relative to work authorized bythis beading permit application 9pp 0 �..._..... _...... Date Y'Vsc q V 51.442 wait':a.by _ _ ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed nunder the pains and penalties of perjury._ 1/4 Print Name , p _. Signature of Owner/Agent Dam SECTION 12-CONSTRUCTION SERVICES 10.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Heider V‘AsAksit. ._ yWfGviF 4S— Oc3'-13' •• 111 ii�� NAA V(i (\�� {' y1,1t� ,{� License�N(umberO i'*'inEq � `-OC& c�CZACibt ✓1, rima. '1^a 2,— 01-4— ..._ Address CA -9-? Expiration Date 1.i_ � `o3-5-a 4 .3973 Signature Telephone SECTION 13-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M,G,L.c. 162,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes at, No 0 The Commonwealth ofAfassachusetts i —_.....=: Department of Industrial Accidents -� - Office of Investigations '., 600 Washington Sheet Boston,MA 02.111 wn'w.mass.gov/dia Workers' Compensation Insurance_Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information ',� ,t Please Print Legibly Name (Business/O+ganizat�i000ivindividual): yy\W✓a,(}k �/v}hy.`�v{t.�)n _ Address: c'r IX i a.ti.-�,i� l eow(yo�.,.,, `corn C..% _ City/State/Zip: 5` VVis O',a' Phone#: '-1 ti-Ai d - i3 ti Are you an employer? Check the appropriate box: Type of project(required): 1.( jarn a employer with oa _ q. 0 I am a general contractor and 1 — employees(full and/or part-time).* have Aired the sub-contractors6. _ New construction 2.0 t am a sole proprietor or partner- listed on the attached sheet, 7. 0 Remodeling ship and have no employees These sub-contractors have 8. U Demolition workin for me in any capacity. employees and have workers' g P e = 9. 0 Building addition [No workers' comp.insurance comp. insuran.;e. required.] 5. 0 We are a corporation and its 10.0 Electrical repairs or additions '] I am a homeowner doing all work officers have exercised their I I.J Plumbing repairs or additions • myself. o workers' right of exemption per MCL [N comp. 12.0 Roof repairs insurance required.]r c. I52,§/(4),and we have no employees. rNo workers' 13.�,Other Tv) eKe4 leA + to^S comp. insurance required.] "Any applicant that checks box 51 must also fill out the section below showing their workers'compensation policy information. Homeowners who submit this affidavit indicating they are doing all work and than hire outside contractors must submita new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contactors and state whether or not those entities have employees. If the sb-contactors have employees,they must provide their workers'camp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. /� Insurance Company Name: f- -t W\ (I✓� vcq,,, � _ „_ Policy.or Self-ins.Lie.#: t) ts1C - ((')�} - (,p0"Aq Expiration Date: LO- lob Site Address: t-{O 'imp LtL 5.4 ere Q,}.- City/State/Zip: , lWL' nrnl7kin ✓ ..- Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A ofMGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the farm of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage ver' nation I do here( t cent e• hep a_',f�Jenaltie that the information provided abate is true and correct Sj rature: 2_/ -<t .Date'_.. g 8- aot (O Phone N: LI/3 -' 1r� /=T$i Official use only. Do not trite in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone b: City of Northampton 212 Main Street, Northampton, NLA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, 554, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: t(10 ✓\ono \.,c \c, 5a . - -t \- The debris will be transported by: -t The debris will be received by: Ucct&t QrNcl, r ` Building permit number: Name of Permit Applicant OA k 5 uv4Fi-i Date Signature of Permit Applicant Initial Construction Control Document Tg rY To be submitted with the building permit application by a _ j Registered Design Professional for work per the 8t11 edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Renovations for Northampton Veterinary Clinic Date: 29 July,2016 Property Address: 190 Nonotuck Street,Florence,MA 01062 Project: Check(x)one or both as applicable: New construction X Existing Construction Project description: Demolition in preparation for limited interior renovations I Richard E.Katsanos MA Registration Number:8355 Expiration date:08/31/2016 ,am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning`: Arch iteetura I Structural Mechanical Fire Protection Electrical X Other: demolition for the above named project and that to the best of my knowledge,information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: I. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties fur registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit fietdtprogress reports(see item 3.)together with pertinent comments, in a form acceptable to.the building official. Upon completion of the work, I shalt submit to the building official a'Final Construction Control Docume��.ni, Enter m the space to the right a"wet"or 5` ,p.T`r'A4'0 electronic signature and seal: jj. ><:• in ygs5`S � H rtr , P i 3 4 4 Phone number: 413-585-1512 Email: Richard,Katsanos@liAlArehitecdure,com 4104AR Illll/ 4Rrtht WI f TS Building Official Use Onh r Building Official Name: Permit No.: Date Note I.indicate with an•x'project design plans.computations and specifications that you prepared or directly'tapas:ised.II'other Is chosen. provide a description. Version 06_11. 2013 Existing Conditions Evaluation Report Massachusetts Building Code 780 CMR 8th Edition International Existing Building Code 2009 Renovations for Northampton Veterinary Clinic 190 Nonotuck Street Florence, Massachusetts 01062 July 29, 2016 ,max ,5AN03 %6 ,0' ¢,rf✓rr-krriV+11, ; As prepared by Richard E. Katsanos, AIA, Principal HI Al Architecture ,4(w tl cxn,:c.'lir A Ummp6m. tllapxa II; ,-I'+i_ t R i .'.,;; _t i.iahv. tir _om Massachusetts Building Code 780 CMR 8th Edition International Existing Building Code 2009 Renovations for Northampton Veterinary Clinic 190 Nonotuck Street Florence, Massachusetts 01062 Purpose This Report is in conformance with Massachusetts Building Code 780 CMR 8th Edition and the International Existing Building Code 2009 regarding alterations to an existing building located at 190 Nonotuck Street, Florence, Massachusetts. Visual Observation Only The extent of this review is limited to visual inspection of existing facilities and/or as-built documentation only, No destructive testing was performed as part of this analysis. Project Description The project consists of an interior renovation of approximately 4,296 square feet of existing interior space. The majority of existing spaces shall remain with finishes upgrades. Approximately 25% of the floor space shall be reconfigured with a new layout. Grade level access is provided via the main entrance doors and vestibule. Two additional means of egress serve the suite, one leading directly to the exterior and one leading to an existing common egress access corridor shared with other tenant spaces. All new work within the suite shall be accessible in compliance with AAB, „u,,111 .tleCt,'+111tt' \o§rtiokiiipton. vivrono !r. .1H? to a c ,- ..t.co,dar,d :\ ktun GENERAL EXISTING PROPERTY INFORMATION A. PROPERTY NAME: Florence Medical Center B. ADDRESS: 190 Nonotuck Street, Florence, Massachusetts 01062 C. BUILDING USE: The building was originally constructed as, and is currently used for B (Business) occupancy. D. BUILDING USE GROUP: B- Business (Business) as defined by the Massachusetts Building Code, 780 CMR 8"h Edition. E. CONSTRUCTION CLASSIFICATION: Type 3B Foundation: concrete slab on grade Exterior Walls: split face CMU masonry Int, Load Bearing: CMU Roof: flat membrane roofing on steel framing and deck F. HAZARD INDEX: Existing and proposed Hazard Index is 4 as defined by the Massachusetts Building Code, 780 CMR, 8th Edition (IEBC Table 912.4) �. otlu 4 ,rl.5,I,t, 1.1 „ptnt4V 9r„n d1= . .�❑ td..❑ .,S,y. { ,a- h: ,,_ .,.,., CLASSIFICATION OF WORK The proposed project work area is classified as Alteration - Level 2 per IEBC Section 404 and therefore complies with the provisions of Chapter 6 and Chapter 7 for the following reasons: - The project is not a repair, therefore IEBC Section 402 does not apply - The project exceeds the limitations defined under Level 1 Alterations as specified in IEBC Section 403: Level 1 alterations include the removal and replacement or the covering of existing materials, elements, equipment, or fixtures using new materials, elements, equipment, or fixtures that solve the same purpose. - The project meets the limitations defined under Level 2 Alterations as specified in IEBC Section 404: Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment. - The project is below the threshold triggering Level 3 Alterations as specified in IEBC Section 404: Level 3 alterations apply where the work area exceeds 50 percent of the aggregate area of the building. - The project does not involve a change of occupancy, therefore IEBC Section 406 does not apply. - The project does not involve an addition, therefore IEBC Section 407 does not apply. - The project does not impact the exterior or substantial interior configuration of a historic building, therefore IEBC Section 408 does not apply. - The project does not involve a relocated building, therefore IEBC Section 409 does not apply. ,Ir. Suite I. A 1cn�,L.:.. AIAwool) AI}. r:_ fid, lI „'^A': .,,LLrr.kit,4c.,,,-u ALTERATIONS LEVEL 2 Section 701 General This project work area will comply with all requirements for Alteration Level 1 as specified in Chapter 6 and all requirements of Level 2 as specified in Chapter 7. No portion of the proposed project work area alters the existing conditions such that the building will become less safe than its existing condition. Requirements regarding flood hazard areas are not applicable to this project Section 702 Special Use and Occupancy Not applicable. Section 703 Building Elements and Materials 703.2 Vertical Openings No new or existing vertical floor openings are within the project work area. 703.3 Smoke barriers This section applies to I-2 occupancies and therefore does not apply to this project. 703.4 Interior finishes All new interior finishes, including wall, ceiling, floor, and trim materials to be installed under this project work area will comply with Massachusetts Building Code 780 CMR 8th Edition. 703.5 Guards The existing rear exit is not code compliant in that there is a step down at the threshold and the exterior landing and steps are not dimensionally correct, nor is there a railing or guard. This will be corrected under this project. Section 704 Fire Protection 704.2 Automatic sprinkler systems „t i.qrric 5,,,t,I,v.r1< „}«.,,.'Il 4o- ;=r t,,,,ti , t�r_,r. nta 704.3 Standpipes nta 704.4 Fire alarm and detection A fire alarm system (Notifier brand), consisting of horntstrobe units, smoke detectors and manual pull stations, compliant with the International Fire Code, exists within this suite Notification consists of horn and strobe devices. The project will modify this fire alarm system. Section 705 Means of Egress The existing and new egress requirements within the project work area are compliant with Massachusetts Building Code 780 CMR 8th Edition and NFPA Life Safety Code 101. 705.3 Number of Exits: Unchanged. Three exists serve the suite, 705.4.1 Egress doorways —two egress doorways required Unchanged. Three egress doors serve the suite—two direct exits to the exterior and on to an existing common egress access corridor serving multiple tenants. 705.4.2 Egress doorways -door swing Based on occupant load, the exit doors do not need to swing in the direction of travel. Existing doors at the main entrance and vestibule and the rear exit swing in the direction of travel, while the door leading to the common exit access corridor swing into the suite. 705.4.3 Egress doorways - door closing Existing doors at the main entrance and vestibule, the rear exit and the door leading to the common exit access corridor each have a door closer. 705.4.4 Panic hardware nta—calculated occupancy below 49 occupants nit.,[duvt.bnik I. North uiplm, \OHNO Ln 705.5 Openings in corridor walls Corridors in this occupancy are not required to be rated. 705.6 Dead end corridors There are no dead end corridors within the project work area. 705.7 means of egress lighting Egress lighting consists of battery pack emergency light units. Existing and new units shall be located as required by code. 705.8 Exit signs Existing compliant fixtures remain unchanged. Several new internally illuminated exit signs shall be installed as part of this project indicating egress. 705.9 Handrails Rear exit steps shall have code compliant handrails. 705.10 Guards Rear exit steps shall have code compliant guards. Section 706 Accessibility In accordance with Massachusetts Architectural Access Board 521 CMR, because the project construction cost exceeds $100,000.00 but is less than 30% of the replacement cost for the entire building, all new work within the project work area is required to conform to the requirements of Massachusetts Building Code 780 CMR 8th Edition Section 605 and 706 and Massachusetts Architectural Access Board 521 CMR. All newly built components of the project shall be in compliance with Massachusetts Building Code 780 CMR 8th Edition Section 605 and 706 Massachusetts Architectural Access Board 521 CMR. el Gotl, 9r,•o�Sua:1. . rf6x,pb ,.A IA(Sitio 1[I '.FI] tavif „-Kh t ..:hma n . ., Section 707 Structural The scope of this project work area does not affect any existing structural systems, nor does it affect applied loads on existing structural systems. Section 708 Electrical 708.1 New Installations Convenience outlet wiring, lighting, and data wiring are included in the project and shall comply with the requirements of the Massachusetts Electrical Code. 708.2 Existing Installations B-Business occupancy does not apply 708.3 Residential occupancies B-Business occupancy does not apply Section 709 Mechanical 709.1 Reconfigured or converted spaces Existing HVAC ductwork and diffusers shall be relocated and rebalanced at renovated areas to provide mechanical ventilation to all spaces within the project area. 709.2 Altered existing systems The existing and modified HVAC system shall provide at least the code minimum 5 CFM per occupant (215 CFM) of outside air and 15 CFM per occupant (645 CFM) of ventilation air. 709.3 Local exhaust A new anesthesia scavenging system serving the animal operating room shall be directly vented to the building exterior. suit.. vn ' t.o. Section 710 Plumbing 710.1 Minimum fixtures Because the occupant bad of the project work area story shall not be increased more than 20 percent, existing plumbing fixture quantities are not required to be modified. Section 711 Energy Conservation 711.1 Minimum requirements Level 2 Alterations to existing buildings or structures are permitted without requiring the entire building or structure to comply with the energy requirements of the international Energy Conservation Code or international Residential Code. Areas of major reconfiguration shall have a new code compliant thermal envelope constructed at the roof level, to replace the existing thermal insulation laying directly on the suspended acoustic ceiling system. This area shall be separated from other above ceiling areas where the thermal insulation lays directly on the suspended acoustic ceiling system and shall remain. END OF EXISTING CONDITIONS REVIEW REPORT =+4 Gwl _, rt,SuhrLA t.. n b.n, ti\ T : 4 IT 1 mt. i -{_ m, vm { Initial Construction Control Document I To be submitted with the building permit application by a s 1 111 Registered Design Professional • for work per the 8th edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Renovations for Northampton Veterinary Clinic Date: 18 August,2016 Property Address: 190 Nonotack Street,Florence,MA 01062 Project: Check(x)one or both as applicable: New construction X Existing Construction Project description: Limited interior renovations I Richard E. Katsanos MA Registration Number: 8355 Expiration date: 08/31/2017 . am a registered design professional, and 1 have prepared or directly supervised the preparation of all design plans,computations and specifications concerning': X Architectural Structural Mechanical Fire Protection Electrical Other: for the above named project and that to the best of my knowledge, information,and belief such plans,computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I(or my designee)shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: I. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents_ 2. Perform the duties for registered design professionals in 780 CMR Chapter 17,as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit field/progress reports (see item 3.)together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a 'Final Construction Control Document'. Enter in the space to the right a"wet"or aNtteci electronic signature and seal: oisrzan.,�a�®e nyaan„a Erc„:���� �o SPry o9 m Richard E. ON.cn=alann,d E.Xa„xnoe,o AtChtte(141!0.CU. aw y el�aim.,mxanano,� nin,mwa w ,vyo i'tl9 Katsanos o.,e,o,b.ne,a,,15.44.54-04'00' Phone number:413-585-1512 Email:Richard.Katsanos@HA[Architecture.com 3 �MMr tt. . Building Official Use Only Building Official Name: Permit No.: Date: Note 1.Indicate with an'x'project design plans,computations and specifications that you prepared or directly supervised_ If'other' is chosen, provide a description. Version 06_11_2013 Existing Conditions Evaluation Report Massachusetts Building Code 780 CMR 8th Edition International Existing Building Code 2009 Renovations for Northampton Veterinary Clinic 190 Nonotuck Street Florence, Massachusetts 01062 August 18, 2016 Q�NttEcr R 5 h rP 4Ay 1� �4 it Richard Katsa nos A,chlee wecrync 20 60a„rr , As prepared by Richard E. Katsanos, AtA, Principal H I Al Architecture nAt ti a-I.',mitt ! ANEI ttit \IV11 . 5.I I_ lav41 4 — _ rdr, tm..en.0 Massachusetts Building Code 780 CMR 8th Edition International Existing Building Code 2009 Renovations for Northampton Veterinary Clinic 190 Nonotuck Street Florence, Massachusetts 01062 Purpose This Report is in conformance with Massachusetts Building Code 780 CMR 8th Edition and the International Existing Building Code 2009 regarding alterations to an existing building located at 190 Nonotuck Street, Florence, Massachusetts. Visual Observation Only The extent of this review is limited to visual inspection of existing facilities and/or as-built documentation only. No destructive testing was performed as part of this analysis. Project Description The project consists of an interior renovation of approximately 4,296 square feet of existing interior space. The majority of existing spaces shall remain with finishes upgrades. Approximately 25% of the floor space shall be reconfigured with a new layout. Grade level access is provided via the main entrance doors and vestibule. Two additional means of egress serve the suite, one leading directly to the exterior and one leading to an existing common egress access corridor shared with other tenant spaces. All new work within the suite shall be accessible in compliance with AAB. „,‘„,t1„, i,+,„„„,, A rtl., pi ,n. Anii -a; ;;; . isr GENERAL EXISTING PROPERTY INFORMATION A. PROPERTY NAME: Florence Medical Center B. ADDRESS: 190 Nonotuck Street, Florence, Massachusetts 01062 C. BUILDING USE: The building was originally constructed as, and is currently used for B (Business) occupancy. D. BUILDING USE GROUP: B- Business (Business) as defined by the Massachusetts Building Code, 780 CMR 8th Edition. E. CONSTRUCTION CLASSIFICATION: Type 38 Foundation: concrete slab on grade Exterior Walls: split face CMU masonry Int. Load Bearing: CMU Roof: flat membrane roofing on steel framing and deck F. HAZARD INDEX: Existing and proposed Hazard Index is 4 as defined by the Massachusetts Building Code, 780 CMR, 8lh Edition (IEBC Table 912.4) „�nR .utSuliI. � 0.m,pe.eArAi IJiL,i, fir. i i' ti fi .�-�r 1u,r.hia, , .w, CLASSIFICATION OF WORK The proposed project work area is classified as Alteration - Level 2 per IEBC Section 404 and therefore complies with the provisions of Chapter 6 and Chapter 7 for the following reasons: - The project is not a repair, therefore IEBC Section 402 does not apply - The project exceeds the limitations defined under Level 1 Alterations as specified in IEBC Section 403: Level 1 alterations include the removal and replacement or the covering of existing materials, elements, equipment, or fixtures using new materials, elements, equipment, or fixtures that serve the same purpose. - The project meets the limitations defined under Level 2 Alterations as specified in IEBC Section 404: Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment. - The project is below the threshold triggering Level 3 Alterations as specified in IEBC Section 404: Level 3 alterations apply where the work area exceeds 50 percent of the aggregate area of the building. - The project does not involve a change of occupancy, therefore IEBC Section 406 does not apply. - The project does not involve an addition, therefore IEBC Section 407 does not apply. - The project does not impact the exterior or substantial interior configuration of a historic building, therefore IEBC Section 408 does not apply. - The project does not involve a relocated building, therefore IEBC Section 409 does not apply. ei; I AoYh, �I n, A \1/10,11 113 _r,l'_ 1,1‘ U lv laa.h LLxlun s.mt ALTERATIONS LEVEL 2 Section 701 General This project work area will comply with all requirements for Alteration Level 1 as specified in Chapter 6 and all requirements of Level 2 as specified in Chapter 7. No portion of the proposed project work area alters the existing conditions such that the building will become less safe than its existing condition. Requirements regarding flood hazard areas are not applicable to this project Section 702 Special Use and Occupancy Not applicable. Section 703 Building Elements and Materials 703.2 Vertical Openings No new or existing vertical floor openings are within the project work area. 703.3 Smoke barriers This section applies to 1-2 occupancies and therefore does not apply to this project. 703.4 Interior finishes All new interior finishes, including wall, ceiling, floor, and trim materials to be installed under this project work area will comply with Massachusetts Building Code 780 CMR Sth Edition. 703.5 Guards The existing rear exit is not code compliant in that there is a step down at the threshold and the exterior landing and steps are not dimensionally correct, nor is there a railing or guard. This will be corrected under this project. Section 704 Fire Protection 704.2 Automatic sprinkler systems 1.4i44114.S .rtHtilt I, Nurthinlpion.VA 0114,0 I 41i... 14‘ 7Th r, ,.‘% hi. i,ii. tt:N Nun n/a 704.3 Standpipes n/a 704.4 Fire alarm and detection A fire alarm system (Notifier brand), consisting of horn/strobe units, smoke detectors and manual pull stations, compliant with the International Fire Code, exists within this suite Notification consists of horn and strobe devices. The project will modify this fire alarm system. Section 705 Means of Egress The existing and new egress requirements within the project work area are compliant with Massachusetts Building Code 780 CMR 8th Edition and NFPA Life Safety Code 101. 705.3 Number of Exits: Unchanged. Three exists serve the suite. 705.4.1 Egress doorways—two egress doorways required Unchanged. Three egress doors serve the suite—two direct exits to the exterior and on to an existing common egress access corridor serving multiple tenants. 705.4.2 Egress doorways - door swing Based on occupant load, the exit doors do not need to swing in the direction of travel. Existing doors at the main entrance and vestibule and the rear exit swing in the direction of travel, while the door leading to the common exit access corridor swing into the suite. 705.4.3 Egress doorways - door closing Existing doors at the main entrance and vestibule, the rear exit and the door leading to the common exit access corridor each have a door closer. 705.4.4 Panic hardware n/a—calculated occupancy below 49 occupants Utktl .,od.y,dmI NurtLiiiiplort. 1110H,0 lid 00 1,0 -.,�x f .,:IOir n:a. ,_„ 705.5 Openings in corridor walls Corridors in this occupancy are not required to be rated. 705.6 Dead end corridors There are no dead end corridors within the project work area. 705.7 means of egress lighting Egress lighting consists of battery pack emergency light units. Existing and new units shall be located as required by code. 705.8 Exit signs Existing compliant fixtures remain unchanged. Several new internally illuminated exit signs shall be installed as part of this project indicating egress. 705.9 Handrails Rear exit steps shall have code compliant handrails. 705.10 Guards Rear exit steps shall have code compliant guards. Section 706 Accessibility In accordance with Massachusetts Architectural Access Board 521 CMR section 3.3.2, because the project construction cost exceeds $100,000.00 and exceeds 30% of the full and fair cash value for the project suite (the suite being separated from the remainder of the building by fire walls, hence being defined as the building" for this purpose), all work within the project work area which is required to conform to the requirements of Massachusetts Building Code 780 CMR 8"' Edition Section 605 and 706 and Massachusetts Architectural Access Board 521 CMR shall be made to conform. All newly built components of the project shall be in compliance with Massachusetts Building Code 780 CMR 8th Edition Section 605 and 706 Massachusetts Architectural Access Board 521 CMR. Section 707 Structural The scope of this project work area does not affect any existing structural systems, nor does it affect applied loads on existing structural systems. Section 708 Electrical 708.1 New Installations Convenience outlet wiring, lighting, and data wiring are included in the project and shall comply with the requirements of the Massachusetts Electrical Code. 708.2 Existing Installations B-Business occupancy does not apply 708.3 Residential occupancies B-Business occupancy does not apply Section 709 Mechanical 709.1 Reconfigured or converted spaces Existing HVAC ductwork and diffusers shall be relocated and rebalanced at renovated areas to provide mechanical ventilation to all spaces within the project area. 709.2 Altered existing systems The existing and modified HVAC system shall provide at least the code minimum 5 CFM per occupant (215 CFM) of outside air and 15 CFM per occupant (645 CFM) of ventilation air. 709.3 Local exhaust A new anesthesia scavenging system serving the animal operating room shall be directly vented to the building exterior. ivt EEEEEEto E. NEENIE.EEIEEENEEE. AI1 nEi.. ,i3 .,._INI2. L,. ,f ,- « , liEENIEN LEL,1,n.n, , Section 710 Plumbing 5e-e- M/1 r "M"^'eA iN °3 /0/' / 710.1 Minimum fixtures Because the occupant load o e project work area story shall not be increased more than 20 cent, existing plumbing fixture quantities are not required to be m led. Section 711 Energy Conservation 711.1 Minimum requirements Level 2 Alterations to existing buildings or structures are permitted without requiring the entire building or structure to comply with the energy requirements of the international Energy Conservation Code or international Residential Code. Areas of major reconfiguration shall have a new code compliant thermal envelope constructed at the roof level, to replace the existing thermal insulation laying directly on the suspended acoustic ceiling system. This area shall be separated from other above ceiling areas where the thermal insulation lays directly on the suspended acoustic ceiling system and shall remain. END OF EXISTING CONDITIONS REVIEW REPORT SOW' I. h, mrt.m \ 1 n,,4. :H ,,. y_ m.