Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner'Name: Lynne Wallace
City/Town: Northampton, MA 01060 Date of Inspection: 2/27/09
inspection results must De suomittea on mis rorm. InspeCllon forms may not De anerea in any way.
Owner Address: 1023 Westhampton Rd. Florence. MA 01062
Copy to: Board of Health Northam
Witness: Homestead Inc.A: SSDS-1309
A. General Information
1. Inspector:
Name of Inspector: Thomas S. Leue R.S.
Company Name: Homestead Inc.
Company Address: 1664 Cape St. , Williamsburg MA 01096
Telephone Number: (413) 62$-4533 License Number SI130
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the information
reported below is true, accurate and complete as of the time of the inspection. The inspection was performed
based on my training and experience in the proper function and maintenance of on-site sewage disposal
systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR
15.000). The septic system condition must be evaluated and classified into one of the following four
conditions:
Passes
Conditionally Passes
Needs Further Evaluation by the Local Approving Authority
Fails
The system condition: Passes
Inspector's Signature:
Date: 2/27/09
The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of
Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a
design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the
appropriate regional office of the DEP. The original should be sent to the system owner and copies to the
buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use at
that time.This inspection does not address how the system will perform in the future under the same
or different conditions of use.
vised.doc•12/07 Title 5 Official Inspection Form:Subsurface Disposal System•Page 1 of 9
Commonwealth of Massachusetts
p Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner' Name: Lynne Wallace
City/Town: Northampton, MA 01060 Date of Inspection: 2/27/09
cation is
ed for
page.
ertification (cont.)
action Summary: Check A, B, C, D or E/always complete all of Section D
System Passes:
I have not found any information which indicates that any of the failure criteria as described in 310 CMR
15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below.
ments:
System Conditionally Passes:
One or more system components as described in the "Conditional Pass"section need to be replaced or
repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will
pass.
ter yes, no, or not determined (Y, N, or ND) in the_for the following statements. If not determined" please
explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally
und, exhibits substantial infiltration or exiltration, or tank failure is imminent. The system will pass inspection if
xisting septic tank is replaced with a complying septic tank as approved by the Board of Health.
etal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance
acing that the tank is less than 20 years old is available.
xplain
Observation of sewage backup or break out or high static water level in the distribution box due to broken or
ucted pipe(s)or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval
e Board of Health): broken pipe(s)are replaced
obstruction is removed
distribution box is leveled or replaced
aplaio.
The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will
inspection if(with approval of the Board of Health):
broken pipe(s) are replaced
obstruction is removed
xplain:
:urther Evaluation is Required by the Board of Health:
Conditions exist which require further evaluation by the Board of Health in order to determine if the system is
g to protect the public health, safety or the environment:
System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the
em is not functioning in a manner which will protect public health,safety and the environment:
Cesspool or privy is within 50 feet of a surface water.
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh.
visetl doc•12/07 Title 5 Official Inspection Form:Subsurface Disposal System•Page 2 of 9
Commonwealth of Massachusetts
r Title 5 Official Inspection Form
it
Cation is
'ed for
Page,
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner' Name: Lynne Wallace
City/Town: Northampton, MA 01060 Date of Inspection: 2/27/09
edification (cont.)
System will fail unless Board of Health (and Public Water Supplier, if any) determines that the system
ictioning in a manner that protects the public health, safety and environment:
The system has a septic tank and soil absorption system (SAS)and the SAS is within 100 feet of a surface
supply or tributary to a surface water supply.
The system has a septic tank and SAS and the SAS is within a Zone I of a public water supply.
The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well.
The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private
supply well" Method used to determine distance
s system passes if the well water analysis, performed at a DEP certified laboratory, for coliform bacteria
3tes absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided
to other failure criteria are triggered. A copy of the analysis must be attached to this form.
/then
System Failure Criteria Applicable to All Systems:
must indicate either YES (Y)or NO (N) as to each of the following for all inspections:
Backup of sewage into facility or system component due to an overloaded or clogged SAS or cesspool.
Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or
clogged SAS or cesspool.
Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool.
Liquid depth in cesspool is less than 6" below invert or available volume less than 1/2 day flow.
Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of
times pumped
Any portion of the SAS, cesspool or privy is below high ground water elevation.
Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water
supply.
Any portion of cesspool privy is within a Zone I of a public well.
Any portion of cesspool or privy is within 50 feet of a private water supply well.
Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply
with no acceptable water quality analysis. [This system passes if the well water analysis, performed at a
DEP certified laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia
nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are
triggered.A copy of the analysis must be attached to this form.]
The system is a cesspool serving a facility with a design flow of 2000 gpd-10,000 gpd.
The system fails: I have determined that one or more of the above failure criteria exist as defined in 310 CM
15.303, therefore the system fails. The system owner should contact the Board of Health should be contacted
to determine what will be necessary to correct the failure.
;OMMENT:
vised.doc•12/07
Title 5 Official Inspection Form:Subsurface Disposal System•Page 3 of 9
er
oration is
fired for
y page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner' Name: Lynne Wallace
City/Town: Northampton MA 01060 Date of Inspection: 2/27/09
edification (cont.)
arge Systems:To be considered a large system the system must serve a facility with a design flow of 10,000 to
)0 gpd. For large systems, you must indicate either YES (Y)or NO(N)as to each of the following, in addition to
uestions in Section D.
the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area(Interim Wellhead Protection Area- IWPA)or a
led Zone II of a public water supply well)
answered "yes"to any question in Section E the system is considered a significant threat, or answered "yes" in
on D above the large system has failed. The owner or operator of any large system considered a significant
t under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The
m owner should contact the appropriate regional office of the Department.
hecklist
k if the following have been done. You must indicate YES(Y) or NO(N)as to each of the following:
Pumping information was provided by the owner, occupant or Board of Health. =
Were any of the system components pumped out in the previous two weeks? =
Has the system received normal flows in the previous two week period? =
Have large volumes of water been introduced to the system recently or as part of the inspection? _
Were"as-built" plans of the system obtained and examined? (If not available note as N/A) =
Was the facility or dwelling was inspected for signs of sewage back up? =
Was the site was inspected for signs of break out? =
Were all system components, excluding the SAS, located on site? =
Were the septic tank manholes uncovered, opened, and the interior of the septic tank inspected for the
condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and
scum?
Was the facility owner(and occupants if different from owner) provided with information on the proper
maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System(SAS) on the site has been determined based on:
Existing information. For example, a plan at the Board of Health.
Determined in the field Of any of the failure criteria related to Part C is at issue approximation of distance is
unacceptable) [310 CMR15.302(5)].
vised.doc•12/07 Title 5 Official Inspection Form:Subsurface Disposal System•Page 4 of 9
Der
rmation is
u ired for
ry page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner' Name: Lynne Wallace
City/Town: Northampton, MA 01060 Date of Inspection: 2/27/09
ystem Information
iential Flow Conditions:
3 Number of bedrooms (design)
3 Number of bedrooms (actual)
497 DESIGN flow based on 310 CMR 15.203 (for example
4 Number of current residents
Y Does residence have a garbage grinder?
N Is the Laundry a separate system? [If yes, separate inspection required]
N Laundry system inspected?
N Seasonal use?
324 Water meter readings, if available (last 2 years usage) (gallons per day)
0 gpd x# bedrooms)
N Sump Pump? _
intinuous Last date of occupancy
MERCIAUINDUSTRIAL
of establishment:_
In flow(based on 310 CMR 15.203): = gpd
of design flow(seats/persons/sift, etc.):
se trap present?
;trial waste holding tank present?
sanitary waste discharge to the Title 5 system?
✓meter readings, if available:
date of occupancy/use'.
ER(describe):=
General Information
ping Records: Source of information: +OWnr?� I l C>,' s (r),,L" 1�GT-
N Was system pumped as part of the inspection (Y or N)
f yes, volume pumped: gallons
low was quantity pumped determined? _
Reason for pumping:
)omment: Pump on 3 to 4 year interval.
of System:
Septic tank, distribution box, soil adsorption system
Single cesspool
Overflow cesspool
Privy
Shared system (Y or N)Of yes, attach previous inspection records, if any) =
Innovative/Alternative technology. Attach copy of the current operation and maintenance contract(to be
obtained from system owner) __
Tight tank(Attach a copy of the DEP approval) =
Other(describe): _
viseddoc• 12/07
Title 5 Official Inspection Form.Subsurface Disposal System•Page 5 of 9
er
nation is
fired for
y page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner'Name: Lynne Wallace
City/Town: Northampton MA 01060 Date of Inspection: 2/27/09
>ystem Information (cont.)
lroximate Age: All components, date installed, and source of info.
?tic plan: DATED 5/18/02
N
(ding Sewer:
12
cast iron
26
nments:
tic Tank:
6
Concrete
0
58
100
72
1,812
10
1,500
22
3
47
1
11
Were sewage odors detected when arriving at the site (Y or N)
(locate on site plan)
Depth below grade (inches) Estimated Average
Material of Construction
Distance in feet from private water supply well or suction line
No problems seen.
(locate on site plan)
Depth below grade
Materials of Construction
If tank is metal, list age
Is age confirmed by a Certificate
Riser depth
Septic tank width
Septic tank length
Septic tank height
Calculated gross volume
Air space in tank
Net Volume
Baffle depth
Sludge thickness
Top Sludge : Bottom Baffle
Scum thickness
Bottom Scum : Bottom Baffle
g Top Scum : Top Baffle
(inches)
of Compliance?
(inches)
(inches)
(inches)
(inches)
(gallons)
(inches)
(gallons)
(inches)
(inches)
(inches)
(inches)
(inches)
(inches)
(attach a copy of certificate)
Interior dimensions
Interior dimensions
Interior dimensions
Calculated
Calculated
Averaae
Calculated
Average
Calculated
Calculated
Measured How were dimensions determined?
nments:
nk partially under deck which blocks access to inlet.
anting over center cover also restricts access . Suggest move tree.
:ommendations:
up on 3 to 4 year interval.
✓ised doc•12/07
Title 5 Official Inspection Form:Subsurface Disposal System•Page 6 of 9
ration is
ed for City/Town: Northampton, MA 01060 Date of Inspection: 2/27/09
page
system Information (cont.)
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner Name: Lynne Wallace
lase Trap: (Usually present in certain commercial systems)
N Grease Trap part of system?
Depth below grade (inches) Measured
Materials of construction:
Dimensions:
Scum thickness (inches) Average
_ Top of scum to top of outlet tee Calculated Inches
_... Bottom of scum to bottom of outlet tee Salcnlated Trachea
Date of last pumping
mments: condition
/lit or Holding Tank: (tank must be pumped at time of inspection)
N Tight tank part of system?
Depth below grade (inches) Measured
Materials of construction
Tank width Tank length (inches)
Tank height Capacity (gallons)
__. Design flow: gallons/day
Alarm Level (inches)
Alarms in working order?
Date of last pumping
mments: (condition of alarm and float switches, etc.)
Attach copy of current pumping contract(required). Is copy attached?
it Absorption System (SAS):
AS not located
slain why:
(locate on site plan, excavation not required):
leaching pits& number:
leaching chambers and number:
leaching galleries and number:
_ leaching trenches, number, length:
Y leaching fields, number, dimensions: 16 ft. x 42 ft.
overflow cesspool, number:
innovative/alternative system, Type:
mments: (note soil condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.)
• surface problems seen but covered with ice and snow.
vised doc•12/07 Title 5 Official Inspection Form:Subsurface Disposal System•Page 7 of 9
Commonwealth of Massachusetts
Title 5 Official Inspection Form
t1 Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
Property Address: 1023 Westhampton Road
Owner' Name: Lynne Wallace
City/Town: Northampton, MA 01060 Date of Inspection: 2/27/09
canon is
ed for
page.
iystem Information (cont.)
;tribution Box: Of present must be opened) (locate on site plan) ("D-box")
N D-box part of septic system?
0 Depth of liquid level above outlet invert Inches
mments(note if box is level and distribution to outlets equal, any evidence of solids carryover, and
t of D-box, etc. box level and flow approximately equal.
mp Chamber: (locate on site plan)
Y Pump part of septic system?
Y Pumps in working order: (Y or N)
maybe Alarms in working order: (Y or N)
mments (note condition of pump chamber, condition of pumps and appurtenances, etc.):
.arm test switch works OK but float did not activate.
tggest floats be checked by installer.
vy:
mments:
(locate on site plan)
Privy part of system?
Materials of construction:
Dimensions:
Depth of solids:
(soil conditions, signs of hydraulic failure, level of ponding,condition of vegetation, etc.)
:e Exam: (Source of Information)
Y Check Slope 9/28/01 Official Perc Date
Surface water 5/18/02 Official Plan Date
Y Check Cellar Other Official Source
N Shallow wells Other Source
42 Estimated depth to ground water (inches)
;ase indicate all the methods used to determine high groundwater elevation:
Y Observed site(abutting property/observation hole within 150 feet of SAS)
Checked with local Board of Health-explain:
Checked with local excavators, installers-explain:
u must describe how you established the high ground water elevation:
?doximorphic structures found in perc test.
• cf
izz
• T
• d
n
ma
7
ri
N
0
r
r
N
a
R
x
H O
0
cn
cn
• H
tri
0 0
V)• 4
1 6'
PL
11 1/2'
1-4 GE
leachfield
_a—pump control
'—pump chamber
n) a— septic tank
1/2'
0
Deck
distribution box
Porch
Deck
Existing 3 bedroom house
Fenc
city water in
Note: No known drinking water sources within 150' radius.
PL
Called North