Loading...
669 Part C Septic Inspection 2003 OFFICIAL INSPECTION FORM -NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address:; 669 Westhampton Road Owner: Grossman Date of Inspection: April 23,2003 TIGHT or HOLDING TANK: NO_(tank must be pumped at time of inspection)(locate on site plan) Depth below grade: Material of construction: concrete metal fiberglass polyethylene other(explain): Dimensions: Capacity: _gallons Design Flow: gallons/day Alarm present(yes or no): Alarm level. Alarm in working order(yes or no): Date of last pumping: Comments(condition of alarm and float switches,etc.): DISTRIBUTION BOX: NO(if present must be opened)(locate on site plan) Depth of liquid level above outlet invert: Comments(note if box is level and distribution to outlets equal,any evidence of solids carryover,any evidence of leakage into or out of box,etc.): minimal carry over PUMP CHAMBER: NO_(locate on site plan) Pumps in working order(yes or no): Alarms in working order(yes or no): Comments(note condition of pump chamber,condition of pumps and appurtenances,etc.): OFFICIAL INSPECTION FORM - NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: • 669(back)Westhampton Road Owner: Grossman Date of Inspection:April 23,2003 SOIL ABSORPTION SYSTEM(SAS): YES (locate on site plan,excavation not required) If SAS not located explain why: Type _1_leaching pits,number: .5 ft.diem 6 ft. deep total 36"lipoid.42-44"eff,lit. (buried 3 ft.) leaching chambers,number: leaching galleries,number: leaching trenches,number,length: leaching fields,number,dimensions: overflow cesspool,number: innovative/alternative system Type/name of technology: Comments(note condition of soil,signs of hydraulic failure,level of ponding,damp soil,condition of vegetation,etc.):No signs of failure. stone ok.and no Groundwater. Too of LT(qJ 36" CESSPOOLS:N/A (cesspool must be pumped as part of inspection)(locate on site plan) Number and configuration: Depth-top of liquid to inlet invert: Depth of solids layer: Depth of scum layer: Dimensions of cesspool: Materials of construction: Indication of groundwater inflow(yes or no): Comments(note condition of soil,signs of hydraulic failure,level of ponding,condition of vegetation, etc.): PRIVY: N/A(locate on site plan) • Materials of construction: Dimensions: Depth of solids: Comments(note condition of soil, signs of hydraulic failure,level of ponding,condition of vegetation, etc.): 9 'age 10 of 11 OFFICIAL INSPECTION FORM—NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION (continued) 'roperty Address: tG=i Gtr"ka O@1tid . )wnen Coco mcvS )ale of Inspection: y' 'z3 )o3 ;KETCH OF SEWAGE DISPOSAL SYSTEM 'rovide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks OT ienchtnarks. Locate all wells within 100 feet. Locate where public water supply enters the building. z (5<(V 5�<i/i# run{) be C& Dui?; _5' ti r iL� S..Q fat. ti‘ -44D 3 Ho,` 3 ern o 3 }� 3 hPW: No 0'4]n �yim vl 3 - t ac RLoki K.5 0- 3G'iao. cc,cr .pipe iltm=re. TES Np tt -t) = 15 y� c.C = 131 q- 73t.oz = ii Title 5 incnprt nn Form @15 nom 10 _ y Dumn. n — TEi teril i6S II _ rFF. eo11,'S7 N LISUaAlgW "20 D(2ide — /10 57a NtIJ , CdEle IN Ug2T, R-3r_zs 7 = za 3 1 = ZS CS/= 25'' C9z = 3I ' UWa1_ 5L p -z yq' OFFICIAL INSPECTION FORM -NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART C SYSTEM INFORMATION(continued) Property Address: : 669„(back)Westhampton Ro d Owner- Grossman Date of Inspection:April 23,2003 SITE EXAM Slope Surface water Check cellar YES*Dry Shallow wells Estimated depth to ground water 9-10'+1-feet Please indicate(check)all methods used to determine the high ground water elevation: N/A Obtained from system design plans on record-If checked,date of design plan reviewed: _Observed site(abutting property/observation hole within 150 feet of SAS) Checked with local Board of Health-explain: Checked with local excavators,installers-(attach documentation) Accessed USGS database-explain: You must describe how you established the high ground water elevation: Warr -v l .a ed on on-site dat grade apnroa 50-75 feet away._ Wetland l-v n tree!is l/+ t beta 11