Loading...
71 Septic Inspection 2006 Commonwealth of Massachusetts Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form Inspection results must be submitted on this form or on the official Title 5 Inspection Form dated 611512000.Inspection forms may not be altered in any way. A. Certification .g out 1. Property Information: he use 71 Sylvester Road ib key Property Address our Sara Weinberger&Mordechai Kamel not Owners Name turn 35 Harrison Avenue Owners Address Northampton City/Town Date of Inspection: 2. Inspector: Dennis R. Lacourse MA 01060 State Zip Code 3-24-06 Date Name of Inspector AAA Environmental consulting Company Name 238 Park Street Company Address Easthampton MA 01027 City/Town State Zip Code 413 527-7861 Telephone Number Certification Statement: I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of the inspection.The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. lam a DEP approved system inspector pursuant to Section 15.340 of Title 5(310 CMR 15.000).The system: ® Pass 8 Conditionally Passes ❑ Fails Local Approving Authority 3-24-06 Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP.The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ****This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. le Five Form doe•11/2004 Title 5 Official Inspection Form'Subsurface Sewage Disposal System• Page 1 of 16 t Commonwealth of Massachusetts Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form A. Certification (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/rown State Zip Code Sara Weinberger& Mordechai Kamel 3-24-06 Owners Name Date of Inspection Inspection Summary: Check A,B,C,D or E/always complete all of Section D A) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist Any failure criteria not evaluated are indicated below. Comments: I found no evidance of failure. B) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass"section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health,will pass. Answer yes, no or not determined (Y, N, ND)in the❑for the following statements. If not determined, please explain. ❑ The septic tank is metal and over 20 years old"or the septic tank(whether metal or not) is structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. 'A metal septic tank will pass inspection if it is structurally sound not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ND Explain: Is Five Form.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal System• Page 2 of 16 Commonwealth of Massachusetts Not for Voluntary Assessments of Subsurface Sewage Disposal System Form Title 5 Official Inspection Form A. Certification (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger 8 Mordechai Kamel 3-24-06 Owners Name Date of Inspection B) System Conditionally Passes(cont.): ❑ Observation of sewage backup or break out or high static water level in the distribution box due to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass inspection if(with approval of Board of Health): ❑ broken pipe(s)are replaced ❑ obstruction is removed ❑ distribution box is leveled or replaced ND Explain: ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s)are replaced ❑ obstruction is removed ND Explain: C) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. 1. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh le Five Form.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disp sSystem• Page 1 Commonwealth of Massachusetts Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form A. Certification (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/Town Slate Zip Code Sara Weinberger 8 Mordechai Kamel 3-24-06 Owner's Name Date of Inspection C) Further Evaluation is Required by the Board of Health (cont.): 2. System will fail unless the Board of Health(and Public Water Supplier, if any) determines that the system Is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system(SAS)and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well**. Method used to determine distance: **This system passes if the well water analysis, performed at a DEP certified laboratory, for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. 3. Other: e Five Forn.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal S 4 of 16 Commonwealth of Massachusetts Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form A. Certification (cont.) 71 Sylvester Road Property Address 01062 Florence MA CtylroWT State 2ipCode Sara Weinberger&Mordechai Kamel 3-24-06 Owner's Name Date of Inspection D)System Failure Criteria Applicable to All Systems: You must indicate"Yes" or"No"to each of the following for all Inspections: Yes No ® Backup of sewage into facility or system component due to overloaded or clogged SAS or cesspool (] 1 Discharge or ponding of effluent to the surface of the ground or surface waters due to an overloaded or clogged SAS or cesspool O ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool O ® Liquid depth in cesspool is less than 6° below invert or available volume is less than ' day flow ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: — O 0 Any portion of the SAS,cesspool or privy is below high ground water elevation. O ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well. O ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ 0 Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable water quality analysis. [This system passes if the well water analysis,performed at a DEP certified laboratory,for coliform bacteria and volatile organic compounds indicates that the well is free from pollution from that facility and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered.A copy of the analysis must be attached to this forth.] Yes No The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CMR 15.303,therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. tie Five Fom,.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal Page System of 16 Commonwealth of Massachusetts IITitle 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form A. Certification (coot.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Cade Sara Weinberger&Mordechai Kernel 3-24-06 Ownefs Name Date of Inspection E) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the questions in Section D. YES NO ❑ ❑ the system is within 400 feet of a surface drinking water supply ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply ❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area—IWPA)or a mapped Zone II of a public water supply well If you have answered"yes"to any question in Section E the system is considered a significant threat, or answered"yes" in Section D above the large system has failed. The owner or operator of any large system considered a significant threat under Section E or failed under Section D shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. e Five Form.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal Page System• 15 Commonwealth of Massachusetts IITitle 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form B. Checklist 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owners Name Date of Inspection Check if the following have been done. You must indicate"yes° or"no" as to each of the following: YES NO ❑ N ❑ 0 N ❑ Pumping information was provided by the owner, occupant, or Board of Health Were any of the system components pumped out in the previous two weeks? Has the system received normal flows in the previous two week period? Have large volumes of water been introduced to the system recently or as part of ❑ ® this inspection? ❑ ® Were as built plans of the system obtained and examined? (If they were not available note as N/A) N ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? N ❑ Were all system components, excluding the SAS, located on site? N ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)on the site has been determined based on: N ❑ Existing information. For example,a plan at the Board of Health. N ❑ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable)[310 CMR 15.302(3)(b)] 3 Five Fmm.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal System• Page 7 oe 16 Commonwealth of Massachusetts lof Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owners Name Date of Inspection Residential Flow Conditions: 3 Number of bedrooms(design): Number of bedrooms(actual): DESIGN flow based on 310 CMR 15.203(for example: 110 gpd x#of bedrooms): Number of current residents: Does residence have a garbage grinder? ❑ Yes ® No Is laundry on a separate sewage system? [if yes separate inspection required] ❑ Yes ® No Laundry system inspected? ❑ Yes ® No Seasonal use? ❑ Yes ® No Unable to read Water meter readings, if available(last 2 years usage(gpd)): Sump pump? ❑ Yes ® No 3 330 2 Last date of occupancy Date Commercial/Industrial Flow Conditions: Type of Establishment: Design flow(based on 310 CMR 15.203): Gallons per day(gpd) Basis of design flow(seats/persons/sq.ft., etc.): Grease trap present? ❑ Yes ❑ No Industrial waste holding tank present? ❑ Yes ❑ No Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No Water meter readings, if available: Last date of occupancy/use: Other(describe): le Five Form.doc•11/2004 Date Title 5 Official Inspection Form:Subsurface Sewage Disposal System• 8 Commonwealth of Massachusetts IITitle 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owner's Name Date of Inspection General Information Pumping Records: None Source of information: Was system pumped as part of the inspection? If yes,volume pumped: gallons How was quantity pumped determined? Reason for pumping: Type of System: Septic tank,disH14Wierrbox, soil absorption system ❑ Yes � No ❑ Single cesspool ❑ Overflow cesspool ❑ Privy ❑ Shared system (yes or no) (if yes, attach previous inspection records, if any) ❑ Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) ❑ Tight tank.Attach a copy of the DEP approval. ❑ Other(describe): Approximate age of all components, date installed Of known)and source of information: 1988 Previous Inspection Report Were sewage odors detected when arriving at the site? ❑ Yes ® No le Five Fomi.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal System S 9 s 16 Commonwealth of Massachusetts Title 5 Official Inspection Form I Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owners Name Date of Inspection Building Sewer(locate on site plan): Depth below grade. Material of construction: ❑cast iron 40 PVC ❑other(explain): Distance from private water supply well or suction line: 20" feet 36 feet Comments(on condition of joints, venting, evidence of leakage, etc.): All joints sound and no evidence of leakage,venting observed Septic Tank(locate on site plan): 2.5 Depth below grade: feet Material of construction: CO concrete ❑ metal ❑fiberglass ❑polyethylene ❑other(explain) If tank is metal, list age: years Is age confirmed by a Certificate of Compliance? (attach a copy of ❑ Yes ❑ No certificate) 66"X 126"X 65" Dimensions: Sludge depth: Distance from top of sludge to bottom of outlet tee or baffle Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle How were dimensions determined? e Five Forn.doc•11/2004 22" 19" By Ruler Title 5 Official Inspection Form:Subsurface Sewage Dispoossaal SyOstte fi Commonwealth of Massachusetts Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/rows State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owner's Name Date of Inspedion Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): All baffles are sound, liquied level even with outgoing line,no evidence of leakage in or out of the tank. Grease Trap (locate on site plan). Depth below grade: Material of construction: ❑concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle Date of last pumping: Date Comments(on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: ❑ concrete ❑ metal ❑fiberglass ❑polyethylene ❑other(explain): e Five Form.doc•112004 Title 5 Official Inspection Form:Subsurface Sewage • Disposal 9 Sys oemt Commonwealth of Massachusetts piTitle 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cunt.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owners Name Date of Inspection Tight or Holding Tank(cont.) Dimensions: Capacity: gallons Design Flow: gallons per day Alarm present: ❑ Yes ❑ No Alarm level: Alarm in working order: ❑ Yes❑ No Date of last pumping: Date Comments(condition of alarm and Float switches, etc.): Distribution Box(if present must be opened)(locate on site plan): Depth of liquid level above outlet invert Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): Pump Chamber(locate on site plan): Pumps in working order: ❑ Yes ❑ No Alarms in working order: ❑ Yes ❑ No e Five Fomi.doc•112004 Title 5 Official Inspection Fonn:Subsurface Sewage Disposaal S ste 18 Commonwealth of Massachusetts IITitle 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cost.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owner's Name Date of Inspection Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.): Soil Absorption System(SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Type: leaching pits number: ❑ leaching chambers number: ❑ leaching galleries number ❑ leaching trenches number, length: ❑ leaching fields number, dimensions: ❑ overflow cesspool number: ❑ innovative/altemative system Type/name of technology: Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation,etc.): No evidence of hydraulic failure or ponding. Pit was uncovered and opened up. s Five Form.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal System• Page 13 of 15 Commonwealth of Massachusetts I; Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owner's Name Date of Inspection Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration Depth—top of liquid to inlet invert Depth of solids layer Depth of scum layer Dimensions of cesspool Materials of construction Indication of groundwater inflow ❑ Yes ❑ No Comments(note condition of soil, signs of hydraulic failure, level of ponding,condition of vegetation, etc.): Privy(locate on site plan): Materials of construction: Dimensions Depth of solids Comments(note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): a Five Form.doc•11/2004 Title 5 Official Inspection Form:Subsurface Sewage Disposal System• Page 14 of 16 Commonwealth of Massachusetts 1, Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cont.) 71 Sylvester Road Property Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owner's Name Date of Inspection Sketch Of Sewage Disposal System: Provide a sketch of the sewage disposal system including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. e Five Foon.doc•I1/2004 S L-y V-F ;re*-' iz fr* -� Title 5 dual Inspection Form:Subsurface Sewage Dis osae System of 6• Commonwealth of Massachusetts lof Title 5 Official Inspection Form Not for Voluntary Assessments Subsurface Sewage Disposal System Form C. System Information (cont.) 71 Sylvester Road P operty Address Florence MA 01062 City/Town State Zip Code Sara Weinberger&Mordechai Kamel 3-24-06 Owner's Name Date of Inspection Site Exam: Slope Node Surface water ann , Check cellar y O' Shallow wells N-c-pr= Estimated depth to ground water: i- 1 Please indicate all methods used to determine the high ground water elevation: ❑ Obtained from system design plans on record If checked, date of design plan reviewed: Date Observed site (abutting property/observation hole within 150 feet of SAS) ❑ Checked with local Board of Health-explain: ❑ Checked with local excavators, installers-(attach documentation) ❑ Accessed USGS database-explain: You must describe how you established the high ground water elevation: Dug below the bottom of pit and found no evidence of ground watet. Also referred to prvious title 5 inspection report.. a Five Fonn doc•11/2006 Title 5 Official Inspection Form:Subsurface Sewage Disposaal System• 71 Slyvester Road,3-24-06