292 Certificate of Compliance 2007 NEWMAN ENVIRONMENTAL ENGINEERING
April 19, 2006
Board of Health
Attn. E. Mathews
210 Main Street
Northampton, MA 01060
RE: Septic system design review for Konstantine Sierros (Z0603-3)
Lot-3 Old Wilson Road,Northampton, MA
Dear Sir:
Per your request,this letter is submitted to confirm our telephone conversation today
concerning your design review of the above reference project:
1. I will notify the Owner and Contractor that the proposed septic system shall be
constructed 1.1-feet higher than shown on the design plan profile.
2. These changes will be documented in the as-built site plan upon completion of
construction. The as-built plan will state the as-built elevations of the bottom of the
SAS, distribution lateral inverts, D-box inverts, septic tank inverts, and building
sewer invert(at foundation wall).
3. The Contractor shall contact the Board of Health to coordinate for a site inspection of
system sub-grades prior to addition of Title 5 sand fill. The Contractor shall also
coordinate with the Board of Health and Engineer regarding inspection of system at
substantial completion, for inspection of components prior to burial and final grading.
Your assistance in expediting the Disposal Works Construction Permit, and associated
Building permit is appreciated. Thank you. If you should have any questions,please call
me(413-238-5383).
Very truly yours,
NE M• k ENVIRONMENTAL ENGINEERING
Greg:' ewman, P.E.
cc: Owner: Konstantine Sierros, 679 Park Hill Road, Florence, MA 01062
Contractor: David Loven, Reservoir Road, Westhampton, MA 01027
NEWMAN ENVIRONMENTAL ENGINEERING
21 Guard Road,P.G.Box 395,Wodhington,MA 0109B
Tel:413-238-5383 Fax:413-236-4276
NEWMAN ENVIRONMENTAL ENGINEERING
November 26,2007
Konstantine& Sunita Sierros
679 Park Hill Road
Florence, MA 01062
Engineer's Certificate of Compliance
THIS IS TO CERTIFY, That the On-Site Sewage disposal System installed Z or repaired/ replaced❑
on October 26, 2007 by Dave Loven,Westhampton, MA
for Sunita&Konstantine Sierros at Lot-3 Old Wilson Road,Northampton,MA
has been constructed in accordance with the provisions of TITLE 5 of the State Environmental Code as
described in the plan entitled:
SEWAGE DISPOSAL SYSTEM
AT
LOT-3 OLD WILSON ROAD,NORTHAMPTON,MA
Dated 3/27/06
Prepared by:Newman Environmental Engineering
Drawing No. Z0603-3
With the following exceptions noted:
1. Minor changes to the location of the new septic system facilities as noted on the enclosed"AS-
BUILT" site plan.
2. Leach field cover,final grading,and loam & seeding had not been completed at the time of
inspection.
Use of this system is conditioned on compliance with the following provisions:
1. The area over the leaching facilities shall be loamed& seeded(with grasses) and maintained
(by mowing) to prevent cover erosion and/or root intrusions from trees and shrubs.
2. Final grades shall be constructed and maintained as shown on as-built plan,attached;
including drainage swales.
DATE: /06/07 ENGINEER
CC: Board of Health
Contractor
G kiie . Newman,
P.'. 'o. 34017, Sanitary
&a 60 wait, 7/61.4detelaatea
212 %04 Street
7209tdamsaa, ?11,4 01060
led. 413-587-1214
?az 413-587-1221
Title V Certification of Compliance
TO BE FIJ T FD OUT BY THE SYSTEM INSTALLER
INSTALLER SIGN-OFF
Pursuant to 310.CMR 15.00 of the State Environmental Code:Title V,Minimum Requirements for the
Subsurface Disposal of Sanitary Sewage,Section 15.021 (3),the Installer of a system is required to sign
this form as a condition for issuance of a Board of Health Certificate of Compliance for the onsite septic
system /
This is to certify that the onsite sewage disposal system that I installed as: y new construction
pp repair(existing system)
at `9� MALI (v' :(A /P7ai on ///r/017
,DWCP number
(Address) ate)
has been constructed in compliance with 310 CMR 15.00, and all local requirements.Any changes to the
original approved plans have been reflected on an as-built plan that has been submitted to the Board of Health.
DApe al imufa! ,23o (rsE vc Z ail {,�eSf�no Mp}iqr.tijCt
(P nt Installer's name) (Street,City.and Zip Code)
p.d?. Y13 - 3= 7305°
7„
(it)
sraller's ature
uic/o9
(Date)
NOTE:This certification represents no warranty,expressed or implied as to the functioning or longevity of the on-site
subsurface disposal system Rather,the plan and installation are in compliance with all applicable rules and regulations as are
in effect at the time of plan submittal.