32C-229 (9) 8 HANCOCK ST SM-2016-0044
COMMONWEALTH OF MASSACHUSETTS
CITY OF NORTHAMPTON
GIS#: 6672
Map: 32C
Block: _229 SHEETMETAL PERMIT
Lot: 001 .•
Permit SHEETMETAL
Category: SHEETMETAL
Permit# SM-2016-0044 PERMISSION IS HEREBY GRANTED TO:
Project# J5-2016-002280
Exp
Contractor: License: Ex ires:
Est.Cost: $10,000.00
Fee Charged:$10.00 WILSON SERVICES,INC Sheetmetal-954 09/28/2015
Balance Due:$.00
Owner: ORENSTEIN DENISE
#of Fixtures Applicant: WILSON SERVICES,INC
'DigSafe# _ _ AT: 8 HANCOCK ST
UseGroup
COnstClass
ISSUED ON: 13-May-2016 AMENDED ON: EXPIRES ON:
TO PERFORM THE FOLLOWING WORK:
DUCT WORK FOR CENTRAL AIR DUCT SYSTEM
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
Fee Type: Receipt No: Date Paid: Check No: Amount:
Sheetmetal REC-2016-006597 13-May-16 12399 $50.00
212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:lhasbrouck@northamptonma.gov
GeoTMS®2016 Des Lauriers Municipal Solutions,Inc.
MAY 2 Commonwealth of Massachusetts
City Of Northampton
OW OF B XDM INSPECTION$
MA OtOBO
Date: Z (� Sheet Metal Permit permit#
Estimated Job Cost: $ (�l�' (,�/�z Permit Fee: $ �d - 19399
Plans Submitted:fyES N& Plans Reviewed: YES NO
Business License# Applicant License#
Business Information: Property Owner/Job Location Info
rmation:
Name:
1) sck'J Sel� V_ 6� SNC, Name: ✓l e Oneoo t/k)
Street: -1 7 � ��r"`�V`�� �� Street:
_ ��y
City/Town: I '"`" I V`�N�� '`- _ I "" � City/Town:
Telephone: 331 7 Telephone: l C 16 20_ �)_ 5�l
Photo I.D. required/Copy of Photo I.D. attached: YES NO
Staff Initial
J-1 / 'I-1-unrestricted license
J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less
Residential: 1-2 family L.,� Multi-family__ Condo/Townhouses Other
Commercial: Office Retail Industrial Educational
Institutional Other
y/
Square Footage: under 10,000 sq. ft. over 10,000 sq. ft. Number of Stories:
Sheet metal work to be completed: New Work: Renovation:
HVAC Metal Watershed Roofing Kitchen Exhaust System
Metal Chimney/Vents Air Balancing
Provide detailed description of work to be done:
z_ ce—nty-at ovc-L
I r1 I� t S>G S-�-eve (S Ste r
Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000
Minimum fees for jobs without Building Permit$50.00 Residential, $100.00 Commercial
15d
2
INSURANCE COVERAGE:
have a current liabilitinsurance policy or its equivalent which meets the requirements of M.G.L. Ch. 11'2 `Yes No
If you have checked Yes, indicate the type of coverage by checking the appropriate box below:
A liability insurance policy ❑ Other type of indemnity ❑ Bond ❑
OWNER'S INSURANCE WAIVER: I am aware that the licensee tinac not haves the insurance coverage required by Chapter 112 of the
Massachusetts General Laws, and that my signature on this permit application-:;my,- this requirement.
Check One Only
Owner ❑ Agent ❑
Signature of Owner or Owner's Agent
By checking this box❑,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and
accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be
in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws.
Duct inspection required prior to insulation installation: YES NO
Progrncc Tncnvrtinnc
Final TncnPrtion
Comment"
Type of License:
By ❑ Master
Title ❑ Master-Restricted
City/Town ❑Journeyperson
Signature of Licensee
Permit#
❑Journeyperson-Restricted
License Number:
Fee$ ❑
Check at A—zi mass gnv/r#r
Inspector Signature of Permit Approval
9 Load Short Form Job:
wri htsoft® Date: May 02,2016
Entire House By:
Wilson Services Inc
Project Information
For: Dgnise Qrenstein
2 s�
Design Information
Htg Clg Infiltration
Outside db (°F) 0 87 Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD (°F) 70 12 Fireplaces 0
Daily range - M
Inside humidity (%) 30 50
Moisture difference(gr/Ib) 29 24
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80AFUE Efficiency 0 SEER
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 1199 cfm Actual air flow 1199 cfm
Air flow factor 0.024 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.96
ROOM NAME Area Htgload Clg load Htg AVF Clg AVF
( t 2) (Btuh) (Btuh) (cfm) (cfm)
Room2 330 9806 4938 237 222
Room1 696 20183 8529 488 383
MASTER BED 254 6532 3735 158 168
MID BED 154 2763 3391 67 152
SMALL BED 121 1843 1485 45 67
2 HALL 87 1272 347 31 16
2ND FL REAR 180 3991 2453 97 110
2ND FL BATH 90 2192 1043 53 47
2ND RR STAIR HALL 60 975 771 24 35
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
�. wri htSOft°° 2016-May-12 08:14:41
9 Right-Suite®Universal 2012 12.1.07 RSU05275 Page 1
ACCPA ...(x86)\Wrightsoft HVAC\Denise Orenstein 2016.rup Calc=MJ8 Front Door faces: N
9 Project Summa Job:
wri htsoft Date: May 02,2016
Entire House By:
Wilson Services Inc
Project Information
For: Denise Orenstein
Notes:
Desicin Information
Weather: Springfield Westover AFB, MA, US
Winter Design Conditions Summer Design Conditions
Outside db 0 OF Outside db 87 OF
Inside db 70 OF Inside db 75 OF
Design TD 70 OF Design TD 12 OF
Daily range M
Relative humidity 50 %
Moisture difference 24 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 44346 Btuh Structure 23083 Btuh
Ducts 5212 Btuh Ducts 3609 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 49557 Btuh Use manufacturer's data n
Rate/swing multiplier 0.92
Infiltration Equipment sensible load 24556 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 856 Btuh
Ducts 317 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area(ft') 1972 1972 Equipment latent load 1173 Btuh
Volume(ft') 15776 15776
Air changes/hour 0.38 0.20 Equipment total load 25729 Btuh
Equiv.AVF (cfm) 100 53 Req. total capacity at 0.80 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref
Efficiency 80AFUE Efficiency 0 SEER
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 OF Total cooling 0 Btuh
Actual air flow 1199 cfm Actual air flow 1199 cfm
Air flow factor 0.024 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.96
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� Wrl ht5Oft° Ri g 2016-May-1208:14:41
9 ht-SuKe®Universal 2012 12.1.07 RSU05275
,40Z;K ...(x86)\Wrightsoft HVAC\Denise Orenstein 2016.rup Calc=MJ8 Front Door faces: N Page 1
Entire House d 1972 49557 26692 1199 1199
Other equip loads 0 0
Equip. @ 0.92 RSM 24556
Latent cooling 1173
TOTALS 1972 49557 25729 1199 1199
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft 2016-May-12 08:14:41
1 9 Right-Suite®Universal 2012 12.1.07 RSU05275
,40:;K ...(x86)\Wrightsoft HVAC\Denise Orenstein 2016.rup Calc=M,18 Front Door faces: N Page 2
Roo 2
11 cf � z 119 cf
163 cfm Z 163 cfm
Room1
16 cf
1199 cfm
2ND FL BATH
® 53 cfm
2ND FL REAR
® 110 cfm
2ND RR S AIR HALL
® cf m
® 67 cfm
SMALL BED
MID BED
® 152 cfm
31' cfm
2H L
MASTER BED
® 168 cfm