Loading...
32A-058 (30) 50 UNION ST 12 BP-2016-1307 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 32A-058 CITY OF NORTHAMPTON Lot: -000 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: renovation BUILDING PERMIT Permit# BP-2016-1307 Proiect# JS-2016-002253 Est. Cost: $3200.00 Fee: $100.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: STEPHEN D ROSS 079160 Lot Size(sq. ft.): Owner: WOGLOM SUSAN Zoning: URC(100)// Applicant: STEPHEN D ROSS AT. 50 UNION ST 12 Applicant Address: Phone: Insurance: 36 SERVICE CENTER RD (413) 584-1224 O WC NORTHAMPTONMA01060 ISSUED ON.5/11/2016 0:00:00 TO PERFORM THE FOLLOWING WORK.MOVE BATHROOM WALL POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeType: Date Paid: Amount: Building 5/11/2016 0:00:00 $100.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2016-1307 APPLICANT/CONTACT PERSON STEPHEN D ROSS ADDRESS/PHONE 36 SERVICE CENTER RD NORTHAMPTON01060(413)584-1224 Q PROPERTY LOCATION 50 UNION ST 12 MAP 32A PARCEL 058 000 ZONE URC(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid b Building Permit Filled out Fee Paid Typeof Construction: MOVE BATHROOM WALL New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 079160 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFQO�TION PRESENTED: pproved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management molition D lay Signature of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. RECENED ity of Northampton Status of hermit: Department a +~o�1�. uilding Department Curb CutlDriveway Permit 212 Main Street Sewer/Septic Availability Room 100 Water/Well Availability o hampton, MA 01060 Two Sets of Structural Plans DEF T. pFicq( X13- 87-1240 Fax 413-587-1272 Plot/Site Plans -- Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: / This section to be completed by office G t.j-v\: 0 � ��✓-�2-1'— Map Lot -Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: 5-0 Name(Print) Current Mailing Address: Telephone Signature 2.2 Authorized Agent: Name(Printy Current Mailing Address: ignat6re Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by pe,rmit applicant 1. Building c LJ (a) Building Permit Fee 2. Electrical — (b) Estimated Total Cost of Construction from 6 3. Plumbing _ Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total=0 +2+3+4+5) 3 Zai . IT Check Number /0-0 This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: Rear Building Heig Bldg. Sq re Footage % Open SAace Footage % (L area minus bldg arkrn #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? tll\ NO kj DONT KNOW QL YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DON'T KNOW 0 YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DONT KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 1 Date Issued: C. Do any signs exist on the property? YES NO je IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES 0 NO 0 IF YES, describe size, type and Location: E. Will the construction activity disturb(clearing, grading, exgavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES NO 0� 0 NU IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all agglicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) Roofing Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding [O] Other[ClJ Brief Description of Proposed / Work: .1'L �' ��. i 11 6-vet l kl'^l2 Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No ' Plans Attached Roll -Sheet sa. If New house and or addition to existing housinmi complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heatin ? Fireplaces or Woodstoves Number of each g. ergy Conservation Complian _ Masscheck Energy Compliance form attached? h. a of construction i. Is construc io in 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, S as Owner of the subject property hereby authorize �—� `� ✓ � �� to act on my behalf, in all mattej6 relativ to work authorized by this building;Tt pplication. Signature of Owner Date as Owner/Authorized Abyeclare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. fl Signed under th pains and penalties of perjury. _A P' m 7 I na ure Owner/ gent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Su ervis r: Not Applicable ❑ Name of License Holder: v License N tuber License Expir ion Date ign re Telephone 9—Registered Home Improvement Contractor: Not Applica`blle ❑ S t26 C'ti � cam✓ /Ro l:' y 7 Co any Name J / Registrat'on N ber // Ador ss l Exp ir tion Date telephone �'12Z� SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152, §25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes....... ❑ No...... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153 (Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances, State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature I N G May 5, 2016 —,--,/structural&Civil EngineeringNG-1- RO'B881 Tat 978-544-8= Wendell,MA 01379 rieet@wgdblue.net Construct Associates Attn: Stephen Ross 36 Service Center Rd. Northampton MA 01060 RE: Wall Removal 50 Union Street, Northampton, MA, Project# 16024 Mr. Ross, I visited#12 at 50 Union Street in Northampton on February 10, 2016 to determine whether a section of the wall the owner wanted removed was a structural wall. The wall in question is an approximately three foot section of interior wall between the half bathroom and the kitchen. It is my opinion, based upon my training and experience as a professional engineer, as well as my site visit, that the wall is not a structural wall and may safely be removed. Please call me if you have any questions regarding this project, Sincerely, ROBERT T. LEET Robert Leet, P.E. STRUCTURAL 38942 AW', 2 3 71- CENTERON,MA 01060fax:584-7504 C C RENOVATIONS FOR: SUSAN AND REFRIGERATOR ( REFRIGERATOR �� GEOFF WOGLOM �1 RESIDENCE 50 UNION ST.,#12 NORTHAMPTON,MA KITCHEN NEW WALL STARTS KITCHEN 01060 OAT OUTSIDE CORNER O I OF EX TING WALLS I OREMOVE EXISTING WALLS, loo REUSE EXISTING DOOR IN NEW ANGLED WALL-::V = REPLACE EX'.TILE: NEW CERAMC TILE 1/2 BATH/ 112 BATH/ LAUNDRY LAUNDRY T-51/2'CLG.HT. T-51/2'CLG.HT. MGir)INIS -- � IIVING/DINING E E44A1 BOOM STACKED B STACKED WID WID j DHW DHW CLOSET CLOSET CLOSET CLOSET 5-10-16 FOR REVIEW Dale sue �u EXISTING BATHROOM FLOOR PLAN 2 PROPOSED BATHROOM FLOOR PLAN 2'=I'-0" tnz•=r-0• A EXISTING AND PROPOSED BATHROOM PLANS 1/2"=V-0" 1 2 3 A-1 1